Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹6.5 Cr
EMD Value
₹6.5 L
Closing Date
3 Aug 2023, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Re-development of Multipurpose Hall at Jawahar Navodaya Vidyalaya, Angul, Odisha
NBCC/ODISHA/ZO/NIT/23-24/003
NBCC/ODISHA/ZO/NIT/23-24/003
Open Tender-Domestic
Civil Works General
Anugul, Odisha
₹11,800
₹6.5 L
3 Aug 2023
12 Jul 2023
3 Aug 2023
3 Aug 2023
11 Aug 2023
ABSTRACT OF COST CIVIL WORK
S.N. DESCRIPTION OF ITEM UNIT QUANTITY RATE AMOUNT
A SUB-HEAD-1 EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator) /
manual means in foundation trenches or drains (not exceeding 1.5 m in
1 width or 10 sqm on plan), including dressing of sides and ramming of
bottoms, lift upto 1.5 m, including getting out the excavated soil and
disposal of surplus excavated soil as directed, within a lead of 50 m.
.All kinds of soil. CUM 1606.55 302.23 485539.53
Extra for every additional lift of 1.5 m or part thereof in excavation /
2 banking excavated or stacked materials. CUM 808.78 110.10 89047.65
All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides
of foundations etc. in layers not exceeding 20cm in depth,consolidating
3 each deposited layer by ramming and watering, lead upto 50 m and lift CUM 838.68 267.56 224399.55
Supplying and filling in plinth with sand under floors, including watering,
4 ramming,consolidating and dressing complete. CUM 238.52 2277.04 543119.66
Excavating, supplying and filling of local earth (including royalty) by
mechanical transport upto a lead of 5km also including ramming and
5 watering of the earth in layers not exceeding 20 cm in trenches, plinth, CUM 988.17 388.41 383814.75
sides of foundation etc. complete.
B SUB HEAD-II -CONCREATE WORK 0.00 0.00
1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from
6 natural sources : 8 graded stone aggregate 40 mm CUM 200.75 6374.96 1279774.19
nominal size derived from natural sources)
Providing and laying damp-proof course 40mm thick with cement concrete
7 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : SQM 71.79 390.73 28050.33
4 graded stone aggregate 12.5mm nominal size derived from natural
Extra for providing and mixing water proofing material in cement concrete per
8 work in doses by weight of cement as per manufacturer's specification. 50kg 19.00 60.21 1144.05
Providing & applying a coat of residual petroleum bitumen of grade of VG-
10 of approved quality using 1.7kg per square metre on damp proof
9 course after cleaning the surface with brushes and finally with a piece of SQM 71.79 119.95 8611.38
cloth lightly soaked in kerosene oil.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement
: 3 coarse sand (zone-III) derived from natural sources : 6 graded stone
aggregate 20 mm nominal size derived from natural sources) over 75mm
10 thick bed of dry brick ballast 40 mm nominal size, well rammed and SQM 133.61 718.19 95956.89
consolidated and grouted with fine sand,including necessary
excavation,levelling & dressing & finishing the top smooth.
Brick edging in full brick width and half brick depth including excavation,
refilling and disposal of surplus earth lead upto 50 metres. With common
burnt clay F.P.S. (non modular) bricks of class designation 7.5
C SUB HEAD-III-REINFORCED CEMENT CONCRETTE 0.00 0.00
12 Centering and shuttering including strutting, propping etc. and removal of 0.00 0.00
form for all heights :
(a) Foundations, footings, bases of columns, etc. for mass concrete. SQM 245.82 324.46 79757.80
(b) Walls (any thickness) including attached pilasters, butteresses, SQM 83.16 705.44 58664.21
plinth and string courses etc.
(c) Suspended floors, roofs, landings, balconies and access platform. SQM 1036.92 807.64 837455.04
(d) Lintels, beams, plinth beams, girders, bressumers SQM 1783.39 640.96 1143077.30
(e) Columns,Pillars, Piers, Abutments, Posts and Struts. SQM 843.96 847.36 715136.09
(f) Edges of slabs and breaks in floors and walls Under 20 cm wide. SQM 291.40 191.65 55846.76
Extra for additional height in centering, shuttering where ever required
with adequate bracing, propping etc., including cost of de-shuttering and
decentering at all levels, over a height of 3.5 m, for every additional
height of 1 metre or part thereof (Plan area to be measured).Suspended
floors, roofs, landing, beams and balconies (Plan area to be measured)
Steel reinforcement for R.C.C. work including straightening, cutting,
bending, placing in position and binding all complete upto plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting,
bending, placing in position and binding all complete above plinth level.
Thermo-Mechanically Treated bars of grade Fe-500 D or more.
Add for plaster drip course/ groove in plastered surface or moulding to
R.C.C. projections.
Providing and laying in position ready mixed or site batched design mix
cement concrete for reinforced cement concrete work; using coarse
aggregate and fine aggregate derived from natural sources, Portland
Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in
recommended proportions as per IS: 9103 to accelerate / retard setting of
concrete, to improve durability and workability without impairing strength;
including pumping of concrete to site of laying, curing, carriage for all
17 leads; but excluding the cost of centering, shuttering, finishing and 0.00 0.00
reinforcement as per direction of the engineer-in-charge; for the following
grades of concrete.
Note: Extra cement up to 10% of the minimum specified cement content
in design mix shall be payable separately. In case the cement content in
design mix is more than 110% of the specified minimum cement content,
the contractor shall have discretion to either re-design the mix or bear the
cost of extra cement.
(I) All works upto plinth level 0.00 0.00
S.N. DESCRIPTION OF ITEM UNIT QUANTITY RATE AMOUNT
Concrete of M25 grade with minimum cement content of 330 kg 0.00 0.00
(i) R.C.C. work in Footing CUM 168.70 9149.25 1543478.76
(ii) R.C.C. work in Beam CUM 46.58 9149.25 426172.14
Concrete of M30 grade with minimum cement content of 350 kg 0.00 0.00
(iii) R.C.C. work in Columns CUM 38.98 9298.39 362451.19
(II) All works above plinth level upto floor V level 0.00 0.00
Concrete of M25 grade with minimum cement content of 330 kg 0.00 0.00
(i) R.C.C. work in Lintel CUM 5.49 10858.61 59613.78
(ii) R.C.C. work in Beam CUM 113.98 10858.61 1237664.63
(iv) R.C.C. work in Slab CUM 153.12 10858.61 1662670.72
(v) R.C.C. work in walls CUM 9.57 10858.61 103916.92
Concrete of M30 grade with minimum cement content of 350 kg 0.00 0.00
(iii) R.C.C. work in Columns CUM 58.52 11039.36 646023.20
D Masonry Work 0.00 0.00
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of
18 class designation 7.5 in superstructure above plinth level up to floor V Sqm 235.02 1072.62 252086.56
level.Cement mortar 1:4 (1 cement :4 coarse sand)
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at
19 every third course of half brick masonry. SQM 235.02 91.08 21406.50
Brick work with non modular fly ash bricks conforming to IS:12894, class
designation 10 average compressive strength in superstructure above
20 plinth level up to floor V level in : Cement mortar 1:6 (1 cement : 6 CUM 402.58 8087.75 3255966.27
Brick work with common burnt clay F.P.S. (non modular) bricks of class
21 designation 7.5 in foundation and plinth in: CUM 104.88 7015.13 735747.07
Cement mortar 1:6 (1 cement : 6 coarse sand)
Random rubble masonry with hard stone in foundation and plinth including
levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12
graded stone aggregate 20 mm nominal size) upto plinth level with :
Cement mortar 1:6 (1 cement : 6 coarse sand) CUM 61.08 7010.07 428175.38
E SUB HEAD-IV-CLADDING WORK 0.00 0.00
Providing and fixing 18 mm thick gang saw cut, mirror polished,
premoulded and prepolished, machine cut for kitchen platforms, vanity
counters, window sills , facias and similar locations of required size,
approved shade, colour and texture laid over 20 mm thick base cement
mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, 0.00 0.00
mixed with matching pigment, epoxy touch ups, including rubbing, curing,
moulding and polishing to edges to give high gloss finish etc. complete at
Granite stone slab of all colour and texture except black, Cherry/ 0.00 0.00
23 Area of slab upto 0.50 sqm SQM 1.10 3746.02 4120.62
24 Area of slab over 0.50 sqm SQM 30.86 3478.41 107343.66
Providing edge moulding to 18mm thick marble stone counters, Vanities
etc. including machine polishing to edge to give high gloss finish etc.
complete as per design approved by Engineer-in-Charge.
Granite work RM 114.90 441.30 50705.41
Extra for fixing marble /granite stone over and above corresponding basic
26 item, in facia and drops of width upto 150 mm with epoxy resin based RM 114.90 501.04 57569.44
adhesive including cleaning etc. complete.
Extra for providing opening of required size & shape for wash basins/
kitchen sink in kitchen platform, vanity counters and similar location in
27 marble/Granite/stone work including necessary holes for pillar taps etc. EACH 8.00 851.47 6811.73
including moulding, rubbing and polishing of cut edges etc. complete.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS:
15622 (thickness to be specified by the manufacturer), of approved make,
in all colours, shades except burgundy, bottle green, black of any size as
approved by Engineer-in-Charge, in skirting, risers of steps and dados,
28 over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) SQM 339.13 1120.45 379978.52
and jointing with grey cement slurry @ 3.3kg per sqm, including pointing
in white cement mixed with pigment of matching shade complete.
(Size-300x450 )
F SUB HEAD-V-WOOD & PVC WORK 0.00 0.00
Providing and fixing panelling or panelling and glazing in panelled or
panelled and glazed shutters for doors, windows and clerestory windows
29 (Area of opening for panel inserts excluding portion inside grooves or 0.00 0.00
rebates to be measured). Panelling for panelled or panelled and glazed
shutters 25 mm to 40 mm thick :
Float glass panes 0.00 0.00
5.0 mm thick glass panes (weight not less than 12.50 kg/sqm). SQM 34.50 2350.79 81102.34
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of
cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to
receive shutter of 30 mm thickness. The laminate shall be moulded with
fire resistant grade unsaturated polyester resin and chopped mat. Door
30 frame laminate shall be 2mm thick and shall be filled with suitable wooden RM 73.13 740.26 54135.17
block in all the three legs. The frame shall be covered with fiber glass from
all sides. M.S. stay shall be provided at the bottom to steady
Providing and fixing to existing door frames. 0.00 0.00
S.N. DESCRIPTION OF ITEM UNIT QUANTITY RATE AMOUNT
30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in
different plain and wood finish made with fire
retardant grade unsaturated polyester resin, moulded to 3
mm thick FRP laminate all around, with suitable wooden
blocks inside at required places for fixing of fittings and
31 polyurethane foam (PUF)/Polystyrene foam to be used as SQM 25.74 4176.15 107494.21
filler material throughout the hollow panel, casted
monolithically with testing parameters of F.R.P. laminate
conforming to table - 3 of IS: 14856, complete as per direction of
Engineer-in-charge.
Providing and fixing factory made uPVC white colour casement/ Casement
cum fixed glazed door comprising of uPVC multi-chambered frame, sash
and mullion (where ever required) extruded profiles duly reinforced with
1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming
process of required length (shape & size according to uPVC profile), uPVC
extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy
(white powder coated) 3D hinges and one handle on each side of panels
along with zinc plated mild steel multi point lockinghaving transmission
gear, cylinder with keeps and one side key, G.I fasteners 100 x 8 mm size
32 for fixing frame to finished wall and necessary stainless steel screws, etc. 0.00 0.00
Profile of frame & sash shall be mitred cut and fusion welded at all
corners, mullion (if required) shall be also fusion welded including drilling
of holes for fixing hardware's and drainage of water etc. After fixing frame
the gap between frame and adjacent finished wall shall be filled with
weather proof silicon sealent over backer rod of required size and of
approved quality, all complete as per approved drawing & direction of
Engineer-in-Charge. (Single / double glass panes and silicon sealent shall
be paid separately). Variation in profile dimension in higher side shall be
accepted but no extra payment on this account shall be made.
Note: For uPVC frame, sash and mullion extruded profiles minus 5%
Casement door with top hung ventilator with 3D and S.S.
friction hinges (400 x 19 x 1.9 mm) made of (big series)
frame 67 x 64 mm, sash 67 x 110 mm & mullion 67 x 80 SQM 34.50 11012.17 379920.02
mm all having wall thickness of 2.3 ±. 0.2 mm and
single glazing bead / double glazing bead of appropriate
dimension.(Area of door upto 2.50 sqm)
Providing and fixing fire resistant door frame of section 50 x 60 mm on
horizontal side & 35 x 60 mm on vertical sides having built in rebate made
out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/m²)
suitable for mounting 120 min Fire Rated Glazed Door Shutters. The frame
shall be filled with Mineral wool Insulation having density min 96Kg/m³ .
The frame will have a provision of G.I. Anchor fastners 14 nos ( 5 each on
33 vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing RM 56.80 1887.05 107184.46
in the opening along with Factory made Template for SS Ball Bearing
Hinges of Size 100x89x3mm for fixing of fire rated glazed shutter . The
frame shall be finished with a approved fire resistant primer or Powder
coating of not less than 30 micron in desired shade as per the directions of
Engineer - in- charge . (Cost of SS ball bearing hinges is excluded).
Providing and fixing 60 mm thick glazed fire resistant door shutters of 120
min Fire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested
and certified as per laboratory approved by Engineer-in-charge, with
suitable mounting on door frame, consisting of vertical styles, top rail &
side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60mm made
out of 1.6mm thick G.I. sheet (zinc coating not less than120gm/m²) duly
filled mineral wool insulation having density min 96 kg/m³ and fixing with
necessary stainless steel ball bearing hinges of size100x89x3mm of
approved make, including applying a coat of approved fire resistant primer
or powder coating not less than 30 micron etc all complete as per direction
of Engineer-in-charge (panelling to be paid for seperately).
Providing and fixing glazing in fire resistant door shutters, fixed panels &
partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet
(zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with
M4 x 38 mm SS screws at distance 75 mm from the edges and150 mm
c/c , including applying a coat of approved fire resistant primer/powder
coating of not less than 30 micron on G.I. beading, & special ceramic tape
of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231
(Part 3):2016 and as per direction of Engineer-incharge with glass of
35 required thickness having 120 minutes of fire resistance both integrity & SQM 2.88 42139.57 121361.98
radiation control (EW120) and minimum 20minutes of insulation (EI20).
The manufacturer have to give test report/certification of fire glass and
the glass should have the stamp showing the value of E, EW & EI. The
glass shall be tested in approved NABL accredited lab or by any other
body which operates in accordance with ISO/IEC 17011 and accredits labs
as per ISO/IEC 17025 for testing and calibration scopes shall be eligible.
The maximum glazing size shall not be
more than 1100x2200 mm (w x h) or 2.42 sqm.
Providing and fixing bright /matt finished Stainless Steel handles of
36 approved quality & make with necessary screws etc all complete. (a) 125 NOS 26.00 105.83 2751.69
Providing & fixing Stainless steel sliding door bolts ISI marked anodised
37 (anodic coating not less than grade AC 10 as per IS : 1868) transparent or NOS 13.00 719.00 9347.00
dyed to required colour or shade with nuts and screws etc complete. (a)
38 Providing and fixing stainless steel towerbolts (barrel type) with necessary 0.00 0.00
screws etc. complete.
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone
39 work by providing weather silicon sealant over backer rod of approved RM 328.72 89.82 29525.43
quality as per architectural drawings and direction of Engineer-in-charge
complete. Upto 5mm depth and 5 mm width
G SUB HEAD-VI-STEEL WORK 0.00 0.00
S.N. DESCRIPTION OF ITEM UNIT QUANTITY RATE AMOUNT
Steel work welded in built up sections/ framed work, including cutting,
hoisting, fixing in position and applying a priming coat of approved steel
40 primer using structural steel etc. as required. In gratings, frames, KG 559.13 149.93 83828.09
guard bar, ladder, railings, brackets,
gates and similar works
Providing and fixing stainless steel ( Grade 304) railing made of Hollow
tubes, channels, plates etc., including welding, grinding, buffing, polishing
and making curvature (wherever required) and fitting the same with
41 necessary stainless steel nuts and bolts complete, i/c fixing the railing with KG 1330.73 645.07 858409.48
necessary accessories & stainless steel dash fasteners , stainless steel
bolts etc., of required size, on the top of the floor or the side of waist slab
with suitable arrangement as per approval of Engineer-in-charge.
H Flooring 0.00 0.00
Chequerred precast cement concrete tiles 22 mm thick in footpath &
courtyard, jointed with neat cement slurry mixed with pigment to match
42 the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm SQM 81.65 1222.18 99790.67
thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Medium
shade pigment using 50% white cement 50% Grey cement
Marble stone flooring with 18 mm thick marble stone, as per sample of
marble approved by Engineer-in-charge, over 20 mm (average) thick base
of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with 0.00 0.00
grey cement slurry, including rubbing and polishing complete with :
Raj Nagar plain SQM 24.92 2099.51 52319.76
Kota stone slab flooring over 20 mm (average) thick base laid over and
jointed with grey cement slurry mixed with pigment to match the shade of
43 the slab, including rubbing and polishing complete with base of cement SQM 942.01 1798.07 1693803.46
mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars
laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse
44 sand) and jointed with grey cement slurry mixed with pigment to match SQM 124.60 2147.82 267617.91
the shade of the slabs, including rubbing and polishing complete.
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300
mm or more (thickness to be specified by the manufacturer), of 1st
quality conforming to IS : 15622, of approved make, in all colours,
45 shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick SQM 98.97 1290.77 127747.05
Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement
slurry @ 3.3 kg/ sqm including pointing the joints with white cement and
matching pigments etc., complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be
specified by the manufacturer) with water absorption less than 0.08% and
conforming to IS: 15622, of approved make, in all colours and shades,
46 laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), SQM 168.13 1492.58 250947.89
jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints
with white cement and matching pigments etc., complete. (a) Size of Tile
Providing and laying Vitrified tiles in floor in different sizes
(thickness to be specified by the manufacturer) with water
absorption less than 0.08% and conforming to IS:15622, of approved
brand & manufacturer, in all colours and shade, laid on 20 mm thick
cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement
slurry @3.3 kg/sqm including grouting the joints with white cement and 0.00 0.00
matching pigments etc. The tiles must be cut with the zero chipping
diamond cutter only . Laying of tiles will be done with the notch trowel,
plier, wedge, clips of required thickness, leveling system and rubber
mallet for placing the tiles gently and easily.
Double charge vitrified tile polished finish of size 0.00 0.00
Providing and laying Vitrified tiles in different sizes (thickness to be
specified by manufacturer), with water absorption less than 0.08 % and
onforming to I.S. 15622, of approved make, in all colours & shade, in
47 skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 SQM 16.61 1545.10 25664.18
cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm
including grouting the joint with white cement & matching pigments etc.
complete. Size of Tile 600x600 mm
Providing and laying flamed finish Granite stone flooring in required design
and patterns, in linear as well as curvilinear portions of the building all
complete as per the architectural drawings with 18 mm thick stone slab
over 20 mm (average) thick base of cement mortar 1:4 (1 cement :
4coarse sand) laid and jointed with cement slurry and pointing with white
48 cement slurry admixed with pigment of matching shade including rubbing, SQM 42.12 2728.72 114933.63
curing and polishing etc. all complete as specified and as
directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet
Black, Cherry Red, Elite
Brown, Cat Eye or equivalent.
Providing and laying Polished Granite stone flooring in required design and
patterns, in linear as well as curvilinear portions of the building all
complete as per the architectural drawings with 18 mm thick stone slab
over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4
49 coarse sand) laid and jointed with cement slurry and pointing with white SQM 70.27 4118.31 289393.76
cement slurry admixed with pigment of matching shade including rubbing,
curing and polishing etc. all complete as specified and as
directed by the Engineer-in-Charge.Polished Granite stone slab colour of
Black, Cherry/Ruby Red or equivalent
S.N. DESCRIPTION OF ITEM UNIT QUANTITY RATE AMOUNT
Providing and laying C.C. pavement of mix M-25 with ready mixed
concrete from batching plant. The ready mixed concrete shall be laid and
finished with screed board vibrator , vacuum dewatering process and
finally finished by floating, brooming with wire brush etc. complete as per
specifications and directions of Engineer-incharge.
(The panel shuttering work shall be paid for separately).
(Note:- Cement content considered in this item is @ 330 kg/cum.
Excess/less cement used as per design mix is payable/ recoverable
Extra for providing and mixing hardening compound of approved quality
51 as per manufacturer's specification in cement concrete. SQM 278.38 50.73 14122.35
Providing and filling in position rubberized bitumen hot sealing compound per cm
for sealing of expansion joints in roads / pavements all complete as per depth
direction of the Engineer-in-Charge. Using grade 'A' sealing compound per
conforming to IS: 1834 cm
Providing and laying Floor hardener compound over finished vdf flooring as
53 per directions of engineer in charge. KG 2108.98 66.00 139192.52
SUB HEAD-VII- ROOFING 0.00 0.00
FALSE CEILING 0.00 0.00
Providing and fixing false ceiling at all height including providing and fixing
of frame work made of special sections, power pressed from M.S. sheets
and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as
per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm
thick with flanges of 27 mm and 37mm, at m1200 mm centre to centre,
one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm
long with 6mm dia bolts, other flange of cleat fixed to the angle hangers
of 25x10x0.50 mm of required length with nuts & bolts of required size
and other end of angle hanger fixed with intermediate G.I. channels
45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to
which the ceiling section 0.5 mm thick bottom wedge of 80 mm with
tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre
to centre, shall be fixed in a direction perpendicular to G.I. intermediate
with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at
every junction, including fixing perimeter channels 0.5 mm thick 27 mm
high having flanges of 20 mm and 30 mm long, the perimeter of ceiling
fixed to wall/partition with the help of rawl plugs at 450 mm centre, with
25mm long dry wall screws @ 230 mm interval, including fixing of gypsum 0.00 0.00
board to ceiling section and perimeter channel with the help of dry wall
screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing
to a flush finish of tapered and square edges of the board with
recommended jointing
compound , jointing tapes , finishing with jointing compound in 3 layers
covering upto 150 mm on both sides of joint and two coats of primer
suitable for board, all as per manufacturer's specification and also
including the cost of making openings for light fittings, grills, diffusers, 0.00 0.00
cutouts made with frame of perimeter channels suitably fixed, all complete
as per drawings, specification and direction of
the Engineer in Charge but excluding the cost of painting with :
12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- SQM 498.06 1207.37 601348.99
(Part I) :2011 (Board with BIS certification marks)
Providing and fixing tiled false ceiling of specified materials of size
595x595 mm in true horizontal level, suspended on inter locking metal
grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/
sqm, both side inclusive) consisting of main "T" runner with suitably
spaced joints to get required length and of size 24x38 mm made from
0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center
and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet,
1200 mm long spaced between main "T" at 600 mm center to center to
form a grid of 1200x600 mm and secondary cross "T" of length 600 mm
and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be
interlocked at middle of the 1200x600 mm panel to form grids of 600x600 0.00 0.00
mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of
approved texture in the grid including, required cutting/making,
Opening for services like diffusers, grills, light fittings, fixtures, smoke
detectors etc. Main "T" runners to be suspended from ceiling using GI
slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm
dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with
galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 0.00 0.00
mm center to center along main T, bottom exposed width of 24 mm of all
T-sections shall be pre-painted with polyester paint, all complete for all
heights as per specifications, drawings and as directed by Engineer-in-
GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size
595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet
having galvanizing of 100 gms/sqm (both sides inclusive) and electro
statically polyester powder coated of thickness 60 microns
(minimum), including factory painted after bending.
S.N. DESCRIPTION OF ITEM UNIT QUANTITY RATE AMOUNT
Providing and Fixing 15 mm thick densified tegular edged eco friendly light
weight calcium silicate false ceiling tiles of approved texture of size 595 x
595 mm in true horizontal level, suspended on inter locking metal grid of
hot dipped galvanised steel sections (galvanising @ 120 grams per sqm
including both side) consisting of main ‘T’ runner suitably spaced at joints
to get required length and of size 24x38 mm made from 0.33 mm thick
(minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size
24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced
between main’T’ at 600 mm centre to centre to form a grid of 1200x600
mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made SQM 45.00 1810.82 81487.00
of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the
1200x 600 mm panel to from grid of size 600x600 mm, resting on
periphery walls /partitions on a Perimeter wall angle pre-coated steel of
size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the
help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall
screws @ 230 mm interval and laying 15 mm thick densified edges
calicum silicate ceiling tiles of approved texture in the grid, including,
cutting/ making opening for services like diffusers, grills, light fittings,
fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be
suspended from ceiling using G.I.
Supply and Installation of square edge, magnesite-bonded pinewood fibre
of .6-.8mm fiber, ceiling acoustical tile of size 600x1200x15mm, volume
density 120Kgs/m3, weight 6kg/m2 installed by using ceiling
framework.The Anutone Strut ceiling framework system shall include
Anutone Strut WC25 Wall channel, fully knurled, sectional thickness
0.55mm, length 3600mm, unequal flanges of 20 & 30mm and web of
25mm, fixed along the
perimeters of the wall with nylon sleeves and suitable fasteners at every
300mm centers. Then suspend Anutone Strut MC45 Main channels, fully
56 knurled, sectional thickness 0.8mm, length 3600mm, equal flanges of SQM 168.56 4386.00 739283.11
15mm and web 45mm from the soffit at 1200mm centers with Anutone
Strut SA25, fully knurled, Suspender angle
with sectional thickness 0.55mm, unequal flanges of 25 & 10mm. Anutone
Strut CC25 Cross channel, fully knurled, sectional thickness 0.55mm,
length 3600mm, web 35mm, depth of 20mm and equal flanges 9.5mm is
fastened to the Anutone Strut MC45 perpendicularly at 300mm centers.
Anutone Strand Fila is installed on the Anutone Strut CC25 with suitable
fasteners in staggered manner. Longer edges of the Strand Fila should be
perpendicular to length of CC25.The system is backlined with the
acoustical infill Anutone SynthPF 10x25
I SUB HEAD-VIII-FINSHING WORK 0.00 0.00
12mm cement plaster in single coat on fair side of single or half brick wall
for exterior plastering up to floor two level including internal rounded
57 angles chamfers, and/or rounded angles not exceeding 80mm in girth and SQM 1420.57 310.13 440557.34
finished even and smooth no extra for mixing any additive. 1:6 (1
cement: 6 coarse sand)
15 mm cement plaster on the rough side of single or half brick wall of mix
: 1:6 (1 cement: 6 coarse sand)
59 6 mm cement plaster on celling (a) 1:3(1 cement:3 fine sand) SQM 950.19 266.61 253333.46
Finishing walls with textured exterior paint of required shade: New work
60 (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming SQM 1136.46 258.13 293355.66
coat of exterior primer applied @ 2.20kg/10 sqm
Finishing walls with 100% Premium acrylic emulsion paint having VOC less
than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal
61 resistance, dirt resistance exterior paint of required shade (Company 0.00 0.00
Depot Tinted) with silicon additives.
New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and
including priming coat of exterior primer applied @ 0.90 litre/10 sqm. SQM 148.10 162.73 24100.74
62 Providing and fixing GRC Bricktile 15mm thickness as per manufacturer SQM 128.59 1955.00 251399.32
specificationa and directions of engineer in charge.
Applying priming coat: 0.00 0.00
63 With ready mixed red oxide zink chromate primer of approved brand and SQM 2047.22 58.47 119710.78
manufacture on steel galvanised iron/steel works.
64 Wall painting with acrylic emulsion paint of approved brand and 0.00 0.00
manufacture to give an even shade :
Two or more coats on new work. SQM 3741.49 145.24 543409.37
65 Painting with synthetic enamel paint of approved brand and 0.00 0.00
manufacture to give an even shade:
Two or more coats on new work. SQM 2047.22 138.50 283531.21
Providing and applying white cement based putty of average thickness 1
66 mm, of approved brand and manufacturer, over the plastered wall surface SQM 5162.06 130.49 673588.74
to prepare the surface even and smooth complete.
J SUB HEAD-IX -ALUMINIUM WORK 0.00 0.00
Providing and fixing aluminium work for doors, windows, ventilators and
partitions with extruded built up standard tubular sections/ appropriate Z
sections and other sections of approved make conforming to IS: 733 and
IS: 1285, fixing with dash fasteners of required dia and size, including
necessary filling up the gaps at junctions, i.e. at top, bottom and sides
with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall
be smooth, rust free, straight, mitred and jointed mechanically wherever
required including cleat angle, Aluminium snap beading for glazing /
paneling, C.P. brass / stainless steel screws, all complete as per
architectural drawings and the directions of Engineer-in-charge. (Glazing,
paneling and dash fasteners to be paid for separately) :
For fixed portion 0.00 0.00
Anodised aluminium (anodised transparent or dyed to required shade
67 according to IS: 1868, Minimum anodic coating of grade KG 305.10 457.21 139494.69
For shutters of doors, windows & ventilators including
providing and fixing hinges/ pivots and making provision
for fixing of fittings wherever required including the cost 0.00 0.00
of EPDM rubber / neoprene gasket required (Fittings
shall be paid for separately)
S.N. DESCRIPTION OF ITEM UNIT QUANTITY RATE AMOUNT
Anodised aluminium (anodised transparent or dyed to required shade
68 according to IS: 1868, Minimum anodic coating of grade KG 1386.50 560.30 776862.16
Providing and fixing glazing in aluminium door, window, ventilator shutters
and partitions etc. with EPDM rubber / neoprene gasket etc. complete as
69 per the architectural drawings and the directions of engineer-in-charge . SQM 169.16 1576.34 266654.29
(Cost of aluminium snap beading shall be paid in basic item):
With float glass panes of 8 mm thickness (weight not 0.00 0.00
less than 20 kg/sqm)
K SUB HEAD-X-WATER PROOFING 0.00 0.00
Providing and laying integral cement based water proofing treatment
70 including preparation of surface as required for treatment of roofs, 0.00 0.00
balconies, terraces etc consisting of following operations:
Applying a slurry coat of neat cement using 2.75 kg/sqm of cement
admixed with water proofing compound conforming to IS. 2645 and
(a) approved by Engineer-in-charge over the RCC slab including adjoining 0.00 0.00
walls upto 300 mm height including cleaning the surface before treatment.
Laying brick bats with mortar using broken bricks/brick bats 25 mm to
115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand)
admixed with water proofing compound conforming to IS : 2645 and
approved by Engineer-in-charge over 20 mm thick layer of cement mortar
(b) of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing 0.00 0.00
compound conforming to IS : 2645 and approved by Engineer-in-charge
to required slope and treating similarly the adjoining walls upto 300 mm
height including rounding of junctions of walls and slabs.
After two days of proper curing applying a second coat of cement slurry
(c) using 2.75 kg/ sqm of cement admixed with water proofing compound 0.00 0.00
conforming to IS : 2645 and approved by Engineerin- charge.
Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4
(1 cement :4 coarse sand) admixed with water proofing compound
conforming to IS : 2645 and approved by Engineerin- charge including
(d) laying glass fibre cloth of approved quality in top layer of plaster and 0.00 0.00
finally finishing the surface with trowel with neat cement slurry and
making pattern of 300x300 mm square 3 mm deep.
The whole terrace so finished shall be flooded with water for a minimum
(e) period of two weeks for curing and for final test. All above operations to 0.00 0.00
be done in order and as directed and specified by the Engineer-in-Charge :
With average thickness of 120 mm and minimum thickness at khurra as SQM 564.42 1604.58 905657.11
L SUB HEAD-XI-STRUCTURAL GLAZING 0.00 0.00
Providing and fixing High Quality ROOF Panel 50 MM Thick ,With both side
71 PPGI SHEET (SHEET MAKE TATA/JSW )(COLOUR WHITE OFF ) DENSITY 40 SQM 1219.29 2384.00 2906781.40
Providing and fixing High Quality WALL Puf Panel 50MM Thick ,with both
72 side.PPGI SHEET (SHEET MAKE TATA/JSW )(COLOUR OFF WHITE) SQM 700.05 2253.00 1577214.90
DENSITY 40 kg/m3 (+-2)
Structural steel work riveted, bolted or welded in built up sections, trusses
73 and framed work, including cutting, hoisting, fixing in position and KG 27600.00 117.95 3255434.35
applying a priming coat of approved steel primer all complete.
Steel work in built up tubular (round, square or rectangular hollow tubes
74 etc.) trusses etc., including cutting, hoisting, fixing in position and 0.00 0.00
applying a priming coat of approved steel primer, including welding and
bolted with special shaped washers etc. complete.
Hot finished seamless type tubes KG 3910.00 163.20 638122.32
Designing, providing, installing and fixing factory finished custom designed
cold form Light Gauge Steel Framed super structure comprising of steel
wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm
thick steel sheet as per design requirements. The steel sheet shall be
galvanized (AZ-150gms Aluminium Zinc Alloy coated steel having
minimum yield strength 300-550 Mpa) conforming to AISI specifications
and IBC 2009 for cold formed steel framing and construction and also as
per IS: 875-1987, ISO 800-1984 and IS:01-1975. The wind load shall be
as per provisions of IS 875 (part -III). LGSFS frame shall be designed as
75 per IS: 801 using commercially available software such as Frame CAD Pro- KG 8280.00 248.33 2056201.55
11.7/ STAAD PRO-V8i/ ArchitekV2.5.16/ Revit architecture-2011 or
equivalent. Proper usage of Connection Accessories like Heavy Duty
Tension Ties, Light Duty Hold-ons, Twist Straps (to connect truss with wall
frames), Strong Tie, Tie Rod, H-Brackets, Boxing Sections, L-Shaped
Angles for better structural stability. The framing section shall be cold
form C-type having minimum web depth 89 mm x 39mm flange x 11mm
lip in required length as per structural design requirement duly punched
with dimple/ slot at required locations as per approved drawings. The slots
will be along centre line of webs and shall be spaced minimum 250mm
away from both ends of the member. The frame can be supplied in
Designing, Providing, installing and fixing factory finished customed design
pregalvanized high tensile steel joists manufactured from G350 Z275
confirming to IS:277-1992, minimum coating of galvanizing 275 gm/sqm,
74 minimum yield stress 35 MPa & minimum tensile strength of 380 MPa KG 50.00 149.03 7451.59
placed 1.23 metre apart to support the load of slab etc as per the design
& directions of Engineer-in-Charge.
S.N. DESCRIPTION OF ITEM UNIT QUANTITY RATE AMOUNT
Providing and Fixing of Acoustical Wall Panel with square edges made of
fibre glass substrate 25mm thick, wrapped on the front side with an
acoustically transparent fabric as per the approved shade (Husk, Copper,
Sangria, Sesame, Coffee, Charcoal, Titanium, Flame, Peanut and Shell).
The panel shall be classified for Fire Class A, as per ASTM E-84. The
Acoustical Wall Panel shall be of sizes 600x600mm (Nominal) or
600x1200mm (Nominal) and shall achieve an NRC of 0.85 (Average value
of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and
2000 Hz) with 50mm airgap as per ASTM C423 to be fixed to wall on a
75 framework of wooden battens and using Wall panel Impalers (supplied by SQM 38.59 11192.00 431921.66
the manufacturer) or by using construction adhesives (as per the
instructions laid down by the manufacturer). The fibre glass substrate shall
have a recycle content of 85%. Properties of Tile Relevant Standards Base
Material Fibre Glass Panel Dimensions 600mm x 600/1200mm Panel
Thickness 25mm Panel Finish Acoustically transparent fabric as per the
approved shade (Husk, Copper, Sangria, Sesame, Coffee, Charcoal,
Titanium, Flame, Peanut and Shell). Fire Properties Class A ASTM E-84
Noise Reduction Co-efficient 0.85 ASTM C423 (Average value of
Absorption Coefficient readings taken at 250 Hz, 500 Hz, 1000 Hz and
Providing & fixing of 100% Natural Material- Magnesite (Hygroscopic &
biologically sound binding agent) bonded woodwool Panel planks of
600Mm*1200Mm *25Mm thickness made out of wood wool fibre of width
1Mm Fiber thickness mixed with Natural water & Magnesite (No-Cement)
with open & smooth surface texture. A Completly harmless Envirenment &
Human Friendly & also a disposable or recyclable Material & can last for
long span in building interiors As it has long lifespan & suitable for Indoor
conditions with relative air humidity of upto 90%. Magnesite protects the
76 wood cells against ageing & fungal attack. To achive upto NRC=1.00 it SQM 17.15 10800.00 185241.60
should be a clear gap of 200Mm from wall slab along with the backing of
Mineral of 50kg/m3. Edge Detail : AK 01 Heradesign Woodwool -
Acoustical Wall Mounting System Solutions- Ecologically Sound Material
with high mechanical strength with Crash test of 90Km/H with Ball Impact
Test DIN18032 & EN13964 with flying colors & A sustainable material
(PEFC & FSC Certified) along with EPD Certified Acc. to EN ISO 14025
(AUB-Environmental Product declaration).
Providing and fixing in position, 130 mm thick factory made Expanded
Polystyrene Core (EPS Core) wall panels consisting of EPS core sandwiched
between two Engineered sheets of welded wire fabric mesh duly finished
with shortcrete materials on outer faces. The fabric mesh shall be made of
3 mm dia zinc coated G.I. wire mesh with 50 mm pitch in both the
directions and on both faces of the wall and connected by GI wire of 3mm
dia at alternate row by welding. The EPS core shall consist of 60 mm thick
EPS of density not less than 16 kg/ per cum. Both the outer faces of the
panel shall be finished by applying the layer of 35 mm thick cement
mortar 1:3 {1 cement: 3 coarse sand (not having more than 40% stone
size upto 6 mm)} with the help of shotcreting/guniting equipment etc at a
pressure not less than 1 bar (100KN/m2) and both surfaces finished with
trowel. Fixing operations of wall panels shall be completed in all respect as
per drawings and specifications and under the overall direction of the
Engineer-in-charge.
SUB TOTAL 53017231.00
PLUMBING WORK 0.00 0.00
A. SUB HEAD -I : SANITARY FIXTURES & FITTINGS 0.00 0.00
Providing and Fixing white viterous china pedestal type water closet (
European type WC Pan ) with seat and lid , 10 litre low level White pvc
flushing cistern , including flush pipe with manually controlled device (
1 handle lever ) , Conforming to IS : 7231 with all fittings and fixtures Each 10.00 5837.52 58375.23
complete including cutting and making good the walls and floors wherever
required . WC Pan with ISI marked white solid plastic seat and lid .
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar
2 taps, 32 mm C.P. brass waste of standard pattern, including painting of 0.00 0.00
fittings and brackets, cutting and making good the walls wherever require
White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm Each 8.00 2396.94 19175.52
C.P. brass pillar tap
Providing and fixing 600x450 mm beveled edge mirror of superior glass (
3 of approved quality ) complete with 6 mm thick hard board ground fixed Each 8.00 1486.79 11894.30
to wooden cleats with C.P brass screws and washers complete .
Providing and fixing white vitreous china flat back half stall urinal of size
580x380x350 mm with white PVC automatic flushing cistern, with fittings,
standard size C.P. brass flush pipe, spreaders with unions and clamps (all
in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet 0.00 0.00
grating and other couplings in C.P. brass, including painting of fittings and
cutting and making good the walls and floors wherever required :
Range of three half stall urinals with 10 litre P.V.C. automatic flushing Each 1.00 19540.54 19540.54
Providing and fixing stone slab with table rubbed, edges rounded and
polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions
by cutting a chase of appropriate width with chase cutter and embedding
4 the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 0.00 0.00
cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size)
as per direction of Engineer-in-charge and finished smooth.
4.1 Granite Stone of approved shade Sqm 3.00 3732.75 11198.24
5 Providing & fixing C.P. brass bib cock of approved quality conforming to 0.00 0.00
5.1 15 mm nominal bore Each 18.00 457.47 8234.52
Providing and fixing CP Brass 32mm size bottle trap of approved quality & Each 8.00 933.75 7470.02
make and as per the direction of engineer in charge.
6 Providing and fixing C.P. brass angle valve for basin mixer and geyser 0.00 0.00
points of approved quality conforming to IS:8931
6.1 15 mm nominal bore Each 28.00 527.17 14760.73
S.N. DESCRIPTION OF ITEM UNIT QUANTITY RATE AMOUNT
7 Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, 0.00 0.00
collar and bush of approved quality and colour.
7.1 15 mm nominal bore with 45cm length Each 30.00 89.77 2693.00
Providing and fixing CP Brass extension nipple ( size 15mm x 50 mm ) of
8 approved make and quality as per direction of engineer - in - charge . Each 30.00 65.01 1950.21
9 Providing & fixing of Waste pipe for Wash basins & Sinks including pvc 0.00 0.00
waste fittings complete.
Flexible Pipe 0.00 0.00
Providing and placing on terrace (at all floor levels) polyethylene water
storage tank, ISI : 12701 marked, with cover and suitable locking
10 arrangement and making necessary holes for inlet, outlet and overflow Per Lit 10000.00 10.22 102199.20
pipes but without fittings and the base support for tank.
11 Providing and fixing PTMT grating of approved quality and colour 0.00 0.00
Providing and fixing 8mm dia C.P./S.S. Jet with flexible tube upto 1meter
long with S.S. Triangular plate to european type W.C. Of approved quality Each 10.00 315.40 3153.95
and make as approved by engineer in charge.
Providing and fixing vertical or horizontal storage type hot water heater
electrical operated fixed to wall with anchor bolts & nuts, 15mm CP brass
1 angle stop cock and 15mm CP brass non-return valve complete including 0.00 0.00
making connections with 15mm dia CP connecting pipes on inlet and
outlet, suitable length of power cable and 15 amps plug .
13.1 15 Litre Capacity Each 6.00 12081.00 72486.00
Providing and fixing toilet paper holder : 0.00 0.00
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm
high and 112 mm distance from wall of standard shape with bracket of the
same materials with snap fittings of approved quality and colour, weighing Each 6.00 154.14 924.85
not less than 105 gms.
Providing and fixing PTMT towel rail complete with brackets fixed to
wooden cleats with CP brass screws with concealed fittings arrangement of 0.00 0.00
approved quality and colour.
450 mm long towel rail with total length of 495 mm, 78 mm wide and Each 6.00 604.34 3626.07
effective height of 88 mm, weighing not less than 170 gms
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet 0.00 0.00
100 mm diameter Each 6.00 175.27 1051.60
Providing and fixing CP brass stop cock (concealed) of standard design and 0.00 0.00
approved make confirming to IS: 8931.
15mm nominal bore Each 12.00 626.63 7519.54
Providing & Fixing of Grab bar size 600X600 mm pipe O.D 32 mm ,
thiickness 2 mm of non slipping grip as per standard specification of use in Each 1.00 16312.00 16312.00
disabled toilet complete with brackets suitable for wall installation as per
approved sample complete in all respect.
B. SUB HEAD-II- SOIL , WASTE VENT AND RAIN WATER PIPE 0.00 0.00
Making khurras 45x45 cm with average minimum thickness of 5 cm
cement concrete 1:2:4 (1 cement:2 coarse sand:4 graded stone
1 aggregate of 20 mm nominal size) over P.V.C. sheet 1 mx1 mx400 Each 4.00 280.89 1123.56
micron, finished 12 mm cement plaster 1:3 (1 cement:3 coarse sand) and
a coat of neat cement rounding the edges and making and finishing the
outlet complete
Providing and Fixing on wall unplasticised Rigid PVC Rain water pipes
2 conforming to IS : 13592 Type A , including jointing with seal ring 0.00 0.00
conforming to IS : 5382 , leaving 10 mm gap for thermal expansion
2.1 Single Socketed pipes 110 mm diameter Metre 96.00 336.89 32341.31
3 Providing and Fixing to the inlet mouth of rain water pipe cast iron grating Each 8.00 50.47 403.74
15 cm diameter and weighing not less than 440 grams .
4 Providing and Fixing 100 mm diameter and 60 cm long rain water spout in 0.00 0.00
cement mortar 1:4 ( 1 Cement : 4 Fine Sand )
4.1 Stone Ware Spout Each 2.00 149.72 299.43
Providing and Fixing on wall face Rigid Unplasticised UPVC moulded fittings
5 / accessories for unplasticised Rigid PVC Rain water pipes conforming to IS 0.00 0.00
: 13592 Type A including jointing with seal ring conforming to IS : 5382
leaving 10 mm gap for thermal expansion .
Coupler 0.00 0.00
Single Push Fit Coupler 0.00 0.00
Single Tee with door 0.00 0.00
Single Tee without door 0.00 0.00
Bend 87.5 degree 0.00 0.00
Shoe ( Plain ) 0.00 0.00
Providing and Fixing unplasticised PVC pipe clips of approved design to
unplasticised - PVC rain water pipes by means of 50x50x50 mm hard
6 wood plugs , screwed with MS screws of required length , including cutting 0.00 0.00
brick work with fixing in cement mortar 1:4 ( 1 Cement : 4 Coarse Sand )
and making good the wall etc . complete
Providing and fixing uPVC 6 Kg/cm2 Soil , Waste & RWP pipes (IS: 13592
Class B) including all fittings (plain or door) e.g. bends, junction, cowls,
7 offsets, access pieces, jointing with rubber ring/solvent cement joints 0.00 0.00
including cutting chase or holes in walls and floors and making good
wherever required.
S.N. DESCRIPTION OF ITEM UNIT QUANTITY RATE AMOUNT
Providing & fixing in position upvc P"or S" trap of self cleaning design of
following sizes for the embedded areas Making proper connection with
8 chemical sealent joint , cutting chase / hole in floors /slabs and bringing 0.00 0.00
the same in proper condition in cement concrete 1:2:4 mix complete as
required. including cost of cutting and making good the walls and floors
where required.
8.1 110 mm inlet and 110 mm outlet Each 10.00 734.00 7340.00
9 Providing & fixing in position upvc floor drain including cost of cutting and 0.00 0.00
making good the walls and floors wherever required.
9.1 110 mm inlet and outlet Each 18.00 451.00 8118.00
Providing and fixing uPVC waste pipes for WB , SINK , URINAL , FD (IS:
4985 ) 6 Kg / Sqcm including all fittings (plain or door) e.g. bends,
10 junction, cowls, offsets, access pieces, jointing with rubber ring/solvent 0.00 0.00
cement joints including cutting chase or holes in walls and floors and
making good wherever required.
Providing and fixing Cast bronze chrome plated grating with ring and
11 Stainless steel anti cockroach basket and two SS screw including fixing to 0.00 0.00
the floor with cement mortar.
Providing and fixing UPVC inlet fitting with maximum 3 inlets 32,40 or 50
12 mm size fabricated from 110 mm dia UPVC pipes and fixed to upvc Each 7.00 4682.00 32774.00
sockets,fixed to upvc trap with chemical sealent joint and set in cement
concrete as per standard drawing complete.
Providing and fixing upvc cleanout plug( Ceiling or Floor) with suitable
13 insert keys for opening, male threaded joint with upvc socket fixed to 0.00 0.00
uPVC pipe complete in all respects.
13.1 110 mm diameter Pipe Each 4.00 538.00 2152.00
75 mm dia pipe Each 6.00 495.00 2970.00
C. SUB HEAD- III - INTERNAL WATER SUPPLY 0.00 0.00
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having
thermal stability for hot & cold water supply, including all CPVC plain &
brass threaded fittings, including fixing the pipe with clamps at 1.00 m
1 spacing. This includes jointing of pipes & fittings with one step CPVC 0.00 0.00
solvent cement and the cost of cutting chases and making good the same
including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc. 0.00 0.00
1.1 15 mm nominal outer dia Pipes Metre 35.00 464.80 16267.85
1.2 20 mm nominal outer dia Pipes Metre 40.00 541.29 21651.48
1.3 25 mm nominal outer dia Pipes Metre 40.00 659.61 26384.25
1.4 32 mm nominal outer dia Pipes Metre 40.00 750.95 30038.14
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having
thermal stability for hot & cold water supply, including all CPVC plain &
brass threaded fittings, including fixing the pipe with clamps at 1.00 m 0.00 0.00
spacing. This includes jointing of pipes & fittings with one step CPVC
solvent cement and testing of joints complete as per direction of Engineer
Internal work - Exposed on wall 0.00 0.00
25mm nominal bore Metre 40.00 429.87 17194.75
32 mm nominal bore Metre 40.00 527.80 21112.04
40mm nominal bore Metre 50.00 710.50 35524.76
50mm nominal bore Metre 120.00 976.69 117202.46
Providing and fixing Thermoflex or Careflex thermal insulation tubing, a
elastomeric flexible material having hermetic blister closed cell structure of
2 expanded synthetic rubber over pipes of following nominal bores and 0.00 0.00
thickness including all required accessories complete as per specification.
9 mm thick ( Pipes in Chases) 0.00 0.00
2.1 For 15 mm dia Pipe Metre 10.00 92.00 920.00
2.2 For 20 mm dia Pipe Metre 50.00 101.00 5050.00
For 32 mm dia Pipe Metre 20.00 120.00 2400.00
Providing and Fixing full way lever operated forged brass ball valve of
3 brass body with forged brass hard chromeplated steel ball tasted to a 0.00 0.00
pressure not less than 15 kg/sqcm with threaded / flanged joints complete
with nuts, bolts, gaskets, washers etc.
3.1 15 mm dia nominal bore Each 2.00 250.00 500.00
3.2 20 mm dia nominal bore Each 5.00 340.00 1700.00
3.3 25 mm dia nominal bore Each 5.00 512.00 2560.00
3.4 32 mm dia nominal bore Each 4.00 774.00 3096.00
3.5 40 mm dia nominal bore Each 3.00 1195.00 3585.00
Providing, fixing, testing and commissioning of motorised butterfly valve
of following dia for filling of overhead water tank complete with high and
low level control switches to control tanks. The level controllers shall be
installed in overhead tanks. The level switch will close the valve when
4 water level is high in overhead tank and open the valve when overhead 0.00 0.00
water tank level is low. The system should be complete in all respects with
accessories 220 V AC / 24 V DC, IP67 electrical water level control unit,
copper control wiring in whether proof casing etc.
4.1 40 mm dia nominal bore Each 1.00 11393.00 11393.00
SUB HEAD- IV DRAINAGE 0.00 0.00
Excavating trenches of required width for pipes, cables, etc including
excavation for sockets, anddressing of sides, ramming of bottoms, depth
up to 1.5 m, including getting out the excavated soil, and then returning
the soil as required, in layers not exceeding 20 cm in depth, including 0.00 0.00
consolidating each deposited layer by ramming, watering, etc. and
disposing of surplus excavated soil as directed,within a lead of 50 m :
All kinds of soil 0.00 0.00
Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia METER 270.00 439.72 118724.39
S.N. DESCRIPTION OF ITEM UNIT QUANTITY RATE AMOUNT
Providing and fixing square-mouth S.W. gully trap class SP-1 complete
with C.I. grating brick masonry chamber with water tight C.I. cover with
frame of 300x300 mm size (inside) the weight of cover to be not less than
4.50 kg and frame to be not less than 2.70 kg as per standard design: EACH 7.00 2585.06 18095.42
100x100 mm size P type. With common burnt clay F.P.S. (non modular)
bricks of class designation 7.5
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4
coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse
sand : 4 graded stone aggregate 20 mm nominal size), foundation
concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate
40 mm nominal size), inside plastering 12 mm thick with cement mortar 0.00 0.00
1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement
and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand
: 4 graded stone aggregate 20 mm nominal size) finished with a floating
coat of neat cement complete as per standard design :
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame
(light duty) 455x610 mm internal dimensions,total weight of cover and
frame to be not less than 38 kg (weight of cover 23 kg and weight of
With common burnt clay F.P.S.(non modular) bricks of class designation
Constructing brick masonry road gully chamber 45x45x77.5 cm with
bricks in cement mortar 1:4 (1 cement : 4 coarse sand ) with precast 0.00 0.00
R.C.C. vertical grating complete as per standard design :
with common burnt clay F.P.S.(non module) brick of class designation 7.5 EACH 12.00 6593.64 79123.67
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff
mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine 0.00 0.00
sand) including testing of joints etc. complete :
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand :
10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes
including bed concrete as per standard design : 0.00 0.00
150 mm diameter S.W. pipe EACH 130.00 1153.85 150000.51
Providing orange colour safety foot rest of minimum 6 mm thick plastic
encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS:
1786, having minimum cross section as 23 mmx25 mm and over all
minimum length 263 mm and width as 165 mm with minimum 112 mm
space between protruded legs having 2 mm tread on top surface by
ribbing or chequering besides necessary and adequate anchoring
projections on tail length on 138 mm as per standard drawing and suitable
to with stand the bend test and chemical resistance test as per
specifications and having manufacture's permanent identification mark to
be visible even after fixing, including fixing in manholes with 30x20x15 cm
cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone
aggregate 20 mm nominal size) complete as per design.
Making connection of drain or sewer line with existing manhole including
breaking into and making good the walls, floors with cement concrete
1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size) cement plastered on both sides with cement mortar 1:3 (1 0.00 0.00
cement : 3 coarse sand), finished with a floating coat of neat cement and
making necessary channels for the drain etc. complete :
For pipes 100 to 250 mm diameter
Constructing brick masonry circular type manhole 0.91 m internal dia at
bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse
sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1
cement : 3 coarse sand) finished with a floating coat of neat cement,
foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone 0.00 0.00
aggregate 40 mm nominal size), and making necessary channel in cement
concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20
mm nominal size) finished with a floating coat of neat cement, all
complete as per standard design :
0.91 m deep with SFRC cover and frame (heavy duty, HD-
20 grade designation) 560 mm internal diameter conforming to I.S.
12592, total weight of cover and frame to be not less than 182 kg., fixed
in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone 0.00 0.00
aggregate 20 mm nominal size) including centering, shuttering all
complete. (Excavation, foot rests and 12mm thick cement plaster at the
external surface shall be paid for separately) :
With common burnt clay F.P.S. (non modular) EACH 1.00 12523.56 12523.56
bricks of class designation 7.5
Supplying, installing, testing and commissioning vertical on line multi
stage centrifugal pumping set with mechanical seal, C.I. volute and SS
impeller & SS shaft connected to a TEFC induction motor of suitable HP for
415 volts, 3 phase, 50 cycles A.C. supply with 150 mm dia pressure
gauge with SS/gunmetal isolation cock, vibration eliminating pads, base
plate wiring upto panel and equipment for water level controller to start 0.00 0.00
and stop the pump automatically at predecided levels of the water in the
tank with provision of protection for dry run etc. complete in all respect
(The shop drawing or the pumps along with its characteristics curves,
model and technical data etc. are to be submitted for approval before
purchase of pump).
S.N. DESCRIPTION OF ITEM UNIT QUANTITY RATE AMOUNT
Domestic water pumps (Treated water transfer pump to terrace tank) 0.00 0.00
Capacity 50 lpm 0.00 0.00
SUB TOTAL 1825109.19
ELECTRICAL WORKS 0.00 0.00
SUBHEAD - I - CIRCUIT CUM POINT WIRING 0.00 0.00
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5
sq.mm FRLS PVC insulated copper conductor single core cable in surface /
1 recessed medium class PVC conduit, with modular switch, modular plate, 0.00 0.00
suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated
copper conductor single core cable etc. as required.
Wiring for group controlled (looped) light point/fan point/exhaust fan
point/ call bell point ( without Independent switch etc.) with 1.5 sq. mm
2 FRLS PVC insulated copper conductor single core cable in surface/ 0.00 0.00
recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC
insulated copper conductor single core cable etc as required. (Switch
Control Secondary Points)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5
sq.mm FRLS PVC insulated copper conductor single core cable in surface /
3 recessed steel conduit, with modular switch, modular plate, suitable GI 0.00 0.00
box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper
conductor single core cable etc. as required. (Switch Control Primary
Wiring for group controlled (looped) light point/fan point/exhaust fan
point/ call bell point (without Independent switch etc.) with 1.5 sq. mm
4 FRLS PVC insulated copper conductor single core cable in surface/ 0.00 0.00
recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC
insulated copper conductor single core cable etc as required. (Switch
Control Secondary Points)
MCB CONTROL LIGHT POINTS 0.00 0.00
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 2.5
sq.mm FRLS PVC insulated copper conductor single core cable in surface /
5 recessed steel conduit, with modular switch, modular plate, suitable GI 0.00 0.00
box and earthing the point with 2.5 sq.mm FRLS PVC insulated copper
conductor single core cable etc. as required. (Switch Control Primary
5.1 Primary point controlled by one MCB. Point 14.00 1535.50 21497.00
5.2 Same as item above but Secondary point. i.e. Points to be looped with Point 14.00 1365.90 19122.60
Primary point with 2.5 sqmm wire and Point wiring
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper
6 conductor single core cable in surface/ recessed steel conduit alongwith 1 Metre 350.00 456.21 159673.08
No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for
loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following
7 sizes of FRLS PVC insulated copper conductor, single core cable in surface/
recessed steel conduit as required.
7.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire Metre 50.00 344.53 17226.36
7.3 2 X 6 sq. mm + 1 X 6 sq. mm earth wire Metre 100.00 620.57 62057.04
7.4 2 x 10 sq. mm + 1 x 6 sq.mm earth wire Metre 150.00 748.06 112208.40
7.5 4 X 10 sq. mm + 2 X 6 sq. mm earth wire Metre 100.00 1228.50 122849.76
7.6 4 X 16 sq. mm + 2 X 6 sq. mm earth wire Metre 60.00 1733.17 103990.32
Supplying and fixing suitable size GI box with modular plate and cover in
8 front on surface or in recess, including providing and fixing 3 pin 5/6 A Each 16.00 502.57 8041.08
modular socket outlet and 5/6 A modular switch, connections etc. as
Supply and Wiring for 250 volts single phase and neutral 2 Nos 6 amps
socket outlate with control by 1 No switched with 2.5 sq.mm PVC
insulated copper conductor 1100 volts grade stranded flexible FRLS wires
in concealed or surface mounted 25 mm dia 2mm thick PVC conduit
9 including providing and fixing of 6 amps 3 pin switch socket outlet of Each 14.00 1796.31 25148.34
aprpoved make and design in 2 mm thick GI box with grid plate and
earthing of third pin of the socket with 2.5 Sq. mm PVC insulated
copper conductor stranded flexible FRLS wire.(maximum four no. of
switches socket shall be connected on one circuit)
Supplying and fixing suitable size GI box with modular plate and cover in
10 front on surface or in recess, including providing and fixing 6 pin 5/6 & Each 15.00 617.41 9261.14
15/16 A modular socket outlet and 15/16 A modular switch, connections
etc. as required.
11 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ Each 2.00 91.66 183.33
wooden block including connections etc. as required.
Supplying & fixing suitable size GI box wih modular plate and cover in
12 front on surface or in recess i/c providing and fixing 25 amp modular Each 2.00 765.97 1531.93
socket outlet and 25 Amps modular SP MCB, “C” curve including
connection, painting etc. as required. (AC's & Gysers)
Supplying and fixing following modular switch/ socket on the existing
13 modular plate & switch box including connections but excluding modular 0.00 0.00
plate etc. as required.
13.1 Telephone socket outlet Nos 4.00 155.93 623.73
Supplying and fixing following size/ modules, GI box alongwith modular
14 base & cover plate for modular switches in recess etc. as required. 0.00 0.00
Supplying and fixing following size/ modules, GI box alongwith modular
15 base & cover plate for modular switches in recess etc. as required. 0.00 0.00
15.1 3 pin , 5/6 amps socket outlet Each 2.00 128.54 257.08
Supplying and fixing following size/ modules, GI box alongwith modular
16 base & cover plate for modular switches in recess etc. as required. 0.00 0.00
S.N. DESCRIPTION OF ITEM UNIT QUANTITY RATE AMOUNT
Supplying and fixing of following sizes of medium class PVC
17 conduit along with accessories in surface/recess including 0.00 0.00
cutting the wall and making good the same in case of recessed
conduit as required.
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated
18.1 annealed copper conductor, unarmored telephone cable in the existing 0.00 0.00
surface/ recessed steel/ PVC conduit as required.
SUBHEAD - II - FITTINGS & FIXTURES 0.00 0.00
1 Supply, Installation, Testing and Commissioning of 9 W Bulk head Light. Each 6.00 1778.35 10670.10
2 Supply, Installation, Testing and Commissioning of 5W Mirror Light. Each 2.00 1077.79 2155.58
3 Supply, Installation, Testing and Commissioning of 18W Recessed/Surface Each 92.00 1975.94 181786.48
Mounted LED circular Downlighter.
4 Supply, Installation, Testing and Commissioning of 20W Wall/Surface Each 15.00 1975.94 29639.10
mouted 4 ft. LED
5 Supply, Installation, Testing and Commissioning of 65W Surface mounted Each 12.00 6107.46 73289.52
Supply, Installation, Testing and Commissioning of 12W Recessed
6 mounted LED circular Downlighter (Cat no-Bajaj Lighting BGSLO SLEEK Each 60.00 1167.60 70056.00
SURFACE 12W WH RD or equivalent as specified in the approved list of
7 Supply, Installation, Testing and Commissioning of 150W highway with Each 8.00 7469.82 59758.56
150LPW Ceiling mounted LED Light Fixtures
8 Supply, Installation, Testing and Commissioning of 250W Highway with Each 19.00 11204.73 212889.87
130LPW ceiling mounted LED Light Fixtures
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE
5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class
of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies,
shackle kit, safety rope, copper winding, Power Factor not less than 0.9,
Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210
Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%,
remote or electronic regulator unit for speed control and all remaining
accessories including safety pin, nut bolts, washers, temperature rise=75
degree C (max.), insulation resistance more than 2 mega ohm, suitable
for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as
Supplying and fixing two module stepped type electronic fan
10 regulator on the existing modular plate switch box including Each 20.00 388.78 7775.57
connections but excluding modular plate etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the
11 down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC Each 20.00 224.42 4488.34
insulated, copper conductor, single core cable etc. as required.
12 Supply of 300 mm dia Domestic Exhaust Fan Each 5.00 2155.58 10777.90
13 Supply of heavy duty 450mm Wall Fan each 15.00 6848.44 102726.60
SUBHEAD - III - MAIN BOARDS 0.00 0.00
Supplying, installing, testing & commissioning of following type
compartmentalised wall mounted / floor mounted cubicle board made
from 2mm thick CRCA sheet dust & vermin proof duly phosphatized &
1 powder coated inclusive of suitable size 4 strip Al. Busbar complete with 0.00 0.00
interconnection providing Lugs, inter-earthing, painting etc. i/c providing &
fixing below noted accessories:
Receiving,unloading,storing, handling, installation, testing and
commissioning of following MV Switchboards complete as required and as 0.00 0.00
per site condition and dimension of all panels shall be carried out as per
the attachad sld
1 MAIN LT PANEL ( FOR BUILDING ) Set 1.00 150800.00 150800.00
2 FIRE FIGHTING PANEL Set 1.00 40000.00 40000.00
SUBHEAD - IV - DISTRIBUTION BOARDS 0.00 0.00
Supplying and fixing following way, single pole and neutral,
sheet steel, MCB distribution board, 240 V, on surface/ recess, complete
1 with tinned copper bus bar, neutral bus bar, earth bar, din bar, 0.00 0.00
interconnections, powder painted including earthing etc. as required. (But
without MCB/RCCB/Isolator)
1.1 6 way, Double door Each 0.00 2324.24 0.00
1.2 8 way, Double door Each 1.00 2710.91 2710.91
1.3 12 way, Double door Each 2.00 2439.08 4878.17
Supplying and fixing following way, three pole and neutral, sheet steel,
MCB distribution board, 415 volts, on surface/ recess complete with tinned
2 copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, 0.00 0.00
interconnections, phosphatized and powder painted including earthing etc.
as required. (But without MCB/ RCCB/ Isolator)
Supplying and fixing of following ways surface/ recess mounting,
vertical type, 415 V, TPN MCB distribution board of sheet steel, dust
protected, duly powder painted, inclusive of 200 A tinned copper bus bar,
3 common neutral link, earth bar, din bar for mounting MCBs (but without 0.00 0.00
MCBs and incomer) as required . (Note :Vertical type MCB TPDB is
normally used where 3 phase outlets are required.)
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve,
4 miniature circuit breaker suitable for inductive load of following poles in 0.00 0.00
the existing MCB DB complete with connections, testing and
commissioning etc. as required.
4.2 Single Pole Neutral Each 0.00 631.11 0.00
Supplying and fixing following rating, double pole, 240 V, isolator in the
5 existing MCB DB complete with connections, testing and commissioning 0.00 0.00
etc. as required.
S.N. DESCRIPTION OF ITEM UNIT QUANTITY RATE AMOUNT
Supplying and fixing following rating, four pole, 415 V, isolator in the
6 existing MCB DB complete with connections, testing and commissioning 0.00 0.00
etc. as required.
Supplying and fixing following rating, double pole, (single phase and
7 neutral), 240 V, residual current circuit breaker (RCCB), having a 0.00 0.00
sensitivity current 30 mA in the existing MCB DB complete with
connections, testing and commissioning etc. asrequired.
Supplying and fixing DP sheet steel enclosure on surface/ recess along
8 with 25/32 A 240 V "C" curve DP MCB complete with connections, testing Each 2.00 1231.66 2463.32
and commissioning etc. as required.
9 Supplying and fixing single pole blanking plate in the existing Each 5.00 13.70 68.48
MCB DB complete etc. as required.
SUBHEAD - V - EARTHING 0.00 0.00
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including
1 accessories, and providing masonary enclosure with cover plate having Sets 1.00 7872.50 7872.50
locking arrangement and watering watering pipe 2.7 metre long etc. with
charcoal/ coke and salt as required.
Earthing with Cu. earth Plate 600mm x 600mm x 3mm thick including
accesssories, and providing masonary enclosure with cover plate (CI
2 heavy duty) having locking arrangement and watering pipe pipe of 2.7 Sets 1.00 14579.72 14579.72
mtr long etc. with charcoal or coke and salt) as required.
Supplying and laying 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe
3 from earth electrode, including connection with G.I. nut, bolt, spring, Mtr 20.00 743.84 14876.83
washer excavation and refilling etc. as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess
4 for connections etc. as required. 2 nos used for 50 x 5 for the Neutral Mtr 20.00 1224.28 24485.66
earthing of euipments )
5 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for Mtr 20.00 257.08 5141.57
connections etc. as required.
6 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop Mtr 20.00 73.75 1475.04
earthing etc. as required.
Supplying, fixing, testing and commissioning of following bare Copper/ GI
7 flat including all necessary fixing accessories and effecting connections. 0.00 0.00
7.1 50 mm x 6 mm thick Cu flat Metre 0.00 2350.00 0.00
7.2 50 mm x 6 m thick GI flat Metre 0.00 420.00 0.00
Supply and laying medium class GI pipe under road/paved areas/wall
8 crossing etc. including earth excavations refilling, ramming and making 0.00 0.00
good as approved.
8.1 150 mm dia GI pipe Class B Metre 10.00 1600.00 16000.00
SUBHEAD - VI - SUPPLYING & LAYING OF CABLE 0.00 0.00
L.T. CABLES 0.00 0.00
Laying of one number PVC insulated and PVC sheathed / XLPE power cable
of 1.1 KV grade of following size direct in ground including excavation,
1 sand cushioning, protective covering and refilling the trench etc. as 0.00 0.00
1.2 Above 35 sq. mm and upto 95 sq. mm Mtrs. 0.00 426.71 0.00
1.3 Above 95 sq. mm and upto 185 sq. mm Mtrs. 0.00 444.62 0.00
1.4 Above 185 sq. mm and upto 400 sq. mm Mtrs. 0.00 499.41 0.00
Laying of one number additional PVC insulated and PVC sheathed / XLPE
power cable of 1.1 KV grade of following size direct in ground in the same
2 trench in one tier horizontal formation including excavation, sand 0.00 0.00
cushioning, protective covering and refilling the trench etc. as required.
2.2 Above 35 sq. mm and upto 95 sq. mm Mtrs. 0.00 301.33 0.00
2.3 Above 95 sq. mm and upto 185 sq. mm Mtrs. 0.00 320.29 0.00
2.4 Above 185 sq. mm and upto 400 sq. mm Mtrs. 0.00 375.08 0.00
Supply of following sizes of XLPE insulated Aluminum conductor strip/
3 wire Armoured, overall PVC sheathed 1.1 KV grade cables conforming to 0.00 0.00
relevant IS-7098 Code and technical specifications.
Supplying and making end termination with brass compression gland and
4 aluminium lugs for following size of PVC insulated and PVC sheathed / 0.00 0.00
XLPE aluminium conductor cable of 1.1 KV grade
S.N. DESCRIPTION OF ITEM UNIT QUANTITY RATE AMOUNT
SUB HEAD -VII :EXTERNAL LIGHT 0.00 0.00
Supplying, installation, testing and commissioning of 65W LED Street Light
IP66 LED with High performance having system lumen output of minimum
9900 lumens, contemporary designed housing made of die-cast
1 aluminium, with street optic LENS for uniform light distribution. PF better Nos 4.00 7634.33 30537.32
than 0.9, CRI better than 70 complete with all accessories. Wipro Cat No.:
LR 02-102-XXX-57-G2 Street light
2 SITC of 6m ht. GI pole alongwith control box,6A MCB etc. as required for Nos 4.00 10000.00 40000.00
SUB-TOTAL AMOUNT 2668162.84
SUB-TOTAL AMOUNT 2668162.84
FIRE FIGHTING WORK 0.00 0.00
A. SUB HEAD - A : PUMPS & EQUIPMENTS 0.00 0.00
Supplying , Installation , Testing and Commissioning of Electric Driven
1 Terrace Pump Suitable for Automatic operation and Consisting of Following 0.00 0.00
Complete in all Respect as Required ( Terrace Fire Pump )
Horizontal Type Multistage , Centrifugal Pump of Cast Iron Body and
1.1 Bronze Impeller with Stainless Steel Shaft Mechanical Seal Conforming to 0.00 0.00
Suitable HP Squirrel cage Induction motor , TEFC , synchronous speed
1500 RPM , Suitable for operation on 415 Volts 3 Phase 50 Hz AC Supply
1.2 with IP 68 protection for enclosure Horizontal Foot Mounted type with 0.00 0.00
class F insulation Conforming to IS : 325 with Energy Efficiency class IE-3
1.3 MS Fabricated Common Base Plate Coupling , Coupling Guard Foundation 0.00 0.00
bolts etc as Required
1.4 Suitable Cement Concrete Foundation duly Plastered with anti vibration 0.00 0.00
The Head of the Pump is Selected in a manner so as to give a minimum 0.00 0.00
3.5 kg/sqcm pressure at the highest / farthest point
2 and flanged connection to riser drain arrangement with 25 mm dia gunmetal wheel
height with air release valve on top Setvalve with 2required accessories
pressure gauge and painting with synthetic enamel paint of approved shade
B. PIPING, HYDRANT , AND ACCESSORIES SYSTEM 0.00 0.00
Providing Laying Testing and Commissioning of C class Heavy duty MS
Pipe Conforming to IS : 1239 / 3589 including Fittings like elbows , tees ,
flanges , tapers , nuts , bolts , gaskets etc in ground including welding
1 excavation and Providing cement concrete blocks as supports anticorrosive 0.00 0.00
treatment with coaltar / asphalts tape as per IS :10221 refilling the trench
etc of following sizes complete as required .
Supplying Fixing Testing and Commissioning of butterfly valve of PN 1.6
2 Rating with Bronze Gunmetal Sheet duly ISI marked complete with nuts , 0.00 0.00
bolts , washers , gaskets conforming to IS : 13095 of following sizes as
Providing Installation Testing and Commissioning of Non Return Valve of
3 following sizes conforming to IS : 5312 complete with rubber gasket , GI 0.00 0.00
Bolts , Nuts , washers etc as required .
Providing Installation Testing and Commissioning of Stainless Steel Y
4 Strainer fabricated out of 1.6 mm thick stainless steel , Grade 304 , Sheet 0.00 0.00
with 3 mm dia holes with stainless steel flange .
Supplying and Fixing Single Headed Internal Hydrant Valve with
5 instantaneous gunmetal material coupling of 63 mm dia with cast iron 0.00 0.00
wheel ISI marked conforming to IS : 5290 ( Type A ) with blank Gunmetal
material cap and chain as required .
5.1 Single Headed Gunmetal Material Set 3 8055.83 24167.48
Supplying and Fixing orifice plate made out of 6 mm thick stainless steel (
Grade 304 ) with orifice of required size to be fitted between flange and
6 landing valve of external and internal hydrants to reduce pressure at the Each 4 1391.81 5567.22
outlet to the level of 3.5 kg / sqcm complete as required .
Supplying and Fixing 63 mm dia 15 m Long RRL Hose pipe with 63 mm
7 dia male and female coupling duly bound with GI wire , rivet etc . 0.00 0.00
Conforming to IS : 636 ( Type A ) as Required .
7.1 Gunmetal Material Set 3 5480.83 16442.48
Supplying and Fixing First aid hose reel with MS Construction Spray
8 painted in Post office red conforming to IS : 884 complete with the 0.00 0.00
following as required
20 mm nominal internal dia water hose thermoplastic ( Textile Reinforced 0.00 0.00
) Type - 2 as per IS : 12585
20 mm nominal internal dia gunmetal globe valve and nozzle 0.00 0.00
Drum and Brackets for fixing the equipments on wall 0.00 0.00
Connections from Riser with 25 mm dia stop gunmetal valve and MS Pipe 0.00 0.00
Supplying and Fixing 63 mm dia Gunmetal Short Branch Pipe with 20 mm
9 nominal internal diameter size nozzle conforming to IS : 903 suitable for 0.00 0.00
instantaneous connection to interconnect hose pipe coupling as required .
9.1 Gunmetal Material Set 6 2545.50 15272.99
10 Providing and Fixing of Pressure Switch in MS Pipe Line including Each 1 1628.87 1628.87
connection etc as required
Providing and fixing of Fire Hose Cabinet size not less than 2.1 x 1.2 x
0.90 mtr made out of M.S. sheet not less than 1.5 mm thick having
central opening and 4 mm thick glazed glass doors (Two nos.) suitably
11 marked on the outside 'with the letters "FIRE HOSE" including necessary Each 3 30495.00 91485.00
locking arrangement and painting in PO red colour suitable to
accommodate, internal hydrant valve, 2 nos 15 mtr long Hose pipe,
branch pipe, nozzle and fire man's axe. It shall be fixed inside the FHC
Cabinet Complete as required .
S.N. DESCRIPTION OF ITEM UNIT QUANTITY RATE AMOUNT
Providing and fixing weather proof Fire Hose Cabinet of size not less than
0.75 x 0.6 x 0.25 mtr made out of M.S. sheet not less than 1.5 mm thick
having central opening and 4 mm thick glazed glass doors (Two nos.)
suitably marked on the outside 'with the letters "FIRE HOSE" including
12 necessary locking arrangement and painting in PO red colour suitable to Each 3 11854.00 35562.00
accommodate, external yard hydrant valve, 2 nos 15 mtr long Hose
pipe, branch pipe, nozzle and fire man's axe. It shall be mounted on
boundary wall complete as required.
Providing & fixing Controlled Percolating (CP) Hose ISI marked (IS:8423)
63 mm dia x 15 m long complete with instantaneous type Stainless steel
13 63 mm dia ISI marked Male & Female couplings (IS:903) bound and Each 6 5081.00 30486.00
riveted to hose pipe with copper rivets and 1.5 mm copper wire.brusting
pressure not less than 22 Kg/Sqcm. ( Two nos. for each hydrant-
14 Providing and fixing standard firemans axe with heavy rubber handle. Each 3 1467.00 4401.00
Providing and fixing dial type pressure gauge with isolation cock and
15 copper pipe on main header Dial diameter 100 mm celebration 0-16 / sq. Each 12 3458.00 41496.00
Providing and fixing Fire Extinguishers (CO2 type powder ) 4 Kg Capacity
16 complete with all accessories as per manufacturers specifications. Each 1 5647.00 5647.00
Providing and fixing Fire Extinguishers (A, B, C type powder ) 5 Kg
17 Capacity complete with all accessories as per manufacturers Each 14 4518.00 63252.00
specifications.
SUB-TOTAL AMOUNT 913473.10
SUB-TOTAL AMOUNT 913473.10
FIRE ALARAM WORK 0.00 0.00
SUBHEAD - I - FIRE ALARM SYSTEM 0.00 0.00
Supplying, installation, testing and commissioning of micro
processor based intelligent addressable main fire alarm
panel, central processing unit with the following loop
modules and capable of supporting not less than 240 devices (including
detectors) and minimum 120 detectors per loop and loop length up to 2
km, network communication card, minimum 320 character graphics/ LCD
display with touch screen or other keypad and minimum 4000 events
1 history log in the non volatile memory (EPROM), power supply unit (230 ± 0.00 0.00
5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free
batteries with automatic charger. The panel shall have facility to connect
printer to printout log and facility to have seamless integration with
analog/digital voice evacuation system (which is part of the schedule of
work under SH: PA System) and shall be complete with all accessories .
The panel shall be compatible for IBMS system with open protocol
BACnet/ Modbus over IP complete as per specifications.
Supplying, installation, testing & commissioning of repeater
2 panel wih 320 character/ Touch screen LCD display with inbuilt reset, Nos. 1.00 114513.68 114513.68
acknowledge and silence switches complete as required.
3 Supplying, installation, testing & commissioning of addressable fire control Nos. 2.00 3163.96 6327.92
module complete as required.
Supplying, installation, testing & commissioning of Addressable monitor
module, 100% soft addressed from panel, integral short circuit isolators,
capable of monitoring NO contacts, Option to choose operation mode as
4 supervision of 20Sec or activation immediatee to connect NO/NC contacts Nos. 2.00 3134.45 6268.89
such as pressure switch, flow switches, fire pump contacts etc Module shall
be supplied with mounting plate from OEM for ease of installation &
5 Supplying, installation, testing & commissioning of addressable horn cum Nos. 5.00 3693.92 18469.61
strobe complete as required.
6 Supplying, installation, testing & commissioning of addressable manual call Nos. 5.00 4078.49 20392.43
point complete as required.
7 Supplying, installation, testing & commissioning of fire fighter telephone Nos. 2.00 6047.66 12095.33
handset complete as required.
8 Supplying, installation, testing & commissioning of fire fighter phone jack Nos. 2.00 1685.76 3371.52
complete as required.
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V
9 rated with annealed copper conductor having XLPE insulation, steel wire Mtrs 250.00 182.27 45568.20
armouring & FRLS outer sheath complete as required.
Supplying and fixing of following sizes of steel conduit along with
10 accessories in surface/recess including painting in case of surface conduit, 0.00 0.00
or cutting the wall and making good the same in case of recessed conduit
SUB-TOTAL AMOUNT 542566.04
SUB-TOTAL AMOUNT 542566.04
AUDIO SYSTEM 0.00 0.00
Supply of FBT Line Array Compact Bass reflex Active line array - 2x10" +
2x1"- 600Wrms+300Wrms Class D amplifiers, 600W RMS to the LF, 300W
RMS to the HF 2 x 10” woofers with 2.5" coil 2 x custom B&C HF
compression drivers with 1" throats DSP on board with 8 preset 90°
horizontal waveguide up to 18kHz Control panel with XLR «in&link», HF
level, preset, HP filter, GND lift switch High SPL capability: 135dB
Integrated rigging hardware Completely Manufactured in Italy (FBT-Muse-
Supply of Powered Base Speaker Configuration: 1 HYBRID BANDPASS
way 18"Built-in amplifier LF/HF: 1200 W RMS Built-in amplifier peak
LF/HF: 2400 W Frequency response: 33Hz-100Hz -6dB Low Frequency
woofer: 1X18 - 3.5 coil - neodymium inch Maximum SPL cont/peak:
135/139 half-space dB Dispersion: Omnidirectional HxV Input impedance: Nos 2.00 208348.00 416696.00
22 Kohm Crossover Frequency: preset dependant KHz AC Power
requirements: 640 VA Input connector: XLR with loop Power cord: 5/ 16.4
m/ft Net Dimension (WxHxD): 652x500x750 / 25.66x 19.68x29.52
mm/inch Net Weight: 67/147.70 kg/lb(FBT-Muse 118FSA)
Supply of Flying bar Indian (Customised) with 1 ton chain pully Nos 2.00 35988.00 71976.00
S.N. DESCRIPTION OF ITEM UNIT QUANTITY RATE AMOUNT
Supply of Stage Monitor Supply of Stage monitor 2-way, bi-amp. bass
reflex design, 400+100W rms Class D amp., 60Hz-20KHz freq resp, 12"
B&C coax custom woofer, 1" B&C HF driver, DSP 4 presets, 130dB SPL Nos 2.00 68818.00 137636.00
max, Disp 90°, gas-injection polyprop molded enclosure (FBT-STAGEMAX
Supply of Digital Audio mixer 24 mono mic inputs 4 line inputs 66 inputs
to mix 1 ViSi Connect™ option card slot for 64 x 64 input/output
expansion Freely assignable faders and patching Pre/Post selection per
input per bus AES in and out Global mode encoders Soundcraft
FaderGlow™ GEQ on every bus 20 sub-group / aux busses 4 FX busses 8 No. 1.00 220379.00 220379.00
Matrix busses LR and C Mix busses 4 Stereo Lexicon Effects engines
Delay on inputs and outputs 4 Mute Groups Freely assignable insert loops
Harman HiQnet integration Colour touch screen interface (Si Expersion-
2)(Allen Heath QU 24)
Supply of Corded microphone (Shure-SM58/FBT/sennheiser) Nos 2.00 9154.00 18308.00
Supply of Instrument Microphone(Shure-57/FBT/sennheiser) Nos 2.00 9678.00 19356.00
Supply of Podium Microphone (Shure/FBT-GM5218L/AKG) Nos 2.00 28411.00 56822.00
Supply of Microphone Stand Big(GS) Nos 2.00 1124.00 2248.00
Supply of Microphone Stand Small(GS) Nos 2.00 843.00 1686.00
Supply of microphone cable from stage to control room for microphone
points with conduit pipe etc. (PLS/Tasker/Krystal)
Supply of Speaker 2.5sqmm x3core(Incol/Polycab/Kalinga/Incoil) Mtr 200.00 114.00 22800.00
Supply of microphone connecting box made out from CRC sheet metal
box duly powder coated paint,with 6 nos XLR panel mounting socket & Nos 4.00 6322.00 25288.00
phono socket having the facility to connect the 6nos microphone channel.
Supply of Professional Head phone(German Meastro/Sennheiser) Nos 1.00 7170.00 7170.00
Supply of Microphone cable XLR to XLR up to 10 Mtr(PLS) Nos 15.00 1265.00 18975.00
Supply of Microphone cable XLR to XLR up to 15 Mtr(PLS) Nos 15.00 1861.00 27915.00
Supply of Speaker connectin connector & MCB Box for Speaker etc Lot 1.00 63135.00 63135.00
Installation charges Job. 1.00 200000.00 200000.00
Proposal for Projection Auditorium Solutions 0.00 0.00
Hitachi CPX5022 Brightness 5000 Lumens with Standard Lens , Throw
distance 19.5Feet to 31.5 Feet ,Screen Size 8x13 minimum size. Warranty Nos 1.00 241821.00 241821.00
Motorized Projection Screen with Remote Control, Matt White Draper
Fabric, Size 12x9 Feet. Warranty 5 Years
HDMI to CAT6 Transmitter & Receiver with HDMI to CAT 6 Ports upto 150
Mtrs at Stage to Contro, Room with Audio, Warranty 5 Years.
Multimedia Switcher HDMI at Control Room Switcher 4 Input 1 Output
with Audio oUtput
Supply of cat 6 cable stage to contro room (Amp /Belden) Mtr 280.00 68.00 19040.00
Cables & Connectors HDMI,CAT6 & Power ,Warranty 5 Years Nos 1.00 29781.00 29781.00
Ceiling Mount Kit , Warranty 5 Years Nos 1.00 4355.00 4355.00
Installation & Commissioning Nos 1.00 58438.00 58438.00
SUB-TOTAL AMOUNT 2239181.00
SUB-TOTAL AMOUNT 2239181.00
SITE DEVELOPMENT WORK 0.00 0.00
A COST OF BITUMINOUS ROAD 0.00 0.00
Preparation and consolidation of sub grade with power road roller of 8 to
12 tonne capacity after excavating earth to an average of 22.5 cm depth,
16.1 dressing to camber and consolidating with road roller including making Sqm 1540.00 190.17 292869.19
good the undulations etc. and re-rolling the sub grade and disposal of
surplus earthwith lead upto 50 metres.
16.3.1 Supplying and stacking at site. cum 146.37 2041.46 298807.82
90 mm to 45 mm size stone aggregate
16.3.2 Supplying and stacking at site cum 97.58 1711.57 167015.31
63 mm to 45 mm size stone aggregate
Laying, spreading and compacting stone aggregate of specified sizes to
WBM pecifications in uniform thickness, hand picking, rolling with 3
16.4 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper cum 97.58 912.21 89013.15
grade and camber, applying and brooming requisite type of screening /
binding material to fill up interstices of coarse aggregate, watering and
compacting to the required densi
Laying, spreading and compacting stone aggregate of specified sizes to
WBM pecifications in uniform thickness, hand picking, rolling with 3
16.4 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper cum 73.19 912.21 66759.86
grade and camber, applying and brooming requisite type of screening /
binding material to fill up interstices of coarse aggregate, watering and
compacting to the required densi
16.3.6 Supplying and stacking at site cum 48.79 1964.96 95870.59
Stone screening 13.2 mm nominal size (Type A)
16.3.7 Supplying and stacking at site cum 14.64 2176.42 31856.28
Stone screening 11.2 mm nominal size (Type B)
16.3.8 Supplying and stacking at site cum 9.76 1640.72 16010.13
16.3.10 Supplying and stacking at site cum 8.76 935.91 8198.60
2.5 cm premix carpet surfacing with 2.25 cum and 1.12 cum of stone
chippings of 13.2 mm and 11.2 mm size respectively per 100 sqm and 52
kg and 56 kg of hot bitumen per cum of stone chippings
of 13.2 mm and 11.2 mm size respectively, including a tack coat with hot
16.33.1 straight run bitumen, including consolidation with road roller of 6 to 9 Sqm 975.80 239.17 233379.35
tonne capacity etc. complete (tack coat to be paid for separately).
With paving Asphalt grade VG - 10 heated and then mixed with solvent at
the rate of 70 grams per kg of asphalt
Brick edging in full brick width and half brick depth including excavation,
16.7.1 refilling and disposal of surplus earth lead upto 50 metres. With common Mt. 557.60 189.12 105453.98
burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and applying tack coat using hot straight run bitumen of grade
VG - 10, including heating the bitumen, spraying the bitumen with
16.30.1 mechanically operated spray unit fitted on bitumen boiler, cleaning and Sqm 975.00 47.62 46432.15
preparing the existing road surface as per specifications :
On W.B.M. @ 0.75 Kg / sqm
S.N. DESCRIPTION OF ITEM UNIT QUANTITY RATE AMOUNT
Providing and laying seal coat of premixed fine aggregate ( passing 2.36
mm and retained on 180 micron sieve) with bitumen using 128 kg of
16.40 bitumen of grade VG - 10 bitumen per cum of fine aggregate and 0.60 Sqm 975.00 84.13 82026.71
cum of fine aggregate per 100 sqm of road surface, including rolling and
finishing with road roller all complete
Excavating, supplying and filling of local earth (including royalty) by
2.25a mechanical transport upto a lead of 5km also including ramming and cum 237.35 388.41 92189.03
watering of the earth in layers not exceeding 20 cm in trenches, plinth,
sides of foundation etc. complete.
CONSTRUCTION OF PATHWAY 0.00 0.00
Earth work in excavation by mechanical means (Hydraulic excavator) /
manual means over areas (exceeding 30cm in depth. 1.5 m in width as
well as 10 sqm on plan) including disposal of excavated earth, lead upto 0.00 0.00
50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.
all kinds of soil Cum 32.89 216.46 7119.44
Providing and laying in position cement concrete of specified grade
excluding the cost of centering and shuttering. All work upto plinth level. 0.00 0.00
1:5:10 (1 cement : 5 course bound: 10 graded stone aggregate 40mm Cum 33.93 6374.96 216302.56
Providing and laying 60mm thick faciory made cement concrete
interlocking paver block of M -30 grade made by block making machine
with strong vibratory compaction, of approved s;ze, design & shape, laid
in required colour and pattern over and including 50mm thick compacted Sqm 348.00 1001.97 348686.81
bed of coarse sand, filling the joints with line sand etc. all complete as per
the direction of Engineer-in-charge.
Providing and laying at or near ground level factory made kerb stone of M-
25 grade cement concrete in position to the required line, level and
curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand),
ncluding making joints with or without grooves (thickness of joints except
at sharp curve shall not to more than 5mm), including making drainage Cum 23.49 9075.24 213177.30
opening wherever required complete etc. as per direction of Engineer-in-
charge (length of finished kerb edging shall be measured for payment).
(Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Painting with synthetic enamel paint of approved brand and manufacture 0.00 0.00
of required colour to give an even shade :
Two or more coats on new work over an under coat of suitable shade with Sqm 52.20 201.66 10526.60
ordinary paint of approved brand and manufacture
Excavating, supplying and filling of local earth (including royalty) by
mechanical transport upto a lead of 5km also including ramming and
watering of the earth in layers not exceeding 20 cm in trenches, plinth, Cum 93.96 388.41 36494.97
sides of foundation etc. complete.
Filling available excavated earth (excluding rock) in trenches, plinth, sides
of oundations etc. in layers not exceeding 20cm in depth, consolidating Cum 3.70 267.56 989.98
each deposited layer by ramming and watering, lead up to 50 m and lift
Centering and shuttering including strutting, propping etc. and removal of 0.00 0.00
form for all heights :
Foundations, footings, bases of columns, etc. for mass concrete. Sqm 55.68 324.46 18065.72
SEPTIC TANK (100 USER'S)Size of Tank = 5.70 X 2.10 X 1.70 Mtr 0.00 0.00
Excavation work by mechanical means (Hydraulic excavator)/ manual
means in foundation trenches or drains (not exceeding 1.5m in width or
10 sqm on plan), including dressing of sides and ramming of bottoms, lift 0.00 0.00
upto 1.5 m, including getting out the excavated soil and disposal of
surplus excavated soils as directed, within a lead of 50 m.
all kinds soil cum 97.85 302.23 29572.73
Excavation work by mechanical means (Hydraulic excavator)/ manual
means in foundation trenches or drains (not exceeding 1.5m in width or
10 sqm on plan), including dressing of sides and ramming of bottoms, lift 0.00 0.00
upto 1.5 m, including getting out the excavated soil and disposal of
surplus excavated soils as directed, within a lead of 50 m.
Earth work in Excavation 1.50-3.00 mtr 0.00 0.00
all kinds soil Cum 19.57 110.10 2154.68
ordinary rock Cum 19.57 197.44 3863.99
Filling available excavated earth (excluding rock) in trenches, plinth, sides
of foundations etc. in layers not exceeding 20cm in depth, consolidating Cum 59.59 267.56 15944.27
each deposited layer by ramming and watering, lead up to 50 m and lift
Providing and laying in position cement concrete of specified grade
excluding the cost of centering and shuttering - All work up to plinth level 0.00 0.00
1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate Cum 2.19 6374.96 13961.17
40 mm nominal size).
Providing and laying in position machine batched and machine mixed
design mix M-25 grade cement concrete for reinforced cement concrete
work, using cement content as per approved design mix, including
pumping of concrete to site of laying but excluding the cost of centering,
shuttering, finishing and reinforcement, including admixtures in
recommended proportions as per IS: 9103 to accelerate, retard setting of Cum 15.72 9149.25 143826.24
concrete, improve workability without impairing strength and durability as
per direction of Engineer-in-charge.“(Note :- Cement content considered in
this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is
payable/recoverable separately).
Centering and shuttering including strutting, propping etc. and removal of 0.00 0.00
Foundations, footings, bases of columns, etc. for mass concrete. Sqm 94.59 324.46 30690.30
Lintels, beams, plinth beams, girders, bressumers and cantilevers. Sqm 5.42 640.96 3473.99
Suspended floors, roofs, landings, balconies and access platform. Sqm 11.97 807.64 9667.42
Edges of slabs and breaks in floors and walls. Mtr 17.11 191.65 3279.13
Reinforcement for R.C.C. work including straightening, cutting, bending, 0.00 0.00
placing in position and binding all complete.
Thermo-Mechanically Treated bars. Kg 1572.00 94.46 148483.64
S.N. DESCRIPTION OF ITEM UNIT QUANTITY RATE AMOUNT
52 mm thick cement concrete flooring with concrete hardener topping
under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse
sand : 4 graded stone aggregate 20mm nominal size) and top layer
12mm thick cement hardener consisting of mix 1:2 (1 cement hardener
mix : 2 graded stone aggregate 6mm nominal size) by volume. Hardening Sqm 12.00 901.78 10821.31
compound is mixed @ 2 litre per 50kg of cement or as per manufactures
specifications. This includes cost of cement slurry, but excluding the cost
of nosing of steps etc. complete.
6 mm cement plaster on rough side of single or half brick wall of mix: 0.00 0.00
Providing and fixing in position pre-cast R.C.C. manhole cover and frame Nos 2.00 1574.29 3148.58
of required shape and approved quality
Providing orange colour safety foot rest of minimum 6 mm thick plastic
encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS :
1786 having minimum cross section as 23 mmx25mm and over all
minimum length 263 mm and width as 165mm with minimum 112 mm
space between protruded legs having 2 mm tread on top surface by
ribbing or chequering besides necessary and adequate anchoring
projections on tail length on 138 mm as per standard drawing and suitable
to with stand the bend test and chemical resistance test as per
specifications and having manufacture’s permanent identification mark to
be visible even after fixing, including fixing in manholes with 30x20x15 cm
cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone
aggregate 20 mm nominal size) complete as per design.
Providing and fixing soil, waste and vent pipes,100 mm dia.Centrifugally
cast (spun) iron socketed pipe as per IS: 3989.Inlet + outlet,Vent Pipe Mtr 7.43 1135.15 8434.15
Providing and fixing terminal guard :100 mm(Sand cast iron S&S as per IS Nos 1.00 463.32 463.32
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick
honey comb shaft with bricks of class designation 75 and S.W. drain pipe Nos 2.00 29531.51 59063.02
100 mm diameter, 1.8m long complete as per standard design.With F.P.S.
SURFACE DRAIN 0.00 0.00
Earth work in excavation by mechanical means (Hydraulic
excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in
1 width as well as 10 sqm on plan) including getting out and disposal of 0.00 0.00
excavated earth lead upto 50 m and lift upto 1.5 m, as directed by
Engineer-in-charge.
all kinds of soil cum 64.50 216.46 13961.81
Filling available excavated earth (excluding rock) in trenches, plinth, sides
2 of foundations etc. in layers not exceeding 20cm in depth: consolidating cum 17.20 267.56 4602.06
each deposited layer by ramming and watering, lead up to 50 m and lift
Providing and laying in position cement concrete of specified grade
3 excluding the cost of centering and shttering - All work up to plinth level 0.00 0.00
1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate cum 17.42 6374.96 111020.01
40 mm nominal size).
1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources :
4 4 graded stone aggregate 40 mm nominal size derived from natural cum 6.45 7614.31 49112.33
5 Centering and shuttering including strutting, propping etc. and removal of 0.00 0.00
form for all heights :
Foundations, footings, bases of columns, etc. for mass concrete Sqm 43.00 324.46 13951.61
6 Brick work with F.P.S. bricks of class designation 75 in foundation and 0.00 0.00
Cement mortar 1:6 (1 cement : 6 coarse sand) Cum 15.05 7015.13 105577.74
7 12 mm cement plaster finished with a floating coat of neat cement of mix 0.00 0.00
SUB-TOTAL AMOUNT 3347309.68
SUB-TOTAL AMOUNT 3347309.68
GRAND TOTAL 64553032.84
GRAND TOTAL 64553032.84
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT003.pdf
Tender Document
GCC.pdf
Tender Document
BOQ.pdf
Tender Document
Signed IP.PDF
Tender Document
MAKE LIST.pdf
Tender Document
Physical Milestone.pdf
Tender Document
Drawings.pdf
Tender Document
Amendment05.pdf
Tender Document
addendum-af3acc0fb439-Angul.pdf
pdf • 0.22 MB
corrigendum-1764-Corrigendum01Angul.pdf
pdf • 0.07 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .