Loading…
Loading…
Tender ID
Tender Value
₹48.0 L
EMD Value
₹96,100
Closing Date
10 Mar 2026, 12:00 pmClosed
ADDITIONAL EXECUTIVE OFFICER
BIRBHUM ZILLA PARISHAD, SURI, BIRBHUM, 731101
Construction of Su-Swasthya Kendra (Health and Wellness Center) (HWC Type-A) at Hatkalua within Labpur Block
2026_ZPHD_1013340_4
WBZP-BHM-N-92-2025-26
Open Tender
CIVIL WORKS
Percentage
180 days
SURI
As Per NIT
7 documents required · 7 mandatory
₹5,000
₹96,100
25 Feb 2026
25 Feb 2026
12 Mar 2026
25 Feb 2026
10 Mar 2026
25 Feb 2026
BIDDER INFORMATION FORM v3 BIRBHUM ZILLA PARISHAD
1 Name of the Bidder
2 Bid submitted for (NIT No)
5 BIDDERS DETAILS
(a) Address for communication
(b) Contact No. (Mobile)
(C) e-mail Address
(d) Professional tax registration No.
(e) Professional Tax Clear Upto
(f) GST Registration No.
(g) GST return submitted upto
(i) Income tax return submitted Upto
(j) Trade License (Last valid)
(a) Name of drawee bank
(b) e Proc Ref No.
(d) NEFT/RTGS / Net banking Ref No
(f) Tender Processing fees Ref No.
(g) Tender Processing fees Date
7 Credential for similar nature of work. (To be supported with work order & completion report / Payment Certificate)
(a) Name of Work executed
(c) Name of Department where executed
(d) Amount put to tender
(e) Amount of final Bill
(f) Work order No.
(g) Date of Completion
* NB- Filled up properly & Upload in .xls format.
Tender Sechedule for " Construction of Su- Sasthya Kendra ( Health & Wellness Center) (HWC Type -A) at Hatkalua within Labpur Block "
NIT No. : BHM/N-92/2025-26 (2nd Call) Sl No : 04
Sl No. Items of work Qnty Unit Rate Amount (Rs)
1 Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed. 107.35 sqm 10
2 Clearing compound premises of shurbs, plants, jungles etc by cutting and removing as directed (Specific permission of Engineer-in-Charge prior to execution will be necessary). (Payment to be made on area cleared) 123.24 sqm 11
3 Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.
a) Depth of excavation not exceeding 1,500 mm. 99.07 cum 119.27
4 Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)
a) With earth obtained from excavation of foundation. 0.000 cum 1437
5 A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) 0.000 cum 17978
6 Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches. 50 sqm 24
7 Pre-Constructional Anti-termite measures:
a) Anti termite treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water by weight at the rate of 5 Litres per sq. m. of the surface before sand bed or sub-grade is laid. Holes upto 50 mm. to 75 mm. deep at 150 mm. centre to centre both ways shall be made with 12 mm, diameter mild steel rod on the surface to facilitate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in para 6.4 of code IS- 6313 (part -II) 1981. ( Mode of measurment will be per Sq.m of plan area of plinth treated.) 66.84 sqm 110
b) Treatment to the back filling of R.C.C. foundation with chemical emulsion by admixing chloropyrofos emulsifiable concentrate (1% concentration) with water by weight at the rate of 7.5 ltr. per sq.m. of the vertical surface of the substructure of each side of the foundation. The work shall be carried out as per specification as described in para 6.3.1 of code IS- 6313 (part-II) 1981 (Mode of measurement will be per sq.m. of vertical area of foundation treated). 76.44 sqm 137
8 25mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer's specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface). [Note: - Waterproofing as per item 9, polymer based paint as per item 8 (a) of subhead C of Section (C). 3.53 sqm 169.16
9 Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand. 254.35 sqm 266
10 Cement concrete (1:3:6 proportion) with graded stone ballast (40 mm. size) excluding shuttering.
a) [Pakur Variety]
i) In Ground floor 12.04 cum 4105.5
11 Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.
a) [Pakur Variety]
i) In Ground floor 5.85 cum 4475.82
12 Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes
a) M-20 grade with Pakur variety
i) In ground floor and foundation. 0.000 cum 4976.83
ii) In first floor 0.000 cum 5071.83
ii) In second floor 4.16 cum 5166.83
13 Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction.
a) Other Than Sail/tata
i) In foundation & ground floor 0.000 MT 55015.62
ii) In first floor 0.000 MT 55455.62
iii) In second floor 0.49 MT 55875.62
14 Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works.
c) Steel shuttering or 9 to 12 mm. thick approved quality ply board shuttering in any concrete work
i) In foundation & ground floor 0.000 sqm 363
ii) In 1st floor 178.93 sqm 381
iii) In 2d floor 0.000 sqm 399
15 Brick work with 1st class Bricks with cement morter (1:6)
(a) In foundation and plinth 18.39 cum 4198.04
(b) In superstructure, ground floor 0.000 cum 4421.04
(c) In 1st floor 0.000 cum 4532.04
(d) In 2d floor 5.56 cum 4643.04
16 125 mm. thick brick work with 1st class bricks in cement mortar (4:1)
i) In ground floor 93.89 sqm 584.5
ii) In 1st floor 105.72 sqm 596.5
iii) In 2d floor 0.000 sqm 608.5
17 Labour for Chipping of concrete surface before taking up Plastering work. 130.24 sqm 21
18 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary.
a) 20 mm. thick plaster (6:1)
i) In ground floor 0.999 sqm 149.74
ii) In first floor 0.999 sqm 153.74
iii) In second floor 0.999 sqm 157.74
b) 15 mm. thick plaster (6:1)
i) In ground floor 0.000 sqm 132.54
ii) In first floor 0.999 sqm 136.54
iii) In second floor 0.000 sqm 140.54
c) 10 mm. thick plaster (4:1)
i) In ground floor 0.999 sqm 119.54
ii) In first floor 0.000 sqm 123.54
iii) In second floor 12.44 sqm 127.54
19 Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m. 36.93 sqm 32.74
20 Artificial stone in floor, dado, staircase etc with cementconcrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75kg/sq.m all complete including all materials and labour.In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).Using grey cement
(ii) 25 mm. thick
i) In ground floor 69.44 sqm 240.02
ii) In first floor
iii) In second floor 61.56 sqm 247.27
21 Extra cost of labour over grey artificial stone for
(i) Chequering 61.56 sqm 15
22 Extra rate for using water proofing and plasticising admixture @ 0.2% by weight of cement (or at manufacturer's specified rate) for concrete of various grades. 61.56 kg 119
23 Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive(6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contrr] e) I
(I) With application slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment.
(B) Light Colour at Ground Floor 47.43 sqm 1252.43
at First Floor 0.000 sqm 1257.43
24 18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m] at ground Floor 0.000 sqm 1003
First Floor 0.999 sqm 1015
25 Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.
With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.
(a) Area of each tile upto 0.09 Sq.m
(i) Coloured decorative (Ground Floor) 11.52 sqm 682.43
First Floor 9.15 sqm 687.43
With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.
(a) Area of each tile upto 0.09 Sq.m
(i) Coloured decorative (Ground Floor) 55.77 sqm 688.43
First Floor 35.08 sqm 693.43
26 Rendering the surface of walls and ceiling with white cement based wall putty (thickness not less than 1.5 mm.)
i) In ground floor 0.999 sqm 122
27 Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface.
a) Two coats 0.999 sqm 70
28 Applying Exterior grade Acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive decorative textured( matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC.
i) In ground floor 0.999 sqm 45.1
ii) In first floor 0.999 sqm 45.81
iii) In second floor 0.999 sqm 46.52
29 Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.
i)Super Protective 100% Acrylic Emulsion.
i) In ground floor 0.999 sqm 97
ii) In first floor 0.999 sqm 97.71
iii) In second floor 0.999 sqm 11038
30 Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria (i) 66mm x 90mm 19.8 Mtr. 497
31 Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria. (ii) 25 mm thick
i) In ground floor 3.15 Sqm 2581
ii) In first floor 3.15 Sqm 2595
iii) In second floor 0 Sqm 2609
32 Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete.
i) In ground floor 4.41 sqm 4330
33 M.S. gate of Jail type as per approved design made of strong M.S. frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge.
i) In ground floor 0 Qutl. 10090
ii) In first floor 0 Qutl. 10190.9
iii) In second floor 0.000 Qutl. 4868
34 (a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs .
(i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.
i) In ground floor 0.000 Qutl. 9888
ii) In first floor 0.999 Qutl. 31978
iii) In second floor 0 Qutl. 10086.75
35 Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-in-charge. Weight of Strainless Steel railing per metre 6.5 Kg (approx) 14.2 Mtr. 9077
36 Priming one coat on steel or other metal surface with synthetic enamel/ oil bound primer of approved quality including smooth ening surfaces by sand papering etc. 68.59 sqm 29
37 Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary with super gloss (hi-gloss) -
b) On steel or other metal surface :
i) Two coats (with any shade except white) 68.59 sqm 79
38 Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fixing of glass (excluding cost of glass) all complete as per architectural fitting & fixing of aluminium 2-track/3-track sliding window with drawings and direction of Engineer-in-charge.
10-12 Micron thickness Annodizing film
i) Natural White
a) 2-track sliding window + b) 3-track sliding window 112.86 kg 448
39 Supplying, fitting & fixing of partly glazed partly panelled or fully glazed single leaf Aluminium swing door of all aluminium sections viz door frame ( top and side frame), shutter( top rail, bottom rail, lock rail, door vertical),glazing clip made of Aluminium Alloy Extrusions conforming to IS: 733-1983 and IS: 1285-1975, annodized conforming to IS:1868-1983, fitted with all other accessories viz. EPDM gusket,cleat, angle screws etc. including labour charges for fitting and fixing of aluminium door with door spring,/aluminium hinges, glass / Panel board all complete as per architectural drawings and direction of Engineer-incharge. ( Excluding cost of glass/ panel board, door spring/ Al hinges, door closer, door stoper, handle, tower bolt and locking arrangment etc) 10-12 Micron thickness Annodizing film Natural white 232.47 kg 385
40 Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In-Charge. (Payment will be made on finished length of the work).
(A)10-12 Micron thickness annodizing film
i) Natural White
h) Louvered window
i) Top, bottom and side member 7.2 Metre 183
ii) Louvered Section 3.24 Metre 658
iii) Cleat angle ( Non-annodized) 3.24 Metre 263
g) Fixed glazing
i) Top, bottom and side member. 9 Metre 321
ii) Mullion. 9 Metre 339
iii) Glazing clip. 1.62 Metre 50
41 Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 205/66) and fitted and fixed with cadmium plated screws:
(vii) 100x75x4.00 mm 74 Each 93
42 Supplying 4 lever mortice lock of any approved make and brand as per direction of the Engineer-in-Charge.
(a) 100 mm 12 Each 212
43 Labour charges for fabrication and installation of composite door, window, partitions made from annodized extruded alloy aluminium sections for the following units
(iv) fixed glazing 1.62 sqm 768
(v) Louvered window 1.08 sqm 730
44 Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987.
i) 4mm thick clear glass. 0.999 sqm 398
vi) 6mm thick coloured / tinted / smoke glass. 0.72 Sqm 661
viii) 8mm thick coloured / tinted / smoke glass. 6.28 sqm 907
45 Supplying and affixing optically clear polyester sun control window film having acrylic pressure sensitive adhesive on one side & an acrylic abrasion resistant coating on the other, with composition of infrared absorbing carbon & free from any optical defect. The film characteristics should conform to ASTM E308, ASTM E903, ASTM E84 and ASHIRAE. The film should be pasted after preparatory works without any cracking, delamination, bubbling, discolouring and variation in total transmission of light across the width at any portion along the length doesn't exceed 2% over the average including scaffolding & relevant others to complete in all respect as per manufacturer's specification & direction of Engineer -in-Charge. (Note: This work should not be executed without specific permission of Superintending Engineer)
(a) Normal Quality : Film Thickness - 1.0 Mil, Glare Reduction > 45%, U factor < 1.15 0.72 Sqm 326
46 Providing, fitting and fixing in position, medium density fibre board conforming to IS: 12406-1988 for plain and IS: 14587-1998 for prelaminated made of wood fibre bonded with Urea formaldehyde for interior grade and Phenol Formaldehyde for exterior grade conforming to per IS:848-1974 as per approved make and brand as per direction of Engineer-in-Charge.
(C) Both side decorative lamination
(II) Interior Grade
i) In Ground Floor 6.31 sqm 880
ii) In First Floor 4.59 sqm 894
47 Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete:
(a) With continuous plate base (Hexagonal/ Round rod)
(iv) 125 mm grip x 10 mm dia rod. 28 Each 95
48 Supplying, fitting & fixing Stainless Steel 'D' or 'H' type of size 300 mm x 19 mm tubular Handle with Grade 304, CE certified, marked & conforming to EN - 1154, of approved quality of reputed brand as per direction of Eingineer-in- Charge fitted and fixed complete including all incidental charges. 2 Each 1571
49 ii) Godrej Hydraulic door closer fitted and fixed complete.
(b) Medium type 1 Each 1665
50 Anodized aluminum barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws:
(vii) 225mm long x 10mm dia. bolt 17 Each 84
(iv) 150mm long x 10mm dia. bolt. 14 Each 63
51 i) Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting
(b) 250mm long. 15 Each 159
52 Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete.
(ii) 110 mm. Dia. 48 Mtr. 251
(ii) 110 mm. Dia. 8 No. 172
(ii) 110 mm. Dia 4 No. 223
c) Bend 87.5 degree
(ii) 110 mm. Dia. 8 No. 160
(ii) 110 mm. Dia. 8 No. 111
53 Providing and fixing exterior quality Aluminium Composite Panel (ACP) wall cladding on existing Al. /MS frame work with GI brackets, ACP fixed on the existing frame work by folding the edges of ACP anel (Engraving the rear surface of ACP sheet) with CP angles, cleats and strainless Steel screws forming groves at the periphery of ACP panel. Such grooves filled with foam and silicon sealant etc. complete with all materials (but including the cost of silicon sealant), labour, scaffolding and all other incidental charges complete in all respect as per specification and direction of Engineer-in-charge. (Mode of payment is on finished surface area of ACP)
3mm thick (0.25mm Al.+2.5mm LDPE +0.25mm Al. PVDF coating 0.999 Sqm 1991
54 Supplying, fitting and fixing Black Stone slab used in Kitchen slab, alcove, wardrobe etc. laid and jointed with necessary adhesive Cement mortar (1:2) including grinding or polishing as per direction of Engineer-in -Charge in Ground Floor. (a) Slab Thickness 20 to 25 mm 0.000 Sqm 643
55 Supplying,fitting & fixing granite slab 15mm to 18mm thick in floor, lobby, stair, landing and treads etc. over 20mm (avg) thick base of cement morter (1:2) laid with white cement slurry @ 4.40Kg per Square meter before placing of granite and jointed with white cement slurry @ 2.0 Kg per square meter with necessary pigments and complete as per direction of Engineer-in-charge including cost of all materials, labours, curing and roughening of concrete surface complete. In ground floor (c) Area of each Granite slab above 1.00 Square meter. 1.8 Sqm 2999
56 Supplying, fitting & fixing of Aluminium fixed partion wall of all aluminium sections viz top, bottom and side member, intermediate member, glazing clip made of Aluminium Alloy Extrusions conforming to IS: 733-1983 and IS: 1285-1975, annodized conforming to IS:1868- 1983, fitted with all other accessories viz. EPDM gusket,cleat, angle screws etc. including labour charges for fitting and fixing of aluminium fixed partition wall with glass / panel board all complete as per architectural drawings and direction of Engineer-in-charge. (Excluding cost of glass/ panel board, 10-12 Micron thickness Annodizing film. Natural white. a) for unsupported length of vertical member upto 1.50m. height of both ends of vertical member restrained but panel with in 0.90 sqm (unit wt of Top, bottom & side member @1.366 kg/m ; intermediate member @ 1.443 kg/m; glazing clip: 0.167 kg/m respectively) [Note : for estimate purpose construction wing may consider weight of Al-Sections for Partition wall @ 5.7 Kg per Sq.M] 0.999 Kg 391
b) For unsupported length of vertical member above 1.50m. height of both ends of vertical member restrained but panel above 0.90 sqm (unit wt of Top, bottom & side member @ 1.978; intermediate member @ 2.055; glazing clip @ 0.167 kg/m respectively) [Note : for estimate purpose construction wing may consider weight of Al-Sections for Partition wall @ 5.0 Kg per Sq.M] 2.85 Kg 387
57 M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-in- charge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. I) For structural members of specified sections weighing less than 22.5 Kg./m 0.03 MT 72603
58 Holding down bolt with nut including 100 x 100 x 6 mm plate washer at bottom fitted complete and packing the hole with cement concrete or cement grout as directed. (i) 16 mm dia bolt (a) 300 mm long 16 Each 120
59 Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification Clause 801 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). 3125 Cm 0.5
Sanitary & Plumbing
60 Supplying, fitting and fixing PVC pipes of approved make of Schedule 80(medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew,reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc.complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately
(b) For Exposed Work
40 mm 18 mtr 292
(b) For Concealed Work
15 mm 35 mtr 137
20 mm 25 mtr 158
25 mm 16 mtr 205
61 supplying ,fitting and fixing peets valve fullway gunmetal standard pattern best quality of approved brand bearing isi markings with fittings (tested to 21 kg per sq.cm)
(ix)15 mm dia 2 each 521
viii) 20mm 2 each 657
(vii) 25 mm dia 2 each 912
62 Supplying, fitting and fixing bib cock or stop cock.
(a)i) chromium plated bib cock short body (equivalent to code no. 511 & model- tropical./ sumthing special of ESSCO or similar brand) 5 each 539
(d)i) chromium plated angular stop cock with wall flange (equivalent to code no. 5053 & model- Florentine of Jaquar or similar brand) 5 each 815
63 Supplying P.V.C water storage tank of approved quality with closed top with lid(black)-Multilayer.
(c) 1500 litre capacity 1 each 7840
64 Labour for hoisting plastic water storage tank. 1 each 139
65 Supplying fitting & fixing 10 ltr. PVC low down cistern conforming to I.S specification with PVC fittings complete C.I brackets including two coats of painting to bracket etc. 4 each 1015
66 Labour for punching hole in plastic water storage tank up to 50 mm dia. 2 each 19
67 Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint.
ii) 550 mm X 400 mm size 7 each 2208
(iv) Angle back wash basin 400 mm X 400 mm 1 each 2034
68 Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets.
530 mm X 430 mm x 180 mm 3 each 3285
69 Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P.nut,15 mm dia.
i) 450mm long 4 each 82
70 Suppling fitting & fixing approved brand 32mm dia p.v.c waste pipe with p.v.c coupling at one end fitted with necessary clamps
i)900mm long 7 each 75
71 Suppling fitting & fixing 15 mm swan neck tap with left & right hand operating knob with aerator. 5 each 811
72 Suppling fitting & fixing with cement jointing (3:1) salt glazed stoneware pipe including excavation of earth upto 1.50 m depth in all sorts of soil both mixed or un mixed and refilling (but excluding concerting at bottam and sides) i)150 mm. 25.3 Mtr 334
73 Suppling fitting & fixing with cement jointing (3:1)with jute gasket soaked in cement mortar.
a)stoneware bend
ii)150 mm 8 each 350
b)stoneware single T & Y junction
ii)150 mm 5 each 447
74 Suppling fitting & fixing c.i round grating
i)100mm 9 each 62
75 Supply of UPVC pipes (B type )& fitting conforming to IS 13592-1992
A) i) single socketed 3 mtr length --
b)110 mm 24 Mtr 292
76 (ii) Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineer-in-charge. (Payment will be made on centre line measurement of the total pipeline including specials.
A) Above ground
(ii) 110 mm dia. 14 Mtr 57
A) Under ground
(ii) 110 mm dia. 10 Mtr 84
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992
viii) Double Y with Door
b) 110 mm 3 each 345
xi) door bend ( T.S.)
b) 110 mm 11 each 147
xv) vent cowl -(b) 110mm 1 each 33
xvi) pipe clip ---(b) 110 mm 12 each 21
(ii) Plain Tee ---(b) 110 mm 6 each 85
78 Suppling fitting & fixing E.W.C in white glazed vitreous china ware of approved make supplied fittied complete in position with necessary bolts nuts.etc.
a)with 'P' trap 4 each 1421
79 Supplying fitting & fixing closet seat of approved make with lid & C.P hinges,rubber beffer & brush screw complete.
(a) E.W.C. (ii) Plastic (hallow type) white 4 each 380
80 Supplying fitting & fixing 32 mm. dia. flush pipe of approved make with necessary fixing materials & clam complete.
i)Polythene flush pipe. 4 each 155
81 (i) Supplying, fitting and fixing liquid soap container
c) fibre glass 5 each 188
82 Supplying fitting & fixing best quality indian make mirror 5.5 mm thk. With silvering as per I.S.I specification supported on fibre glass frame of any colour,frame size 550mm x 400mm 5 each 613
83 Supplying fitting & fixing towel rail with two brackets.
a)C.P over brush--- i)25mm dia,450 mm long. 5 each 384
84 constructing inspection pit of inside measurement 600mm x600mm x upto 600mm (depth) with 250mm th. 1st. Class brick work in cement mortar(1:4) on all sides bottom of the pit consisting of 100 mm th. Cement concrete (1:3:6) with stone chips over a layer of jhama brick fklat soling, 15 mm thk. (4:1) cement plaster to bottom of the pit providing necessary invert with cement concrete (1:3:6) with stone chips as per direction ,neat cement finishing to entire internal surface top of the pit convered with 100 mmth. R.CC slab (1:1.5:3) with stone chips and necessary reinforcement upto 1% and shuttering including 6mm thk.cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia .R.C.C manhole cover of approved make supplied ,fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth removing spoils after work complete in all respect with all costs of labour and materials. i) With pakur variety (SAIL/TATA/RINL) 4 each 6168
85 Construction of circular soak well 2.5 m deep inall types of sandy soils with dry brick work upto 1:6 m from the bottom having 150mm intermediate cement brick work(1:4) band all round and cement brick work (1:4) upto .90m from top with 20mm thk. Cement plastering (4:1) to inside face upto the depth of cement brick work, 15 mm th.cement plaster (1:4)on outer face from top of the well upto G.L and 6mm thk. cement plaster (1:4) on top of the R.C.C cover slab including filling bottom 1.0m of inside of the well with brick metal (501mm to 63mm size) including R.CCcover slab of designed thk. with cement concrete b(1:1.5:3) with stone chips with necessary. reinforcement and shuttering including one 560 mmdia .R.CC manhole cover(heavy type) of approved make supplied ,fittings making necessary arrangements for pipe connections ,excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials.
a)with 250mm thk.dry brick work and 250 mm thk. cement brick work (6:1) and 1.00 m inside dia. For-SAIL/TATA/RINL 1 each 13905
86 Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C.........
(ii) For 20 users
(A) With Pakur Variety (SAIL/TATA/RINL) 1 Each 42244
87 Cement concrete with graded stone balast ( 40mm size excluding shuttering ) in ground floor (A) Pakur variety (a) 1:3:6 Poportion 1 Cu. M 4105.5
88 06 Kg with ISI marked Mono Ammonium Phosphate base ABC power conforming to IS:14609 and pressurized with nitrogengas.Suitable for operating between (-)30ºC to(+)55ºC. Fire rating -2A & 21B. A level should be pasted on the body of the Extinguisher duly signed & stamped by the Agency stating 1. Date of Installation 2. Date of Expiry/ Date of next refilling.( warranty card need to be submitted )[UDMA-2018,Schedule of Rates for Electrical-Mechanical Works Volumn-I,Item sl.No77(D),Page-24] 4 each 3721
AMBULANT DISABLED TOILET
89 Supplying, fitting & Fixing EWC (Size- 710x370x810 mm)in white glazed vitreous chinaware of approved make supplying, fitting and fixing in position complete with necessary nut and bolts. (Model Code No. S10221114-P Trap (CRUSE SET) of CERA or equivalent.) P-84 ; I-28 A 1 EACH 5446
90 Supplying, fitting and fixing 10 litre white glazed vitreous chinaware of approve low-down cistern of approved make with either side or bottom inlet, side overflow, brackets complete with all internal fittings. (Model Code No. S1060106 of CERA or equivalent.) P-84 ; I-28 B (a) 1 EACH 2406
91 Soft Close seat cover of approved make with lid and C.P. hinges, rubber buffer and brass screws suppling, fitting and fixing complete. E W C (Model Code No. B1520118 of CERA or equivalent.) White P-84 ; I-28 B (b) 1 EACH 1299
92 Supplying, fitting and fixing Stainless steel Wall Mounted Grab Bar. Load bearing capacity 150 kg, covered by Nylon surface with contour finish (for better grip) with Anti-bacterial surface complete. (Model Code No. B2210106 of CERA or equivalent.) 600mm Long P-84 ; I-28 B (c) 2 EACH 1825
93 Supplying, fitting and fixing Stainless steel Wall Mounted Hinged hand rail (750X100 mm) covered by Nylon surface with contour finish (for bettr grip) with two brackets.(Model Code No.B2210108 of CERA or equivalent.) 750 mm long P-84 ; I-28 B (d) 1 EACH 6760
94 Supplying, fitting and fixing 15 mm Twin Flush Fitting (Model Code No. B1810112 of CERA or equivalent). P-84 ; I-28 B (e) 1 EACH 1041
94 Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works.
(a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge.
i) In foundation & ground floor 0.999 Sqm 328
95 Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer's specification. In Ground floor:
(iii) Two coats. 34.25 Sqm 49
(ii) 25 mm. thick
96 Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials.
97 (a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs .
ii) Grill weighing above 16 Kg./sq.mtr and above (I) For hanging and locking arrangements including supply of materials and labour complete.
(15% extra over the corresponding item of grill ) 1.73 Qutl. 11150.4
98 Supplying and stacking of good earth (adequate for horticulture work) at site including royalty (earth measured in stack will be reduced by 20% for payment) 6 Cum 306
99 Supplying and stacking sludge (adequate for Horticulture work) at site in dry cake form from approved disposal work site including royalty, all lead and lift etc. (Sludge measured in stack will be reduced by 8%) 3 Cum 457
100 Spreading of sludge, dump manure,/farm yard manure/animel dung manure and good earth in required thickness. This includes supply of labour, tools & plants excluding materials. 20 % Sqm 1.75
101 Supplying and fixing grasses tiles of grass Maxican Carpet/Selection No. 1 Healthy & fresh grasses (size 1'x1' or bigger) including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from wees and fit for mowing including supplying good earth as required by Engineer-in-charge. (Rate includes supply of labour, tools & plants including materials) 20 % Sqm 201.42
102 Supplying and Planting of different plant / trees (Supplying well grown plants bushy and healthy, minimum height as specified i.e. exposed height including all leads & lift, carriage, handling, manuring, applying presticide and fertilizer etc. xxvii) Areca Palm 4 - 5 suckers of height 120 cm to 135 cm in earthen pots of size 25 cm. 10 Each 163
iv) Rangon hi-breed healthy plant. 10 Each 23
xvii) Bougainvillea (mix variety) of height 30cm-90cm in polybag of size 10cm-15cm. 10 Each 39
103 Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. i) With Pakur variety. (SAIL/TATA/RINL) 1 Each 6168
(b) Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring. . 3.85 Cum 192.38
104 Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works.
(a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge.
i) In foundation & ground floor 0.39 Sqm 328
105 Boring/drilling bore well of required dia for casing/strainer pipe, by suitable method prescribed in IS: 2800 (part 1), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. Boring/drilling bore well of required dia for casing/strainer pipe, by suitable method prescribed in IS: 2800 (part 1), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. 23.1.1 All type of soils. 23.1.1.3 400 mm Dia 70 Mtr. 839.66
23.1.2 For Rocky Strata including Boulders 23.1.2.3 400 mm Dia 10 Mtr. 1806.31
106 Supplying, fitting and fixing heavy type bell mouth reducing socket. (iv) 100 mm X 200 mm 2 Each 865
107 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well Casing (CM) pipe of required dia, conforming to IS 12818, including required hire and labour charges, fittings & accessories etc.. all complete, for all depths,, as per direction of Engineer-in-charge. 23.3.1. 100 mm nominal size dia 62 Mtr. 569.75
108 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 23.4.3. 200 mm nominal size dia 18 Mtr. 19155
109 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineerin- in charge.
110 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
111 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer –in-charge.
112 Packing the annular space between the outside of the tube well pipes & strainers and the bore with pea size washed gravel of approved quality having size from 2 mm to 5 mm or the size approved by the Engineer-incharge including cost of all materials labour and equipment complete.
113 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia
114 Supplying, fitting and fixing in position R.C.C. Manhole/ pit cover of approved make with rim of approved make (Heavy type) (ii) 560 mm dia.
115 R.C. shelves (1:1.5:3) either precast or cast in situ with stone chips and necessary reinforcement upto 1% (0.8% main and 0.2% distribution bars), shuttering etc. and 10 mm. thick cement plaster (1:4) including neat cement finishing and cutting chase fitting and fixing in position, mending good damages as necessary complete. In ground floor (a) 50 mm. Thick panels I. SAIL/ TATA/RINL 0.72 Sqm 1062
116 Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete.
(ii) 110 mm. Dia. (To collect Rain Water to a single pipe) 20 Mtr. 251
(ii) 110 mm. Dia. 4 No. 172
c) Bend 87.5 degree
(ii) 110 mm. Dia. 4 No. 160
(ii) 110 mm. Dia. 4 No. 111
117 Supplying, fitting and fixing PVC pipes for underground work of approved make of Schedule 80 (medium duty) conforming to ASTMD -1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted including cost of all materials ,jointing materials, cutting pipes, making threads ,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.) PVC Pipes (Dia)
80 mm 5 Mtr 795
118 Renewing gully grating. (i) 375 mm X 300 mm X 40 mm X 18 kg (Rate multiply by 100/105 for new work) 1 Each 1450.48
119 Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (A) (i) Single Socketed 3 Meter Length (b) 110 mm (Vent pipe) 10 Each 292
xv) Vent Cowl (b) 110 mm 1 Each 33
120 Providing weep holes in Brick masonry / Plain / Reinforced concrete abutment, wing wall / return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V:20H towards drawing face. Complete as per drawing and Technical specifications.
121 Supplying and laying true to line and level Tactile Finish Scratch resistant, Neutral to UV rays, Non-fade, High Slip Resistant Full Body Vitrified Tiles conforming to IS:15622-2006 & IS :4457- 2007 and tested in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance: 0.6, Mohr's hardness > 7.0, Staining resistance: Class-1, Water Absorption E < 0.5%], MOR > 38N/sq.mm & Breaking strength > 4000 N for Outdoor area of building e. g. Driveway, Pathway, Pavements, Parking lots, Sloping ramps, Entrance lobbies, Patios, Portico, swimming pool enclosure, Bus Passenger Shed & directing visually impaired persons, set over necessary underlay and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles and removal of wax coating of top surface of tiles with warm water and cleaning the tiles using soft and dry cloth complete including the cost of materials, labour and all other incidental charges complete including backside slurry but excluding the cost of underlay and true to the manufacturer's specification and direction of Engineer-in-Charge. In Ground Floor: Sizes-300 mm x 300 mm x15 mm 5.4 sqm 1768
In First Floor: Sizes-300 mm x 300 mm x15 mm 4.75 sqm 1780
122 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc. 0.999 Kg 21352
123 Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore.
(d) For depth upto 150 metre for 50 mm dia. tube well with top enlargement of 100 mm dia.
(i) 50 mm dia. boring etc. 160 Metre 287
(ii) 100 mm dia. boring etc. top enlargement 40 Metre 426
124 Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I).
(i) 50 mm 150 Metre 282
(ii) 100 mm 40 Metre 874
125 Supplying high density polythene strainer of approved make with adapter conforming to I.S. specifications.
(iv) 50 mm dia. 10 Metre 532
126 Packing the annular space between the outside of the tube well pipes & strainers and the bore with pea size washed gravel of approved quality having size from 2 mm to 5 mm or the size approved by the Engineer-in-charge including cost of all materials labour and equipment complete. 0.280 Cu.m 2029
127 Packing annular space between the outside of the housing pipe and the bore with puddled clay balls of approved size as per direction of the Engineer-in-charge with cost of all materials and labour complete. 0.320 Cu.m 417
128 Supplying, fitting and fixing steel cutter piece upto 450 mm long with sockets.
(iii) 75 mm dia. 1 Each 403
129 Supplying, fitting and fixing plug of approved make conforming to I.S. specifications.
(ii) 50 mm dia. 1 Each 71
130 Supplying, fitting and fixing heavy type bell mouth reducing socket.
(i) 50 mm X 100 mm 1 Each 455
131 Supplying, fitting and fixing G.I. cap at top
(i) 100 mm 1 Each 139
132 Washing and developing tube well with air compressor pump and engine for 8 (eight) hours continuous pumping per day with necessary arrangements for testing the yield in gallons per hour with 'V' notch including hire and labour charges for all tools and plants and scaffolding as required. 3 Days 7538
133 Labour for making arrangement for showing verticality test including the cost for hire charges of tools and plants, scafolding, labour etc. all complete 1 L.S. 916
134 Collecting sample of water for bacteriological and chemical test from any depth at any time during execution of work including hire and labour charges for tools and plants and sterilising the equipments, paying all charges and fees, testing etc. complete in all respect as per direction. 1 L.S. 1231
135 Supplying, fitting and fixing 300 mm M.S. housing clamp of approved quality. 2 Per Set 2235
136 Geophysical investigation of the acquifer by electrologging system with all tools and plants as necessary including supply of necessary report. 1 Each Test 8247
137 Supplying, fitting and fixing G.I. pipes of TATA make with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately)
(iv) 32 mm dia. medium quality 25 Metre 354
138 Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only). (vi) 32 mm dia 2 No. 1160
139 Supplying, fitting and fixing PVC pipes of approved make of Schedule 80(medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew,reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc.complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately
(b) For Exposed Work
32mm 40 Metre 236
140 Supplying, fitting and fixing chech valve (vertical) G.M. tested to 21 kg per sq. cm.
(vi) 50 mm 1 Each 1447
141 Supply and delivery of clear water vertical wet type submersible pump suitable for bore well conforming to IS: 8034 (and as amended thereafter) with standard MOC for potable clear cold water and BEE 3 Star Rated capable of discharging noted M³/hr against head of water column. The pump shall be directly coupled with a continuous rated 2- pole suitable wet type vertical squirrel cage induction motor conforming to IS: 9283 (and as amended thereafter), suitable for operation in AC Single phases 220 V, 50HZ (category B motor) as per specification and direction of EIC. 1 Ph. 230V, 1.5 HP submersible pump Make - Crompton Greaves/CRI/Siemens 1 Each 24623
142 Supply and delivery of direct on line (DOL) strater panel board conforming to IS13947 and IEC 947 of suitable HP rating for operation in 230V (±10%) AC, single phase, 50HZ(±5%) comprising of ammeter, voltmeter, thermal overload relay, 2 pole magnetic contactor, under voltage protection, indicating lamp, capacitors, on/off push buttons including 5 way connector, wiring with 1/1.5 sq. mm PVC insulated copper wire, powder coated vermin proof box of following capacities:- as per satisfaction and direction of EIC. 1 Each 4850
i) 1.5HP(Relay Range 9-14 Amp.)
143 Lowering, Installation and Commisioning of submersible pump motor set to the existing bore well after taking delivery of the pump as directed with necessary electrical works, fittings etc. Excluding the cost of pump, cable and starter but including cost of carriage, labour, tools and plants, taxes as applicable as per satisfaction and direction of EIC. 1 L.S. 6500
i) 1 Ph. 230V, 1.5 HP submersible motor set Make - Crompton Greaves/CRI/Siemens
144 Supplying and delivery and fixing of 2.5 sq. mm. 3 core flat PVC cable (Finolex or equivalent) for submersible pump motor set. 35 Metre 86.45
145 Supplying and Fixing GI water proof looping cable box having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below,Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same in pole muffing (a) 200 x 150 x 100mm 1 522.9
SUB-HEAD I: INTERNAL WIRING
All wiring Item including provision of conduit, conduit accsories , circuit wiring, switch, inspection box and all fitting completed as required.
1 SUB-HEAD I :- INTERNAL WIRING
1.01 Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Anchor make) fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish
2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC
Average run 8 mtr Point 70
1.02 Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to light point with 2 no. 2 way piano key type switch fixed on sheet steel fabricated switch board with Perspex/bakelite top cover on wall incl. necy. connections and making earthing attachment and mending good damages to building works [PVC casingcapping on surface and Switch board concealed]
Average run 9 mtr Point 2 2157
1.03 Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required
2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC [Separate 20A & CPU Board] RM 150
2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC [6+20A Power Board] RM 87.99
2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC [Sub main wiring and UPS] RM 155 22622
1.04 Supplying and fixing polythene pipe complete with fittings as necy.. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of MS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire (synchronizing with roof/beam casting work of building construction).
19mm dia 3mm thick Polythene Pipe RM 120 4536
25mm dia 3mm thick Polythene Pipe RM 127
1.05 Cutting channel of 40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works
19 mm dia 3 mm thick polythene pipe without earth continuity wire RM 80 7308
1.06 Cutting channel of 43 mm x 43 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works
25 mm dia 3 mm thick polythene pipe without earth continuity wire RM 90 10490
1.07 Supplying and fixing PVC casing-capping [Precision Make] on wall or ceiling, incl. necy.. PVC fittings etc. and mending good damages to building works
20x10mm Size RM 20
25x10mm Size RM 20
1.08 Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
2.5 sqmm Set 35 221
4 sqmm Set 38 279
6 sqmm Set 31 293
1.09 Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point incl. S&F 240 V 5A 3 pin flush type plug socket & piano key type switch (Anchor make) incl. S&F earth continuity wire, fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish
2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC
On Board Point 19
Average run 6 mtr Point 17 14923
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required [Separate 20A Switch Board] Each 6 1808
Supply & Fixing 240 V, 4 nos. 6A, plug socket with separate 4 nos. 6 A Piano key type switch, indicator & 16A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required [CPU Board] Each 4
Supply & Fixing 240 V, 2 nos. 6A, & 2 nos. 20A plug socket with separate 2 nos. 6 A & 2 nos. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required [Power Point] Each 3
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket with 20/25A Modular switch (Brand approved by EIC) type SP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [UPS Board:2, Autocav Board:1] Each 3
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections. [UPS Board] Each 2 271
2 SUB HEAD II:-DISTRIBUTION BOARDS/BUSBAR/MAIN SWITCH
MAIN SWITCH, BUSBAR AND D.B
Supply, Delivery, Installation, Testing and Commissioning of Indoor cubicle type LT distribution panel board along with Continuous Neutral & Earthing Indication of required size, wall/stand mounted compertmentalized with maple arrangement having rigid and self supporting structure with cable alley fabricated from 2 mm thick CRCA sheet steel and M.S. angle frame for panel mounting support and making necessary grouting arrangements with neat cementing finish as per direction of EIC. Unit 1
2.02 Supplying and fixing Sheet steel Main Switches on angle iron frame on wall
32A DP [Standard/HPL/Havells Make] Each 1 1341
Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – ( As per Drawing no. 470 of PWD Specification Book – May 1991)
2 bars 240 V, 63 A Mtr. 1 1766
2.04 Supplying and fixing Changeover switch with Sheet Steel enclosure on flat iron frame on wall with nuts bolts etc
32A,240V DP, Make - Standard/HPL/Havells Each 1
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. [Make - Legrand/Havells/L&T/Siemens]
2+4 way [EDB 1] (607710) Each 1
2+8 way [Ground & 1st Floor, NDB 2 & 3] (607711) Each 2 3102
2+12 way [Ground & 1st Floor, EDB 2 & 3] (607712) Each 2 3690
2.06 Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment
2 Way [Autoclav Point] Each 2
4 Way [NDB 1] Each 1
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Legrand/Havells/L&T/Siemens).
Single pole 6-32A MCB [SPNDB Outgoing] Each 40
Single pole 25A MCB [EDB1 Outgoing] Each 2
Double pole 32A MCB [EDB1,NDB 2,3] Each 3 1720
Double pole 32A MCB [UPS] Each 2 1147
Double pole 25A MCB [EDB 2,3 Incomer] Each 2 1147
Double pole 32A MCB [NDB 1-4Way, Autoclav Point] Each 4 2293
3 SUB-HEAD III :- SUPPLY & FIXING OF FANS
3.01 Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc. Each 13
3.02 Supplying & Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S&F 12mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concrete from entering the box. Each 13 2375
3.03 Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessaryconnection as required by 2x1.5 sqmm flexible copper wire. Each 13
3.04 Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter:
30 cm (12") Each 5
3.05 Supply & Fixing louver shutter on wall with necy.. bolts & nuts (6 mm dia x 62 mm long)
30 cm Exhaust fan (12") Each 5
3.06 Supplying & Fixing 240 V AC Buzzer (Ancho) on HW board incl. S&F HW board Each 2 260
3.07 Supply & delivery of Sweep:- 48" (1200mm) AC ceiling fan, 50-70 Watts, Speed:->=350 RPM, Air delivery:->=220 CMM, make: (Orient PSPO NEWBREEZE or SUMMERCOOL / equivalent of EPC or USHA STRIKER PLUS or CROMPTON [Approved by EIC] Each 13 30929
3.08 Supply & delivery of heavy duty Exhaust Fan of Sweep:-12" (300mm), 240 volt, 50 Hz, AC , 50-60 Watts, Speed >900 RPM, Air delivery >=1145 CMM suitable for . [Make - Orient (Model:Power Flow) /EPC/Havells/Crompton Greaves] [Approved by EIC] Each 5 9065
4 SUBHEAD IV:-SUPPLY AND LAYING OF CABLE
4.01 Supplying of 1.1 KV. Grade LT power cable, XLPE insulated, cores laid up, PVC inner sheathed aluminium armoured conductor of the following specificaion:- (make: Polycab/Gloster/Havells) 16 sqmm 2 core (A2XWY/A2XFY) RM 20 4062
Laying on Wall / surface with Saddles / clamps
Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting RM 20
CABLE TERMINATION
4.03 Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
For 2 core upto 16 sqmm Each 4
4.04 Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
2 core 16 sqmm cable Each 4 244
5 SUB-HEAD V :- EARTHING:
Soil Excavation :
5.01 Excavation of soil for installation of Earth Electrode and filling & ramming.
For Morrum Soil Cu mtr. 10
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:
By TATA-Medium GI pipe [Mains Earthing:2, UPS Body:1, UPS Neutral:1] Set 4
5.03 Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe Item 4
5.04 Extra for treatment of soil by using salt & charcoal or coke for plate electrode Set 4 2230
5.05 Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. mtr. 5 819
Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. mtr. 30 2898
5.07 Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages
No. 6 SWG mtr. 51.1
6 SUB-HEAD VI :- TELEPHONE & DATA POINTS
NETWORKING & TELEPHONE SOCKET
6.01 Supply & Fixing RJ45 sitable for CAT6 cable (Brand approved by EIC) with PVC board and top cover plate on wall and making necessary connections & testing as required Each 4 827
6.02 Supply & Fixing Telephone socket (RJ11) Modular type (Brand approved by EIC) with PVC board and top cover plate on wall and making necessary connections & testing as required. Each 6
6.03 Supplying & Drawing 2-pair Telephone cables with high density polyethylene insulated solid annealed high conductivity bare copper of dia 0.5mm in prelaid PVC rigid conduit / in polythene pipe embeded in wall. RM 72
6.04 Supplying & Drawing LAN cable (CAT6) (Brand approved by EIC) in prelaid PVC rigid conduit/ in polythene pipe embeded in wall. RM 60 1764
6.05 Supplying and fixing PVC casing-capping [Precision Make] on wall or ceiling, incl. necy. PVC fittings etc. and mending good damages to building works
20x10mm Size RM 132
7.01 Supply & delivery of single 4ft Batten type LED tube light fitting, 1200 mm, Efficacy>= 100 lm/W, THD<10%, complete with all accessories. (Havells: LED Pride Plus NXT Batten 22 W 6500 K) or equivalent of Philips, Crompton etc. [Approved by EIC] Each 26 4277
7.02 Supplying & Fixing Out door type CFL/LED luminaire (Havells make-LHRC4185099 or equivalent) with deep drawn aluminium housing anodised inside & clear acrylic cover and accessories incl. for 85 watts CFL lamp / 20 watt LED incl. S&F 32mm dia GI pipe bracket, clamp, nut & bolts etc. Each 2
7.03 Supply & Delivery at site 9 watt LED Bulb, Efficacy>=90 lm/W, Base Cap:-B22 [Make-Havells, LED DEKOR BULB 9 W B22 CDL] or equivalent of Crompton, Philips etc. [Approved by EIC] Each 23 1979
7.04 Fixing only single /twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener Each 26
7.05 Fixing only lamp Each 20
Solar PV Module
1 Supply & delivery of 550 Wp or above Mono-PERC/N-Type TOPCON, 144 Half-Cell Monofacial/Bifacial Module with Min. Module Efficiency 21.3%, IEC & BIS Certified (Manufactured in India) with Annual Degradation Not More Than 0.60%. [Manufacturer's Authorization is mandatory].
[Make:- RenewSys/Panasonic/Waaree] [Approved by EIC] 2 Item 8430.4
2 Supply & delivery of Single Phase Off-Grid Inverter with Inbuilt MPPT Charge Controller Size: 2 KVA/24 Vdc. [Manufacturer's Authorization is mandatory].
[Make:- Luminous/Flin Energy/Deye] [Approved by EIC] 1 Item #,##0.000 16867
3 Supply & delivery of Module Mounting Structure of HDGI (86 Micron) with Initial Height of 500mm from Roof Level, Withstand Wind Speed of 150 Km/Hr. (Min 56 kg/kW) with All SS304 Fasteners 1 Set 6227
Lead Acid Battery (ESS)
4 Supply & delivery of Solar VRLA Gel Maintenance Free 12V-100Ah Battery @50% DOD with Battery Cable & Accessories (5 Years Warranty)
[Make:- Exide/Luminous/Amara Raja] [Approved by EIC] 4 Item 14465.8
5 Supply & delivery of DC Solar Cable 1C x 6 Sqmm 1.5 kV Grade XLPO Insulated Tinned Copper (UV Outdoor Cable)
[Make:- Polycab/APAR/LAPP] [Approved by EIC] 80 Mtr. _ * #,##0.999_ ;_ * \-#,##0.999_ ;_ * "-"??_ ;_ @_ 4474
6 Supply & delivery of Earthing Cables 1C x 25 Sqmm 1.1 kV Grade PVC Insulated Flexible Copper G/Y
[Make:- Polycab/Mescab/KEI] [Approved by EIC] 29 Mtr. 248.05
LT Distribution, Battery Cable & MCB DB
7 Wiring in 1.1 KV grade single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc. [PWD SOR 2017, Page No.E-11, Item No.1]
8 Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. [PWD SOR 2017, Page No.D-10, Item No.13]
2+4 way [Enclosure (DHDPSNODRW04)] [Solar Main AC DB] 1 Item 935
2+6 way [Enclosure (DHDPSNODRW06)] [Solar AC DB-Gr. & 1st Fl.] 2 Item 1073
[Make:- Havells/Legrand/BCH] [Approved by EIC]
9 Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. [PWD SOR 2017, Page No.D-5-6, Item No.6]
32A DP Isolator [For Solar Main AC DB]
[Make:- Havells/Legrand/BCH] [Approved by EIC] 2 Item 208
10 Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection [PWD SOR 2017, Page No.D-6, Item No.7]
6-32A SP MCB [Solar AC DB-Gr. & 1st Fl.]
[Make:- Havells/Legrand/BCH] [Approved by EIC] 12 Item 168
11 Supplying and fixing Changeover switch with Sheet Steel enclosure on flat iron frame on wall with nuts bolts etc [PWD SOR 2017, Page No.D-1, Item No.2]
(a). 32A 240V DP Changeover Switch
[Make:- Standard/L&T/BCH] [Approved by EIC] 1 Item 1315
12 Supplying & Fixing CRC sheet metal (16 SWG) JB-cum- Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. bakelite/Perspex/coloured Perspex (wall matching colour) top cover 3 mm thick flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works [PWD SOR 2017, Page No.E-3, Item No.10]
(a). 150 mm x 100 mm x 65 mm 6 each 208
13 Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works [PWD SOR 2017, Page No.E-4, Item No.11]
(b). 100 mm x 100 mm x 65 mm 8 each 143
14 Supply & Fixing bakelite / perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required [PWD SOR 2017, Page No.E-4, Item No.12]
(a) 100 mm x 100 mm x 65 mm 8 each 35
(b). 150 mm x 100 mm x 65 mm 6 each 42
15 Supply & Fixing 240 V 6 A Piano key type switch (Brand approved by EIC) on existing sheet metal switch board having bakelite/perspex top cover by screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required [PWD SOR 2017, Page No.E-5, Item No.14(a).] 30 each 27
16 Supply & Fixing 240 V, 6A plug socket (Brand approved by EIC), without switch & plug top, on existing sheet metal switch board with bakelite/perspex top cover by screws after making housing for plug by cutting bakelite/perspex top cover and making necy. connections with PVC wire and earth continuity wire etc. [PWD SOR 2017, Page No.E-5, Item No.15(a).] 5 each 36
17 Supply & Delivery of 24V DC Battery Cable Set with MCB Configuration
[Make:- Polycab/Mescab/KEI] [Approved by EIC] 1 Set _ * #,##0.000_ ;_ * \-#,##0.000_ ;_ * "-"??_ ;_ @_ 1082
AC-DC Distribution Box
18 Supply & Delivery of AC-DC Integrated Distribution Box with Over Current (PV Fuse 1000V 15A) & Surge Protection (DC & AC SPD Type 2)
[Make:- Fender Energy/Earth Energy Solutions] [Approved by EIC] 1 Set 8430.4
Earthing & Lightning Protection Work
19 Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:- [PWD SOR 2017, Page No.G-1, Item No.2]
(a). By TATA-Medium GI pipe [AC DB Earthing] 1 Set 1524
20 Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe [AC DB Earthing] [PWD SOR 2017, Page No.G-2, Item No.3(a).] 1 Item 915
21 Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required [AC DB Earthing] [PWD SOR 2017, Page No.G-2, Item No.4(a).] 0.9 Mtr. 156
22 Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. [PWD SOR 2017, Page No.G-3, Item No.5(c).] 16 Mtr. 92
23 Supply and Delivery of 1 x Copper Air Terminal with Mast, 2 x 2m x 17.2mm Copper Bonded Earth Electrode, 2 x Backfill Compound, 2R x 16Sqmm Flexible Copper Earthing Cable, 2 x CI/FRP Pit Chamber Cover Pit at DC Side: 2 Nos. 2 Item 5939.6
24 Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, on 1st floor as per relevant IS codes [PWD Civil SOR, V.P. No. 26, Item No.10 (3rd Corri. P-12, It.33)]
(a). M-20 grade with Pakur variety [for fixing of mounting structure on roof slab] 0.054 m3 _ * #,##0.799_ ;_ * \-#,##0.799_ ;_ * "-"??_ ;_ @_ 342
Fire Extinguisher
25 Supply, Delivery and installation of ABC Powder type fire extinguishers (stored pressure) HSN code-84241000 conforming to IS:15683 and complete in all respect as per direction of EIC [UD&MA SOR M&E Works 2018, Page No.23, Item No.77]
(C) 04 Kg with ISI marked Mono Ammonium Phosphate base ABC power conforming to IS:14609 and pressurized with nitrogen gas. Suitable for operating between (-)30ºC to (+)55ºC. Fire rating -1A & 13B 1 Set 3157
26 Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works [PWD SOR 2017, Page No.E-16, Item No.7]
(b). 25mm size 40 RM 69
27 Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. [PWD SOR 2017, Page No.D-14, Item No.34(a).]
(i). With out angle iron support [150x50x1.25mm (18SWG)] 20 Each 211
28 Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. [PWD SOR 2017, Page No.F-5, Item No.9]
(i). 2.5sqmm 30.9 Set 6
(ii). 4 sqmm 18 Set 7
(iii). 6 sqmm 11 Set 9
29 Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : [PWD SOR 2017, Page No.F-4, Item No.7]
(a). For 2 core:- upto 2.5/4 sqmm 4 Each 63
For 1 core:- upto 6 sqmm 4 Each 68
upto 25 sqmm 4 Each 132
30 Supply & Delivery of MC4 Connectors, PVC/M.S. Saddles, Bullets, Screws, Fasteners, Ferrule, Cable Tie, Spare Tools, Caution Board, Safety Signage and other Electrical Accessories as required for setting up of solar power plant 1 Lot 2500
SITC & Comprehensive Maintenance of Solar PV Power Plant
31 Design, Engineering, Installation, Testing, Commissioning & Additional 1 Year of Comprehensive Maintenance Work for Off-grid Rooftop Solar PV Power Plant (1.1 kWp) at Su-Swasthya Kendra (Type-A) @5% of Total estimated cost of Non-scheduled items:- Rs.1,60,633.00 1.1 kWp 8031.65
1 Supply, installation, and commissioning of a microprocessor/microcontroller-based, networkable, intelligent, analogue addressable single-loop control panel, expandable up to 4 loops. The control panel is designed with ARM Cortex-M4 32-bit Microcontroller with high resolution (480 X 272 pixels) 4.3 inch graphics TFT LCD display with symbolic representation for power status, displays color-coded events (like Red, yellow & Amber ).The system status and control keys with symbolic representation for easy access.The control panel has inbuilt multilingual features (English and Bengali).The panel status shall be visualized on LCD/LED in unambiquese color. The system should support for the 140 Nodes maximum in a Network including Repeater panels & NAC Extender Power supply panels. The total Network Distance shall cover upto 16 Kms for peer to peer network and 1.2 Kms for Repeater & NAC Extender power supply panel network. This panel can operate as a standalone or connect up to 16 panels in a network via Network Interface Card (NIC) for peer to peer networking, Inbuilt USB 2.0 Port for upload and download the panel configuration using the Configuration tool, 1 Item 27320
Two inbuilt programmable inputs, Two inbuilt programmable NAC's with short circuit protection, Programmable 24VDC (Steady/Reset) and Two Programmable Relays, One dedicated Fault Relay, 10000 events log with RTC, Numaric keypad for menu access. The panel should be equipped with sufficient numbers of loop with 20% spare capacity with each loop shall have a capacity of 250 intelligent analog addressable devices in one loop in any combinations including loop powered sounder,sounder-strobe etc. the system has high reliability with the capacity to support 16,000 devices in any combination. The central processing unit shall contain and execute all
control-by-event (including Boolean functions including but not limited to AND,OR,ANYx and CROSSZONE) programs for specific action to be taken if an alarm condition is detected by the system. The panel shall have a built in power supply and operate 110 / 230VAC + 10% – 15%, 60 / 50 Hz, 450W,The panel shall have its own battery backup of a minium 24 hours in normal run and 5 minitues in the alarm condition. The battery shall be of 24V DC and of sealed maintenance free type, housed inside the panel up to 26Ah, the charger support up to 65AH.The panel construction 18 Gauge CRCA sheet with powder-coated finish, builtin RS485 output avaiable for Networking repeater and NAC extender/Power supply panels. Optional: for BMS integration thru BACnet/MODBUS converter, Graphical Software,TCP/IP Module, IOT module, provision for GSM based Auto dialler, Approval UL 864 -10th Edition or FM.
[Make:-Aaral/ Simplex/Ravel/Notifier] [Approved by EIC]
[Including 5 Years Comprehensive Warranty]
Addressable Multi Sensor
2 Supply ,Installation and Commissioning of analog Addressable Multi Sensor - Heat Cum Smoke detector with ROR featues to raise an alarm when the temperature reaches 11.1°per Minute with base, Binary coded address setting DIP switch. Dual LED’s for 360° visibility. Polarity free, Sleek low-profile housing design. Regular 100mm base. IP Rating : IP - 42. Approval: UL or FM. 13 Item 1222
[Make:-Aaral/ Simplex/Ravel/Notifier] [Approved by EIC]
Addressable Manual Pull Station
3 Supply, Installation and Commissioning of analog Addressable Manual Pull Station - Double Action with inbuilt fault isolator, shall be resettable by Key lock access to avoid unauthenticated restorations,FR - ABS Housing, monitoring the field NO/NC devices. Shall have Binary Coding Setting Dip Switch, The MCP shall have operating temperature range from 0°C to 49°C and humidity tolerance range up to 93% RH, Non-Condensing. Complete with termination and testing as per requirement and as per specification. 2 Item 1544
[Make:-Aaral/ Simplex/Ravel/Notifier] [Approved by EIC]
4 Supply, Installation and Commissioning of Manual Pull station back box (Single Gang Box) compatiable with manual pull station single/dual action equipped with blinking LED for normal condition and steady LED for manual pull station activated condition along with 8 way dip switches for addressing the devices. 2 Item 305
[Make:-Aaral/ Simplex/Ravel/Notifier] [Approved by EIC]
5 Supply, Installation and Commissioning of wall mount loop powered sounder - Strobe with builtin isolator fixing box having minimum sound pressure level of 85dBA @3mtr, Flash intensity should be 15cd minimum Candela Low and High can be selected from FACP,flasher frequency 1HZ per second, shall have 8 Different tone selection from FACP ,Adjustable volume control,Sounder and strobe OFF facility.It shall be RED in colour. Complete with termination and testing as per requirement and as per specification,Material -FR ABS Plastic,Temperature range 0-49deg C , Shall have Binary Coding Setting Dip Switch,Dimensions (100.5 D x 72.25H)mm. Cable wiring for the termination should be at base of sounder and head shall be installed seperately. IP Rating- IP60 2 Item 1859
[Make:-Aaral/ Simplex/Ravel/Notifier] [Approved by EIC]
6 Supply ,Installation and Commissioning of armoured 2 C X 1.5 Sq mm FRLS Twisted Pair Tinted copper multistranded cable (Red Color) for Fire Alarm System. Complete with termination and testing as per requirement and as per specification. 122.67 RM 60
[Make:-Finolex/ Plaza/Polycab/ RR Cable] [Approved by EIC]
NOTE: 1. The Fire Alarm system shall comply with latest requirements of -- 1. National Fire Protection Association (NFPA) Standards. 2. IS 2189 3. NFPA 70 National Electric Code 4. NFPA 72 National Fire Alarm Code 5. local Statutory Regulations 6. Manufacturer Recommendation.
TESTS: 1. The system shall be tested and commissioned by a qualified competent, trained engineer or technician authorized by the manufacturer of the fire alarm equipment to technically supervise and participate during all of the adjustments and tests for the system under active monitoring of OEM. 2. Before energizing the cables and wires, check for correct connections and test for short circuits, ground faults, continuity, and insulation and other tests as per above standards must be done. Before taking up the work necessary building drawing/ floor plan with layout should be prepared and to be approved from the EIC / Engineering Officer under Tender Inviting Authority according to the prevailing fire safety policy.
The Agency must procure the materials from the Manufacturer/OEM or from their authorized sales channel so that the standard warranty/supprot of the Manufacturer/OEM becomes applicable to the products to be delivered and installed by them [Including 5 Years Comprehensive Warranty of Control Panel].
Documents that authenticates such procurement from the Manufacturer/OEM or from their authorized sales channel and standard warranty/support should be sent from the e-mail of the Manufacturer/OEM/authorized sales channel to the e- mail of Engineer-in-Charge and hard copy of it to be submitted during execution of work/submission of bill.
If any refurbished material is supplied and installed, penal action will be taken as per existing rules.
Defect Liability period 1 (One) Year
LT Distribution, MCB DB & Switch Board
7 Wiring in 1.1 KV grade single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc. [PWD SOR 2017, Page No.E-11, Item No.1]
8 Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment [PWD SOR 2017, Page No.D-9, Item No.11]
2 Way 1 Item 270
9 Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection [PWD SOR 2017, Page No.D-6, Item No.7]
10A SP MCB [For FDA Control Panel] 1 Item 168
[Make:- Havells/Legrand/BCH] [Approved by EIC]
10 Supplying & Fixing CRC sheet metal (16 SWG) JB-cum- Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. bakelite/Perspex/coloured Perspex (wall matching colour) top cover 3 mm thick flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works [PWD SOR 2017, Page No.E-3, Item No.10]
(d). 240 mm x 200 mm x 65 mm 1 each 318
11 Supply & Fixing bakelite / perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required [PWD SOR 2017, Page No.E-4, Item No.12]
(e) 240 mm x 200 mm x 65 mm 1 each 80
12 Supply & Fixing 240 V 6 A Piano key type switch (Brand approved by EIC) on existing sheet metal switch board having bakelite/perspex top cover by screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required [PWD SOR 2017, Page No.E-5, Item No.14(a).] 2 each 27
13 Supply & Fixing 240 V, 6A plug socket (Brand approved by EIC), without switch & plug top, on existing sheet metal switch board with bakelite/perspex top cover by screws after making housing for plug by cutting bakelite/perspex top cover and making necy. connections with PVC wire and earth continuity wire etc. [PWD SOR 2017, Page No.E-5, Item No.15(a).] 2 each 36
14 Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. [PWD SOR 2017, Page No.F-5, Item No.9]
(i). 1.5sqmm 20 Set 6
15 Supplying and Fixing of Junction boxes, Cable glands, Connector, Screws etc. fixing accessories for SITC of Detectors, MCP and modules. 1 Set 1200
16 Supply, fitting and fixing including all necessary arrangements for complete installation of Wall mounted Water Purifier having Storage Capacity- Not Less than 8L, RO+UF+TDS Control + UV In-Tank + Copper Water Purifier, Purification Production Rate- not less than 15 L/hr with 1 Year Warranty + 3 Years Extended Service Free (including all taxes, Market Rate) [Make- Kent/Aquaguard/LG/Equivalent] (2nos.) 2 No 20976.5
A. TOTAL AMOUNT:
B. Add GST 18% [B= A*0.18]
C. Total Amount with 18% GST [C=A+B]
D. Add L.C. @1% [D=C*0.01]
E. Sub Total Amount [E=C+D]
District Engineer Birbhum Zilla Parishad
Select, At Par, Excess (+), Less (-) IOCL Select Excess (+) Less (-) Excess (+) Less (-)
Tender Inviting Authority: Additional Executive Officer, Birbhum Zilla Parishad, Suri, Birbhum, 731101
Name of Work: Construction of Su-Swasthya Kendra (Health & Wellness Center) (HWC Type-A)" at Hatkalua within Labpur Block
Contract No: WBZP-BHM-N-92-04
Name of the Bidder/ Bidding Firm / Company :
Sl. No. Item Description Item Code / Make Quantity Units Estimated Rate in Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category
1.01 Construction of Su-Swasthya Kendra (Health & Wellness Center) (HWC Type-A)" at Hatkalua within Labpur Block BI01010001010000000000000515BI0100001113 Nos Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Please Enable Macros to View BoQ information
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.81 MB
Tendernotice_2.pdf
PDF • 0.54 MB
WBZP-BHM-BIF-v3.xls
Tender Documents • 0.05 MB
SOQ-04.xls
Tender Documents • 0.29 MB
BOQ_2492477.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .