Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.0 CrAccepted-AOC | ₹3.0 Cr | 1 | Accepted-AOC 1st Lowest |
| 2 | 2₹3.1 Cr+₹10.8 L (3.61%)Rejected-Finance | ₹3.1 Cr+₹10.8 L (3.61%) | 2 | Rejected-Finance 2nd Lowest |
| 3 | 3₹3.2 Cr+₹26.2 L (8.77%)Rejected-Finance MALLIKARJUN PRASANNA BUILDING NEAR BAJAJ SITARA MOTORS COLMBOROD NAVELIM GOA | NAVELIM | SOUTH GOA | GOA | ₹3.2 Cr+₹26.2 L (8.77%) | 3 | Rejected-Finance 3rd Lowest |
| 4 | 4₹3.3 Cr+₹28.8 L (9.67%)Rejected-Finance HOUSE NO 195 3 NAIKWADA CANCA BARDEZ GOA | ₹3.3 Cr+₹28.8 L (9.67%) | 4 | Rejected-Finance 4th Lowest |
Tender Value
₹3.3 Cr
EMD Value
₹6.6 L
Closing Date
30 Dec 2021, 3:00 pmClosed
Executive Engineer
4th floor Paryatan Bhavan Patto Panaji
Trekking Corridors nature Trails and Camping area in Hinterlands Young Goa at sixty Skill Building of Goan Youth Regd Development and Illumination of Parking and providing basic amenities near Collem Panchayat and Dudhsagar Fall Collem Goa
2021_GTDCL_2144_1
GTDC/PC/EE(S)/2021-22/e-29
Open Tender
Civil Works - Others
Item Rate
240 days
Panjim
Please refer Tender documents.
6 documents required · 6 mandatory
₹15,000
₹6.6 L
24 Jan 2022
16 Dec 2021
31 Dec 2021
16 Dec 2021
30 Dec 2021
16 Dec 2021
16 Dec 2021 - 24 Dec 2021
Amount
CIVIL WORKS
Clearing grass and removal of rubbish upto a distance of 50 m outside the periphery of the area
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : All kinds of soil
Earthwork in excavation in trenches for all leads & lifts in all type of strata comprising of any type of materials either in full or part as the case may be adopting any method/methods as may be convenient as permitted excluding blasting in all conditions such as dry, moist, foul, saturated, submerged, etc,. including dressing of sides, planking & strutting, timbering ,ramming of bottom ,pumping and bailing out water ,barricading danger lighting guarding, getting out excavated soil & stacking as directed by Engineer for all leads & lifts etc. complete
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer .
Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete.
Providing & laying cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded granitic or basaltic stone aggregate 20 mm. nominal size) excluding cost of centering, shuttering and finishing in: All work up to Plinth level
Centering & shuttering including Strutting, Propping & removal of forms for : Vertical surfaces such as retaing walls, return walls, Partitions, walls (any thickness) including attached Pilasters, Buttresses, Plinth and string courses, Fillets and the like
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) (Square Hollow Section (SHS) IS4923 /Rectangular Hollow Section (RHS) IS4923/ Circular Hollow Section (CHS) IS1161 closed Structural Steel of approved make (Min Yeild Stress 310 Mpa)) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Laterite masonry in neatly dressed stones for 20 cms thick masonry walls in cm. 1 : 4 (1 cement : 4 coarse sand) in foundation upto plinth level
Half brick masonry in cement mortar 1:3 (1cement : 3 coarse sand) with bricks of class designation 75 kg /cm2. Upto floor V level.
Providing water proofing treatment over the new R.C.C. roofs terrace toilet by spreading cement slurry over the R.C.C. slab and laying of 10cms. Average laterite stone ballast coba with the necessary gradient for easy flow of rain water and the coba in covered with damp proof of Hindustan water proofing co. Or equivalent jointless water proofing plaster of mix 1:3 ( 1 cement : 3 find sand), finished smooth with wooden trowel with false marking of 30 cms square. The vertical surface of the adjoining walls are to be treated upto a height of 30cms including rounding of junction (the rate includes for complete items including labour and materials and including cost of initial treatment of roof slab as follows. The injunction of damp proof or equivalent compound with cement solution will be given as and when found necessary for filling honey comb, cracks etc. in the R.C.C. slabs). NOTE: cement consumption 25 kg/sq.m.
Providing and and laying Ceramic glazed floor tiles 300 x 300 (thickness to be specified by the manufacturer) of 1st quality conforming to IS:15622 of approved make in colours such as white, ivory, grey, fume red, brown laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigment etc., complete
Providing and and laying antiskid floor tiles 12 x 12 upto 16 x 16 in of Johnson, Somany, Kajaria (thickness to be specified by the manufacturer) of 1st quality conforming to IS:15622 of approved make in shades as specified laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigment etc., complete Light Shades
Providing and fixing 1st quality ceramic glazed wall tiles (Johnson, Somany, Kajaria )conforming to IS:15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand ) and jointing with grey cement slurry @3.3kg per sq.m including pointing in white cement mixed with pigment of matching shade complete. Wall Ceramic Glazed Tiles : 300 x 600
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade, area of slab over 0.50 sqm Jet Black
Kotah stone slab flooring over 20 mm (average) thick base laid over & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) 20 mm thick.
Providing and laying factory made Shot blasted cement concrete interlocking paver block of minimum M35 grade made by heavy duty block making machine with strong vibratory compaction and of aprpoved size and design / shape laid in 50 mm thick compacted bed of coarse sand, filling the joints with coarse sand, etc. all complete as per the direction of Engineer.- in I, Wave, Rectangular, Square etc. shapes. The products should comply to IS 15658:2006 and manfucatured by ISO9001: 2008 certified plant. The shot blasting should be done using 0.4-0.5mm dia steel shots with a speed of 3200 rpm. 60 mm thick in all colours except grey
Providing and laying factory made Shot blasted cement concrete interlocking paver block of minimum M35 grade made by heavy duty block making machine with strong vibratory compaction and of aprpoved size and design / shape laid in 50 mm thick compacted bed of coarse sand, filling the joints with coarse sand, etc. all complete as per the direction of Engineer.- in I, Wave, Rectangular, Square etc. shapes. The products should comply to IS 15658:2006 and manfucatured by ISO9001: 2008 certified plant. The shot blasting should be done using 0.4-0.5mm dia steel shots with a speed of 3200 rpm. 60 mm thick in Grey colour
Providing and laying factory made Shot blasted cement concrete interlocking paver block of minimum M35 grade made by heavy duty block making machine with strong vibratory compaction and of aprpoved size and design / shape laid in 50 mm thick compacted bed of coarse sand, filling the joints with coarse sand, etc. all complete as per the direction of Engineer.- in I, Wave, Rectangular, Square etc. shapes. The products should comply to IS 15658:2006 and manfucatured by ISO9001: 2008 certified plant. The shot blasting should be done using 0.4-0.5mm dia steel shots with a speed of 3200 rpm. 80 mm thick in all colours except grey
Providing and laying factory made Shot blasted cement concrete interlocking paver block of minimum M35 grade made by heavy duty block making machine with strong vibratory compaction and of aprpoved size and design / shape laid in 50 mm thick compacted bed of coarse sand, filling the joints with coarse sand, etc. all complete as per the direction of Engineer.- in I, Wave, Rectangular, Square etc. shapes. The products should comply to IS 15658:2006 and manfucatured by ISO9001: 2008 certified plant. The shot blasting should be done using 0.4-0.5mm dia steel shots with a speed of 3200 rpm. 80 mm thick in grey colour
Providing and fixing in position S.S. hand rail in main stair case, and landing as per approved design shown in the drawing including bending handrail pipe to proper shape in curves with specials, etc. complete.
Supplying and fixing of Precast RCC slabs(factory made,the factory should be ISO certified and registered under Dirctorate of Industries, Govt. of India) at site in concrete Grade of M-25 with 20 mm nominal size Granitic or basaltic aggregate, consolidated by means of mechanical platform, vibration etc. with lifting hooks of M.s. 10mm bars and PVC cups including cost of reincforcement, Certificate from manufacturer shall be produced indicating grade of concret and minimum content of steel in the product along with 5 year free replacement warranty in case of breakage complete and as directed by Engineer -in -charge. Size 900 x 400 x 100 mm with steel reinforcement not less than 5.0 kgs per unit -12 T capacity
12 mm thick cement plaster 1:4 (1 cement:4 fine sand)
6mm thick cement plaster to ceiling with 1:3 (1 cement : 3 fine sand)
18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) and top layer 6mm thick with cement plaster 1: 3 (1 cement : 3 coarse sand) finished with sponge.
Extra for plastering done on moldings, cornices, or arch it raves including neat finish to line and level. In one coat
Forming & Finishing the 20 mm groove in plastered surface & repair the edges as per specifications and directions of the Engineer In Charge.
Providing and applying white cement based putty of average thickness 1.00mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Wall painting (two or more coats) with plastic emulsion paint of approved brand and manufacture on new work to give an even shade.
Painting three or more coats with acryllic exterior paint of approved brand and manufacture (such as weather shield,APEX) including applying one coat of cement primer and one coat of surface treatment etc. complete.
Providing ,fixing, testing and commissioning of premium container toilet blocks self sustaining toilet blocks powered by Solar Power with wash rooms etc of size 8 X 8ft . The said toilet container should be pre-fabricated with hoisted on structural framework made up of stainless steel (S.S.202grade)of minimum size 50mmx50mm x1.2mm thick of (18-SWG) for main frames i.e. beams and columns, for 50mmX25mm support frames amd 40mm x20mm and 20mm x20mm for door frames or as per the design requirements size not less than mentioned above.The major components of the said toilet block are as :The wall panels shall be of 30mm thick and should be insulated withPU rigid frame foam (poly Urethrene ) at minimum 40Kg/m cube density .Outer skin material shall be of Fiber composite material with Fire retardent rasin of 3mm thick and inner skin material should be laminated by Bakelitte SheetsFiber composite with fire retardent resin sheets 3mm thick , the ceiling should be fiber composite sheets. The entire penal are painted with Poly Urethrene paint ( Colour as appoved by Engineer In-Charge). The doors should be of 20mm Fiber Composite with PU Rigid Foam, Fire retardent Resin.The doors, windows :shall be of 32mm to 40mm extruded aluminum/UPVC sections with necessary signed boards of Engaged/ Vacant type latches etc. all complete including flooring of anti-skid tiles 400mm x400mmx8mm thick duly fitted with requisite adhesive base sheet not less than 20mm thick.The said unit should have in-built water supply overhead container of minimum of 2000 liters capacity and required connections for refilling and use.Proper sewerage collection tanks of requisite size-2000litres or more to serve the purposeof collection of the sewerage. The said toilet block should be supported with overhead tanks supported by detachable stands and sewerage collection tank of capacity not less than 4000litres with pressure pumps of required pumping capacity.Proper pumping system for fresh water as wellas sewerage waters to be provided with plugged-in connections to make the toilet block versatile to be shifted and connected at different locations as per the need of the GTDC. The plumbing of the Toilet block should be of UPVC pipes and fittings and the Shower, Taps all such material should be of Jaguar premium or equivalent make.The sanitary fittings such as W.C. , wash basins, sink etc. should be ISI marks of Stainless Steel as per ISI standards .The wiring and electrificationshould be concealed type with fire proof ISI Heavy duty wire of not less than 1.0Sq.mm. and 2.5 Sq.mm. Multi stand copper wires. The light fittings should be of LED concealed lights suitable for Solar , should be Hybrid so as to work solar as well as GED connections. Size of Solar Panel to be 200 Wp or more with MS mounting frame suitable for rooftop installation with 11.5V/60Ah Lithium Titanium Oxide(LTO) Battery with 10,000 Charge-Discharge cycle,2.3V/ 20000mAh with BMS and Solar CCU 15Amp. The battery should be suffifient to charge all the LED lights and exhaust fans. proper Exhaust Fans or circulation fans to be provided for keeping the unit well ventilated and lighted to have a pleasant conditions during use and non –use state. The said unit shall be of above specifications and as per the approved plan of the said toilet block (model) should got approved by the Engineer-in-charge .The work is inclusive of all such materials required for proper functioning of the mobile toilets all complete. GENTS TOILET, LADIES TOILET WITH CHANGING ROOMS as per drawing approved by Engineer incharge, and as instructed during factory inspection complete as required.
Providing woodwork in frames of doors, windows, clerestory windows trusses & other frames wrought framed and fixed in positon. First class Indian teak wood
Providing and fixing first class Indian teak wood moulded beading to door and window frames with iron screws , plugs and priming coat on unexposed surfaces etc. 50x12mm size.
Providing and fixing block board flush door shutters 35mm thick ( 1st Class Teak ply on both faces), laminated on both sides with 1mm thick laminate of approved brand and colour including cost of Adhesive, Nails, screws during fixing etc. complete.
Providing & fixing bright finished Stainless Steel mortise latch & lock with 60 mm Cylinder and a pair of levers, handles with necessary screws etc.complete
Providing and fixing bright finished brass door latch with necessary screws etc complete. 300x 16 x 5 mm
Providing and fixing bright finished Stainless Steel bearing hinges of 127 x 76 x 3 mm with necessary screws etc All works complete as per the drawing, specification and direction of the Engineer-In-Charge-In-Charge
Provided and fixing 150 mm chromium plated brass floor door stopper with rubber cushion screws etc. to suit shutters thickness complete.
Providing and fixing bright finished brass tower bolts (barrel type) with screws etc. complete 200 x 10 mm
Providing FRP door shutters 35mm thick with frame size in clear opening of 0.75x2.10m hinges and screws complete.,
Providing and fixing of aluminium window with 3 tracks and 2 shutters sliding window with tobular frame ployster powder if thicness 75-80 microns with approved standard accessaries such as ball beaing rollers, concealed lock, 6mm thick plain clear glass with EPDM beading etc.
Providing and fixing anodized aluminum ventilators (including frame and shutter ) with three partitions with 5 mm thick approved clear float glass in one partition, Exhaust opening in one partition & 6 mm thk glass louvers in one partition with using weight and size of section not less then as specified or as shown in drawing ,locking arrangement,silicon sealant ,EPDM gaskets, including all aluminum fixture and fittings etc. complete . All gaps between civil work and aluminium frames shall be sealed and made watertight by applying silicone sealant.Rectangular tube @0.478kg/m
Providing and fixing JIELI BRAND or Equivalent resin coated 3mm thk UPVC roof tiles sheets along with ridges/ valleys to required profile, including accessories such as tapping screws etc. excluding the cost of purlins rafter and trusses.
PLUMBING WORKS
Providing and fixing white vitreous china type water closet squatting pan (european type w.c. pan) with Dual Flushing (citren Nelson/ similar)with stop cock wall flanges flush pipe or elbow and vacuum breaker coupling etc. including cutting making good the walls and floors where required. (excluding handicap toilets)
Providing and fixing Hand Shower (Health Faucet) with 8mm dia, ABS/brass body with double lock 1.00m long Flexible tube (Brass plated stainless steel flexible hose) and wall hook of approved quality confirming to IS standards. (all EWC including Handicap toilets)
Providing and fixing NICKEL chrome plated copper alloy Fancy long body bib cock with wall flange Jaquar make or equivalent. Confirming to IS 8931;1993 for orissa pan. 15mm nominal bore
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430 x 260 x 350 mm and 340 x 430 x 265 mm sizes respectively with PVC automatic flushing cistern with fittings, R.S. or C.I. brackets, standard size galvanized steel flush pipe and spreaders with brass unions & G.I. clamps complete, including painting of cistern and fittings, cutting and making good the walls and floors where required. (a)One urinal basin with 5 liters p .v .c. automatic flushing cistern.
Providing and fixing vitreous china wash basin with RS or C.I. brackets painted white, 15 mm C.P. brass pillar taps C.P. brass chain with rubber plug 32 mm C.P. brass waste of pattern, 32 mm diameter M.I. or C.P. brass trap and union complete, including cutting and making good the walls where required. Flat back wash basin size 550 x 400mm with a single 15 mm C.P. brass pillar taps.
Providing and fixing NICKEL chrome plated copper alloy Fancy BOTTLE TRAP ECONOMY TYPE 32MM Jaquar make or equivalent. Confirming to IS 8931;1993
Providing & fixing liquid soap container with C. P. brass lid and brackets fixed to wooden cleats with C. P. brass screws Plastic container
Providing and fixing nahani trap of rigid PVC (approved make) for S.W.R. Pipes including lubricating etc. complete, without door : 110mm
Providing and fixing nahani trap of rigid PVC (approved make) for S.W.R. Pipes including lubricating etc. complete, without door : 75mm
Providing and fixing rigid PVC S.W. R. (soil, waste and rain water drainage pipes of approved make including lubricant etc. complete (single/double) socket-ed : 110mm dia
Providing and fixing rigid PVC S.W. R. (soil, waste and rain water drainage pipes of approved make including lubricant etc. complete (single/double) socket-ed : 75mm dia
Providing and fixing rigid PVC bend of required degree (of approved make) for S.W.R. drainage pipes of approved including lubricating. 110mm
Providing and fixing rigid PVC bend of required degree (of approved make) for S.W.R. drainage pipes of approved including lubricating. 75mm
Providing and fixing rigid PVC bend (approved make ) for S.W.R. pipes including lubricating etc complete bend with door : 110mm
Providing and fixing rigid PVC bend (approved make ) for S.W.R. pipes including lubricating etc complete bend with door : 75 mm
Providing and fixing single Tee of rigid PVC (approved make ) for S.W.R. pipes including lubricating etc complete, with door : 110mm
Providing and fixing single Tee of rigid PVC (approved make ) for S.W.R. pipes including lubricating etc complete, with door : 75mm
Providing and fixing single “Y” of rigid PVC (approved make ) for S.W.R. pipes including lubricating etc complete, without door 110mm
Providing and fixing single “Y” of rigid PVC (approved make ) for S.W.R. pipes including lubricating etc complete, without door 75mm
Providing and fixing R.P.V.C. vent cowl: 110mm
Providing and fixing R.P.V.C. vent cowl: 75mm
Construction of manhole rectangular in shape including cement concrete 1:3:6 (1 cement:3 coarse sand:6 graded stone aggregate 20mm nominal size) foundation thickness of concrete 20cms and offset 10cms on both sides and first class brick work with bricks class designation 100kg/cm2 in cement mortar 1:3 (1 cement : 3 coarse sand) 23cms thick including providing & fixing CI footrests confirming to IS 5445/69 or revised and whose weight shall not be less than 5.30kgs including fixing in man-hole at 30cm c / c in 20x 20x10cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) and 12mm thick plaster inside and outside with cement mortar 1:3 (1 cement : 3 coarse sand) including adding waterproofing compound of approved brand in cement mortar with a floating coat of neat cement and making channel in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20m nominal size) neatly finished complete as per standard design. Inside size 0.60x0.60m and 0.60m deep (with medium duty DI manhole cover & frame of size 0.60x 0.60m weighing 90kgs ) including fixing with cement concrete 1:2:4 ( 1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size and applying the frame & cover with coal tar.
Providing and fixing square mouth S.W. Gully trap grade “A” complete with C.I. Grating brick masonry chamber and water tight C.I. Cover with frame of 300 x 300 mm size (Inside the weight of the cover to be not less than 4.53 kg.) And frame to be not less than 2.72 kg as per standard design:. b) 150 x 100 mm size P or S type
Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including jointing of pipes & fittings with one step UPVC solvent cement, trenching ,refilling & testing of joints complete as per direction of Engineer. External work. SCH-80(blue)/(white) 25mm outer dia.
Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including jointing of pipes & fittings with one step UPVC solvent cement, trenching ,refilling & testing of joints complete as per direction of Engineer. External work. SCH-80(blue)/(white) 32mm outer dia.
Providing and fixing brass full way valve (heavy) duty with wheel of approved quality : (Toilet internal Ball valve, 15mm nominal bore
Providing and fixing brass full way valve (heavy) duty with wheel of approved quality : (Toilet internal Ball valve, 40 mm nominal bore .
Providing and fixing ball valve ( brass ) of approved quality Low pressure with copper floats 25 mm nominal bore
Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-in-charge. Internal work exposed on wall (Medium duty SDR 13.5 15 mm
Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-in-charge. Internal work exposed on wall (Medium duty SDR 13.5 20 mm
Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-in-charge. Internal work exposed on wall (Medium duty SDR 13.5 25 mm
Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-in-charge. Internal work exposed on wall (Medium duty SDR 13.5 32 mm
Providing at store or site work non-pressure RCC pipes of with collar joints conforming to IS:458-2003 revised as per amendment No.11 , including freight, carting, loading, unloading, stacking etc. complete 150 mm
Conveying carefully from stack at site, 250m from both sides rolling and lowering into trenches, laying and jointing true to line and level, RCC spun pressure and non pressure pipes of various classes, specials including collar and perfect linking of joint with jack to correct position including cost of jointing material in cement mortar 1:2, necessary hydraulic testing, curing of cement mortar etc. complete. 150 mm
Providing and placing on terrace roof of floor two (1st flor roof single piece rotational moulded polythene water storage tank having I S I mark and conforming to I S 12701;1996. 1000 lit. capacity
Constructing soak pit 1.20m x 1.20m x1.20m filled with laterite stone aggregate 125 to 180 mm including S.W. drain pipe 100 mm diameter and 1.2m. Long complete as per standard design
Providing and fixing, Testing & Commissioning of Submersible Pumpset (WORKING +STAND BY) capacity 1 LPS & Head 15 m, Casing - CI (Corrosion Proof), Impeller - CI, Shaft - SS, Hardwares - Stainless Steel, Double mechanical seal, Common Wall Mounted Control Panel with Potential Free Contacts for both Pumps & all alarms along with all valve arrangement with vibration isolator factory assembled & tested for rated efficiency complete with TEFC motor EFF3 rating for working and stand by pumps
ELECTRICAL WORKS
Supply ,Installation,Testing & Commisioning of 3 m high Decorative galvanised mild steel step pole and Mild steel base plate of Ø 268(may vary as per make) mm with 4 no. elliptical holes on 210 mm(may vary as per make) PCD suitable for M12 bolts,OD-65 to 76 MM,Complete with all required accessories like Junction box ( Window cover is fitted with allen screws to the pole & Opening Window 300 x110 mm approx.)with 15A Input output connectors , 0.5 - 6 A C curve SP MCB for suitable for each light fittings 3 Core 2.5 Sq. mm Cu Flex. cable for light fitting from Junction box to Light fittings and its termination of cables should be made using with proper lugs ,Pole will Be Painted with P U Paint as per GTDC color choice .etc.
Supply ,Installation,Testing & Commisioning of LED Street decorative post top mounting light fitting of 45 W,including lamp, with PF > 0.95,class IP 65 and above Housing of pressure die cast aluminium alloy and heat sink extruded aluminium Complete with all required accessories.
Supply ,Installation,Testing & Commisioning of 3 m high galvanised Decorative conical pole with Decorative Street light bracket made from 40 mm. dia ‘B’ class G.I. Pipe, 0.6m. in length along with pole cap of 300mm length and 80 mm dia.(Suitable to pole top) duly welded with provided leads, and with foundation bolts having bottom dia. from 105 to 115 mm, top dia. From 65 to 75 mm Complete with all required accessories like Junction box with 15A Input output connectors , 0.5 - 6 A C curve SP MCB for suitable for each light fittings 3 Core 2.5 Sq. mm Cu Flex. cable for light fitting from Junction box to Light fittings and its termination of cables should be made using with proper lugs ,Pole will Be Painted with P U Paint as per GTDC color choice .etc.
Supply ,Installation,Testing & Commisioning of LED Street light fitting of 30W,including lamp, with PF > 0.95,class IP 65 and above Housing of pressure die cast aluminium alloy and heat sink extruded aluminium Complete with all required accessories.Efficacy =>100lm/W.
Supply ,Installation,Testing & Commisioning of 6 m high galvanised Decorative conical pole with Decorative Street light bracket for erection of Single fitting made from 40 mm. dia ‘B’ class G.I. pipe 1.0 m in length along with pole cap of 300 mm length 100 mm dia .(Suitable to pole top) duly welded and with foundation bolts having bottom dia. from 135 to 160 mm, top dia. from 65 to 75 mm on provided foundation, with all required accessories like Junction box with 15A Input output connectors , 0.5 - 6 A C curve SP MCB for suitable for each light fittings 3 Core 2.5 Sq. mm Cu Flex. cable for light fitting from Junction box to Light fittings and its termination of cables should be made using with proper lugs ,Pole will Be Painted with P U Paint as per GTDC color choice etc.
Supply ,Installation,Testing & Commisioning of 6 m high galvanised Decorative conical pole with Decorative Street light Double bracket for erection of fitting made from 40 mm. dia ‘B’ class G.I. pipe 1.0 m in length along with pole cap of 300 mm length 100 mm dia .(Suitable to pole top) duly welded and with foundation bolts having bottom dia. from 135 to 160 mm, top dia. from 65 to 75 mm on provided foundation, with all required accessories like Junction box with 15A Input output connectors , 0.5 - 6 A C curve SP MCB for suitable for each light fittings 3 Core 2.5 Sq. mm Cu Flex. cable for light fitting from Junction box to Light fittings and its termination of cables should be made using with proper lugs ,Pole will Be Painted with P U Paint as per GTDC color choice etc.
Supply ,Installation,Testing & Commisioning of LED Street light fitting of 60W,including lamp, with PF > 0.95,class IP 65 and above Housing of pressure die cast aluminium alloy and heat sink extruded aluminium Complete with all required accessories .Efficacy =>100lm/W.
Supply of 3 core unarmoured PVC/XLPE insulated, PVC sheathed copper conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. 3 Core 4 sq.mm
Supply of 3 core armoured PVC/XLPE insulated, PVC sheathed copper conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. 3 Core 4 sq.mm
Supply of 4 core armoured PVC/XLPE insulated, PVC sheathed copper conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. 4 Core 4 sq.mm
Supply of 3 1/2 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. 3 1/2 Core 35 sq.mm
Supply of 3 1/2 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. 3 1/2 Core 50 sq.mm
Supply of 3 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. 3 Core 16 sq.mm
Supply of 4 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. 4 Core 16 sq.mm
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm in the existing RCC/HUME/STONEWARE Metal pipe, etc. complete as required
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required. a) In soily strata
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required. (a) In soily strata
Laying of one number additional PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground in the same trench in one tier horizontal formation including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required. a) In soily strata
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm on surface, etc. complete as required
Construction of manhole rectangular in shape including cement concrete 1:3:6 (1 cement:3 coarse sand:6 graded stone aggregate 20mm nominal size) foundation thickness of concrete 20cms and offset 10cms on both sides and first class brick work with bricks class designation 100kg/sq.cm (wire cut bricks) cement mortar 1:3 (1 cement : 3 coarse sand) 23cms thick including providing & fixing CI footrests confirming to IS 5445/69 or revised and whose weight shall not be less than 5.30kgs including fixing in man-hole at 30cm c / c in 20x 20x10cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) and 12mm thick plaster inside and outside with cement mortar 1:3 (1 cement : 3 coarse sand) including adding waterproofing compound of approved brand in cement mortar with a floating coat of neat cement and making channel in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20m nominal size) neatly finished complete as per standard design. III) Inside size 0.60x0.60m and 0.60m deep (with medium duty DI manhole cover & frame of size 0.60x 0.60m weighing 90kgs ) including fixing with cement concrete 1:2:4 ( 1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size and applying the frame & cover with coal tar.(Refer Quantity in drawings)
Providing at store or site work non-pressure RCC pipes of with collar joints conforming to IS:458-2003 revised as per amendment No.11 , including freight, carting, loading, unloading, stacking etc. complete. b) 100 mm Dia.NP2 Class
Supplying and laying of 40 mm outside dia. double wall corrugated pipes (DWC-750 N) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Supplying and Installation of couplers without ring for jointing & related all accessories.
Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 3 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 3 x 4 Sq. mm.
Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 4 x 4 Sq. mm.
Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 3 1/2 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 3 1/2 x 35 Sq. mm.
Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 3 1/2 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 3 1/2 x 50 Sq. mm.
Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 3 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 3 x 16 Sq. mm.
Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 4 x 16 Sq. mm.
Supply, installation, testing and commissioning of electronic type three phase energy meter (KWh), 4 wire, ISI marked, in polycarbonate or sgheet steel body ( base mounting type) with counter display/LCD display, with ELT, in Class 1.0, 50 Hz, 240 V. AC duly tested by MRT along with Test Certificates, complete as required of following capacity of make L & T only. (b) 10 to 40 A
Supply of 1 to 6 KVA 3 Phase Unbalanced fan air cooled Static voltage stabilizer with technology of DSP Based IGBT PWM Switching,Input voltage range (V L-L) =320-480 ,Output voltage (V L-L) =400 V ,Output Voltage Regulation = 1% of nominal output voltage,Automatics High & low Voltage cut off input and out put voltage Circuit protections, single phasing preventer/Phase reversal protection,over load & Short circuit protection(Use MCB),Independent Phase Control,LCD /LED Display for regulations mode ,Bypass mode & fault conditions,Automatic bypass: A Fault conditions,Protection Class : IP 20 ,Ambient Temperature : 0 to 45 Degree Celsius ,Wave form Distortion:pure sine wave.
Supply of 6 KVA 3 Phase Unbalanced fan air cooled Static voltage stabilizer with technology of DSP Based IGBT PWM Switching,Input voltage range (V L-L) =320-480 ,Output voltage (V L-L) =400 V ,Output Voltage Regulation = 1% of nominal output voltage,Automatics High & low Voltage cut off input and out put voltage Circuit protections, single phasing preventer/Phase reversal protection,over load & Short circuit protection(Use MCB),Independent Phase Control,LCD /LED Display for regulations mode ,Bypass mode & fault conditions,Automatic bypass: A Fault conditions,Protection Class : IP 20 ,Ambient Temperature : 0 to 45 Degree Celsius ,Wave form Distortion:pure sine wave.
Supplying and fixing following way SPN sheet steel MCB distribution board Consumer Unit 240 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar hinged front acrylic cover for the MCB knobs detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required ( but without MCB/RCCB/Isolator) (a) 2 + 4 way Cat A
Supplying and fixing 6 A to 32 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. a) SP, Cat A
Supplying and fixing 6 A to 32 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. b) DP, Cat A
Supplying and fixing 6 A to 32 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. c) TPN, Cat A
Supplying and fixing following rating four pole (triple pole and neutral) 415 V RCCB having a sensitivity current upto 300mA in the existing MCB DB complete with connections testing and commissioning etc as required (a) 25 A, Cat A
Supplying and fixing following way TPN sheet steel, double door, Horizontal type MCB distribution board 415 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required ( but without MCB/RCCB/Isolator) 4 way (8+12), double door, Horizontal type Cat B
Supplying and fixing SP blanking plate in the existing MCB DB complete as required.
SITC of Cable Junction Boxes IP 66/67 “weather proof”(Size -155 x 210 x 92 (LXBXH)mm + Cable termination upto 16 Sqmm size.), for outdoor installation(with knockouts for cable entry) with all accessories.(Extra Quantity is considered.)
Isolator 2 Pole 40A, Cat A
Earthing with GI earth pipe 2 mts long 40 mm dia medium class with ISI mark, of approved brands including accessories and providing masonry enclosure with CI/RCC cover having locking /Lifting arrangement and watering pipe etc. (but without charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer-Incharge.The scope of work includes the following: a) Excavation of pit of size not less than 1.0x1.0x 2.0 mtrs(min) and disposal of excavated soil. b) Class B GI pipe, 40mm diameter as per specifications. c) Charcoal/salt as per specs ( paid seperately). d) Refilling the pit of size not less than 1.0x1.0x 2.0 mtrs(min) with soft black soil of minimum resistivity i/c transportation. e)Masonary chamber with proper foundation, cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. Aluminium tag with embossed earthing value to be attached to the pipe . g)watering arrangement(plumbing will be paid seperately). (b) In rocky strata
Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosure with CI/RCC cover having locking/Lifting arrangement and watering pipe etc. (but without charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer-Incharge.The scope of work includes the following: a) Excavation of pit of size 1.0x1.0x 3.0 mtrs(min) and disposal of excavated soil. c)Watering GI pipe, 20mm, Class B, with funnel as per specs. d) Charcoal/salt as per specs ( paid seperately). e) Refilling the pit of size 1.0x1.0x 3.0 mtrs(min) with soft black agriculture soil of minimum resistivity i/c transportation. e)Masonary chamber with proper foundation, cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. Aluminium tag with embossed earthing value to be attached to the pipe.g)watering arrangement(plumbing will be paid seperately). b)In rocky strata
Earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonry enclosure with CI/RCC cover having locking/lifting arrangement and watering pipe etc. (but without charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer-Incharge.The scope of work includes the following: a) Excavation of pit of size 1.0x1.0x 3.0 mtrs(min) and disposal of excavated soil. c)Watering GI pipe, 20 mm Class B, with funnel as per specs. d) Charcoal/salt as per specs ( paid seperately). e) Refilling the pit of size 1.0x1.0x 3.0 mtrs(min) with soft black agriculture soil of minimum resistivity i/c transportation. e)Masonary chamber with proper foundation, cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. g)watering arrangement(plumbing will be paid seperately). In soily strata
Extra for using salt and charcoal for pipe earth electrode as required( 65 Kgs of Charcoal and 5 Kgs of Salt).
Supplying and laying 25 mm x 6 mm GI strip at 0.5 m below ground as strip earth electrode including soldering etc. as required
Providing and fixing 25 mm x 5 mm GI strip on surface or in recess for coneections etc. as required
Supplying and laying 6 SWG GI wire at 0.5 m below ground level for conductor earth electrode including soldering etc. as required
Supplying and laying 8 SWG copper wire at 0.5 m below ground level for conductor earth electrode including soldering etc. as required
Providing and fixing 4 mm dia copper wire on surface or in recess for loop arthing . as required
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed PVC conduit(heavy) with modular switch, modular plates, suitable size modular GI box of specified Category and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. a) Group B -- with Cat A Modular Accessories
Wiring for group controlled light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable (with)in recessed PVC conduit(heavy) and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the (with) independent recessed PVC conduit(heavy) of appropriate size as required. b) 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earthwire (20mm Conduit)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the (with) independent recessed PVC conduit(heavy) of appropriate size as required. (c) 2 x 4 sq.mm + 1 x 4 sq.mm earthwire (20mm Conduit)
Supplying and fixing of following sizes of rigid PVC conduit alongwith accessories in surface(medium)/recess(heavy) including cutting the wall and making good the same in case of recessed conduit as required. b) 25 mm
Supplying and fixing following modular switch/ socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required (a) 5/6 A switch Cat A
Supplying and fixing following modular switch/ socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required (d) 3 pin 5/6 A socket outlet Cat A
Supplying and fixing following modular switch/ socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required b) 15/16 A switch Cat A
Supplying and fixing following modular switch/ socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required d) 6 pin 15/16 A socket outlet Cat A
Supplying and fixing modular blanking plate on the existing modular plate switch box excluding modular plate etc. as required a) Cat A
Supplying and fixing following size modular GI box alongwith modular base and cover plate for modulator switches in recess etc. as required b) 4 Module ( 125 mm x 7 mm) Cat A
Supplying and fixing following size modular GI box alongwith modular base and cover plate for modulator switches in recess etc. as required (c) 6 Module (200mm x 75 mm) Cat A
Supplying & erecting of LED 9 to 10W tube light fitting (2 feet) with aluminium housing, heat sink, integrated HF electronic driver complete.
Supplying & erecting of LED 20W tube light fitting (4 feet) with aluminium housing, heat sink, integrated HF electronic driver complete.
Supplying and erecting of LED Light with integrated driver including 12W lamp with having pressure die-cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete.
Supply and erecting of 12 inch (300 mm sweep) exhaust fan with double ball bearings, 1400 rpm, complete with all accessories. (a) Cat A
Supply and erecting of 48 inch ( 1200mm sweep) ceiling fan, double ball bearing type, , complete with all accessories. (b) Cat B
Supply and erecting fan hook box ( 100 mm diameter or equivalent square size, 75mm deep) fabricated out of 16 SWG sheet steel with 10 m round bar hook bounded to RCC steel upto 50 mm length protruding on each side of the box, including painting with 2 coats of red oxide, complete as required.
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required (a) Cat A
GI Pipe Medium Class 25 mm
Supply of 3kVA ,1Ph IN - 1Ph OUT true Online UPS System in standalone configuration with advance DSP based technology’ Double conversion IGBT Rectifier and IGBT based inverter UPS system with cabinet and SMF battery backup for 60 mins. using 12V batteries including battery protection M.S Rack suitable dimension, standard rating cable for interlinks cable and D.C cable up to standard Length in mtrs from UPS to batteries including labour charges for installation testing and commission and carrying charges.
Supplying and Installing following size Perforated type 16 SWG, M.S.cable tray of GI pre-galvanised/hot dip galvanised/ powder coated finish, in convenient sections, joined with connectors, suspended from the ceiling with suitable MS suspenders including bolts and nuts, painting suspenders etc, complete as required. 150mm width x 50mm depth
Supplying and Installing following size perforated type , M.S.cable tray bends of GI pregalvanised/hot dip galvanised/ powder coated finish, in convenient sections, joined with connectors, suspended from the ceiling with suitable MS suspenders including bolts and nuts, painting suspenders etc, complete as required. 150mm width x 50mm depth (16 SWG)
Supplying and Installing following size perforated type , M.S.cable tray tees of GI pregalvanised/hot dip galvanised/ powder coated finish, in convenient sections, joined with connectors, suspended from the ceiling with suitable MS suspenders including bolts and nuts, painting suspenders etc, complete as required. 150mm width x 50mm depth (16 SWG)
Providing and fixing of lightning conductor finial made of 25 mm dia 300 mm long copper tube having single prong at top with 85 mm dia 3 mm thick GI base plate including holes etc. complete as required
Reverting sweating and soldering of copper/ GI tape ( with another copper/ GI tape base of the finial or any other metallic object) as required
Providing and fixing GI tape 20 mm x 3 mm thick on parapet or surface of all for lightning conductor complete as required ( for horizontal run)
Providing and fixing GI tape 20 mm x 3 mm thick on parapet or surface of all for lightning conductor complete as required ( for verticle run)
Providing and fixing testing joint made of 20 mm x 3 mm thick GI strip 125 mm long with 4 Nos of tinned brass bolts nuts check nuts and spring washers etc. complete as required
Providing and laying GI tape 32 mm x 6 mm from earth electrode directly in ground as required
Dismantling of all existing civil, electrical and plumbing items & Salvage Items
City Constructions
Mallikarjun Group of Industries
I B CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .