Loading…
Loading…
Tender Value
₹59.7 L
EMD Value
₹1.1 L
Closing Date
16 Jul 2026, 6:00 pm
Similar tender results from the same govt authority in the past 3 years.
CWE (A) Jaisalmer
HQ CWE ARMY JAISALMER 345001 RAJASTHAN
MAINT AND REPAIRS TO LT DISTRIBUTION PANELS, LT UG CABLE NETWORK AND ASSOCIATED WORKS FOR VARIOUS UNITS UNDER GE (A) JAISALMER
2026_MES_773700_1
84438/C/E8
Open Tender
Electrical and Maintenance Works
270 days
JAISALMER
AS PER NIT
8 documents required · 8 mandatory
₹1,000
GE ARMY JAISALMER
₹1.1 L
Yes
20 Jun 2026
20 Jun 2026
18 Jul 2026
20 Jun 2026
16 Jul 2026
11 Jul 2026
20 Jun 2026 - 27 Jun 2026
M&L in replacement for heat shrinkable Straight through jointing kit for LT 1.1 KV XLPE cables 25 to 4 core including all accessories required complete all as specified and directed by Engineer-in-Charge.
M&L in replacement for heat shrinkable Straight through jointing kit for LT 1.1 KV XLPE cables 35 Sqmm 3.5 core including all accessories required complete all as specified and directed by Engineer-in-Charge.
M&L in replacement for heat shrinkable Straight through jointing kit for LT 1.1 KV XLPE cables 50 Sqmm 3.5 core including all accessories required complete all as specified and directed by Engineer-in-Charge.
M&L in replacement for heat shrinkable Straight through jointing kit for LT 1.1 KV XLPE cables 70 Sqmm 3.5 core including all accessories required complete all as specified and directed by Engineer-in-Charge.
M&L in replacement for heat shrinkable Straight through jointing kit for LT 1.1 KV XLPE cables 95 Sqmm 3.5 core including all accessories required complete all as specified and directed by Engineer-in-Charge.
M&L in replacement for heat shrinkable Straight through jointing kit for LT 1.1 KV XLPE cables 120 qmm 3.5 core including all accessories required complete all as specified and directed by Engineer-in-Charge.
M&L in replacement for heat shrinkable Straight through jointing kit for LT 1.1 KV XLPE cables 150 Sqmm 3.5 core including all accessories required complete all as specified and directed by Engineer-in-Charge.
M&L in replacement for heat shrinkable Straight through jointing kit for LT 1.1 KV XLPE cables 185 Sqmm 3.5 core including all accessories required complete all as specified and directed by Engineer-in-Charge.
M&L in replacement for heat shrinkable Straight through jointing kit for LT 1.1 KV XLPE cables 240 Sqmm 3.5 core including all accessories required complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate & salt up to ground level connected to galvanized iron strip 25 x 3 mm as earthing lead by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection including all necessary earth work, excavation, earth chamber with PCC 1:3:6, type C1 and RCC chamber cover of PCC 1:2:4 with handle and 20mm dia GI watering pipe with funnel and wire mesh etc and testing on complete all as specified and directed by Engineer-in-Charge.
S & F in repair 25 mm x 3 mm aluminum strip as earth continuity conductor complete all as specified and directed by Engineer-in-Charge.
S&F in repairs earth chambers by demolishing unserviceable earth chambers and fixing new chambers of PCC 1:3:6 type C1 bed and chamber RCC 1:2:4 type B1 of size (600X600X200)mm and thickness 120 mm and and PCC top cover 50mm thick ( necessary hinges to be provided) complete all as specified and directed by Engineer-in-Charge.
S&F 1100 volts grade heavy duty PVC insulated, FRLS, ISI mark, stranded aluminium conductor of size 6 sqmm twin core flat cable incliding taking down old unserviceable cable complete all as specified and directed by Engineer-in-Charge.
All as per item No. 15.00 here-in-before above but size 10 Sqmm 2 core
S&F in replacement MCCB 400Amps, 4 pole, 36 kA with thermal Adjustable magnetic release, Ics = 100% Icu, 415 volts, 50 Hz with with phase barrier/phase seperator/spacer with copper spreader links and required nut, bolts or other fixing accessories complete all as specified and directed by Engineer-in-Charge. Note:- The contractor shall have to procure the suitable MCCB for exising LT Panel.
All as per item No. 17.00 here-in-before above but rating MCCB 320 Amp 4P 36 KA, 415 volts with thermal Adjustable magnetic release
All as per item No. 17.00 here-in-before above but rating MCCB 250Amp 4P 36 KA, 415 volts with thermal Adjustable magnetic release
All as per item No. 17.00 here-in-before above but rating MCCB 200Amp 4P 25 KA, 415 volts with thermal Adjustable magnetic release
All as per item No. 17.00 here-in-before above but rating MCCB 160Amp 4P 25 KA, 415 volts with thermal Adjustable magnetic release
All as per item No. 17.00 here-in-before above but rating MCCB 125 Amp 4P, 25 KA, 415 volts with thermal Adjustable magnetic release
All as per item No. 17.00 here-in-before above but rating MCCB 100Amp 4P, 16 KA, 415 volts with thermal Adjustable magnetic release
All as per item No. 17.00 here-in-before above but rating MCCB 63 Amp 4P, 16 KA, 415 volts with thermal Adjustable magnetic release
S&F MCB TPN 100 Amps 415 Vrupturing capacity 10 KA with connecting links on LT panel/feeder pillar including dismantling/taking down existing old unserviceable MCB complete all as specified and directed by Engineer-in-Charge.
S&F MCB TPN 63 Amps 415 V rupturing capacity 10 KA with connecting links on LT panel/feeder pillar including dismantling/taking down existing old unserviceable MCB complete all as specified and directed by Engineer-in-Charge.
S&F in repair MCB Triple pole and netural rated capacity 32 Amps, 415 volts breaking capacity 10 KA complete all as specified and directed by Engineer-in-Charge.
S&F in repair MCB Single pole and netural rated capacity 40 Amps, 240 volts breaking capacity 10 KA complete all as specified and directed by Engineer-in-Charge.
Taking down/ out unserviceable UG cables of any cross sectional area, any type, any make from trench/ from wall/pole/fixed with walls/ including pulling through pipe by opening connections and joints including removing pipe, carefully getting out briks/cable cover/half round reinforced concrete pipe etc complete all as specified and directed by Engineer-in-Charge.
Supply, laying, jointing and testing 1100 volts grade XLPE insulated, PVC sheathed (heavy duty) electric strip/ wire armoured electric cable of size 16 Sqmm 4 core with stranded aluminium conductor, laid in trenches, through DWC pipes, in floor, in duct, through pipes or Road crossing complete all as specified and directed by Engineer-in-Charge. Note: Earthwork excavation sand cushioning, Jodhpur stone patti, GI protcetion pipe shall be measured and paid separately in their respective items.
All as per item No. 30.00 here-in-before above but size 25 sqmm 3.5 Core
All as per item No. 30.00 here-in-before above but size 35 sqmm 3.5 Core
All as per item No. 30.00 here-in-before above but size 50 sqmm 3.5 Core
All as per item No. 30.00 here-in-before above but size 70 sqmm 3.5 Core
All as per item No. 30.00 here-in-before above but size 95 sqmm 3.5 Core
All as per item No. 30.00 here-in-before above but size 120 sqmm 3.5 Core
All as per item No. 30.00 here-in-before above but size 150 sqmm 3.5 Core
All as per item No. 30.00 here-in-before above but size 185 sqmm 3.5 Core
All as per item No. 30.00 here-in-before above but size 240 sqmm 3.5 Core
Supply, laying and Jointing 50mm X 38 mm outer dia and inner dia, HDPE double walled corrugated (DWC) pipe conforming to IS-16205 with antirodent and non flame propogating properties of approved colour including necessay fittings like bend, tee, elbow,socket etc. for cable protection complete all as specified and directed by Engineer-in-Charge. Note :- Joints are designed to be watertight and moisture proof.
All as per item No. 40.00 here-in-before above but size 75mm X 61 mm outer dia and inner dia
All as per item No. 40.00 here-in-before above but size 90 mm X 76 mm outer dia and inner dia
All as per item No. 40.00 here-in-before above but size 110 mm X 93 mm outer dia and inner dia
All as per item No. 40.00 here-in-before above but size 120 mm X 103 mm outer dia and inner dia
Excavation in trenches not exceeding 1.5 m wide and not exc. 1.5 m depth for laying cables, foundation for pole etc and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Returing, filling in, including spreading, leveling watering and well ramming in layers not exceeding 25 cms thick each layer complete all as specified and directed by Engineer-in-Charge.
Removing excavated material to distance n. exc 50m and depositing where directed at a level n. exc 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge.
S&F GI Pipe , light grade 50 mm bore , confirming to IS-1239, for cable protection on poles/ walls/ Road crossing/ floor crossing complete all as specified and directed by Engineer-in-Charge.
All as per item No. 48.00 here-in-before above but size 80mm bore
All as per item No. 48.00 here-in-before above but size 100mm bore
M&L for repair/replacement of LT panel/ Switchgear panel doors made up of MS CRCA sheet powder coated having two coats of smoke grey enamel paint over a coat of redoxide coat having 3.15mm thickness , cut to size and pressed to shape required as per size of existing LT panels installed/ located at various locations/site including welding, fixing of hinges to sheet, provn of suitable locking arrangements, fixing of sliding bolts (sliding bolts shall be measured under relevant item of Sch) and further fixing to LT panel/ switchgear panel for fixing complete all as specified and directed by Engineer-in-Charge. Note : The contractor have to get measured size of LT panel doors on ground for suitable fitting of doors.
S&F butt hinges, heavyweight, cold rolled mild steel of size 125 mm and fixed properly on MS CRCA sheet of thickness 2 to 3.15 mm after including dismantling old from LT panel complete all as specified and directed by Engineer-in-Charge.
M&L in replacement of Mild steel sliding door bolts, plate type, stainless steel finish, with bright bolt not less than 12mm dia, length 250mm with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete to LT panel door with welding or suitable means with any type of work involved complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of LT cable route route indicator made out of 3 mm thick MS sheet of suitable size (As approved by Engr-In-Charge) duly painted with two coats black paint over a coat of red oxide primer and writing cable direction,Nature of cable,size of the cable (in Sqmm),type of cable(LT Cable) with white paint , mounted on angle iron 40X40X3mm, angle height 45 cm,(30 cm below ground level) with PCC complete all as specified and directed by Engineer-in-Charge.
Repair/maintenance of APFC panel board up to 150 KVAR capacity with replacement of unserviceable spare part/ components modification of control wiring as required and make functional including flexible copper wire lugs etc complete all as directed by Engineer-in -Charge. Note :- The parts are measured and paid separately under respective items.
Supply only APFC controller 12 step for automatic correction of power factor suitable for 415 volt 3 phase power supply,able to display parametres KWH, VOLTAGE,KVArH, FREQUENCY,POWER FACTOR etc with suitable size PVC insulated FRLS copper wire including suitable size of CTs complete all as specified and directed by Engineer-in-Charge.
Supply only Moulded CT 100/5 VA class-I rectangular shape complete all as specified and directed by Engineer-in-Charge.
Supply only Moulded CT 125/5 VA class-I rectangular shape complete all as specified and directed by Engineer-in-Charge.
Supply only Moulded CT 150/5 VA class-I rectangular shape complete all as specified and directed by Engineer-in-Charge.
S&F in replacement Capacitor 1 KVAR, MPP heavy duty, Cylindrical type 415 V 3 Phase (ISI Mark ) complete all as specified and directed by Engineer-in-Charge.
S&F in replacement Capacitor 2 KVAR, MPP heavy duty, Cylindrical type 415 V 3 Phase (ISI Mark ) complete all as specified and directed by Engineer-in-Charge.
S&F in replacement Capacitor 5 KVAR, MPP heavy duty, Cylindrical type 415 V 3 Phase (ISI Mark) complete all as specified and directed by Engineer-in-Charge.
S&F in replacement Capacitor 7.5 KVAR, MPP heavy duty, Cylindrical type 415 V 3 Phase (ISI Mark) complete all as specified and directed by Engineer-in-Charge.
S&F in replacement Capacitor 10 KVAR, MPP heavy duty, Cylindrical type 415 V 3 Phase (ISI Mark) complete all as specified and directed by Engineer-in-Charge.
S&F in replacement Capacitor 12.5 KVAR, MPP heavy duty, Cylindrical type 415 V 3 Phase (ISI Mark) complete all as specified and directed by Engineer-in-Charge.
S&F in replacement Capacitor 20 KVAR, MPP heavy duty, Cylindrical type 415 V 3 Phase (ISI Mark) complete all as specified and directed by Engineer-in-Charge.
S&F in replacement LED Phase indicators red, yellow and blue 240 V, AC complete all as specified and directed by Engineer-in-Charge.
S&F in replacement Capacitor heavy duty Contactors AC-3 18 A sutable for 5 KVAR rating @ 415 V, 3 Phase complete all as specified and directed by Engineer-in-Charge.
S&F in replacement Capacitor heavy duty Contactors AC-3 25 A to 32 A sutable for 10 KVAR rating @ 415 V, 3 Phase complete all as specified and directed by Engineer-in-Charge.
S&F in replacement Capacitor heavy duty Contactors AC-3 40 A to 50 A sutable for 15 KVAR rating @ 415 V, 3 Phase complete all as specified and directed by Engineer-in-Charge.
S&F in replacement Capacitor heavy duty Contactors AC-3 80 A to 90 A sutable for 30 KVAR rating @ 415 V, 3 Phase complete all as specified and directed by Engineer-in-Charge.
S&F in replacement Heavy Aluminium lugs suitable for 150 to 185 Sqmm UG cable, crimping and connecting with MCCB complete incl disconnecting cables and making necessary connections after fixing lugs complete all as specified and directed by Engineer-in-Charge.
S&F in replacement Heavy Aluminium lugs suitable for 95 to 120 Sqmm UG cable, crimping and connecting with MCCB complete incl disconnecting cables and making necessary connections after fixing lugs complete all as specified and directed by Engineer-in-Charge.
S&F in replacement Heavy Aluminium lugs suitable for 35 to 70 Sqmm UG cable, crimping and connecting with MCCB complete incl disconnecting cables and making necessary connections after fixing lugs complete all as specified and directed by Engineer-in-Charge.
S&F in replacement Heavy Aluminium lugs suitable for 10 to 25 Sqmm UG cable, crimping and connecting with MCCB complete incl disconnecting cables and making necessary connections after fixing lugs complete all as specified and directed by Engineer-in-Charge.
M&L for cutting of existing road/ hard standing /wall by providing suitable T&P to make suitable size bore for fixing 100/80/50/40/ mm dia pipe . including the cost of making good the disturbed surface and matching with existing (Chequered tiles/Road/PCC) complete all as specified and directed by Engineer-in-Charge.
Supply, installing, testing and commissioning out door type LT feeder piller box, padestal mounted, CPRI type tested factory made totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and the panel shall be mounted on 50x50x6mm angle iron stand of height 45cm above ground and 45 cm embeded in ground on suitable PCC foundations. Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided complete and including taking down existing old unserviceable Panel etc complete all as specified and directed by Engineer-in-Charge. The panel shall consists of following accessories:- Incoming Side:- (i) MCCB 4P of capacity 400 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 36 KA with microprocessor based release (Ics=100% Icu) - 01 No (ii) Digital type Multifunctinal meter CT operated class 1 accuracy suitable for measuring v, A,PF,kW,kva etc 3 Phase, 4 digit, high resolution, LED type with one side programmability – 01 No. (iii) Indicator lamp with holder key flush mounted,LED type Red, yellow, blue with toggle switch– 03 Nos.
Item No. 79.00 Contd... (iv) Bus bar strips made of Aluminium 600 Amps (Based on 1.6 Amps per sqmm) – 04 Nos aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round ) insulators of suitable size and good insulation resistance OUTGOING:- (i) MCCB 4 Pole of capacity 160 Amp , breaking capacity 25KA with thermal release - 01 Nos (ii) MCCB 4 Pole of capacity 100 Amp , breaking capacity 25 KA with thermal release -02 No (iii) MCCB TPN 63 Amp 415 V, 'C' Curve, 10 KA -06 Nos (iv) Internal control wiring with 1100 volt grade 1.5 Sq.mm stranded copper cable as per colour coding for all connections with suitable size lugs as required and as specified.
Supply, installing, testing and commissioning out door type LT feeder piller box, padestal mounted, CPRI type tested factory made totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and the panel shall be mounted on 50x50x6mm angle iron stand of height 45cm above ground and 45 cm embeded in ground on suitable PCC foundations. Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided complete and including taking down existing old unserviceable Panel etc complete all as specified and directed by Engineer-in-Charge. The panel shall consists of following accessories:- Incoming Side:- (i) MCCB 4P of capacity 200 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 36 KA withmicroprocessor based release (Ics=100% Icu) - 01 No (ii) Digital type Multifunctinal meter CT operated class 1 accuracy suitable for measuring v, A,PF,kW,kva etc 3 Phase, 4 digit, high resolution, LED type with one side programmability – 01 No. (iii) Indicator lamp with holder key flush mounted,LED type Red, yellow, blue with toggle switch– 03 Nos.
Item No. 80.00 Contd... (iv) Bus bar strips made of Aluminium 300 Amps – 04 Nos aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round) insulators of suitable size and good insulation resistance OUTGOING:- (i) MCCB 4 Pole of capacity 160 Amp , breaking capacity 25KA with thermal release- - 01 Nos (ii) MCCB 4 Pole of capacity 100 Amp , breaking capacity 25 KA with thermal release -02 No (iii) MCBTPN 63 Amp 415 V, 'C' Curve, 10 KA -03 Nos (iv) MCB SPN 63 Amp 230 V, 'C' Curve -02 Nos (v) Internal control wiring with 1100 volt grade 1.5 Sq.mm stranded copper cable as per colour coding for all connections with suitable size lugs as required and as specified.
Please Enable Macros to View BoQ information
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.41 MB
BOQ_866321.xls
BOQ • 0.29 MB
TENDER_84438.pdf
Tender Documents • 3.56 MB
Download all tender documents and submit your bid