Tender Value
₹22.1 L
EMD Value
₹44,247
Closing Date
23 Jun 2025, 2:00 pmClosed
Executive Engineer
Office of the Executive Engineer, PWD, Jalukbari, Guwahati Central and New Guwahati Territorial Building Division, Jalukbari, Guwahati-13
FRP treatment of damaged slab of Academic Building of Assam Engineering College, Guwahati under SOPD-G during the year 2024-25
2025_PWBNH_44758_1
CS/JGCNGTBD/E-21_AEC
Open Tender
Civil Works - Building
Works
45 days
Jalukbari, Guwahati-13
Please refer tender documents.
4 documents required · 4 mandatory
₹1,000
₹44,247
Yes
o/o the E.E. P.W.D. JGCNGTBD Jalukbari-13
7 Jul 2025
5 Jun 2025
23 Jun 2025
5 Jun 2025
23 Jun 2025
5 Jun 2025
9 Jun 2025
Amount
Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges,making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge 50mm average thickness
Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. Bars upto 12 mm diameter
Bars above 12 mm diameter
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make
Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. 50 mm average thickness in 3 layers.
Providing & fixing Polyethylene joint filler board in expansion joints manufactured by M/s Supreme Industries Limited or equivalent. 500gms per sq. Mtr (Density not less than 30kg/cum) followed by Providing & fixing expansion joint tape of 2mm Thickness as per instruction of engineer in charge.
FRP Laminates on Slab:- Providing and lying a Externally Bonded Carbon Fibre Reinforced plate of thickness 1.4 mm in Iongitudinal direction at required spacing as per manufacturer specification. The carbon fibre plated should be installed after proper surface preparation application of primer and epoxy adhesive like Fosroc Nitowrap 40/ Rearm bond 4031 as instructed by the engineer in charge. The carbon fibre plates should have young's modulus more than 165000, elongation more than 7.7 0/o and tensile strength more than 2800 N/mm2. Cost inclusive of both design, application as per the satisfaction of engineer in charge,
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 6.4.1 Cement mortar 1:4 (1 cement : 4 coarse sand
Providing and laying cement concrete in retaining walls, return walls,walls (any thickness) including attached pilasters, columns, piers,abutments, pillars, posts, struts, buttresses, string or lacing courses,parapets, coping, bed blocks, anchor blocks, plain window sills, fillets,sunken floor etc., up to floor five level, excluding the cost of centering,shuttering and finishing: 4.2.2 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. above plinth level up tofloor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and fixing sheet covering over expansion joints with iron screws as per design Aluminium fluted strips 3.15 mm thick. 5.29.2.1 150 mm wide
Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 200mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-In-Charge. 26.30.1 Upto and including 12mm dia.
Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge.
Suspended floors, roofs, landings, balconies and access platform
RANJIT KUMAR CHAKRABARTY (BID ID -270492)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .