Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.9 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹30.5 L+₹2.3 L (8.18%)Rejected-Finance 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹33.8 L+₹5.7 L (20.1%)Rejected-Finance RZ 40 PALAM VIHAR DWARKA SECTOR 6 NEW DELHI 75 | NEW DELHI | DELHI | 75 | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹37.0 L+₹8.8 L (31.3%)Rejected-Finance RZ 1 7 167 GALI NO 6 DURGA PARK NASIRPUR SOUTH WEST DELHI DELHI 110045 | SOUTH WEST | DELHI | 110045 | L4 | Rejected-Finance Other than Lowest | |
| 5 | L5₹41.8 L+₹13.6 L (48.4%)Rejected-Finance HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD PIN 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L5 | Rejected-Finance Other than Lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
28 Feb 2023, 6:00 pmClosed
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
GE UTILITY PLANT AND MACHINERY KIRBY PLACE DELHI CANTT-10
COMPREHENSIVE MAINTENANCE OF DG SET AND REPAIR/ REPLACEMENT OF AMF PANELS AND MISC ITEMS OF DG SET AT VARIOUS LOCATIONS UNDER GE(U) PM DELHI CANTT 10
2023_MES_578174_1
GE(U)/PM/D-68/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
334 days
DELHI CANTT
MES contractor enlisted under class D category b(i) having deposited standing security of Rs 100000 with department. Contractor not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category.
6 documents required · 6 mandatory
₹500
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
₹90,000
Yes
16 Mar 2023
31 Jan 2023
2 Mar 2023
31 Jan 2023
28 Feb 2023
14 Feb 2023
Amount
Comprehensive Maintenance of DG Sets with AMF Panel of Make: M/s Cummins and M/s Kirloskar including preventive maintenance checks of engine and alternator for trouble free function as per recommendation and attending break down/ complaint as and when required basis,monthly maintenance are regular basis. complete with Preventive maintenance('B' check) twice a year inclusive replacement of required necessary spares engine oil,coolent,Filters such as Fuel filter, by pass filter , lube oil filter and Air filter complete sets along with rectification of minor defects and cleaning of coolent tank with blower and filling/topping up and replacement of engine oil/coolant and tuning of engine for DG set as listed below all as specified and directed by Engr-in-charge.
500 KVA DG Set -01 No ( Location:- Karam vihar )
320 KVA DG Set -01 Nos ( Location:- Piru vihar )
250 KVA DG Set -06 Nos ( Location:- Rangpuri,Naraina & Tigris road)
200 KVA DG Set -05 Nos( Location:- Kabul Line,Baird place, Naraina & Tigris road)
160 KVA DG Set -08 Nos ( Location:- Piru vihar,Kabul Line & Naraina )
140 KVA DG Set -02 Nos ( Location:- Todapure & Urban Village )
100 KVA DG Set -02 Nos ( Location:- Baird place )
125 KVA DG Set -01 Nos ( Location:- Kabul line )
82.5 KVA DG Set -02 Nos ( Location:- Kabul line Type-V & VI )
62.5 KVA DG Set -02 Nos ( Location:- Kabul line )
NOTE FOR ITEM NOS: 1.1 to 1.10:- (a) After monthly maintenance, the work to be certified by JE (E/M)/Engr-In-Charge on Job Card. (b) Cost of materials and labour as mentioned in Section-2 are not included with Comprehensive Maintanance, i.e. item No. 1.1 to 1.10 here-in-before. (c) The DG Set shall be maintained by the respective OEMs i.e.M/s Cummins and M/s Kirloskar or their authorized service dealer. (d) The comprehensive maintanance of DG Set under this contract shall be done through OEMs i.e. .M/s Cummins and M/s Kirloskar or their authorized service dealer. The contractor will have to submit MoU on stamp paper of Rs. 100/- duly notarized as per performa (on serial page No 114 & 115) within fifteen days of acceptance of tender, failing which the contract will be liable to be cancelled and work will executed as per policy invouge of the contractors default.
Notes Contd.../ (e) The contractor should submit the monthly test report of DG Sets conducted by the OEM with in first week of every month to the Engr-in-Charge, failing which recovery of Rs. 2000/- per DG Set per month shall be deducted from contractors dues. (f) Contractor has to carry out monthly maintenance with examination of suction and exhaust valves for smooth operation of DG Sets. (g) The contractor should send Technician to attend/ rectify the complaints for all DG Sets during 24 Hrs as and when complaint lodged for breakdown on call basis for any No of times during the month. (h) Contractor shall be responsible to monitor the followings of all DG Sets during Comprehensive Maintenance and contractor shall detail one supervisor to moniter DG set daily and submit weekly once of running Hrs, fuel consumtion and function of each DG set ,the report to concerned Engr-in-Charge/ JE E/M, the cost of same is deemed to be included in the quoted rate:- (i) Examination of fuel injection, nozzles. (ii) Check clearnce of suction and exhaust valves and adjust if required, (iii) Checking of oil filters, fuel filters screen filters assy. (iv) Maintenance of coolant level all as directed by the Engineer-in-charge. (v) Change of Hydraulic governor oil (vi) Change of anerold oil
(vii) Clean alternator winding in position by forced air and internal surfaces lubricate DE & NDE bearings (viii) Tightining of all nut bolts. (ix) Greasing of all parts. (x) Test IR value of alternator winding and recording the readings (xi) Checking of any leaking in fuel & oil lines and rectification of the same. (xii) Any other check as reqd for efficient running of equipment all as specified & directed by Engr-in-Charge. (xiii) The rates quoted against the above mentioned Items is deemed to be included for cost of labour, cost of T & P required for replacement of unserviceable parts and cost of handling / transportation of defective item to & from civil workshop for repair if required. (j) The contractor shall carry out routine checking of the complete DG Sets and rectify the minor/major defects noticed immediately. If complaints were not . If complaints were not attended within 45 minutes the following penalties will be imposed and deducted from contractors dues :- (i) Rs. 500/- for not attending the complaint and keeping pending with in one hour/per complaint. (ii) Rs. 1000/- per complaint for not attending the complaint and keeping pending 2 hours to 8 hours/per complaint. (iii) Rs. 2000/- per complaint for not attending the complaint and
Section-II Supply and fixing in repairs of Rubber hose set for DG set of capacity 500KVA to 320 KVA complete all as specified and directed by Engr-in-charge. Make: As Per OEM Recommendation
ditto- all as per item No. 5 above but capacity of DG Set from 200 KVA to 250 KVA
ditto- all as per item No. 5 above but capacity of DG Set 100KVA to 160 KVA .
ditto- all as per item No. 5 above but capacity of DG Set 62.5KVA to 82.5 KVA.
Dismantling/ taking out old unserviceable self starter assembly 24 volts from the DG set. Material and labour for rewinding with super enamelled copper wire of existing size & insulating the field coil assy, replacing bentec assy of the self starter assembly 24 Volts and refixing the same after repairs and testing complete all as specified & directed by Engr-in-Charge. (Make:-FORD/ PRESTOLITE/ BOSCH/ DENSO/ MITSUBA)
ditto- all as per item No. 6 above but capacity of 12 Volts. (Make:-FORD/ PRESTOLITE/ BOSCH/ DENSO/ MITSUBA)
Supply and fixing in replacement of battery charger capacity 6 Amp, 12 Volts for DG set complete all as specified and directed by Engr-in-Charge. (Make:- SU-KAM/ AMCO/ SINETRAC/ WAC/ BCH/ AMARON.)
ditto- all as per item No 7 above but capacity of 15 Amp, 24 Volts for DG set. complete all as specified and directed by Engr-in-Charge. (Make:- SU-KAM/ AMCO/ SINETRAC/ WAC/ BCH/ AMARON.)
Supply and fixing in replacement aganist repairs of stop solenoid/ shut off valve of any capacity suitable for DG Sets of existing make along with screen Filter including wiring connecting to panel circuit, starting and testing on load complete all as specified and directed. Make: As Per OEM Recommendation
Supply & fixing in repairs of thermostat element alongwith complete assy for DG set connection and testing complete all as specified and directed by Engr-in-Charge.Make: As Per OEM Recommendation
Repairs and calibration of PT fuel pump as per the calibration procedure and norms as per manufacture's guide lines for DG Set of capacity from 500 to 250KVA including replacement of worn out and unserviceable"O'rings / shutt off valve/Plungers complete all as specified and directed
ditto- all as per item No 10 above butcapacity from 200 to 62.5KVA including replacement of worn out and unserviceable"O'rings / shutt off valve/Plungers complete all as specified and directed
Supply and fixing in replacement of Control assembly for DG Set capacity 200 to 320 KVA with necessary modification to controll wiring, replacement of controll relays , programming with all the parameters for safety protection and running suitable for the existing DG sets. of Make: Cummins/ Kirloskar
ditto- all as per item No. 11 above but capacity of DG Set from 160 KVA to 62.5 KVA.
Supply and fixing in replacement of PCB assembly for DG Set capacity 320 to 250 KVA with necessary modification to controll wiring, replacement of controll relays , programming with all the parameters for safety protection and running suitable for the existing DG sets . Make: As Per OEM Recommendation
ditto- all as per item No. 12 above but capacity of DG Set from 62.5 KVA to 250 KVA.
Supply and fixing in replacement of Automatic Voltage Regulator suitable for 320-100KVA DG set connecting with panel circuit, starting and testing on load all as specified and directed by Engineer-in-charge
Supply and fixing in replacement of Megnetic pickup Sensor suitable for 62.5 to 320 KVA DG set connecting with panel circuit, starting and testing on load all as specified and directed by Engineer-in-charge
Supply and fixing in replacement of Oil Pressure Sensor suitable for 62.5-320 KVA DG set connecting with panel circuit, starting and testing on load all as specified and directed by Engineer-in-charge
Supply and fixing in replacement of Coolant Tempetarure Sensor suitable for 100 -320 KVA DG set connecting with panel circuit, starting and testing on load all as specified and directed by Engineer-in-charge
Material & labour for opening / taking down radiator of DG set of any type / make and capacity cleaning / descaling using air compressor and cleaning with detergent etc and examining of water leakage of the same after cleaning , descaling and repairing of leakage, if any, using welding/brazing etc including replacement of all connecting parts i.e. radiator hose pipe with clamp, bolt, nut, washer, rubber bush, packing material etc and re-assembling the radiator, fitting with DG set properly in original position, checking the alignment, making proper hose connection, testing for smooth operation complete all as directed. Note : 1. The cost of replaced spares / parts is deemed to be included in quoted rates . 2. The cost of transportation (to and fro) for all kind of necessary equipment / T&P shall be arranged/brought by contractor to complete the job at site and no extra cost shall be paid to the contractor in this effect.
ditto- all as per item No. 17 above but capacity of 500 to320 KVA.
ditto- all as per item No. 17 above but capacity of160 to 250 KVA.
ditto- all as per item No. 17 above but capacity of 140 to 62.5 KVA.
Cleaning of diesel tank of various capacity DG set inside/ out side of tank complete with drain out DHPP(N) and cleaning tank and applying two coats of synthetic enamel paint (1st grade quality) on out side of tank and refilling the DHPP(N) & testing complete all as specified and directed by Engr-in-charge.
Material and labour for removing of oil deposits and cleaning all the external surface of the DG sets along with enclosures and connected pipe lines from oil/paint/corrosion flakes completely and applying two coats of heat retardant paint using spraying machine/air compressor for the following DG sets of the existing colour Complete all as specified and directed.
320 KVA capacity
160KVA to 250 KVA capacity
140KVA to 62.5 KVA capacity
Supply only Electronic timers with auxilary voltage of 110/240/415v 50Hz for operation of 12-120 secs . Make : L&T /Siemens/ ABB/ Legrand
Supply only Control relay contactors of MXO type operatable at AC/DC supplies with NO/NC add ON as per the existing Site requirement complete all as specified and directed. Make: As Per OEM Recommendation
Supply only of the following Power contactors Coils operatable at 230V/440V 50Hz Existing Make & Model . Make : L&T Siemens/Schneider/ Legrand/ ABB
Power Contactor Coil For 320-250 KVA Alternator AMF
Power Contactor Coil For 200-62.5 KVA Alternator AMF
Supply and fixing in replacement of Controller for AMF panel DG Set capacity 320 KVA to 500 KVA with necessary modification to controll wiring, replacement of controll relays , programming with all the parameters for safety protection and running suitable for the existing DG sets . Make: Deep-sea / woodward / power start of cummins / sedemac / L&T
ditto- all as per item No. 23 above but capacity of DG Set from 62.5 KVA to 250 KVA.
Supply&Fixing in replacment of 3 phase digital multi function meter with suitable accessories and fixing arrangements.complete all as specified and directed by Engr-in-charge. Make:- L&T/ ABB/ Siemens/ Legrand/ C&S Electricals.
S&F in replacament of LED type phase indicator to be fitted on panel ( R,Y , B as per site requirement) Make:- L&T/ ABB/ Siemens/ Legrand/ C&S Electricals.
Removal of defective MCCB/Power contactor any capacity and fixing only new MCCB/Power contactor on existing LT/AMF panel in replacement including al fixing arrangements complete all as specified and directed by the Engr-in-Charge. NOTE : New MCCB/Power contactor to be issued under schedule'B':
M & L to find out fault in LT line bring/call fault finding machine equipment and find out fault in any size of LT UG Cable including disconnecting of cable connection from both side panels/poles and necessary excavation in any type of strata to reach upto cable and making space for cable joint. Note:- (i) Cable required at site same size of faulty cable if required for jointing purpose will be paid in relevant item. (ii) Jointing material will be paid in relevant Item.Detect the location of default for supply of electricity with necessary machinaries or other applications for locate the pin point of the default of supply complete all as specified and as directed by the Engr-in-Charge.
M & L Cable jointing kit for 1.1 KV (Earthed) grade cable for straight through joint heat shrink type ( out door) complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25 sqmm to 50 sqmm all as specified and directed by Engr-in-Charge. MAKE:- DENSON/ M-SEAL/ BIRLA 3M/ RAYCHEM/CABSEAL
ditto- all as per item No. 31 above but size of cable 70 sqmm to 120 sqmm.
Laying only in replacement of LT underground cable any size and capacity including cable connecting lugs, glands,jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole,making hole in wall as per requirement at site complete all as directed by Eng-in-charge of following:- NOTE:- i) Earth work included in above item no 31.ii) New LT UG cable to be issued under schedule'B':
M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick, burried dirctly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead by means of bolts, nuts, check nuts and washer of galvanised iron strip 32 x 6mm as earth lead as shown in electrical plate No. 3 of SSR Part I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal od surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm bore GI tubing medium grade for watering pipe, 40mm bore medium grade GI pipe for protection of GI earth strip and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) tyep A1 duly reinforced with 8mm dia TMT bar @ 100 mm c/c both ways, one lifting handle made out of 10mm dia TMT bar 250mm long embedded in cover slab and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layer of 15 cm thick including taking down old unserviceable one complete all as specified and directed.
M & L for surface dressing and cutting of vegetation bushes, etc including cleaning/ maintenance of DG Sets instalations regularly.
M/S ANIL KUMAR
BUSINESS TEK INDIA
YASHVI ENGINEERS
national engineering
Charan sales and Service
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .