Garrison Engineer Chilka
Garrison Engineer Chilka INs Chilka Post Dist Khurda Odisha 752037
ADDITION / ALTERATION OF STATION HQ ECHS AND REGULATING OFFICE AREA INCLUDING TOILETS AREA , IN ARJUN AND ASHOK DIVISION INCL PROVN OF CERTAIN WORK IN GALLEY WASTE MANAGEMENT SHED, 500 MEN GALLEY AND AT NIVARINI AT INS CHILKA UNDER GE CHILKA
2019_MES_307518_1
GE/CHL/8625 OF 2019-20
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer Chilka
MES Enlisted Contractor of class E and category a (i)
6 documents required · 6 mandatory
₹500
Yes
Garrison Engineer Chilka
₹39,000
Yes
1 Feb 2020
19 Dec 2019
28 Jan 2020
19 Dec 2019
21 Jan 2020
6 Jan 2020
19 Dec 2019 - 27 Dec 2019
Amount
Excavation in trenches not exceeding.1.5m wide and not exceeding 1.5m in depth and getting out in hard/dense soil for laying of cable etc complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick in any type of soil complete all as specified and as directed.
Removing excavated surplus soils material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
M&L for natural river sand as in cushioning of cables including spreading and punning down complete all as specified and as directed. Note :-Punned thickness shall be measured for payment purpose.
M&L for cement concrete 1:5:10 type E-2 using 40 mm graded stone aggregate as in sunken floor complete all as specified and as directed.
M&L for cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in lintels upto 1.5 m clear span, cills, steps,coping and other similar works complete all as specified and as directed.
M&L for RCC 1:2:4 type B-1 using 20mm graded stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M&L for RCC 1:2:4 type B-1 using 20mm graded stone aggregate as slabs supported on walls, beams and columns in floors, roofs, landings, balconies and in shelves and the like complete all as specified and as directed.
M&L for RCC 1:2:4 type B-1 using 20mm graded stone aggregate as in chajjas complete all as specified and as directed.
M&L for cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed.
M&L for precast cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate, set in cement mortar 1:4 as in landings, cover slabs for manholes , shelves and similar articles complete all as specified as directed.
Supply only integral water proofing compound complete all as specified and as directed.
M&L for cutting holes in brick walls exceeding half brick but not exceeding one brick wall built in cement mortar for inserting hold fasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate complete all as specified and as directed.
M&L for brick work with fly Ash bricks, straight or curved on plain exceeding 6m means radius built in cement mortar 1:6 complete all as specified and as directed.
M&L for 18-20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like set in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite including moulding of corners as required complete all as specified and as directed.
Use and waste of formwork to chullah hoods, chajjas, troughs and similar articles including edges flat , rough finihsed surface of concrete complete all as specified and as directed.
Use and waste of formwork to sides and soffits of floor or roof beams, beam, lintels, cantilevers, shelves including supports, overhangs, etc, rough finished surfaces of concrete complete all as specified and as directed.
Use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landing and other similar work not exceeding 200mm thick (Horizontal or sloping) , rough finished surfaces of concrete complete all as specified and as directed.
Taking down chowkats or frames not exceeding 1.5 Sqm each but with shutters (without taking off shutters from the frames) complete all as specified and as directed.
Taking down chowkats or frames exceeding 1.5 Sqm but not exceeding 4.0 Sqm each but with shutters (without taking off shutters from the frame) complete all as specified and as directed.
S&F 300 mm long aluminium alloy, anodised sliding door bolt with hasp and staple(bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and as directed.
S&F 4 levers brass mortice lock , vertical type, size 100mm complete all as specified and as directed.
S&F aluminium (extruded section body) door closer hydraulically regulated, designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80kg and fixed complete all as specified and as directed.
S&F in repair brass chromium plated tubular towal rail 20mm dia , 600mm long between flanges complete all as specified and as directed.
S&F Solid PVC door frame of size 50mm x 47mm made out of 5mm single side prelam PVC sheet and edges will be painted to match with prelam sheet, reinforced with MS Square tube, fixing in opening as per specification complete all as specified and as directed.
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded both side Prelam PVC sheet used PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement & fixing in the frame at site as per specification and drawing given in SSR part-II 2010.
S&F 125mm size,Butt hinges, medium weight , cold rolled, mild steel and fixed complete all as specified and as directed.
S&F 125mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified and as directed.
S&F 125mm long aluminium anodised handle of extruded section fabricated type complete all as specified and as directed.
S&F powder coated anodised aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and as directed.
S&F aluminium shutters of any colour (thickness of powder coating not less than 50 micron) anodised aluminium door shutters, aluminium section weighing 0.55Kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, suitable handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc ccomplete all as specified and as directed. Note :- Glass and particle board shall be measured paid separately under respective item.
S&F for aluminium anodised powder coated of any colour (thickness of powder coated not less than 15 micron ) aluminium grill of Make "Deco grill" and model DG 202 with aperature size 60x40mm fixed with channel of suitable size complete all as specified and as directed.
S&F powder coated of any colour (thickness of powder coating not less than 50 micron) anodised aluminium window and ventilator shutters sliding /openable type without sash bar, aluminium section weighing 0.55Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and as directed. Note:- Glass shall be measured paid separately under respective item.
S&F mild steel framed work such as grills, gratings etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
S&F mild steel work for framed and hung portion as in gates,railing, balcony ralling including pintle hinges stops and sliding bolts etc complete all as specified and as directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L Water proofing treatment to sunken floors as per the following specification including testing:- (i) Preparation of sunken portion slab surfaces by removing all loose particles and sharp projection. (ii) Apply a coat of bitumen primer @0.5 kg /Sqm (iii) Apply a coat of blown bitumen of grade 85/25 @ 1.2 kg per sqm. (iv) Apply water proofing membrane of 3mm thick hyper plus weight not less than 3kg/sqm with 10cm over lap on joints and torching the joints. (v) Apply a coat of blown bitumenn 85/25 grade @ 1.2 kg per sqm over the water proofing membrance.
M&L for water proofing roof treatment, consists of a five layered Atactic polypropylene modified polymeric membrane of minimum weighing 3kg per sqm and a minimum 3 mm thick and reinforced with polyster non woven fabric (weight not less than 150 gm/sqm), laid with LPG torch forced application over roof surface, with a side & end overlaps of minimum 100 mm, with including priming the surface with a coat of hot blown bitumen of grade 85/25 @ 1.2 kg/Sqm at top and bottom of the membrane as bonding material and a coat of bituminous aluminium primer @ 100 gm/Sqm on top of membrane including sealing all joints by thermo fusion complete all as per manufacturer's instructions.with priming surfaces with bituminious primer @0.5 kg/sqm including testingcomplete all as specified and as directed.
Taking down existing water proofing treatment completely of any description from brick or RCC wall and RCC slab by scrapping including removal of rubbish where directed to a distance not exceeding 100m complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L for 7 to 8 mm thick coloured non skid ceramic tiles , area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed or bedding layer in cement mortar 1:4 complete all as specified and as directed.
M&L for 7 to 8 mm thick coloured non skid ceramic tiles , area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed or bedding layer in cement mortar 1:4 complete all as specified and as directed.
M&L for roughening surface of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry @3.0 kg/sqm complete all as specified and as directed.
M&L for 10mm thick light shade Vitrified ceramic tiles (square/rectangular) area of each tile not exceeding 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick bedding layer in cement mortar 1:4 complete all as specified and as directed.
M&L for 10mm thick light shade Vitrified ceramic tiles (square/rectangular) as in skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and as directed.
M&L for coloured glazed ceramic tiles as in vertical surface 350mmx250mmx7mm/ 450mmX350mmX7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and as directed.
M&L for 50mm thick cement concrete1:2:4 type B-1 using 20mm graded stone aggregate as in sub base (sunken floor) , surface finished even and smooth without using extra cement complete all as specified and as directed.
M&L for suspended false ceiling consisting of gypsum board 12mm thick in ceiling fixed with screw in Gl frame work for seamless ceiling (size of grid 605x605mm) comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete all as specified and as directed.
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
M&L for 5 mm thick rendering in cement mortar 1:3 on ceiling , surface finished even and fair complete all as specified and as directed.
M&L for 10 mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar 1:6, surface finished even and fair complete all as specified and as directed.
M&L for 15mm thick rendering in two layers on fair faces of brick work or concrete surfaces in cement mortar 1:4 (Ist layer 10 mm thick and second layer 5 mm thick), top layer mixed with WPC @ 3% by weight of cement, surface finished even and fair complete all as specified and as directed. Note:-WPC shall be measured and paid separately under respective item.
M&L for 10 mm thick rendering on fair faces of brick work or concrete surface in cement mortar 1:4 mixed with water proofing compound @ 3% by weight of cement , surface finished even and fair complete all as specified and as directed. Note:-WPC shall be measured and paid separately under respective item.
M&L for 15mm thick rendering on brick work or concrete surfaces in cement mortar 1:4 mixed with water proofing compound, surface finished even and smooth without using extra cement complete all as specified and as directed. Note:-WPC shall be measured and paid separately under respective item.
M&L for applying three coats of white wash on ceiling including preparation fo new plastered surface complete all as specified and as directed.
M&L for applying two coats of white wash on ceiling including preparation of old decorated surface complete all as specified and as directed.
M&L for applying two coats of oil bound distemper on wall over a coat of alkali resistant primer including preperation of new plastered surface complete all as specified and as directed.
M&L for applying two coats of oil bound distemper over a coat of alkali resistant primer over and including 1mm thick wall care putty after complete removal of existing treatment on old decorated wall surface complete all as specified and as directed.
M&L for applying two coats of white wash on wall including preparation of old decorated plastered surfaces complete all as specified and as directed.
Supply only 18 mm thick prelaminated particle board, interior grade, prelaminated both sides with decorative choice laminations and other side balancing white lamination, fixed with screws in aluminium frame work in aluminium doors complete complete all as specified and as directed.
Supply only 4.8 mm thick frosted glass, ordinary quality and glazing with beading in squares exceeding 0.5 sqm each pane complete all as specified and as directed.
Supply only 4 mm thick sheet glass, ordinary quality and glazing with oil putty or with beading in squares exceeding 0.5 sqm in each pane complete all as specified and as directed.
M&L applying two coat of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surface of any description over 10cm in width or girth complete all as specified and as directed.
M&L for applying two coats of oil bound distemper over clearcolle preparatory to distempering on ceiling including preperation of surfaces complete all as specified and as directed.
S&F 0.56mm thick plain aluminium sheeting Alloy 31000 H4 in stepped flashing (measured as the minimum rectangle from which the pieces can be cut) complete all as specified and as directed.
M&L for applying two coats of weather proof acrylic emulsion paint, exterior grade (100% acrylic) of approved shade over one coat of alkali resistant primer including applying 1 mm thick wall care putty as per manufacturer's instructions complete all as specified and as directed.
S&F in repair 125 mm size brass chromium plated shower rose with swivel joint fixed to steel pipe or union complete all as specified and as directed.
S&F in repair Vitreous China wash basin, white, flat back, size 550x400mm excluding taps, waste pipe but including brackets complete all as specified and as directed.
S&F 32 mm dia PVC waste pipe with cup head suitable for wash hand basin complete all as specified and as directed. Make:- Prayag cat No 329 or equivalent as approved.
S&F 32mm bore waste coupling of PTMT (half or full threaded) minimum weight 32mm-45gms complete all as specified and as directed.
S&F stainless steel sink with draining board made out of 1.0mm thick sheet for kitchen with plug , washers waste pipe , cast iron cantilever brackets connecting union over all size 915mm x 460mm with bowl size 410mm x 330mm x160mm complete all as specified and as directed.
S&F in repair 15 mm bore pillar tap , cast copper with capstan heads, chromium plated,fancy type , screwd down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and as directed.
S&F in repair 15 mm bore bib taps, fancy type chromium plated, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed.
S&F soap tray fixed with screw in the wall complete all as specified and as directed. Make:- Prayag cat No BA-05 or equivalent as approved.
S&F in repair Vitreous China bowl urinals flat back, size 465x355x265mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) including connections to flushing pipe and outgoing pipes complete all as specified and as directed.
S&F Urinal spreader of PTMT any colour for fixing with 15mm dia pipe (minimum weight 60gms) complete all as specified and as directed.
S&F 50mm bore low density polyethylene pipe(LDPE) of pressure rating 6 kgf/sqcm as in waste pipe to wash hand basin/urinal complete all as specified and as directed.
S&F in repair 15mm bore stop valves fancy type chromium plated , screwed down high presure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S&F in repair 110 mm bore PVC (SWR) pipes single socketed in any length with adhesive joint fixed to walls complete all as specified and as directed.
S&F in repair 75 mm bore PVC (SWR) pipes single socketed in any length with adhesive joint fixed to walls complete all as specified and as directed.
S&F in repair 110 bore PVC (SWR) bends any radius complete all as specified and as directed.
S&F in repair 75 bore PVC (SWR) bends any radius complete all as specified and as directed.
S&F in repair 75 mm bore PVC (SWR) junction single ,(single T ) equal or unequal complete all as specified and as directed.
S&F Grating doom 125 mm dia with waste hole of PTMT (minimum weight 40gms) complete all as specified and as directed.
S&F in repair 75 mm diameter of outlet PVC(SWR) floor trap with grating including jointing with solvent cement complete all as specified and as directed.
S&F in repair vitreous China squating pan of pattern long pan of size 580mm white with P or S trap front or back inlet and foot rests any pattern (excluding flushing cistern and flush pipe) including necessay connection complete all as specified and as directed.
S&F vitreous China wash down water closet pan (pedestal pattern),white (excluding fixing bolt,flushing cistern and flushing pipe) including necessay connection complete all as specified and as directed.
S&F in repair plastic water closet seat cover, white , closed pattern with flat bottom including chromium plated hinging device complete all as specified and as directed.
S&F Health faucet 1.5m long tube with hook including all necessary fitting complete all as specified and as directed. Make:- Prayag cat No 1881or equivalent as approved.
S&F in repair 10 litre capacity PVC low level valveless, syphonic action type, flushing cistern, white with inlet, ball valve, float and handle including brackets complete all as specified and as directed.
S&F 32 mm dia flush pipe of polyethylene of low or high density of PVC, for low level cistern complete all as specified and as directed.
S&F 32 mm dia bore PVC waste pipe with cup head for flushing cistern complete all as specified and as directed.
S&F 25 mm dia stainless steel curtain rod (16 gauge) (as per sample) complete all as specified and as directed.
S&F decorative brackets for curtain rod (as per sample) complete all as specified and as directed.
Taking up or down 15 mm dia steel tubing and connections including cleaning for refixing or removal to store complete all as specified and as directed.
Taking up or down 20 mm dia steel tubing and connections including cleaning for refixing or removal to store complete all as specified and as directed.
S&F 15mm bore galvanised iron water tubing, medium grade with all fittings such as bends, elbow socket etc fixed to walls, cellings or laid in floor complete all as specified and as directed.
S&F 20 mm bore galvanised iron water tubing, medium grade with all fittings such as bends, elbow socket etc fixed to walls, cellings or laid in floor complete all as specified and as directed.
Fixing only old 15mm dia bore steel water tubing and connections in new or old position (walls, ceiling, floors, etc) complete all as specified and as directed.
Fixing only old 20 mm dia bore steel water tubing and connections in new or old position (walls, ceiling, floors, etc) complete all as specified and as directed.
M&L for applying two coat of synthetic enamel paint including preparation of old painted steel surface complete all as specified and as directed.
Dismantliing wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
M&L for Disconnecting existing tanks 1000 litres capacity, setting aside (or lowering if required) for repairs, cleaning etc. and hoisting if required reconnecting and re-fixing in position after cleaning and removing all scale and dirt etc from tanks and from mouths of circulating pipes complete all as specified and as directed.
Supply only 25mm thick pre-formed filler for expansion joints complete all as specified and as directed.
S&F stainless steel floor grating strainer 12 inchx 4 inch with cockroach trap arrangement to be fitted in floor complete all as specified and as directed.
Supply and laying well burnt Fly ash brick of size 200x100x80mm locallly available as in cable protection laid in trenches complete all as specifed and as directed .
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
Demolition of roofs, floors (other than ground floors), beams staircases, landing, chajjas & similar suspended work cement concrete (reinforced) (reinforcement cut as required to facilitate demolition) complete all as specified and as directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
Demolition of brick masonry built in cement mortar complete all as specified and as directed.
Taking down carefully copper / aluminium point wiring(light,fan,socket or power) complete along with fittings such as switches, sockets, ceiling rose , lamp holder ,tube light fittings and making good distrubed surfaces on walls etc complete all as specified and as directed.
M & L for point wiring with PVC FRLS insulated unsheathed multi stranded copper conductor cable of size 1.5 sqmm drawn in concealed PVC conduit / casing caping not less than 20mm dia/ wide with all accessories including 1.5 sqmm copper conductor FRLS cable for earth continuity conductor of green colour including pressed steel concealed mild steel box duly covered with modular sheetsor 3 mm thick plastic laminiated Hylam sheet for mounting switch/sockets, accessories such as spacers, saddles, junction boxesfor one light point or fan point or exhaust fan point controlled by one switch, complete all as specified and as directed. Note :- Rate quoted is inclusive of necessary cutting chasing and making good to distrubed surface.
All as per item No. 115 above but for 5/6 Amp socket out let, on independent board complete all as specified and as directed.
All as per item No. 115 above but for 15/16 Amps socket out let on independent board with 4.0 sqmm copper cable of PVC insulated, unsheathed, multi stranded and 2.5 Sqmm for earth continuity conductor of PVC FRLS grade complete all as specified and as directed.
All as per item No.115 above but with 2.5 sqmm PVC insulated unsheathed multistranded copper cable FRLS grade with one run of 2.5 sqmm PVC insulated copper cable as earth continuity for power socket on independent board complete all as specified and as directed.
Taking down carefully sub main wiring including batten/ conduit by unscrewing from wall,ceiling and making good the disturbed surfaces to match complete all as specified and as directed.
S&F of sub main wiring with two runs of 4.0 sqmm PVC FRLS sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 4 sqmm FRLS drawn in and including PVC casing and caping not less than 25mm wide complete all as specified and as directed. Note:- 2 run of 4 sqmm copper cable, 1 run of 4 sqmm copper earth wire and PVC casing and caping shall be measured as one unit length.
S&F of sub main wiring with two runs of 6.0 sqmm PVC FRLS sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 6 sqmm FRLS drawn in and including PVC casing and caping not less than 25mm wide complete all as specified and as directed. Note:- 2 run of 6 sqmm copper cable, 1 run of 6 sqmm copper earth wire and PVC casing and caping shall be measured as one unit length.
S&F modular switch 1 way, 6 Amp,1 module, 230V complete all as specified and as directed.
M&L for Modular switch socket out let 3 pin 5 Amps flush type, 230V complete all as specified and as directed.
S&F Modular switch socket combination 2 in 1, 3 pin, 6/16 Amps, 230V complete all as specified and as directed.
S&F switch socket combination 2 pin & 3 pin 5Amp, 230 volt, multipurpose complete all as specified and as directed.
S&F switch socket combination 5 in 1 type, 3 pin 5 / 15Amp, 230 volt, multipurpose complete all as specified and as directed.
S&F sheet metal enclosure single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB 20 Amps , 240 volt complete all as specified and as directed.
S&F ceiling rose, surface Bakelite 65 x 30mm, three terminals 230V complete all as specified and as directed.
S&F 300 mm sweep, 900 rpm metal body heavy duty exhaust fans AC single phase 230/ 240 V with louver shutter complete all as specified and as directed. Make:- Havells cat part Turbo Force SP or equivalent in Bajaj or crompton greaves as approved
S&F 400 mm sweep wall mounted fans AC single phase 230/ 240 V complete all as specified and as directed. Make: Havells of Model Platina Remote or equivalent in Bajaj or crompton greaves as approved
S&F 18 W LED tubelight fitting with lamp, Endura linear LED wall mounted LED batten,extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver with complete fitting complete all as specified and as directed. Make:- Bajaj cat part No BCLSB 18 NW or equivalent to Havells or Crompton Greaves as approved
S&F 10 W LED tubelight fitting with lamp, Endura linear LED wall mounted LED batten,extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver with complete fitting complete all as specified and as directed. Make:- Bajaj cat part No BCLSB 10 NW or equivalent to Havells or Crompton Greaves as approved
S&F LED Downlighter 12 Watt AC suply 230 volt as per site requirement complete all as specified and as directed. Make:- Bajaj cat part No. BPSLR 12W NW equivalent to Havells or Crompton Greaves as approved
S&F 1X18/19/20 Watt indoor type retrofit batten type luminaries extruded polycarbonate / powder coated aluminium complete with LED retrofit T8 polycarbonate tube of capacity 18/19/20 Watt with decorative holder including connecting up with three core twisted flexible copper conductor cable of required length up to ceiling rose complete all as specified and as directed. Make : - Havells Cat Part No. REGALBATTENT8UPTO1X22WSSBSWH (Batten) and PHOTONULTRA1213T8SSTL18WLED865SPC (LED Lamp) or Wipro Cat Part No.W10921208 (Batten / Channel ) & LL13-181-65SE(LED Lamp) or Bajaj cat part No for Batten :BLRB-DB118 &Tube : BLRB 18W CWC or Philips Cat Part No.BN550WLED20-3000 as approved.
S&F double door MCB DB 04 way SPN with 200 Amp rated bus bar, 240 Volts, complete all as specified and as directed.
S&F MCB SP 6 to 32 Amps ,240 Volts , C-series breaking capacity 10 KA complete all as specified and as directed. Make:- C&S/Standard/Havells.
S&F 40 Amps RCB in place of defective old MCB's complete all as specified and as directed.
S&F switch paino, flush type, single pole, one way, 5/6 Amp, complete all as specified and as directed.
M&L for sub main wiring with 4 runs of 6 sqmm PVC FRLS unsheathed, copper conductor cable, 1100 volt and 2 runs 4 sqmm copper earth wire drawn in and including PVC casing & capping not less than 25 mm wide complete all as specified and as directed. Note :- 4 runs of copper conductor and one run of copper earth wire with PVC casing caping shall be measured as one unit length.
S&F sheet metal enclosure TPN DB 4 way single door with 200 amp rated bus bar complete all as specified and as directed.
S&F MCB TPN , 63 Amps, 415 volts , breaking capacity 10 KA, C-series complete all as specified and as directed.
S&F 380mm sweep exhaust fan , heavy duty AC single phase, 230 volts including connection with 0.5 sqmm copper conductor flexible wire from ceiling rose to connector of fan including necessary fixing arrangement and making good to disturbed surface complete all as specified as directed.
M&L for cutting openings, through brick / stone walls built in cement mortar for fixing exhaust fans of 380mm sweep including making good in cement mortar 1:4 to match with existing wall complete all as specified and as directed.
Supply, laying or fixing of LT XLPE cable 16 Sqmm 4 core, 1100 volt grade, insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (Heavy duty) with stranded aluminium conductor including connection with lugs, gland etc. complete all as specified and as directed. Make :- Polycab/Havells/Nicco/Gloster
S&F switch socket combination 2 pin & 3 pin 5 amp, 230 volt, multipurpose complete all as specified and as directed.
S&F switch socket combination 5 in 1 type, 3 pin 5 / 15Amp, 230 volt, multipurpose complete all as specified and as directed.
S&F stepped type electronic fan regulator for ceiling fan of any sweep including necessary connection complete all as specified and as directed.
S&F factory made sheet metal enclosure for DBs double door (fixed flush to the wall), SPN, 240 volt, 8 way, IP-42 protection with 200 amp rated bus bar complete all as specified and as directed. Make:- C&S/Standard/Havells.
M&L Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire 4.0 mm dia (upto 7.5 M in length from earth plate) by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of SSR Part-2009, connected to earthing with DBs all as specified including excavation and earth work in any type of soil, PCC 1:3:6 type C-1 using 20mm graded stone aggregate in chamber & 40mm thick RCC 1:2:4 type B-1 using 20mm graded stone aggregate as in cover slab, reinforced, with 8mm dia TMT bar at 150mm c/c both ways, 15mm dia GI pipe light grade for earth lead protection, 20mm dia GI medium grade pipe for watering , water funnel etc complete all as specified and testing on completion.
S&F PVC box of size 8 inchX10 inch for mounting accessories complete all as specified and as directed.
S&F Ceiling fan of 1200mm sweep with all accessories with neceessary mounting arrangement including necessary connection with three core flexible copper wire complete all as specified and as directed. Make :- Havells Model "ES-50, 5 Star" or equivalent in Bajaj/Khaitan as approved.
S&F triple pole and earth enclosure with a three pin and earth plug with socket complete with one triple pole MCB 63 Amps complete all as specified and directed.
S&F LED street light 25W, made up of pressure die cast aluminium housing with high power LED as lighting source and lens embeded PC cover having top opening separate driver compartment with IP66 protection and impact resistance of IK07 complete all as specified and directed Make :- Bajaj cat Part No.BRLEP 25W LED WH(product code 169826) or Havells Cat Part No ENDURAPEARLSL25WLED757SASYTOPC as approved.
S&F mild steel bracket made out of 25mm dia galvanised iron tube medium grade , bent to shape having length 1.5 M including welding bracket to the existing structure complete all as specified and directed
Supply, installation , commissioning and testing of electric driven Single phase 50Hz 240 Volt,Split AC of capacity 2.0 TR, 5 STAR BEE rating inverter type with rotary compressor and refrigerant type R -410A complete with inbuilt inverter and LCD remote control kit complete all as specified and as directed. Make:- Carrier model No. 18K5 star Ester Neo Hybrid inverter R-32(I015(/18k 5star Hybrijet inverter R-32 ODU(I015) copper condenser or equivalent in Hitachi/Blue star/Daikin as approved.
Supply, installation ,commissioning and testing of electric driven Single phase 50Hz 240 Volt,Split AC of capacity 1.5 TR, 5 STAR BEE rating inverter type with rotary compressor and Refrigerant type R 410A. complete with inbuilt inverter and LCD remote control kit complete all as specified and as directed Make:- Carrier Model No 24K5 star Ester Neo Hybridje inverter R-32(IO17(/24k 5 star Hybrijet inverter R-32 ODU(IO17) copper condenser or equivalent to Hitachi/Blue star/Daikin as approved
S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA all complete as specified and as directed. Make:- V- Guard VG 500 or equivalent in Microtek/ Matrix as approved
S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA complete all complete as specified and as directed. Make:- V- Guard VG 400 or equivalent in Microtek/ Matrix as approved.
HARI PALAI
SANJAYA KUMAR PALAI
SUBAL CHARAN PRADHAN
M/S JAGANNATH SASMAL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .