Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.1 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹14.2 L+₹1.1 L (8.29%)Rejected-Finance NEAR INDUSTRIAL ESTATE THANDA PADDAR UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹15.0 L+₹1.9 L (14.4%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹16.0 L+₹2.9 L (21.7%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹17.4 L+₹4.3 L (32.5%)Rejected-Finance R O H NO 55 SEC D BHARAT NAGAR TALAB TILLO JAMMU 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹23 L
EMD Value
₹46,000
Closing Date
20 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (I) 873 EWS
Garrison Engineer (Indep) 873 Engineer Works Section PIN 913 873 C/O 56 APO
REPAIR / REPLACEMENT OF STREET / SECURITY LIGHTS AND OTHER CONNECTED WORKS AT BHALRA MIL STATION UNDER GE (I) 873 EWS.
2022_MES_540525_1
NIT-41 of 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Bhadewah
As per NIT
7 documents required · 7 mandatory
₹500
Yes
GE (I) 873 EWS
₹46,000
Yes
25 Aug 2022
23 Jul 2022
23 Aug 2022
23 Jul 2022
20 Aug 2022
6 Aug 2022
Amount
Excavating in trenches, not exceeding 1.5metre wide and not exceeding 1.5metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick any type of soil, complete all as specified and directed.
Removing excavated soils to a distance exceeding 50m but not exceeding 100m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Cement concrete type C-2 1:3:6 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete for stay, complete all as specified and directed.
Cross arm bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, drilling holes for bolts, in any shape or size as indicated or directed and also inclusive of two coats of aluminium paint over one coat of red oxide primer including dismantling / taking down old unserviceable structural steel all as specified and as directed.
Aluminium conductor steel reinforced (ACSR) including binding to insulator with suitable size of binding wire and size of conductor Weasel (6/1 x 2.59 mm), Squirrel (6/1 x 2.11mm) or Ferret (6/1 x 3.00 mm), fixed in repairs, all as specified and as directed.
Pin type insulator porcelain vitereous white, brown or green including one galvanized mild steel spindle, two galvanised iron washers and one galvanized iron nut, 100mm height, 65mm dia for 1100 volts grade complet including taking down old unserviceable Pin type complete all as specified and directed.
Shackle type insulator porcelain vitereous white, brown or green including galvanised M.S. straps 31 x 5mm size, 75mm height, 95mm dia including galvanised mild steel straps, nut, bolts washers complete for 1100 volts grade insulator complete including taking up of old unserviceable Shakle type complete all as specified and directed.
Stay assembly complete with accessories as shown in Electrical Plate No.1 of SSR 2009 Part-I using stay rod of 16 mm dia, stay bow 14 mm dia, 400 mm long, MS Plate of size 300 x 300 mm x 6mm thick, GI staywire 7/4mm dia, stay clamp, Loop type insulator, vitreous white, brown or green large size with overall dimension 90 x 140mm with clearance of hole 16mm (Excavation and concrete shall be measured and paid separately) complete all as specified and directed.
Cutting and trimming of trees and branches to clear the over head line in the arc of HT/LT over head line feeders and removal of the trimmed branches of trees complete all as specified and directed. Notes : 1. Any ACSR conductor damaged during the cuttings of trees / branches shall be repaired and jointed / fixed by the contractor, to the entire satisfaction of Engr-in-Charge, without any extra cost and nothing extra shall be admissible from the department on this account what-so-ever. 2. The cutting / trimming of tree branches shall be done to atleast 2.00 metre radius of OH line. 3. The unit of measurement is 'SPAN' i.e. distance covered between two poles.
Restringing / Restretching / Tightening of old ACSR conductor of any size and make on LT Poles by disconnecting and removing from insulators including providing necessary binding wire and jumpering after proper stringing all as directed.
New Generation energy saving and environmental friendly long life Street Light fitting 60 Watts LED made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV built-in surge protection device including taking down old unserviceable Street Light Fitting all as specified and as directed. Make : Havells 'Endura Ominiplus' Cat Part No ENDURAOMINIPLUSSL60WLED757SASYTOPC or equivalent in Wipro / Philips / Crompton
New Generation energy saving and environmental friendly long life Street Light fitting 70 Watts LED made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV built-in surge protection device including taking down old unserviceable Street Light Fitting all as specified and as directed. Make : Havells 'Endura Ominiplus' Cat Part No ENDURAOMINIPLUSSL70WLED757SASYTOPC or equivalent in Wipro / Philips / Crompton
Energy saving environmental friendly, long life, exclusive innovative die-cast aluminium IP66 LED flood light 100 watt 230 V AC outdoor type suitable for highlighting architectural facade and general pupose lighting including taking down old unserviceable flood Light Fitting all as specified and as directed. Make : Havells Cat Part No JETAIRISFLS100WLED757SYMLTG or equivalent in Wipro / Philips / Crompton
New Generation, IP 65, LED CORAL LED POST TOP 25Watt, energy saving, environmental friendly, long life asthetically designed and symetrical light distribution, spun aluminium l;andscape luminaire with high power LEDs at light source, opal cover woth soothing uniform illumination complete and fixed as directed including taking down old unserviceable fitting . Make : Havells Cat Part No CORALPT25WLED830SSYMTOPC or equivalent in Wipro / Philips / Crompton
Supply and fixing in replacement of Sturdy LED Bollard 10watt LED Landscape light fitting with excellent light out put through its PMMA window ensuring maximum illumination aspect in surrounding complete and fixed as directed. Make : Havells Cat Part No MOUNTBL10WLED857PSYMTOPMMA or equivalent in Wipro / Philips / Crompton
Supply and fixing PVC junction box of size 250mm X250mmX 160mm with hinged type door and 2 Nos terminal 20 Amps MCB, fixed on pole with necessary fixing arrengement such as nuts, bolts, washers, clamps, etc. Complete all as specified and as directed. Make : Sintex Cat part No GSJB-2520 or equivalent in HPL/HAVELLS /HENSAL
Pole mounting bracket made out of medium grade GI pipe of 40mm dia, bent to 600 required shape of length 1.5 mtr with two No's of flat iron clamps made out of 32 x 6mm with 12mm dia bolts, nuts & washers duly painted with aluminium paint over a coat of primer including taking down old unserviceable brackets all as specified and as directed.
PVC insulated copper conductor 2.5 Sqmm, 4 core for connecting Street Light fitting to DB complete including taking down old unserviceable cable all as specified and as directed.
MCCB 160 Amps, breaking capacity 36 KA, FP, 415V (adjustable thermal and magnetic release) including taking down old, complete all as specified and as directed.
MCCB 100 Amps, breaking capacity 16 KA, TP, 415V (adjustable thermal and magnetic release) including taking down old, complete all as specified and as directed.
MCCB 63 Amps, breaking capacity 16 KA, TP, 415V (adjustable thermal and magnetic release) including taking down old, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 25 Sqmm 4 core on wall including taking down old cable, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 16 Sqmm 4 core on wall including taking down old cable, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 10 Sqmm 4 core on wall including taking down old cable, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 6 Sqmm 4 core on wall including taking down old cable, complete all as specified and as directed.
Sand cushioning to underground cables using new dry river sand laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete, punned to 18cm, complete all as specified and directed Note : Punned thickness of 18cms shall be measured for payment.
Sub class ‘B brick, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to the length of the brick, complete all as specified and directed.
Painting of steel tubular pole with cross arms with one coat of aluminium paint after preparation of surfaces of pole / cross arms by scrapping of old paint, cleaning of all rusted surface and painting upto 1.5metre above PCC coping in black and white strips 05 Nos of 30cms each starting from the bottom of the pole and two coats epoxy based paint aluminium grade finish to the remaining external surface of pole and cross arms structure over one coat of primer and marking of MES No complete all as specified and as directed.
Earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 1.5 meter (BGL) connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore “light grade” galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt, complete all as shown in EP No 3 of SSR 2009 Part-I, connected to test point complete, all as specified and testing on completion.
K S BUILDERS
SWASTIK TRADERS
SHARMA TRADERS
M/S Chib Engineers
Bidder Name
SWASTIK TRADERS
K S BUILDERS
M/S Chib Engineers
M/S Builders Indias
SHARMA TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .