Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.0 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹7.5 L+₹25,446.20 (3.52%)Rejected-Finance | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹8.2 L+₹95,734 (13.3%)Rejected-Finance NO 15 PULAVAR GOVINDAN STREET GANDHI NAGAR AVADI CHENNAI 600 054 | AVADI | CHENNAI | TAMIL NADU | 600054 | L3 | Rejected-Finance BEING L3 |
Tender Value
₹9.6 L
EMD Value
₹19,200
Closing Date
25 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I RD AVADI
AGE I RD AVADI CHENNAI
REPAIR / MAINTENANCE OF OF BUILDING SECURITY LIGHT UNDER CVRDE AVADI
2022_MES_560171_1
8541/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
CVRDE AVADI
AS PER NIT DOCUMENTS
8 documents required · 8 mandatory
₹500
AGE I RD AVADI
₹19,200
Yes
9 Jan 2023
29 Oct 2022
28 Nov 2022
29 Oct 2022
25 Nov 2022
11 Nov 2022
29 Oct 2022 - 11 Nov 2022
Amount
Taking down carefully existing unserviceable LED street light fittings of any capacity & size & any make from poles and refixing the same on existing location after making the LED fitting serviceable by replacement of defective drivers/surge protection device as required with new one complete all as specified and directed Note:- (i) Spare parts required for replacement shall be measured and paid separately under relevent items 2,3 . (ii) The cost of Replacement of minor Parts i.e. nuts/bolts,connectors etc are deemed to be included in this item.
Supply only constant current LED driver for energy saving & environment area light fitting upto 35 watts security light with active power factor correction (APFC) electronic driver with operating voltage between 100-270V AC of suitable for existing street light of make Surya/ C&S/ Crompton/ Havells/ Bajaj/ Philips/ Wipro complete all as specified and directed.
Supply only constant current LED driver for energy saving & environment area light fitting upto 70 watts security light with active power factor correction (APFC) electronic driver with operating voltage between 100-270V AC of suitable for existing street light of make Surya/ C&S/ Crompton/ Havells/ Bajaj/ Philips/ Wipro complete all as specified and directed.
S&F in replacement of LED street light fixture not less than 30 Watt LED with pressure die cast aluminium housing with toughened glass,IP-66 degree of protection, luminarie efficacy 100 lumen/watt, colour temperature (CCT) of 5700K with integral electronic driver, surge protection unit with suitable size GI bracket/clamps etc including making electrical connection for cable connection complete all as directed by Engineer-in-Charge. Make- VILUMINASL30WLED757PASYBOPC of Havells/ BRP050 LED 036 CW HP SLA FG S1 PSU GR of Philips ENXT P 36L WH CR PC SD 30W of Bajaj (Note: Equivalent latest updated brand in Havells/PHILIPS/BAJAJ)
S&F in replacement of LED street light fixture not less than 35 Watt LED with pressure die cast aluminium housing with toughened glass,IP-66 degree of protection, luminarie efficacy 100 lumen/watt, colour temperature (CCT) of 5700K with integral electronic driver, surge protection unit with suitable size GI bracket/clamps etc including making electrical connection for cable connection complete all as directed by Engineer-in-Charge. Make- ENDUCITYLITPLAT SL35WLED757SASYBOPCWOSPD of Havells/ BRP050 LED 035 CW HP SLA FG S1 PSU GR of Philips/ENXT P 35L PO PC SD 35W of Bajaj (Note: Equivalent latest updated brand in Havells/PHILIPS/BAJAJ)
S&F in replacement of LED street light fixture not less than 60Watt LED with pressure die cast aluminium housing with toughened glass,IP-66 degree of protection, luminarie efficacy 100 lumen/watt, colour temperature (CCT) of 5700K with integral electronic driver, surge protection unit with suitable size suitable size GI bracket/clamps etc including making electrical connection for cable connection complete all as directed by Engineer-in-Charge. Make: Havells Cat No ENDURAPWARLNEOSL60WLED757PASYTOPCAST/ ENXT P 72L WH PO PC SD 60W of Bajaj/ Wipro Cat part No LR02-781-XXX-57-G2(Note: Equivalent latest updated brand in Havells/wipro/Bajaj)
S&F in replacement of LED street light fixture not less than 70/72Watt LED with pressure die cast aluminium housing with toughened glass,IP-66 degree of protection, luminarie efficacy 100 lumen/watt, colour temperature (CCT) of 5700K with integral electronic driver, surge protection unit with suitable size GI bracket/clamps etc including making electrical connection for cable connection complete all as directed by Engineer-in-Charge. Make: Havells Cat No ENDURACITYLINERNEOSL70WLED757PASYBOTG/ ENXT P 84L WH PO PC SD 70W of Bajaj/ M/ Wipro Cat part No LR02-781-XXX-57-G2(Note: equivalent latest updated brand in Havells/wipro/Bajaj)
M&L for taking down unserviceable XLPE cable of any type and size from trench/duct/wall etc including taking down bricks for reuse and broken bricks removing from site complete all as specified and directed.
Supply and Laying XLPE cable of size 6 sqmm 2 core 1100 Volt grade heavy duty aluminium conductor laid in trenches / fixed to wall / pole / laid in floor including necessary connection and suitable size lugs/glandsas required complete all as specified and as directed.
Supply and Laying XLPE cable of size10 sqmm 2 core 1100 Volt grade heavy duty aluminium conductor laid in trenches / fixed to wall / pole / laid in floor including necessary connection and suitable size lugs/glandsas required complete all as specified and as directed.
Supply and Laying XLPE cable of size10 sqmm 4 core 1100 Volt grade heavy duty aluminium conductor laid in trenches / fixed to wall / pole / laid in floor including necessary connection and suitable size lugs/glandsas required complete all as specified and as directed.
Supply and laying GI pipe “light Grade” in trenches/under floors or roads or along the pole for protection of cables of 40 mm bore including taking down u/s GI pipe any type any size complete all as specified and as directed. complete all as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out Hard/dense soil
Retruning, filling, including spreading, levelling, watering and well ramming in layers not exc 25cms of soil complete all as specified and directed.
Removing the surplus excavated materisl/soil to a distance not exc 50Mtrs and depositing, where directed at a level not exceeding 2.5 Mtr above the starting point all as specified and directed.
Dry river sand cushioning / sand covering for underground cable protection complete all as specified. Note : Punned down thickness only shall be measured complete all as specified and directed
Supply and laying old size brick, size 230x115x75mm burnt clay building brick sub class (B) for protecting LT U/G cable complete.
Taking down and Supply and fix in replacement of analog time switch 24hours range suitable for autamatic ON/OFF control of street light 230V,50Hz complete all as specifed and directed.
Relaying of old serviceable under ground PVC/XLPELT cable any grade and any size in trenches/fixed to wall/pole/roof/laid in floor including necessary connections and thimbling complete all as specified and as directed. (Earth work, brick & sand cushioning shall be measured and paid for separately under appropriate item).
Re-laying only old bricks, locally available, sub class ‘B’ bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and as directed.
Taking down unserviceable street light bracket M & L new street light bracket made out of GI pipe light grade 40 mm bore approx length not less than 100 cm bent to shape including new clamps cutting ,welding ,drilling holes ,nut,bolts washers etc including two coat of aluminium paint over one coat complete all as specified and as directed.
Supply and fix in replacement of junction box made of inpact resistance plastic & heat resistant materials of size not less than 230x170x105mm, IP 66 protection, single left hinged door including provision of suitable terminal connector 16A capacity with MCB SP 6A and fixing to the surface/light pole with suitable sizes of clamps, nuts and bolts complete all as specifed and directed.
Opening /disconnecting the electrical connection of defective/burnt out underground LT cable of any size any core from main switch/DB/junction box / LT panel/ L T O/H line etc. Taking out the required length of cable from existing loop, cutting the defective portion of cable ,providing required thimbles/connectors at cable end and reconnecting the cable in previous location with existing main switch/DB/Junctionbox/LT panel/O/H line etc all as directed. Note:- (I) the cost of required earth work ie excavation,returning filling,relaying of sand/bricks and cost of drawing the required length from protection pipe ,breaking of required brick work/plaster/concrete and redoing the required cement work to match the existing surface is deemed to be included in quoted rates and nothing extra should be paid on this account.(ii)Additional cable/ protection pipe required at site shall be measured and paid seperatly.
Supply and fixing amp rating 240V, 5 to 32 Amp 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning all as specified and directed
S&F in replacement of Power Contractor 3Pole 25A (ML-2)AC-3 230V Volts,50Hz coil voltage rating 240 volts including taking down old UNSV power contractor complete all as specified and directed. Incl taking down
S&F in replacement of Power Contractor 3Pole 40A (ML-3) AC-3 230V Volts,50Hz coil voltage rating 240 volts including taking down old UNSV power contractor complete all as specified and directed.
Supply and fix in replacement of PVC insulated, PVC sheathed, 3 core multi stranded copper conductor of size 1.5 Sqmm for connecting to streetlight fitting passing through conduit fixed including taking down existing cable complete all as specified and as directed. Note:- Conduit and coduit accessories shall be measured paid separately under respective item of this schedule
Supply and fix in repalcement of medium duty non matalic PVC conduit of 20 mm bore including all fitting such as bends, elbow, coupler lock nut etc, fixed along pole with clamp for streetlight including taking down old PVC conduct of any type complet all as specified and directed.
M&L for supply, install, testing and commissioning to electrical system distribution board (outdoor top canopy type), suitable size, factory made, single door, cubical type, back door fixed type, fabricated out of 2 mm thick CRCA steel sheet, powder coated, weather/dust/vermin proof, IP 65 protection, suitably spaced totally enclosed in chamber, with provision to enter light inside the panel for light sensing timer, earthing arrangement, inbuilt locking arrangement with two locks with duplicate key duly and including connection of all incoming and outgoing cables using suitable size lugs and glands, danger notice board, panel to be mounted on PCC 1:2:4 pedestal complete all as specified and directed including comprising of following items :- a) MCB 4ole 63 amp, 415 volts 10 KA - 01 No. MCB SPN -02 ( 32 Amp) (b) power contactor of capacity 25 Amp, 3 pole, 415 volts, 50 Hz - 01 No. (c) Timer Switch (Analog sensor type) type suitable for single phase distribution System. (d) Indication lamp (R,Y,B) LED type with suitable MCB control for each indicator - set of three
S&F in repair LED flood light fitting energy efficient not less than not less than 120Watt LED with pressure die cast aluminium housing with toughened glass,IP-66 degree of protection, luminarie efficacy 100 lumen/watt, colour temperature (CCT) of 5700K with integral electronic driver, surge protection unit and incl provn suitable clamps/bolts, nuts and conneting flexible copper wire complete all as specified and directed . Make :- Havells JETAIRIS FLS100WLED757SYMLTG / BRLEP 120W LED V3/ PRAZE F 144L WH NB-A5 TG SD 120W (Note: Equivalent latest updated brand in Havells/wipro/Bajaj)
Taking down unsv submain wiring M&L for sub main wiring for two single core PVC insulated cable 2.5 sqmm nominal cross sectional area stranded copper conductor and one single core green PVC insulated 2.5 sqmm stranded copper conductor earth continuity cable drawn through non metallic rigid PVC conduit not less than 20 mm dia including all conduit and fixing accessories, concealed in wall including cutting chases and making good disturbed surface to match complete all as specifed and directed Note: Two runs of cable, one run of earth continuity conductor and one run of PVC conduit shall be measured as unit length.
M&L for taking down unserviceable HPSV/MH light any type any hight removing from exisitng bldg/pole complete all as specified and directed.
EASHWAR ELECTRICALS
D Subramani and Sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .