Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.4 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹35.5 L+₹70,033 (2.01%)Rejected-Finance | L2 | Rejected-Finance Higher bid value | |
| 3 | L3₹36.6 L+₹1.8 L (5.12%)Rejected-Finance P O WEST SRIPURIA DIST TINSUKIA ASSAM PIN 786 145 | TINSUKIA | ASSAM | 786145 | L3 | Rejected-Finance Higher bid value | |
| 4 | L4₹37.2 L+₹2.4 L (7.02%)Rejected-Finance | L4 | Rejected-Finance Higher bid value | |
| 5 | L5₹37.8 L+₹3.0 L (8.56%)Rejected-Finance | L5 | Rejected-Finance Higher bid value |
Tender Value
₹32.6 L
EMD Value
₹65,200
Closing Date
10 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE DINJAN
GE DINJAN, PANITOLA (PO), DIBRUGARH (DIST), ASSAM
PROVN OF GD ROOM WITH TOILET AND BATHROOM NEAR GATE No 1 OF HQ 73 Mtn Bde CAMP AT LAIPULI AND SPL REPAIRS TO CONVERSION OF CONVENTIONAL TYPE SECURITY LT FITTING IN TO LED LT FITTING AT LAIPULI/FSD/DIBRUGARH INCLUDING CERTAIN MINOR WORK IN OUTPOCKET A
2021_MES_496547_1
C/8372/E8
Open Tender
Civil Works
Item Rate
180 days
DINJAN MIL STN
AS PER TENDER DOCUMENT
10 documents required · 10 mandatory
₹500
GE DINJAN
₹65,200
Yes
29 Jan 2022
21 Dec 2021
12 Jan 2022
21 Dec 2021
10 Jan 2022
4 Jan 2022
60 days
Amount
Surface dressing not exceeding 15 cm deep as in soft/loose soil complete all as specified and as directed.
Surface excavation averaging 15cm deep and not exceeding 30cm deep and getting out including removing the same to a distance not exceeding 50 metre, depositing as directed as in soft/loose soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, etc area not exceeding 10 Sqm on plan and getting out in soft/loose soil complete all as specified and as directed.
Excavation in trenches exceeding 1.5 m wide and not exceeding 3 m in depth for foundation, etc area not exceeding 10 Sqm on plan and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading in layers not exceeding 25cm, levelling, watering and well ramming as in soft/loose soil complete all as specified and as directed.
Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
M&L for plain cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in foundation, filling, sub base of floors and mass concrete, etc complete all as specified and as directed.
M&L for use and waste form work to sides of foundation, footings, bases of columns, plinth beams flat rough finished surfaces of concrete complete all as specified and as directed.
M&L for reinforced cement concrete M-25 (Design Mix) (using 20 mm graded stone aggregate) as in foundations including rafts, footings, plinth beams and mass concrete, etc complete all as specified and as directed. Note : Reinforcement will be measured and paid seperately.
M&L for use and waste formwork to sides of pillars, posts, struts, piers, columns and stanchions for flat rough finished surfaces of concrete complete all as specified and directed.
M&L for reinforced cement concrete M-25 (Design Mix) (using 20 mm graded stone aggregate) as in columns, pillars, posts and struts complete all as specified and as directed. Note : Reinforcement will be measured and paid seperately.
M&L for use and waste form work to soffits and sides lintel beam, roof beam for flat rough finished surfaces of concrete complete all as specified and as directed.
M& for reinforced cement concrete M-25 (Design Mix) (using 20 mm graded stone aggregate) as in beams, cantilevers, lintels over 1.5m span complete all as specified and as directed. Note : Reinforcement will be measured and paid seperately.
M&L for use and waste form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizonal or sloping) for flat rough finished surfaces of concrete complete all as specified and as directed.
M&L for reinforced cement concrete M-25 (Design Mix) (using 20 mm graded stone aggregate) as in chullah hoods; stairways (except spiral staircases) including steps (square or spandril), string pieces, carriages, etc., complete, any section straight or winding, but excluding landings, RCC water tanks upto 1500 litres complete all as specified and as directed.
M&L for use and waste formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide complete all as specified and as directed.
S F for TMT steel bars 10mm dia and over, cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
S&F for TMT steel bars 6mm dia., and over cut to length, bend to shape required, including cranking, bending spirally as in nibs, stirrups, spacers and binders binding with and including providing mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for plain cement concrete (1:2:4) type B-1, (using 20 mm graded stone aggregate) as in benching, coping, lintel upto 1.5m span cast in situ including necessary form work complete all as specified and as directed.
M&L for 40 mm thick damp proof course to horizontal or vertical surfaces including necessary form work in cement concrete(1:2:4) type B0 complete all as specified and as directed.
M&L for brick work using locally available first class bricks sub class 'B' bricks (old size brick), straight or curved on plan exceeding 6 m mean radius, built in cement mortar (1:4) complete all as specified and as directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:4) mixed with integral water proofing compound weight of cement as per manufacturer's instructions and finished the surface even and smooth without using extra cement complete all as specified and as directed. Note : WPC shall be measured and paid separately against respective item.
Supply only integral water proofing compound (ISI marked) complete all as specified and as directed. Make : Cico/Sika/Acco proof.
M&L for rendering 5 mm thick in cement mortar (1:3) on concrete surfaces as in ceilings (sunshed, chajja etc) and finishing surfaces even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 15 mm thick in cement mortar (1:6) on fair faces of brick masonry or concrete surfaces and finishing the surfaces even and fair without using extra cement complete all as specified and as directed.
M&L for preparing new surfaces of AC sheet/ceiling and applying three coats of white wash complete all as specified and as directed.
M&L for preparing new plastered surfaces of internal walls, etc and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and as directed.
M&L for preparation new external surfaces of wall, chajja, facia etc and applying two coats of water based acrylic weather proof exterior emulsion (exterior wall finish) paint over a coat of primer as per manufacturer's instruction complete all as specified and as directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
M&L for hardcore of gauge not exceeding 63 mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L for 75 mm thick, plain cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in sub-base of flooring, etc complete all as specified and as directed.
M&L for 100 mm thick, plain cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in sub-base of flooring, etc complete all as specified and as directed.
M&L for 40 mm thick, plain cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in floors & finishing the surfaces even and smooth with using extra cement complete all as specified and as directed.
S&F for 1.5 mm thick, 38mm wide aluminum dividing strips and inserted in position to conform to design complete all as specified and as directed.
M&L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc, including 15 mm thick screed bed in cement mortar (1:6) and set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and as directed.
M&L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in skirting, dado etc, including 10 mm thick screed bed in cement mortar (1:4) and set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and as directed.
M&L for glazed, ceramic, coloured tiles of size 350mm x 450mm x 7mm thick, on vertical surfaces such as skirting, dados etc, including 10 mm thick bedding in cement mortar (1:4) and set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and as directed.
M&L for granite stone slab (of any type) 18 to 20 mm thick, machine cut,as in cooking platform bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including 15 mm thick screed bed in cement mortar (1:6) and cutting, rounding to edge of slab, polishing complete all as specified and as directed.
M&L for 75 mm thick, plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in plinth protection etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand (1:2) complete all as specified and as directed.
S&F for pressed steel frames for doors local work shop made of size 125x60mm with one or more rebates using cold rolled commercial mild steel sheet of 1.2mm thick including providing and fixing necessary lugs, 100mm butt hinges, lock strike plate, shock absorber etc and including PCC filling of hollow section using Plain cement concrete (1:3:6) type C1 complete all as specified and as directed.
M&L for 35mm thick 2nd class hard wood plain, framed, panelled shutters (any number of panels), with panels of 12mm thick veneered particle board medium density with commercial face veneers: supplied and fitted to chowkats complete all as specified and as directed, Sizes/section of members of shutters shall be as specified in SSR Part I, Section -8, clause 8.24 (a).
M&L for 35 mm thick, second class hardwood glazed and skeleton shutters open rebated and prepared to receive glass, gauge, etc, divided in to squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded complete all as specified and as directed in SSR Part I Section 8 clause 8.24 (a).
S&F for solid PVC door frames of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and as directed.
S&F for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded, plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour 5mm thick PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, as per specification and drawing and as directed.
Cutting openings, through brick walls built in cement mortar for door, window and other openings or enlarging existing openings converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc.. to store and rubbish not exc. 50m complete all as specified and as directed.
S&F for mild steel small articles using flat iron of size 25x3mm thick such as band, strap, hold fast, cleat, support, hook, hinges, base tie for door frame etc and other similar items conforming to Fe-290 (Gde E-165) complete all as specified and as directed.
M&L for preparing surfaces of wood and wood based materials, new or old of any description and girth, not otherwise described and treated with two coats of creosote oil complete all as specified and as directed.
S&F for 100 mm size, butt hinges, medium weight, cold rolled mild steel complete all as specified and as directed.
S&F for 150mm long aluminium anodised tower bolts complete all as specified and as directed.
S&F for 125 mm size, aluminium handles, cast type, anodised to a bright natural, mat finish complete all as specified and as directed.
S&F for aluminium alloy anodised sliding door bolt with hasp and staple (bolt type) and fixing clipes of sheet, cast or extruded sections and fixing bolts of extruded sections or cast aluminium alloy, length of bolt of 250 mm complete all as specified and as directed.
S&F for 5.5 mm thick, sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
S&F for galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanised wire staples complete all as specified and as directed.
M&L for mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bar, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe-290 (Gde E-165) complete all as specified and as directed.
M&L for preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
S&F for 500 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) as per IS 12701:1996, hoisted and fixed in position including provision of 20/15mm bore medium grade pipe for connecting inlet, outlet, overflow and washout pipe all as specified in SSR Part I and as directed.
S&F for 20 mm bore, ball valves high pressure of PTMT with epoxy coated Aluminium rod and high density plastic ball screwed for iron pipe and fixed. (Minimum weight - 210 gms) complete all as specified and as directed.
S&F for 15 mm bore, stop valves, cast copper alloy, fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed.
Supply, laying, connection and testing, 15mm bore, steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and as directed.
Supply, laying, connection and testing, 20mm bore, steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and as directed.
S&F for 15 mm bore, bib taps, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed.
S&F for vitreous china wash basin, size 550 x 400mm, white, flat back, with PVC waste pipe, CP waste coupling, chain, plug and porcelean stopper and brackets including cutting for and pinning in ends of brackets but excluding tap complete all as specified and as directed. Make : Cat No C0406 of Parryware/Hindware/Cera.
S&F for 15 mm bore, pillar taps, fancy type, cast copper alloy, chromium plated with capstan heads, screwed down high pressure with or without lettered 'Hot or Cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed.
S&F for vitreous china bowl urinal flat back, of size 465x355x265mm, white (minimum) with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) including providing and fixing plugs, bedding urinal against wall in cement mortar (1:2) securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement complete all as specified and as directed.
S&F for 15mm bore, PVC connection pipe 600mm long with PTMT nuts at both ends complete all as specified and as directed.
S&F for swival shower of PTMT 15mm bore (minimum weight 40 gms) including shower arm 15mm size, 195mm long with bend of 45 degree with flange of PTMT any colour (minimum wt 40 gms) complete all as specified and as directed.
S&F for towel rail, 600mm long of PTMT fixed with and including chromium plated brass screws and wooden / plastic cleats (Minimum weight 190gms) complete all as specified and as directed.
S&F for vitreous china squatting pan, 'Orissa' pattern, size 580 x 440 mm white with integral foot rest and 'P' or 'S' trap, including provision of lime concrete bedding, connection to trap and flushing pipe providing 110mm PVC WC connector etc complete including making good to disturbed surfaces of floor to match with existing specifications complete all as specified and as directed. Make : Cat No- C0117 of Parryware/ Hindware/ Cera.
S&F for 10 litre capacity, PVC valve less syphonic action type, flushing cistern, low level, white, with inlet, ball valve, flush pipe, float and handle including brackets complete all as specified and as directed.
S&F for 110 mm bore, UPVC (SWR), Type 'B', Soil waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors, etc complete all as specified and as directed.
S&F for 110 mm bore, PVC (SWR) bends of any radius complete all as specified and as directed.
S&F for 75 mm dia outlet , PVC (SWR) floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and as directed.
M&L for forming V grooves in plaster not exceeding 10mm deep and not exceeding 10mm on face complete all as specified and as directed.
M&L for water proofing treatment on RCC roof etc. comprising with the following operation and as specified herein below and as directed:- (a) Taking down existing old tarfelt, bituminous compound including cleaning and removing debris to a distance exceeding 100m and not exceeding 250m. (b) 15 mm thick plastering in cement mortar (1:4) finished even and smooth. (c) Preparing and cleaning of fully dried cement plastered surface. (d) Applying one coat of cold bituminous primer to the plastered surface @ 0.25 liters per sqm conforming IS-3384 (e) A layer of APP based polymeric membrane membrane 3mm thick (minimum) weighing 3.5 kg per sqm reinforced with polyster non woven fabric (weighing not less than 160 gms/sqm )shall be applied over bituminous primer as specified above. Application of polymeric membrane shall be by torch application. The over lap shall be minimum 100 mm on transverse direction and 75 mm in longitudinal direction. (f) One coat of aluminium paint over the APP based membrane @ 0.11 Kg/Sqm
M&L for concealed point wiring with 1.5 Sqmm (nominal area), FR PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including PVC conduit with all fittings and accessories of PVC conduit (like Tee, bend etc.) complete with and including 1.5 Sqmm (nominal area) FR PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point terminated in metal flush box of suitable size for mounting switches, sockets, regulators etc including cutting chases and making good by using cement mortar (1:4) complete for one light/fan/bell/buzzer point controlled by one ,one way switches complete all as specified and as directed.
All as per item No 77 above but for one 3 pin socket outlet, 5/6 Amps on Independent board complete all as specified and as directed.
All as per item No 77 above but for one 5/6 Amps, 3/5 pin socket outlet on the same board with other switches complete all as specified and as directed.
All as per item No. 77 above but wiring with cables of size 2.5 sqmm and cables of size 2.5 sqmm as continuous earth wire for one 6/16 Amps switch socket combination on Independent board complete all as specified and as directed.
S&F for switch piano, 5/6 Amp single pole, flush type one way 230 volts bearing ISI marked complete all as specified and as directed.
S&F for socket outlet, 2 in 1, 3 pin, 5/6 Amps, flush type bearing ISI marked complete all as specified and as directed.
S&F for switch socket combination, 2 in 1, 5/6 Amps, flush type, 240 volts bearing ISI marked complete all as specified and as directed.
S&F for switch socket combination, 2 in 1, 6/16 Amps, 240 volts, bearing ISI marked flush type complete all as specified and as directed.
S&F for ceiling rose, 3 phase/PVC/polycarbonate, isolated body bearing ISI marked and including PVC box complete all as specified and as directed.
S&F for stepped type(five steps) electronic fan regulator flush type complete all as specified and directed. Make: Model No. 14502 of Anchor/ Havells/Crompton greaves.
Supply, installing, testing and commissioning of BLDC ceilling fan, BEE 5 stars rated, 230 V, 50Hz, 1200 mm sweep, colour Opal white, power input 28 Watt, speed 370 RPM, 3 nos. blades, copper winding, Power factor not less 0.9, Air delivery minimum 215 CMM, including all fixing accessories and insulation resistance more than 2 mega ohm complete all as specified and as directed. Make : Crompton/ Philips/Bajaj.
Supply, installing, testing and commissioning of exhaust fan, suitable for Single Phase AC supply, earthing etc, 220/240 V, 300 mm sweep size, fan speed 950 RPM, 4 nos. blades, copper winding, Air delivery minimum 6500 CMM and including all fixing accessories complete all as specified and as directed. Make : Crompton/Bajaj as approved.
S&F for lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
S&F for LED Lamp 9 Watt complete all as specified and as directed. Make : Havells /Philips/Bajaj /Surya.
S&F for 18 Watt surface and wall mounting type LED batten with polycarbonate housing and integrated complete all as specified and as directed. Make : Havells/Philips/Bajaj/CG/Wipro.
S&F for factory made board distribution (DB) Double Door in sheet steel enclosure with common bus bar at incomming end, SPN, 8 way, 240 Volts suitable for housing 200 Amp MCBs complete all as specified and as directed.
S&F for factory made board distribution (DB) Double Door in sheet steel enclosure with common bus bar at incomming end, SPN, 4 way, 240 Volts suitable for housing 200 Amp MCBs complete all as specified and as directed.
S&F for MCB, SPN, 240 Volts, 5 to 32 Amps, 'C' Series, 10KA capacity complete all as specified and as directed. Make : Cat No. 408609 to 408617 of Legrand / L&T/ Havells.
S&F for MCB, 'C' Series, SP, 240 Volts, 5 to 32 Amps, 'C' Series, 10KA capacity complete all as specified and as directed. Make : Cat No. 408587 to 408595 of Legrand /L&T/ Havells.
S&F for MCB, 'C' Series, TPN, 240 Volts, 5 to 32 Amps, 'C' Series, 10KA capacity complete all as specified and as directed. Make : HPL/L&T/Havells.
M&L for sub main wiring with two run of 6 Sqmm (Nominal area) single core cable PVC insulated, multistranded, unsheathed, copper conductor cables (HRFR), 1100 Volts grade drawn through PVC casing-caping of suitable size, fixed to wall/ceiling etc including one run of 6 Sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor (HRFR) as earth wire and duly connected to common earth point complete all as specified and as directed by Engineer-in-charge. Note : (a) one run PVC Casing-caping, two run wiring cables and one run of earth wire will be measured as one length (b) All incoming and outgoing cable shall be connected by using proper lugs and sockets.
S&F for 10W, LED Energy saving new generation bulk head luminaire with opal diffuser including lamp and connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed. Make : Cat part no: LHEOAOP7UZ6W010 of Havells/Philips/Bajaj/HPL.
S&F for 25 Watt LED building security light new generation energy saving and environtal friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embeded PC cover having TOP OPENING separate driver compartment with IP65 protection and impact resistance of IK07 complete as specified and as directed. Make : Havells/Philips/Bajaj/CG/Wipro.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting exceeding 10 cm but not exceeding 20 cm girth complete all as specified and as directed.
M&L for earthing complete with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers protected by 15mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC (1:2:4) type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers,necessary earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I complete all as specified and as directed.
Taking down LED/CFL/sodium vapour/metal halide/MV lamp street light/flood light/ any other light fitting of any make and size including GI bracket at any height and refixing the same in position after replacement of unserviceable/defective parts like fittings , lamps , LED driver etc as required to make the fittings in smooth serviceable condition and testing complete and as directed. Note : (i) Replacement of unserviceable parts shall be measured and paid seperately as "supply only" (ii) Replacement of worn out cables as per existing size and type of the fitting shall be deemed to be included in the unit quoted rate of this item. (iii) Necessary climbing arrangements like scaffolding for repairing/ removing/ refixing the fittings should be included in the quoted rate.
S&F for LED street lights nominal power 100 watts, LEDs wattage of min 1 watt and max of 3 watt each, operational volt 170 volts to 270 v, frequency of 50 Hz, lumen efficacy of min 100 lumens per watts, built in integrated electronic LED driver (SMPS based constant current supply) output open/ short circuit protection, phase to phase protection, over voltage protection, surge voltage protection not less than 5 kV with external SPD, protection grade IP 66, CRI greated than 70 %, CW available CCT of 5700 K, powerfactor of min 0.95, pressure die-cast aluminium alloy housing with polyster powder coated, life span of minimum 50000 working hours including fixing at any height and including wiring using three core single run PVC insulated , pvc sheathed flexible copper conductor FR-LSH cables suitable for outdoor use 1.5 sqmm as per IS 694:2010 complete all as specified and as directed. Make : Havells/Crompton/Century/Bajaj/Phillips.
S&F for LED street lights nominal power 90 watts, LEDs wattage of min 1 watt and max of 3 watt each, operational volt 170 volts to 270 v, frequency of 50 Hz, lumen efficacy of min 100 lumens per watts, built in integrated electronic LED driver (SMPS based constant current supply) output open/ short circuit protection, phase to phase protection, over voltage protection, surge voltage protection not less than 5 kV with external SPD, protection grade IP 66, CRI greated than 70 %, CW available CCT of 5700 K, powerfactor of min 0.95, pressure die-cast aluminium alloy housing with polyster powder coated, life span of minimum 50000 working hours including fixing at any height and including wiring using three core single run PVC insulated , pvc sheathed flexible copper conductor FR-LSH cables suitable for outdoor use 1.5 sqmm as per IS 694:2010 complete all as specified and as directed. Make : Havells/Crompton/Century/Bajaj/Phillips.
S&F for LED street lights nominal power 70/75 watts, LEDs wattage of min 1 watt and max of 3 watt each, operational volt 170 volts to 270 v, frequency of 50 Hz, lumen efficacy of min 100 lumens per watts, built in integrated electronic LED driver (SMPS based constant current supply) output open/ short circuit protection, phase to phase protection, over voltage protection, surge voltage protection not less than 5 kV with external SPD, protection grade IP 66, CRI greated than 70 %, CW available CCT of 5700 K, powerfactor of min 0.95, pressure die-cast aluminium alloy housing with polyster powder coated, life span of minimum 50000 working hours including fixing at any height and including wiring using three core single run PVC insulated , pvc sheathed flexible copper conductor FR-LSH cables suitable for outdoor use 1.5 sqmm as per IS 694:2010 complete all as specified and as directed. Make : Havells/Crompton/Century/Bajaj/Phillips.
S&F for LED street lights nominal power 60 watts, LEDs wattage of min 1 watt and max of 3 watt each, operational volt 170 volts to 270 v, frequency of 50 Hz, lumen efficacy of min 100 lumens per watts, built in integrated electronic LED driver (SMPS based constant current supply) output open/ short circuit protection, phase to phase protection, over voltage protection, surge voltage protection not less than 5 kV with external SPD, protection grade IP 66, CRI greated than 70 %, CW available CCT of 5700 K, powerfactor of min 0.95, pressure die-cast aluminium alloy housing with polyster powder coated, life span of minimum 50000 working hours including fixing at any height and including wiring using three core single run PVC insulated , pvc sheathed flexible copper conductor FR-LSH cables suitable for outdoor use 1.5 sqmm as per IS 694:2010 complete all as specified and as directed. Make : Havells/Crompton/Century/Bajaj/Phillips.
S&F for LED street lights nominal power 45 watts, LEDs wattage of min 1 watt and max of 3 watt each, operational volt 170 volts to 270 v, frequency of 50 Hz, lumen efficacy of min 100 lumens per watts, built in integrated electronic LED driver (SMPS based constant current supply) output open/ short circuit protection, phase to phase protection, over voltage protection, surge voltage protection not less than 5 kV with external SPD, protection grade IP 66, CRI greated than 70 %, CW available CCT of 5700 K, powerfactor of min 0.95, pressure die-cast aluminium alloy housing with polyster powder coated, life span of minimum 50000 working hours including fixing at any height and including wiring using three core single run PVC insulated , pvc sheathed flexible copper conductor FR-LSH cables suitable for outdoor use 1.5 sqmm as per IS 694:2010 complete all as specified and as directed. Make : Havells/Crompton/Century/Bajaj/Phillips.
S&F for LED flood light nominal power 200 watts , LEDs wattage of min 1 watt and max of 3 watt each, operational volt 170 volts to 270 v, frequency of 50 Hz, lumen efficacy of min 100 lumens per watts, built in integrated electronic LED driver (SMPS based constant current supply) with lower THD, output open/ short circuit protection, phase to phase protection, over voltage protection, surge voltage protection not less than 5 kV with external SPD, protection grade IP 66, CRI greated than 70 %, beam angle of 50 degree clear, THD below or less than 10%, CW available CCT of 5700 K +/- 300K, powerfactor of min 0.95, pressure die-cast aluminium alloy housing with polyster powder coated, life span of minimum 50000 working hours including fixing at any height of bldg/pole with MS flat iron clamps of size 40 x 6mm and connected nuts and bolts and including wiring using three core single run PVC insulated , pvc sheathed flexible copper conductor FR-LSH cables suitable for outdoor use 1.5 sqmm as per IS 694:2010 complete all as specified and as directed. Make : Havells/Crompton/Century/Bajaj/Phillips.
S&F for LED flood light nominal power 100 watts , LEDs wattage of min 1 watt and max of 3 watt each, operational volt 170 volts to 270 v, frequency of 50 Hz, lumen efficacy of min 100 lumens per watts, built in integrated electronic LED driver (SMPS based constant current supply) with lower THD, output open/ short circuit protection, phase to phase protection, over voltage protection, surge voltage protection not less than 5 kV with external SPD, protection grade IP 66, CRI greated than 70 %, beam angle of 120 degree clear, THD below or less than 10%, CW available CCT of 5700 K +/- 300K, powerfactor of min 0.95, pressure die-cast aluminium alloy housing with polyster powder coated, life span of minimum 50000 working hours including fixing at any height of bldg/pole with MS flat iron clamps of size 40 x 6mm and connected nuts and bolts and including wiring using three core single run PVC insulated , pvc sheathed flexible copper conductor FR-LSH cables suitable for outdoor use 1.5 sqmm as per IS 694:2010 complete all as specified and as directed. Make : Havells/Crompton/Century/Bajaj/Phillips.
S&F for LED flood light nominal power 70 watts , LEDs wattage of min 1 watt and max of 3 watt each, operational volt 170 volts to 270 v, frequency of 50 Hz, lumen efficacy of min 100 lumens per watts, built in integrated electronic LED driver (SMPS based constant current supply) with lower THD, output open/ short circuit protection, phase to phase protection, over voltage protection, surge voltage protection not less than 5 kV with external SPD, protection grade IP 66, CRI greated than 70 %, beam angle of 120 degree clear, THD below or less than 10%, CW available CCT of 5700 K +/- 300K, powerfactor of min 0.95, pressure die-cast aluminium alloy housing with polyster powder coated, life span of minimum 50000 working hours including fixing at any height of bldg/pole with MS flat iron clamps of size 40 x 6mm and connected nuts and bolts and including wiring using three core single run PVC insulated , pvc sheathed flexible copper conductor FR-LSH cables suitable for outdoor use 1.5 sqmm as per IS 694:2010 complete all as specified and as directed. Make : Havells/Crompton/Century/Bajaj/Phillips.
Taking out/down old/unserviceable under ground LT cables of any size and connections including pipes etc from trenches/walls/poles of any cross sectional area and keeping serviceable materials in safe custody for reuse and unserviceable materials removing from site complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items of this schedule. (2) Excvation and earth work shall be measured and paid seperately.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, armoured, 4 core, nominal cross sectional area of main conductor 10 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI Pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items of this schedule. (2) Excvation and earth work shall be measured and paid seperately.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, armoured, 2 core, nominal cross sectional area of main conductor 10 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI Pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items of this schedule. (2) Excvation and earth work shall be measured and paid seperately.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, armoured, 2 core, nominal cross sectional area of main conductor 6 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI Pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items of this schedule. (2) Excvation and earth work shall be measured and paid seperately.
M&L for sand cushioning with dry clean sand 15cm below cable and 8cm above the cable complete all as specified and as directed. Note : Punned thickness shall be measured for payments.
M&L for bricks laid in trenches for LT cable protection with length of brick perpendicular to length of cable complete all as specified and as directed.
Boring of holes horizontall for laying not less than 40mm pipe (minimum depth 0.75 mtr from top level) under the road pavement, hardstanding using trenchless technology complete all as directed. Note: Cost of accessories required for making hole/bore deemed to be included in the quoted rate.
M&L for 40 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor/road crossing/drain etc as in UG cable protection complete to walls and ceilings or laid in floors complete all as specified and as directed.
S&F for 25 mm dia, rigid non metalic, PVC conduits medium grade complete with all accessories suitable for UG cable laid in trenches complete all as specified and as directed.
S&F in repairs modular junction box made of SMC/FRP of size 250x250x155mm with provision of MCB SP, and connector terminal 4 pole indicating RYB phase colour and neutral colour complete fixed to street light pole with suitable size of mild steel clamps, nuts and bolts complete all as specified and as directed. Make : Cat No. GSJB 2525 of Sintex / Hensel.
S&F in repairs LED post top lantern of 40/45 Watt made in cast aluminium spigot housing with decorative opal acrylic diffuser and IP65 protection, including 40 Watt MH/SV lamp including providing and connection with 1.5Sqmm copper conductor, multistranded copper conductor cable of required length complete all as specified and as directed. Make : Model - APBY040C0875 of Century/Havells/ Philips/CG/cromption.
S&F in repairs decorative gate light 20W made up of high grade unbreakable polycarbonate material suitable for retrofit LED lamp B22 Base, including providing and connection with 2.5 Sqmm aluminium conductor, cable of required length and taking down old unserviceable fitting of any make and size complete all as specified and as directed. Make : Havells /Philips/Bajaj/Wipro/crompton/Century.
S&F for service connection cable, 1100 volts grade heavy duty, PVC insulated aluminium conductor, stranded of size 10 Sqmm x 4 core, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm dia GI suspension wire, one twin core cable flat or circular etc complete all as specified and as directed.
S&F for twin core twisted, PVC insulated and sheathed, multi stranded aluminium conductor cable 2.5 Sqmm cable to connect from junction to box etc complete all as specified and as directed.
Dismantling/uprooting of LT unserviceable pre-stressed concrete/steel poles of any size and shape and including taking out dismantled portion of poles embeded in ground after necessary demolition of concrete foundation and making good disturbed ground surface properly and disposal thereof complete all as specified and as directed. Note : Earth work for taking out poles shall be measured and paid separately under relevant item of this schedule.
M&L for steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) including two coats of aluminium paint over a coat of primer except the planting depth which shall be painted with black bituminous paint including writing pole number using suitable paint complete all as specified and as directed. Note : Excavation and earth work, PCC filling shall be measured and paid separately.
S&F in repairs street light bracket arm of length not less than 1.2 m made out of galvansied iron tubing 32mm bore, light grade to pole, etc with suitable size flat iron clamp, nuts, bolts including painting with two coats of aluminium paint over a coat of red oxide primer zinc chrome in MS clamp complete all as specified and as directed.
S&F in repairs street light bracket arm of length not less than 1.2 m made out of galvansied iron tubing 25mm bore, light grade to pole, etc with suitable size flat iron clamp, nuts, bolts including painting with two coats of aluminium paint over a coat of red oxide primer zinc chrome in MS clamp complete all as specified and as directed.
S&F for GI clamp made with GI strip of size 32x6mm Fe-290 (Gde E-165) for support of cable protection pipe from existing steel/RCC pole of any size by making holes to strip and fixing with nuts, bolts and washer of suitable size complete all as specified and as directed.
S&F for time switches digital type 415 Volt Three phase of 20 Amp rating with contactor fitted inside and MCB TPN 20 Amp, max load of 6 KW within steel enclosure complete including connecting items complete all as specified and as directed. Make : Havells / Philips/ L&T.
M&L for preparation of old painted surface and removing dust and other deposited material by scraping from LT PSC/steel tubular poles of upto 11.00 metre long, cross arms brackets and applying two coats of aluminium paint to all steel surfaces, including MS clamps, cable protection pipe, bracket fitted with street light fittings etc and one coat of cement based paint to PSC pole including Zebra colour of painting upto 2.1 m height from the top of coping/bottom of pole as per site condition and numbering of poles complete all as specified and as directed. Note : Zebra colour will be applied by synthetic enamel paint of black/yellow colour as approved in alternate layer of 30 cm height of each layer.
M H KHAN
M/S BORAH BROTHERS
FREEZCON
M/S AUTOMOTIVE WORLD
M/s GANDHESWAR PHUKAN
M/S CHANDAN ENTERPRISE
NChetia and Sons Trading
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .