Tender Value
₹11.3 L
EMD Value
₹22,700
Closing Date
25 Nov 2022, 4:00 pmClosed
Executive Engineer ED-II JPDCL Jammu
Office of the Executive Engineer ED-II JPDCL Jammu
Supply, Erection, Testing and Commissioning of 3Ph4W LT line at Upper Gadigarh, Vishal Colony Babliana, Bishnah, Chakra Bishnah, Shifting of 100KVA at Arnia under Capex Budget 2022-23.
2022_PDD_192531_1
E-Nit 54 of 2022 dated 13-10-2022
Open Tender
Electrical Works
Turn-key
45 days
Within Jurisdiction of the XEN ED- II JPDCL Jammu
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Executive Engineer ED II JPDCL Jammu
₹22,700
3 Dec 2022
17 Oct 2022
26 Nov 2022
17 Oct 2022
25 Nov 2022
17 Oct 2022
17 Oct 2022 - 25 Oct 2022
Amount
Laying of 0.500 Km LT line on 8Mtr PCC poles using ACSR Rabbit Conductor at Upper Gadigarh C/o Sh. Sham Lal Gupta Scheme Code PDDSS2021100730
Supply, Transportation, Erection of 8 Mtr Long PCC Pole (WL-200 KG) including excavation of pit and back filling of soil & consolidating by ramming, watering etc.
Providing & Fixing of MS U-Clamp duly painted with two coats od Red Oxide and Al Paint with Shackle Insulator (Porcelain) along with Nut & Bolt of sorts
Supply, Laying & Stringing of ACSR Rabbit Conductor through insulators including proper binding & twisting with soft Aluminium Wire
Providing & Fixing of Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid Stay Rod & 7/3.15 mm dia stranded wire complete
Providing & Fixing of Danger Plates with Clamps
Providing & Fixing of Anti Climbing device with Clamps
Providing & Fixing of LT Line Spacers
Providing of Earthing Complete by GI Coil ----Nominal diameter of the G.I Wire 4mm, No. of closely bound turns 115, External Dia of the coil 50mm, Length of Coil 460mm, Free length of GI Wire at one end of coil 2500mm, Total Weight of Coil 1.850Kg.
Providing of Stone Pad 300 mmx300mmx75mm
Providing and fixing of Aluminium sleeves
Supply Installation Testing Commissioning of 0.500Km 11KV using 50mm² AB Cable on 9 Mtr PCC Poles Vishal Colony Babliana C/o Surjeet Singh Scheme Code PDDSS2021100740
Supply, Erection, Testing & Commissioning of 9 Mtr Long PCC Pole (WL-300Kg) including Transportation to erection site, excavation of pit and back filling of soil & consolidating by ramming, watering etc.
Supply, Erection, Testing & Commissioning of 50 mm² AB (HT) Cable (3x50 + 1x35 mm²)
Supply, Erection, Testing & Commissioning of Heat Shrinkable Outdoor Cable Termination Kit
Supply, Erection, Testing & Commissioning of Suspension/Tension Clamp with eye hook
Supply & fixing of Galvinized Nuts and Bolts.
Supply & fixing of Danger Plates
Supply & fixing of Anti-Climbing Device with Clamps
Supply & installation of Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
Provinding of Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole
Supply, Erection, Testing & Commissioning of Mid Span Straight Throgh Jointing Kit for 11 KV ABC
Supply & installation of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm Dia GI stranded wire complete.
Laying of 0.200 Km LT line on 8Mtr PCC poles using ACSR Rabbit Conductor at Bishnah C/o Sh. Omkar Nath Scheme Code PDDSS2021100731
Supply, Transportation, Erection of 8 Mtr Long PCC Pole (WL-200 KG) including excavation of pit and back filling of soil & consolidating by ramming, watering etc.
Providing & Fixing of MS U-Clamp duly painted with two coats od Red Oxide and Al Paint with Shackle Insulator (Porcelain) along with Nut & Bolt of sorts
Supply, Laying & Stringing of ACSR Rabbit Conductor through insulators including proper binding & twisting with soft Aluminium Wire
Providing & Fixing of Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid Stay Rod & 7/3.15 mm dia stranded wire complete
Providing & Fixing of Danger Plates with Clamps
Providing & Fixing of Anti Climbing device with Clamps
Providing & Fixing of LT Line Spacers
Providing of Earthing Complete by GI Coil ----Nominal diameter of the G.I Wire 4mm, No. of closely bound turns 115, External Dia of the coil 50mm, Length of Coil 460mm, Free length of GI Wire at one end of coil 2500mm, Total Weight of Coil 1.850Kg.
Providing of Stone Pad 300 mmx300mmx75mm
Providing and fixing of Aluminium sleeves
Laying of 0.250 Km LT line on 8Mtr PCC poles using ACSR Rabbit Conductor at Village Chakra Bishnah C/o Manohar Lal Scheme Code PDDSS2021100736
Supply, Transportation, Erection of 8 Mtr Long PCC Pole (WL-200 KG) including excavation of pit and back filling of soil & consolidating by ramming, watering etc.
Providing & Fixing of MS U-Clamp duly painted with two coats od Red Oxide and Al Paint with Shackle Insulator (Porcelain) along with Nut & Bolt of sorts
Supply, Laying & Stringing of ACSR Rabbit Conductor through insulators including proper binding & twisting with soft Aluminium Wire
Providing & Fixing of Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid Stay Rod & 7/3.15 mm dia stranded wire complete
Providing & Fixing of Danger Plates with Clamps
Providing & Fixing of Anti Climbing device with Clamps
Providing & Fixing of LT Line Spacers
Providing of Earthing Complete by GI Coil ----Nominal diameter of the G.I Wire 4mm, No. of closely bound turns 115, External Dia of the coil 50mm, Length of Coil 460mm, Free length of GI Wire at one end of coil 2500mm, Total Weight of Coil 1.850Kg.
Providing of Stone Pad 300 mmx300mmx75mm
Providing and fixing of Aluminium sleeves
Erection of 0.150Km 11KV line with ACSR Weasel Conductor on 9 Mtrs PCC poles at Arnia C/o Sukhdev Singh Scheme Code PDDSS2021100741
Supply, Erection, Testing & Commissioning of 9 Mtr Long PCC Pole (WL-300Kg) including Transportation to erection site, excavation of pit and back filling of soil & consolidating by ramming, watering etc.
Supply, Transportation, Fabrication & Fixing of MS Channel Iron, Cross arms, Angle Iron Braces, Clamps etc duly fabricated, red oxide & aluminium paint coated including all necessary Nut & Bolts & Washers etc.
Supply, Laying & Stringing of ACSR Weasel Conductor on Cross arms through insulators including proper binding & twisting with soft Aluminium Wire
Providing & Fixing of PG Clamps for 30mm² ACSR Conductor.
Providing & Fixing of 11kV Polymeric composite Pin Insulator 12kV, 10kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm.
Providing & Fixing of 11kV Polymeric composite Disc Insulator with fitting 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing & Fixing of Galvanized Nuts and Bolts
Providing & Fixing of Danger Plates with Clamps
Providing & Fixing of Anti-Climbing Device with Clamps
Providing of Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
Providing & Fixing of Stone Pad (300 mm x 300 mm x 75 mm)
Providing & Fixing of Aluminium Jointing Sleeves
Providing & installation of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Laying of 0.200 Km LT line on 8Mtr PCC poles using ACSR Rabbit Conductor at Arnia C/o Sukhdev Singh Scheme Code PDDSS2021100741
Supply, Transportation, Erection of 8 Mtr Long PCC Pole (WL-200 KG) including excavation of pit and back filling of soil & consolidating by ramming, watering etc.
Providing & Fixing of MS U-Clamp duly painted with two coats od Red Oxide and Al Paint with Shackle Insulator (Porcelain) along with Nut & Bolt of sorts
Supply, Laying & Stringing of ACSR Rabbit Conductor through insulators including proper binding & twisting with soft Aluminium Wire
Providing & Fixing of Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid Stay Rod & 7/3.15 mm dia stranded wire complete
Providing & Fixing of Danger Plates with Clamps
Providing & Fixing of Anti Climbing device with Clamps
Providing & Fixing of LT Line Spacers
Providing of Earthing Complete by GI Coil ----Nominal diameter of the G.I Wire 4mm, No. of closely bound turns 115, External Dia of the coil 50mm, Length of Coil 460mm, Free length of GI Wire at one end of coil 2500mm, Total Weight of Coil 1.850Kg.
Providing of Stone Pad 300 mmx300mmx75mm
Providing and fixing of Aluminium sleeves
Dismantling of 11/0.433kV, 100KVA, 3-phase Distribution Substation at Arnia C/o Sukhdev Singh Scheme Code PDDSS2021100741
Dismantling of 11/0.433kV, 100KVA , 3-phase Distribution Transformers
Dismantling of 9 Mtr Long ST/PCC Pole
Dismantling of MS Channel Iron, Cross arms, Angle Iron Braces, Clamps etc
Dismantling of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp
Dismantling of 11 kV Horn Gap Fuse Set 3 Phase 200A
Dismantling of Gapless Surge Arrestor,9 kV ,10 kA, LA
Dismantling of PVC Cable 185 mm² alongwith 12 Nos Al. Thimble of 185 mm²
Dismantling of LT Distribution Box for 100kVA DTR
Dismantling of 11kV Polymeric composite Pin Insulator
Dismantling of 11kV Polymeric composite Disc Insulator
Write back of all dismantled material except 100KVA Transformer
Re-Erection of Dismantled 11/0.433kV, 100KVA, 3-phase Distribution Substation at Arnia C/o Sukhdev Singh Scheme Code PDDSS2021100741
Re-Erection of dismantled 11/0.433kV, 100KVA , 3-phase Distribution Transformers
Supply, Transportation, Erection of 9 Mtr Long ST Pole (ST-410 SP33) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. Including painting with two coats of Red Oxide and Al. Paint for smooth surface.
Supply, Transportation, Fabrication & Fixing of MS Channel Iron, Cross arms, Angle Iron Braces, Clamps etc duly fabricated, red oxide & aluminium paint coated including all necessary Nut & Bolts & Washers etc.
Supply, Installation, Testing & Commissioning of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
Supply, Installation, Testing & Commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A
Supply & Fixing of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
Providing & Fixing of PVC Cable 185 mm² alongwith 12 Nos Al. Thimble of 185 mm²
Providing & Fixing of LT Distribution Box for 100kVA DTR with 160A MCCB for incomer & SFU's for Outgoing Circuits
Providing of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Providing of Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole
Providing & Fixing of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing & Fixing of 11kV Polymeric composite Disc Insulator 12kV with Fitting ,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Wedge Connectors / PG Clamps
Providing & Fixing of Anti Climbing device with Clamps
Providing & Fixing of Danger Plates with Clamps
Providing & Fixing of Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid Stay Rod & 7/3.15 mm dia stranded wire complete
NATIONAL ENGINEERING PROJECTS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .