| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.3 LAccepted-AOC FLAT NO 20 AMBEDKAR ROAD DEHU ROAD PUNE 412101 D 101 CESC INDEX NO D 101 HQ CESC PUNE | NA | NA | 412101 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹27.4 L+₹4.8 L (21.1%)Rejected-Finance | L2 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | Santhi Enterprises L1 | M/s.TIRUPATI BUILDERS L2 |
|---|---|---|---|---|---|
| 1.00 | Taking down Chowkhats or frames exc 1.5 sq. m but n exc 4 sq. m each but with shutters (without taking off shutters from the frame)
Note : Rate is inlcusive of forming jamb post removal of chowkhat or frame. | 10 | Each | 148 ₹1,480 | 120 ₹1,200 Lowest |
| 2.00 | Taking down Shutters of any description exc 1 sq. m and n.exc 2sqm each | 10 | Each | 98 ₹980 | 70 ₹700 Lowest |
| 3.00 | Material and Labour for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/ Chowkhat of size 65x 125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). | 50 | RM | 890 ₹44,500 | 850 ₹42,500 Lowest |
| 4.00 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter/ skeletal shutter of size 35mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer In- Charge. (Note: stainless steel butt hinges and necessary S.S screws, SS Wiremesh shall be paid separately) | 33.93 | Sqm | 5,100 ₹1,73,043 | 4,800 ₹1,62,864 Lowest |
| 5.00 | Supply and Fix 300mm SS solid sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, SS sections and fixing bolts and sliding bolts and fixed complete all as specified and directed. | 10 | Each | 250 ₹2,500 Lowest | 350 ₹3,500 |
| 6.00 | Supply and Fix SS 150mm Butt hinges for doors including SS screws | 30 | Each | 90 ₹2,700 | 60 ₹1,800 Lowest |
| 7.00 | Supply and Fix SS 300mm solid handles with matt/glossy finish for doors | 20 | Each | 150 ₹3,000 | 90 ₹1,800 Lowest |
| 8.00 | Supply and Fix SS Door stopper double legged complete all as specified and directed. | 10 | Each | 100 ₹1,000 | 75 ₹750 Lowest |
| 9.00 | Supply and Fix SS 300mm sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed | 10 | Each | 250 ₹2,500 Lowest | 350 ₹3,500 |
| 10.00 | Supply and Fix door closer hydraulically regulated designation No.2 universal type of aluminium extruded section body fixed to doors frameswt 60 to 80 Kg with screws or by welding on steel door frame complete all as specified and directed. | 10 | Each | 1,200 ₹12,000 Lowest | 1,350 ₹13,500 |
Tender Value
₹28.5 L
EMD Value
₹57,000
Closing Date
3 Dec 2025, 6:00 pmClosed
CWE AF NAGPUR
HQ CWE AF NAGPUR VAYUSENA NAGAR, NAGPUR 440007 MILITARY ENGINEER SERVICES
COMPREHENSIVE MAINT OF BR, EM WORK INCLUDING JOINERY, WATER PROOFING, SEWAGE LINE, DRAINS, FENCING COMPOUND WALL, FOOTPATH COOLING APPLIANCES, ETC ELECT SUPPLY, WATER SUPPLY PIPELINE AND OTHER MISC WORKS AT GOVT BLDG AND COMMUNITY HALL AT OADGQA A
2025_MES_739370_1
80718/E8
Open Tender
Civil Works
Item Rate
GE AF OJHAR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE AF OJHAR
₹57,000
Yes
6 Feb 2026
12 Nov 2025
5 Dec 2025
12 Nov 2025
3 Dec 2025
26 Nov 2025
Amount
Taking down Chowkhats or frames exc 1.5 sq. m but n exc 4 sq. m each but with shutters (without taking off shutters from the frame) Note : Rate is inlcusive of forming jamb post removal of chowkhat or frame.
Taking down Shutters of any description exc 1 sq. m and n.exc 2sqm each
Material and Labour for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/ Chowkhat of size 65x 125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately).
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter/ skeletal shutter of size 35mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer In- Charge. (Note: stainless steel butt hinges and necessary S.S screws, SS Wiremesh shall be paid separately)
Supply and Fix 300mm SS solid sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, SS sections and fixing bolts and sliding bolts and fixed complete all as specified and directed.
Supply and Fix SS 150mm Butt hinges for doors including SS screws
Supply and Fix SS 300mm solid handles with matt/glossy finish for doors
Supply and Fix SS Door stopper double legged complete all as specified and directed.
Supply and Fix SS 300mm sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed
Supply and Fix door closer hydraulically regulated designation No.2 universal type of aluminium extruded section body fixed to doors frameswt 60 to 80 Kg with screws or by welding on steel door frame complete all as specified and directed.
Taking down carefully existing bitumen tarfelt including plastering upto 15mm thick cleaning the surface and make free of dirt, foreign particles, laitance followed by grinding all protrusions to make surface modulated and removing all foreign materials / Bituminous primer completely , cleaning and washing the existing surface of roof/slab, terraces including flashings and junctions of parapets/kerb walls etc and as directed. Note : (i) Contractor will not throw the debris and suitable arrangements shall be made to take down the materials from roof. (ii) If taking down of plaster is exceeding 15mm then PCC and plaster both shall be measured under relevant item (iv) Removing of the rubbish to a distance outside MoD land shall be at own arrangement of Contractor.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for including PCC of existing roof, PCC tiles with screed bed and removing the demolished material outside MoD land at own arrangment of Contractor.
Material and Labour for providing cement concrete 1:2:4 Type B0 (Using 12.5mm graded stone aggregate) as in bed plate/roof kerb/PCC padding and haunching etc all as specified and directed. Note : 1.PCC shall be laid in slope and thickness shall be average(minimum average thickness 25mm or as per site requirement for maintaining the slope) as per site including filling in depression by providing concrete bench marks for maintaining th perfect slope to drain out the rain water as directed. 2. No hand mixing is allowed, mixing shall be at ground floor and mixed materials deposited on roof Manually/ mechanically to achieve the proper strength and workmanship. 3. Ponding test is to be carried out for 72 hrs by contractor to check any instances of leekage/seepage , the result of successful ponding shall be certified by Engr-in-Charge.
Material and Labour for rendering 10mm thick in CM 1:3 on concrete surfaces mixed with water proofing compound @ 0.12 ltr per bag of cement or as per manufacturer instruction and finishing the surfaces even and smooth without using extra cement. Note:- (Supply only water proofing compound shall be measured and paid separately) Complete all as specified and directed.
Supply only Liquid water proofing compound Complete all as specified and directed.
Material and Labour for cleaning the newly plastered surfaces thoroughly with wire brushes and providing water proofing treatment all as given here in after (a) Bituminous primer @ 0.3 litre per sqm conforming to IS -3384-1986 (b) 3mm thick APP membrane of approved make with minimum weight of 3kg/sqm membrane (one layer) laid by torch application method. (c) Applying two coat of bituminous based aluminium paint @ 0.20kg in two coats per sqaure metere membrane (one layer) laid by touch application method.. (d) The overlaps of APP shall beas per SSR part 1 and APP shall be laid by expert/skilled workers only, bitumen based aluminous paint applied by brushes only.
Disconnecting existing PVC water tanks of any description, of capacity exc. 500 & n. exc. 1000 lit., setting aside for cleaning etc. and hoisting if required reconnecting and re-fixing in position.complete all as specified & as directed.
Disconnecting existing PVC water tanks of any description, of capacity exc. 1000 & n. exc. 2000 lit., setting aside for cleaning and removing all scale and dirt using detergent powder and bleaching powder etc, and hoisting if required, reconnecting and refixing complete incl ball valve in position and writing date of cleaning on tank with paint after removing the old cleaning date complete all as specified & as directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.
Material and Labour for Rendering 15mm thick on fair faces of brick work or concrete surfaces in 1:4 cement mortar finished even and smooth on external surfaces with with water proofing compound @ 0.12 ltr per bag of cement or as per manufacturer instruction, complete all as specifed and directed.
Material and Labour for applying 2 coat of damp proof paint of approved make as per manufacturers instruction along with priming coat on prepared surfaces complete all as specified and directed.
Removing debries to distance of exc. 1.5 m bu n. exc. 5.00 Km and depositing where directed at a level n. exc. 1.5 m above the starting point. complete all as specified and as directed.
Demolition of cement concrete of any description and in any position complete all as specified and as directed.
Material and Labour for 8-10mm thick light coloured glazed vitrified tile (square/ rectangular) polished, area of each tiles n.exceeding 0.36 sqm but not exceeding 1 Sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with 15mm screed bed 1:6 CM complete all as specified.
Ditto All as per item No. 24, but in skirting over 10mm thick backing coat in 1:4 cement mortar complete all as specified.
Material and labour for 25 mm thick Cement Concrete type B 1 (1:2:4) using 20 mm graded stone aggregate as in sub bases, sub floors . Complete all as specified and as directed.
Supply and Fix in repairs 10 litres capacity PVC Valveless syphonic action type flushing cistern high / low level white complete with inlet , ball valve float and handle including brackets and telescopic down pipes and jointing with WC complete complete all as specified and as directed.
Servicing of Flushing system 10 litres capacity PVC Valveless symphonic action type flushing cistern low level . Taking down the all materials from existing cistern, Cleaned all dirt and refixing the same with making good and leakage free condition for 1 year, including repalcement of folat valve, Syphone, flush washer and flush handle with all fixing arrangments complete all as directed.
Supply and Fix in repairs wash basin mixer cast copper alloy, chromium plated central hole without popup waste system with 450mm long copper pipe and brass nut including hot & cold water system complete all as directed. (Make : Jaquar /Prayag/Plumber or equivalent)
Fixing in repair as in tightening of wash basin mixer/ Wall mixer cast copper alloy, chromium plated central hole without popup waste system with 450mm long copper pipe and brass nut complete all as direceted.
Supply and Fix in repairs wall mixer cast copper alloy, chromium plated 3 in 1 system with provision for both over head shower chromium plated, with wall flange, screwed down, for iron pipe or for brass ferrule including dismantling of 3 No.concealled stop cock & 2 No. bib cock for each mixer (Make : (Make : Jaquar /Prayag/Plumber or equivalent complete all as specified and as directed.
Supply and Fix in repair Pillar taps , cast copper alloy , with capstan heads, chromium plated, screwed down high pressure fancy type of 15 mm bore size with or without lettered Hot or Cold with long screwed shanks and flynuts , screwed for iron pipe and fixed Complete all as specified and as directed.
Supply and Fix in Repair Cast copper alloy CP angle valve type stop cock suitable for 15mm bore pipe screwed at both ends or high pressure with Capstan head . Including dismanteling and making good the tiles if required of make Prayag/Marc/Seiko,Complete all as specified and as directed.
Supply and Fix in Repair bib taps of bore size 15mm, cast copper alloy, , chromium plated, fancy type, with crutch or butter fly handle screwed down , screwed for iron pipe or for brass ferrule Including dismanteling and making good the tiles if required Complete all as specified and as directed.
Supply and Fix in Repair bib tap for Washing machine of bore size 15mm, cast copper alloy, chromium plated, fancy type, with crutch or butter fly handle screwed down , screwed for iron pipe or for brass ferrule of Prayag /Saiko/ Parko Complete all as specified and as directed.
Supply and fixing in repairs 100 mm dia CP brass shower rose swivel type with extension CP rod 15mm dia and 300mm long with connecting rod suitable for 15mm bore pipe .Complete all as specified and directed.
Supply and Fix in Repair CP connection 15mm size with Brass nuts, of length 600mm Complete all as specified and as directed.
Supply and Fix in Repair 32 mm PVC flexible pipe for waste outlet with threaded socket at one end.complete all as specified and as directed.
Supply and Fix in Repairs 40 mm PVC flexible pipe for waste outlet with threaded socket at one end.complete all as specified and as directed.
Supply and Fix in repairs CP health faucet special (1.5 mtr tube) with hook for EWC complete all as specified and directed.
Dismantling of PVC Pipes of any dia complete all as specified and directed.
Supply and Fix for PVC (SWR) pipes, bore of pipe in 110mm, single socketed, in any length, with rubber ring joints, laid in floors or fixed to walls Complete all as specified and as directed.
Supply and Fix PVC (SWR)pipe single socketed in any length with rubber ring joints,laid in floors 75mm dia Complete all as specified and as directed.
Supply and Fix in repairs PVC(SWR) branch pieces, single (Single Y) equal or unequal or with parallel branches 75mm dia Complete all as specified and as directed.
Supply and Fix in repair for PVC (SWR) bends, any radius, bore of pipe in 75mm with cement solvent in position .Complete all as specified and as directed.
Supply and Fix in repair for PVC (SWR) bends, any radius, bore of pipe in 110mm with cement solvent in position Complete all as specified and as directed.
Material and Labour for easing of door shutters for easy closing /opening tightning of hinges or changing the position of hinges adjustment of tower bolts , sliding door bolts with new screw, including taking down to attend to bottom rail etc complete all as specified and directed (rate includes replacement of hinges if required).
Supply and fix in repairs floor door stoppers double legged of aluminium alloy body & tounge aluminium anodised alloy with rubber fixed with steel screws on the door frame of size 150 mm long compete all as specified as directed.
Supply and fixing in repairs GI wire cloth power woven 0.56 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tracks or galvanized wire staples for steel window and ventilator including providing MS beads and SS screws . Complete all as specified and directed.
Supply only SS Wire cloth as in mosquito mesh for WPC door complete all as specified and directed.
Supply and fix in repairs GI wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tracks or wooden beeding patti.to gauge door shutters and wooden windows compete all as specified as directed.
Supply and Fix rubber based door bottom strip with aluminium angle not less than 25x25mm including fixing arrangement with screws properly & all as per manufacturers instruction complete all as specified and directed.
Material and Labour for removing of tree roots, shrubs and bushes from wall surface/roof top/chajjas up to 15 M height including repairing of cracks in cement mortor 1:3 in crarcked surface and making good the surface matching with existing surface including all required ladder and consider all safety measures upto ht 15 mts of bldg etc completed and removal of shrubs up to 50 m distance.
Supply and Fix in repairs Mirror with plastic cabinet of size 550mmx400mmx75mm single door as per approved Make:- Prayag/Nilkamal
Supply and fix in repair SS 25 mm dia bore fancy type drapery rod /curtain rod fancy type brackets cut to length as required in single or double layer of approved colour complete all as directed.
Supply and Fix SS fancy type end balls fixed to SS rod as approved, complete all as specified and directed.
Supply and Fix in repair for 20 mm dia CPVC pipe as on wall , floor , ceiling , concealed etc complete and as directed by Engr in charge with all fittings and fixtured , jointing solution of ISI mark including making grove in wall/ceiling and finished with cement mortor 1:4 with plumbing nails for securing pipes etc directed. Make : Finolex/Dutron/Ashirvad
Supply and Fix in repair for 25 mm dia CPVC pipe as on wall , floor , ceiling , concealed etc complete and as directed by Engr in charge with all fittings and fixtured , jointing solution of ISI mark including making groove in wall/ceiling and finished with cement mortor 1:4 with plumbing nails for securing pipes etc directed Make : Finolex/Dutron/Ashirvad
Taking up or down GI tubing and connections of 15mm bore including cleaning for refixing Complete all as specified and directed.
All as per item No.59 above but 20 mm bore.
All as per item No. 59 above but 25 mm bore .
Supply and fixing tubes medium grade galvanized with all fittings and fixed complete to walls and ceiling or laid in floor (Bore of pipe 15mm) complete all as specified complete all as specified and as directed.
All as per item No.62 above but refixing old servicable pipe .
Supply and fixing tubes medium grade galvanized with all fittings and fixed complete to walls and ceiling or laid in floor (Bore of pipe 20 mm) complete all as specified and directed.
All as per item No 64 above but refixing old servicable pipe complete all as specified .
Supply and fixing tubes medium grade galvanized with all fittings and fixed complete to walls and ceiling or laid in floor (Bore of pipe 25 mm) complete all as specified and directed.
All as per item No 66 above but refixing old servicable pipe complete all as specified .
Forming jambs, etc. to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complete
Taking down existing copper/aluminum existing point wiring (light/fan/socket or power points) complete (fittings such as switches,ceiling roses,pendents, regulators, sockets etc to be measured saperatly) incl wooden battens and conduct etc & removing material as directed complete all as specified and as directed. Note- applicable for BOQ item no 1 to 86 (a)contractor rep/ superviser shall be present at office of Engineer-In-Charge at 9AM every day for taking of instruction regarding repairs to be carried out on the day on priority,(b) alternative technician deploy in place of regular electrician has to work on sunday/holiday to attend faults/defects/complains (c)The repair work on any single day may be order by Engineer-In Charge to be carry out in number of places/building in one day i.e in one buildings quantity of any of BOQ items to be carried may be one or more & number of BOQ items to be executed on any single day may also be one or more(d) Contractor shall not have any claim on account of order of one or more quantity of one or more items of BOQ that to be executed in one or more building and or area in any single day & even the same on any numbers of day during contract period(f) all above mentioned labour effect on this account is deemed to be included in quoted rates by the tenderer for all items of this tender.Note:1) Complaints/Defects will be rectified withen 8 Hrs of intimated time. if complaints not rectified, a recovery of an amount of Rs150/-/ complains/ day will be recoverd from the RAR/ FB , ii) Rates are inclusive of T&P required safety equipment, and transport required contractor shall arrange on his own arrangement, iii).Compliant given by any electronic media i.e SMS, email or whats app etc and in writting shall be count as valid compliant contractor to take immediate action within stipulated time as mention in note.
Material and labour for Point wiring with 1.5 Sqmm (nominal area) PVC ( FRLSH) insulated sheathed copper stranded conductor cable run in and including surface in wall/celling/floor PVC casing caping as per IS with all fittings such as bends, tee,junction boxes,etc of suitable size including 1.5 Sqmm PVC(FRLSH) insulated copper earth continuity conductor connected to common earth dolly and including PVC boxes with surface plate suitable for housing switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed.
All as per item no. 70, but for One 5 Amps socket point on same/below board with other switches.
All as per item no 70, but for One 5amps switch socket point independent.
Material and labour for Point wiring with 2.5 Sqmm (nominal area) PVC ( FRLSH) insulated sheathed copper stranded conductor cable run including surface in wall/celling/floor in PVC casing caping as per IS with all fittings such as bends, tee, junction boxes,etc of suitable size including 2.5 Sqmm PVC(FRLSH) insulated copper earth continuity conductor connected to common earth dolly and including MS/GI sunken boxes with surface plate suitable for housing switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed. Note - Cutting and making good of chasis in wall/roof/floor is included in the qtd rates.
Point wiring with 1.5 Sqmm (nominal area) PVC ( FRLSH) insulated sheathed copper stranded conductor cable run in and including concealed in wall/floor PVC conduit not less than 20 mm as per IS with all fittings such as bends, tee,junction boxes,etc of suitable size including 1.5 Sqmm PVC(FRLSH) insulated copper earth continuity conductor connected to common earth dolly and including MS/GI sunken boxes with modular inner & surface plate suitable for housing modular switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed.
All as per item no. 74, but for One 5 Amps socket point on same/below board with other switches.
All as per item no 74, but for One 5amps switch socket point independent.
Material and Labour for Point wiring with 2.5 Sqmm (nominal area) PVC ( FRLSH) insulated sheathed copper stranded conductor cable run in wall/floor PVC medium grade conduit not less than 20 mm as per IS with all fittings such as bends, tee, junction boxes,etc of suitable size including 2.5 Sqmm PVC(FRLSH) insulated copper earth continuity conductor connected to common earth dolly and including MS/GI sunken boxes with modular inner & surface plate suitable for housing modular switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed. Note - Cutting and making good of chasis in wall/roof/floor is included in the qtd rates.
Material and Labour for wiring for circuit/ sub main wiring of 2x2.5 Sqmm + 1x2.5 Sqmm earth wire, alongwith earth wire PVC (FRLSH) insulated copper conductor, single core, 1100 v grade cable in surface/concealed as required in PVC conduit / cassing capping complete all as directed.
Material and Labour wiring for circuit/ sub main wiring of 2x4 Sqmm + 1x4 Sqmm earth wire, alongwith eart wire PVC (FRLSH) insulated copper conductor, single core, 1100 v grade cable in surface/ recessed as required in PVC conduit/ casing caping complete all as directed.
Material and Labour wiring for circuit/ sub main wiring of 2x6 Sqmm + 1x6 Sqmm earth wire, alongwith eart wire PVC (FRLSH) insulated copper conductor, single core, 1100 v grade cable in surface/ recessed as required in PVC casing caping complete all as directed.
Supply and fix in replacement Switch piano flush type single pole one way 5 Amp Complete all as specified & as directed.
Supply and fix in replacement Modular switch one way 6 Amp,1 Module Complete all as specified & as directed.
Supply and fix in replacement Modular switch one way 16 Amp, 1 Module. Complete all as specified & as directed.
Supply and fix in replacement Modular bell push 6 Amp,1 Module. Complete all as specified & as directed.
Supply and fix in replacement Modular Fan regulator electronic step type 230 V 2 Module. Complete all as specified & as directed.
Supply and fix in replacement Modular Socket outlet 6A/16 Amps 2/3 pin combined 2 module. Complete all as specified & as directed.
Supply and fix in replacement Modular Socket outlet 6 Amps 2/3 pin combined 2 module. Complete all as specified & as directed.
Supply and fix in replacement Bell push flush type 5 Amps. Complete all as specified & as directed.
Supply and fix in replacement Fan regulator electronic step type 230 V. 120W. Complete all as specified & as directed.
Supply and fix in replacement Ding Dong AC 230 Volts single pole. Complete all as specified & as directed.
Supply and fix in replacement Socket out let 2 in 1, 5 pin 5 Amps flush type. Complete all as specified & as directed.
Supply and fix in replacement Switch socket combination outlet 5 pin 6 Amps 16 Amps 2 in 1 flush typein PVC box. Complete all as specified & as directed.
Supply and fix in replacement Switch socket combination outlet 5 pin 5 Amps 2 in 1 flush type in PVC Box .Complete all as specified & as directed.
Supply and fix in replacement Lamp holder PVC/polycarbonate insulated body with back plate suitable for angle fittings. Complete all as specified & as directed.
Supply and fix in replacement Ceiling rose surface type, PVC/Polycarbonate isolated body size 50x28 mm three terminals. Complete all as specified & as directed.
Supply and fix in replacement Sheet metal enclosure for DB’s SPN, with 100 amps rated bus bar ,8 way ,240 volts double door. Complete all as specified & as directed.
Supply and fix in replacement Sheet metal enclosure for DB’s TPN, with 100 amps rated bus bar , 4 way ,415 volts double door.Complete all as specified & as directed.
Supply and fix in replacement Sheet metal enclosure for DB’s SPN, with 100 amps rated bus bar , 4 way ,240 volts double door. Complete all as specified & as directed
Supply and fix in replacement PVC rectangular board 100 mm x 100 mmx 50 mm deep. Complete all as specified & as directed.
Supply and fix in replacement PVC rectangular board 175mm x 100mmx50mm deep. Complete all as specified & as directed.
Supply and fix in replacement PVC rectangular board 200mmx150mmx50mm deep. Complete all as specified & as directed.
Supply and fix in replacement MCB SP 6 to 32 Amps 240 volts 10 KA C series. Complete all as specified & as directed.
Supply and fix in replacement MCB SPN 32 to 40 Amps 240 volts 10 KA. Complete all as specified & as directed.
Supply and fix in replacement MCB TPN 32 to 40 Amps 240 volts 10 KA. Complete all as specified & as directed.
Supply and fix in replacement POLARIS NIO- I 36W LED 5700K Ultra modern recess mounting luminare suitable for armstrong/ grid/ POP ceiling complete with separate electronic driver & high brightness SMD LEDs, complete with connecting accesseries & Driver duly pre-wired and connecting up with 0.5 Sqmm 3 core flexible Copper cable cord from fitting, complete all as specified and directed. MAKE : CROMPTON , Model No. LCTLRNE-36-FO-CDL or equivalent in Bajaj/HAVELLS.
Supply and Fix in replacements and connecting up LED 22 watt inverter fitting 6500K 4 feet with 100 lumen/watt on AC & 450+-10% on DC,PC housing with off white end cap,ABS material off white with surge protection upto 4KV with inverter back up upto 3.5 Hrs & high voltage sustain capacity 440Vac@ 2Hrs ,internal wire PVC coated cable 0.75 sq mm RED/BLACK 12 CCA including all necessary fixing arrangements fastners ,holding brackets & screw etc complete. Crompton cat No LDINVGL22-CDL or equivalent in Philips/Havells ).
Supply and fix in replacement decorative ultra slim square profile linear Light Linea lighting fixture extruded , enviromental frendily, energy efficent ready to use pack 10 W LED 6000K, complete all as specified and directed. MAKE : Crompton, Model No.CCS-103-10-65-SL-DP-NWH or equivalent in Bajaj/ HAVELLS.
Supply and fix in replacement decorative ultra slim square profile linear Light Linea lighting fixture extruded , enviromental frendily, energy efficent ready to use pack 5W LED 6000K, complete all as specified and directed. MAKE : Crompton, Model No.CCS-103-5-65-SL-DP-NWH or equivalent in Bajaj/ HAVELLS.
Disconnecting all existing electric supply and taking down carefully ceiling fan 1200/1400 sweep , dismantlling blades, and repair the same by rewinding,replacement of bush/bearing and capacitor etc. Testing at MES store yard completer all as specified and as directed. Note -Cost for transportation from site to MES store yard & vice versa is deemeed to be included under the quoted rate.
Disconnecting all existing electric supply and taking down carefully exhaust fan 300 mm sweep , dismantlling blades, and repair the same by rewinding,replacement of bush/bearing and capacitor etc , brazing/machine work, painting and testing at MES store yard completer all as specified and as directed. Note -Cost for transportation from site to MES store yard & vice versa is deemeed to be included under the quoted rate.
Supply and fix in replacements capacitor 2.5 MFD, 250 V Heavy duty complete.
Disconnecting carefully water and electric connection from geyser, taking down carefully storage type water heater of any type and capacity and dismantling geyser by removing glass wool, thermostat, heating element for checking of defects, repalcement of defective thermostat, heating element of any capacity, indicating lamps (round/rectangular) flange assembly, top or bottom cover half round plate glass wool etc where required, cleaning of inner container by anti corrosive liquid removing scales repair by brazing, Re-assemblong of geyser and refixing at its original location and testing complete(Replacement of spares such as heating element , thermostat, indicating lamp, top and bottom cover, half round plate, glass wool heating flange assembly will be measured and paid under relevent items) all as directed
Material and Labour for replacement of heating assembly (flange) made out of copper/steel as existing including heat resistance and leak proof gasket suitable for 25 ltrs capacity geyser all as directed. Make : Ditzs/ Racold/ Shakti/Spheroat
All as per item No 113 above but for 35/50 lts capacity
Supply and Fix in replacement thermostat having range 0 to 100 C for geyser as original size of 25/35/50ltrs capacity geyser sutiable for Ditzs/ Racold/ Shakti/Spheroat Make.
Supply and Fix in replacement heating element 2 KW with round or triangular base for 50 ltrs capacity geyser sutiable for Ditzs/ Racold/ Shakti/Spheroat Make.
Supply ans fix in replacement LED street light fittings 25 watt with minimum110 lumen/ watt system lumen output .The luminaire should have cool white coloure temperature with minimum 5700 K. The luminaire housing should be made of pressure die cast aluminium Epoxy power coated with wether proof gasket for LEDs and control gear compartments, heat resistance toughened clear glass fixed with SS screw with IP 66 protection, Make Crompton CAT No CRP-420-25-57-SL-LM-NSGor equivalent in Havells/ Phillips/bajaj.complete all as specified and directed ( For Bldg Security light)
Supply and Fix in replacement lamp indicator with red colour 230 volts complete with fixing arrangement round or rectangular shape and size as per existing geyser suitable for Ditzs/ Racold/ Shakti/Spheroat Make.
Supply and fix in replacement of microprocessor based single phase, AC electronic tamper proof static energy meter LCD display Electronic KWH meter of capacity 5-30 Amp, 240 Volts, 50 HZ, accuracy class 1 , KWh compact meter with pilfer proof meter bo with sealing screw provision base mounting, projection mounted Cat no- SPPB1310000002OC00 of Make:- HPL / L&T /
Supply ans fix in replacement LED street light fittings 60 watt with minimum110 lumen/ watt system lumen output .The luminaire should have cool white coloure temperature with minimum 5700 K. The luminaire housing should be made of pressure die cast aluminium Epoxy power coated with wether proof gasket for LEDs and control gear compartments, heat resistance toughened clear glass fixed with SS screw with IP 66 protection, Make Crompton CAT No CRP-409-60-57-SL-GL-NSG or equivalent in Havells/ Phillips.complete all as specified and directed.
Supply and fix in replacements power contactor, ML-3type Three pole, 440 volt , Auxilary coil voltage 230 Volt, Make- L&T/Legrand/Semiens
Supply and fix in replacements Time digital switch with built in PCB for street light , Make L&T, type DIGICON or equivalent of GEC/ GIC/ Havells.
Supply and fix in replacement flat three core 06 sqmm nominal cross sectional area multistand aluminium conductor cable over all PVC shathed 1100 volt grade Heavy duty cable in PVC conduit fixedon wall ceilling with suitable clamp complete all as specified.
General servicing/maintenance , repair Split AC capacity 1.5/2 Ton ,dismantling unserviceable part of unit including cleaning of air filter,display,PCB,de-dusting of complete(indoor/outdoor) unit ,washing condensor unit with suitable water sprey jet, checking electrical connection cleaning the unit with blower, descaling with non-corrsive acid on both side of coling oil identifying the fault / trouble in unit & their redressal /rewiring complete, greasing of movable parts for getting trouble free service & making Split AC serviceable complete all as specified and directed. (Note: Repair/Replacement of the component required shall be paid under relevant item of scedule here-in-after. 2-the rate for gas charging including refregerent gas will be included in quoted rates for servicing )
Supply and fix in replacement new sealed unit compressor 1.5 Ton split air conditioner Make: Kirloskar complete all as specified & as directed. (Note- Cost of refrigerant gas and Gas charging is deemed to be included with this item )
Supply and fix in replacement new sealed unit compressor 2.0 T for split air conditioner Make:Kirloskar complete all as specified & as directed. (Note- Cost of refrigerant gas and Gas charging is deemed to be included with this item )
Supply and fix in replacement new fan motor 1/3 Hp, 230 v for split AC Make AUE or equivalent all as specified and as directed.
Supply and fix in replacement running capacitor for split Air conditioner 1.5 T/2 T of capacity 36/45 mfd , 7 point ,440 VAC Make Epcos, complete all as specified and as directed.
Supply and fix in replacement starting capacitor for split Air conditioner 1.5 T/2 T of capacity 80/100 mfd 440 VAC Make Epcos, complete all as specified and as directed.
Supply and fix in replacement Relay (8500-4) (Make Annapurna) suitable for Air Conditioner mentioned above, complete all as specified & as directed.
Supply and fix in replacement remote control switches 1.5 Ton to 2 Ton capacity split A/C of any make as existing sample complete all as specified & as directed.
Supply and fix in replacement blower motor single phase AC 200/230 volts suitable for split model A/C of capacity 1.5 TR, complete all as specified & as directed.
All as per item no 127, but for 2 TR complete all as specified & as directed.
Supply and fix in repair Bush with Blower shaft assy complete,1.5 Ton to 3 Ton capacity split A/C of make as existing sample,complete all as specified & as directed.
Supply and fix in repair Printed Circuit Board (PCB) For split A/C of make as existing sample ,complete all as specified & as directed.
Repairs to Circuit of existing Printed Circuit Board (PCB) in split type AC of any make, complete all as specified & as directed.
Supply and fix in replacement condensor coil of copper suitable for 1.5 TR/2 TR split type air conditioner including taking down old unserviceable condensor coil from existing position complete all as directed and specified.
Supply and fix in replacement copper tubes 2 mm thick for additional length required in the process of maitenance of the split air conditioners unit, with insulation of puff or TF quality of thermocole or poly urithine insulating tubes all as specified for 5/8/1/4 inch copper tubing complete all as specified & as directed.
Supply & Fix in replacement LED Post top 40 watt lantern weather proof indirect lighting solution Make Cormpton Cat Pt No LPTO-40-CDL-M or equivalent in Havells/Bajaj.complete all as specified and directed.
Supply & Fix in replacement Post top lantern decorative HERITAGE LED suitable 1X20 Watt retro LED with opel deffuser of Make Crompton Cat Part No LPTH-20-CDL or equivalent in Havells/ Wipro.complete all as specified and directed.
Supply and fix in replacement street light bracket 32/40 mm bore GI pipe/tubing light grade not less than 1.2 Mtr long band to shape with 2 nos MS clamps flat iron 50 x 5 mm for nuts, bolts and washers suitable for Steel/PCC Pole etc and applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed. Make- Prakesh surya/Swastik/Jindal
Material and labour for cable joint termination box PVC body housing suitable for housing and including 100 amps rated, 3 phase, 4 wire system mounted on PVC insulators for one incomming and two out going cable entry space mounted on street light PCC/ tublar pole with 25x3 mm FI clamps with nut, bolts and washers and including one 6 amps MCB, SP, 240 volt for street light supply complete all as as directed.
Material and labour for Preparation of old painted surfaces of steel tublar poles LT 9.0 Mtr long & painting two coats of aluminium paint from top to bottom and painting with alternate strip of blue paint at an interval of 1 feet from bottom of pole upto 6 feet height, including existing cross arm/angle iron/clamps/brackets etc & marking of pole numbers in white on black background all as directed.
Note : The amount against Schedule of Credit on Page No. 43 shall be deducted from the total amount quoted against Sch 'A' while deriving lum Sum for Acceptance.
M/s.TIRUPATI BUILDERS (BID ID -3503875)
Bidder Name
Santhi Enterprises
M/s.TIRUPATI BUILDERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.61 MB
BOQ_827899.xls
BOQ • 0.41 MB
PS80718.pdf
Tender Documents • 1.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .