Loading…
Loading…
Tender Value
₹38.2 L
EMD Value
₹76,400
Closing Date
25 Jun 2026, 3:00 pm
Electrical work in connection with - Up-gradation of infrastructure and Augmentation of maintenance facilities in C&W Workshop Bikaner and Provision of construction of new weigh bridge ( Capacity 100 MT) in store depot and Construction of double storey space for storage of non-ferrous material including staff room, parking and toilets etc.
04-Elec-WS-BKN-2025-26R
04-Elec-WS-BKN-2025-26R
Open
10 Months
Bikaner, Rajasthan
₹0
₹76,400
3 Jun 2026
3 Jun 2026
11 Jun 2026
A-Up-gradation of infrastructure and Augmentation of maintenance
Recessed/Surface conduit wiring system-Supply of material and wiring of LP/TP/FP/Exhaust fan/ Bell point with single core multistrend copper conductor size 1.5 Sq.mm with earth wire in PVC conduit pipe with 5/6 Amp modular type switch/ceiling rose/batten holder etc.
Supply of material & fixing of flush metal box of 2-Module with connection used for concealed modular flush metal box wiring.
Supply of material & fixing of plate Inner & Outer 2-Module used for concealed modular wiring.
Supply of material & fixing of flush metal box of 4-Module with connection used for concealed modular flush metal box wiring.
Supply of material & fixing of plate Inner & Outer 4-Module used for concealed modular wiring.
Supply of material & fixing of flush metal box of 6-Module with connection used for concealed modular flush metal box wiring.
Supply of material & fixing of plate Inner & Outer 6-Module used for concealed modular wiring
Supply of material & fixing of flush metal box of 12-Module with connection used for concealed modular flush metal box wiring
Supply of material & fixing of plate Inner & Outer 12-Module used for concealed modular wiring.
Supply & fixing of blank plates (1- Module) used for concealed modular wiring.
Supply of material & fixing of 6/16 Amp. 6-pin/3pin combined shuttered socket with switch (2-Module) with switch used for concealed modular wiring.
Supply of material & fixing of 6 Amp. 5-pin/3pin socket with switch (2-Module) used for concealed modular wiring.
Supply, fixing & connection of moduler type Ceiling rose 3plate 6 Amp., 240 Volt, ISI marked
Supply, fixing & connection of Ceiling rose 3plate 6 Amp., 240 Volt, ISI marked, As per specification.
Supply & fixing of 5/6 amp. 5 pin socket with switch on existing MS board.(Non modular type)
Supply & fixing of 15 amp. 6 pin socket with switch on existing MS board. .(Non modular type)
Supply and fixing of MS board 300x200x50mm manufactured by 1.6mm MS sheet duly finished with two coats of red oxide , earth terminal, 3mm sunmica sheet, zinc plated/ brass screw, cup washer etc in recessed
Supply and fixing of MS board 175x100x50mm manufactured by 1.6mm MS sheet duly finished with two coats of red oxide , earth terminal, 3mm sunmica sheet, zinc plated/ brass screw, cup washer etc in recessed
Supply and fixing of MS board 100 X100 X50 manufactured by 1.6mm MS sheet duly finished with two coats of red oxide , earth terminal, 3mm sunmica sheet, zinc plated/ brass screw, cup washer etc in recessed
Supply, installation, testing & commissioning of Piano type one way switch 6 Amp. ISI marked. As per specification.
Supply & fixing of 32 A 5 Pin Panel Mounted Industrial Plug & Socket, with MCB 3 Phase AC, 230/415 Volt. with enclosure.
Supply and fixing of PVC conduit/casing capping (as per instruction of site supervisor) and its accessories, size 25 mm, thickness 1.6 mm As per IS 9537 part I.
Supplying and drawing 4.0 sq. mm PVC insulated multi-strand copper conductor 23 cable as sub-main and 1.5 sq. mm PVC insulated multi- strand earth copper cable voltage grade 1.1 kV as earthing wire conforming to IS: 694-1990 in existing conduit/casing capping. Wire should be of reputed make and as per tech. spec.
Supplying and drawing 6.0 sq. mm PVC insulated multistrand copper conductor cable 24 as submain and 1.5 sq. mm PVC insulated multistrand earth copper cable voltage grade 1.1 kV as earthing wire conforming to IS: 694-1990 in existing conduit/casing caping. Wire should be of reputed make and as per tech. spec.
Supplying and drawing 2.5 sq. mm PVC insulated multistrand copper conductor cable 25 as submain and 1.5 sq. mm PVC insulated multistrand earth copper cable voltage grade 1.1 kV as earthing wire conforming to IS: 694-1990 in existing conduit/casing caping. Wire should be of reputed make and as per tech. spec.
Fixing of LED four feet fitting complete with tube /LED Panel light 36 Watt in 2feet x 2feet
Fixing and commissioning of ceiling fan/ wall fan/ exhaust fan with nut bolt ensuring all safety aspects. Contractor is responsible for falling of fan within a period of 12 month.
Supply and fixing of junction box size 390/388x 305/304 x170mm comprising of SMP/ 28 FRP material with rubber gasket, padlock arrangement, zinc passivated earth bolt, etc. Make Sintex or similar with 4 no. aluminum busbar cap 200 Amp., suitable for 415 volt supply requirement. The box shall be fixed robustly with clamps at pole/ wall as per requirement. All the material should be of good quality.
Supply and fixing of Double Door MCB DB SP 12 way (10+2 module), neutral and 29 earth link, with one no DP MCB 40 amp, one no DP RCCB 40 amp 30 mA and eight no SP MCB 32/25/16/10/6 amp. 'C' series. Breaking capacity not less than 10 kA. MCB, RCCB and DB should be as per tech spec. and of same make.
Supply, fixing and commissioning of Electronic bell, operating voltage 230 V AC. Bell should be of reputed make.
Design, manufacturing, supply, testing, erection and commissioning of LT panel 31 made by 2 mm CRCA sheet with 1 no. Incomer 250A MCCB and Outgoing - 2 no. 4 pole MCCB 125 amps.,2 nos. 4 pole MCCB 63 amps. and 2 nos. 4 pole MCCB 40 amps. with meter & indication LED, copper bus bar etc as per spec.
Digging and filling of trench size 0.4 x 0.8 mtr as per spec. ( trench work may be on kuchha/ pucca land and all type of soil as per site requirement and without protective layer of brick ) Surface of trench shall be made good in all respect and satisfaction of site engineer.
Supply of HDPE pipe, 160 mm dia, conforming to IS 4984: 2016 as per site requirement.
Laying of Spun/MS/GI/DWC / HDPE pipe 100mm to 200 mm by drilling of Horizontal bore by machine in Railway yard/ below track /Road.
Supply of HDPE pipe conforming to IS 4984:2016, 75/80 mm dia, wall thickness minimum 3 mm, under the road.
Laying of HDPE pipe conforming to IS 4984:2016, 75/80mm dia, wall thickness minimum 3 mm, under the road. The work involves laying of HDPE pipe.
Supply of HDPE pipe conforming to IS 4984:2016, 50 mm dia, wall thickness minimum 3 mm, under the road.
Laying of HDPE pipe conforming to IS 4984:2016, 50 mm dia, wall thickness minimum 3 mm, under the road. The work involves laying of HDPE pipe.
Supply of unit maintenance free earth material as per RDSO Specs. No RDSO/PE/SPEC/PS/0/0109 (REV.0 ) 2008 or Latest
Installation of unit maintenance free earth as per RDSO Specs. No RDSO/PE/ SPEC/PS/0/0109 ( REV.0) 2008 or Latest
Supply and fixing of occupancy sensor
Supply of 3 core 1.5 sqmm XLPE multistrand FR Flexible cable copper cable unarmoured as per IS : 7098(Part 1)(Q2)
Supply of 4 core 2.5 sqmm multicore FR Flexible copper cable as per IS : 694(Q3)
Supply and fixing of TPN MCCB double door DB12+2 way with 4P100A (25 kA)MCCB- 1 no., 2P63A, 100 mA RCCB-3 nos. and2P 25A 'C' series10 kA MCB-18nos. MCCB, MCB,RCCB and DB should be as per tech spec. and of same make.
Supply and laying of insulating mats for electrical purpose, class-Category -II width 1000 mm, thickness 3mm,rating AC (RMS) 33kv, DC volt 240,as per spec, ISI marked IS:5424/69 in black/red chequared pattern.
Supply, laying, & fixing of GI pipe medium "B" class (Blue) confirming to IS 1239 part-I for passing incoming and outgoing cable from ground through it size 100mm dia. Pipe should be of reputed make.
Fixing & commissioning of Split AC (AC will be supplied by Railway)
Supply and fixing of copper tube 3/8" with insulating material.
Supply and fixing of copper tube 1/4" as per specification
Provision of 1/2" PVC drain pipe as per specification
Supply, fixing, testing and commissioning of RCBO with enclosure 25A, double pole, 30mA with earth leakage, overload and short circuit protection as per tech
Laying, connecting, testing and commissioning of 4 core 35 to 240 sqmm, 1.1KV grade, LT XLPE/PVC insulated PVC outer X sheathed aluminum conductor armoured cable in trench/pipe/air as per spec.
Fixing of LED 250 W Flood /street light complete with tube. (Fitting is not included in it).
Supply, fixing and commissioning of street light/Flood light fitting accessories e.g. GI pipe of bore 25 mm, clamps, nuts, bolts, cable etc as per instruction of site engineer
Supply and fixing of MCB DP 32 amp with box . Breaking capacity not less than 10 KA.
Supply and providing of cable marker - for underground cable (Other than PLTC) The 56 cable marker shall be made of MS sheet 1.5 mm thick size 150 x 200 mm welded with 12 mm dia MS rod 01.50 Mtrs long. The lower end of rod should be turned in hooks shape and attached with the cable at the laying.
SITC of pole junction box of size 250x 250 x100 mm made by powder coated ms sheet of 1.6mm including 4 pole connector and SP mcb 6 Amp.
B-Provision of construction of new weigh bridge ( Capacity 100 MT) in
Recessed/Surface conduit wiring system-Supply of material and wiring of LP/TP/FP/Exhaust fan/ Bell point with single core multi strend copper conductor size 1.5 Sq.mm with earth wire in PVC conduit pipe with 5/6 Amp modular type switch/ceiling rose/batten holder etc.
Supply of material & fixing of flush metal box of 2-Module with connection used for concealed modular flush metal box wiring.
Supply of material & fixing of plate Inner & Outer 2-Module used for concealed modular wiring.
Supply of material & fixing of flush metal box of 4-Module with connection used for concealed modular flush metal box wiring.
Supply of material & fixing of plate Inner & Outer 4-Module used for concealed modular wiring.
Supply of material & fixing of flush metal box of 6-Module with connection used for concealed modular flush metal box wiring.
Supply of material & fixing of plate Inner & Outer 6-Module used for concealed modular wiring
Supply of material & fixing of flush metal box of 12-Module with connection used for concealed modular flush metal box wiring
Supply of material & fixing of plate Inner & Outer 12-Module used for concealed modular wiring.
Supply & fixing of blank plates (1- Module) used for concealed modular wiring.
Supply of material & fixing of 6/16 Amp. 6-pin/3pin combined shuttered socket with switch (2-Module) with switch used for concealed modular wiring.
Supply of material & fixing of 6 Amp. 5-pin/3pin socket with switch (2-Module) used for concealed modular wiring.
Supply, fixing & connection of modular type Ceiling rose 3plate 6 Amp., 240 Volt, ISI marked
Supply and fixing of PVC conduit/casing capping (as per instruction of site supervisor) and its accessories, size 25 mm, thickness 1.6 mm As per IS 9537 part I.
Supplying and drawing 4.0 sq. mm PVC insulated multi-strand copper conductor 15 cable as sub-main and 1.5 sq. mm PVC insulated multi- strand earth copper cable voltage grade 1.1 kV as earthing wire conforming to IS: 694-1990 in existing conduit/casing capping. Wire should be of reputed make and as per tech. spec.
Supplying and drawing 6.0 sq. mm PVC insulated multi strand copper conductor 16 cable as submain and1.5 sq. mm PVC insulated multi strand earth copper cable voltage grade 1.1 kV as earthing wire conforming to IS: 694-1990 in existing conduit/casing caping. Wire should be of reputed make and as per tech. spec.
Supplying and drawing 2.5 sq. mm PVC insulated multi strand copper conductor 17 cable as submain and 1.5 sq. mm PVC insulated multi strand earth copper cable voltage grade 1.1 kV as earthing wire conforming to IS: 694-1990 in existing conduit/casing caping. Wire should be of reputed make and as per tech. spec.
Fixing of LED four feet fitting complete with tube /LED Panel light 36 Watt in 2 feet x 2 feet
Fixing and commissioning of ceiling fan/ Plastic wall fan with nut bolt ensuring all safety aspects. Contractor is responsible for falling of fan within a period of 12 month.
Supply and fixing of Double Door MCB DB SP 12 way (10+2 module), neutral and 20 earth link, with one no DP MCB 40 amp, one no DP RCCB 40 amp 30 mA and eight no SP MCB 32/25/16/10/6 amp. 'C' series. Breaking capacity not less than 10 kA. MCB, RCCB and DB should be as per tech spec. and of same make.
Digging and filling of trench size 0.4 x 0.8 mtr as per spec. ( trench work may be on 21 kuchha/pucca land and all type of soil as per site requirement and without protective layer of brick ) Surface of trench shall be made good in all respect and satisfaction of site engineer.
Laying of Spun / MS / GI Pipe 100 mm by pushing method in Railway Yard below track as per technical spec.
Supply of HDPE pipe conforming to IS 4984:2016, 75/80 mm dia, wall thickness minimum 3 mm, under the road.
Laying of HDPE pipe conforming to IS 4984:2016, 75/80 mm dia, wall thickness minimum 3 mm, under the road. The work involves laying of HDPE pipe.
Supply, Fixing, testing & commissioning of exhaust fan sweep size 300 mm suitable for 230 volt AC 50 Hz complete with accessories.
Supply of unit maintenance free earth material as per RDSO Specs. No RDSO/PE/SPEC/PS/0/0109 (REV.0 ) 2008 or Latest
Installation of unit maintenance free earth as per RDSO Specs. No RDSO/PE/ SPEC/PS/0/0109 ( REV.0) 2008 or Latest
Supply and fixing of fan box/ fan hook.
Supply and fixing of occupancy sensor
Supply of 3 core 1.5 sqmm XLPE multistrand FR Flexible cable copper cable unarmoured as per IS : 7098(Part 1)(Q2)
Supply and fixing of TPN MCCB double door DB12+2 way with 4P100A (25 kA)MCCB- 1 no., 2P63A, 100 mA RCCB-3 nos. and2P 25A 'C' series10 kA MCB-18nos. MCCB, MCB,RCCB and DB should be as pertech spec. and of same make.
Supply, laying, & fixing of GI pipemedium "B" class (Blue) confirming to IS 1239 part-I for passing incoming and outgoing cablefrom ground through it size 100mm dia. Pipe should be of reputed make and as per tech. spec.
Supply, fixing, testing and commissioning of RCBO with enclosure 25A, double pole, 30mA with earth leakage,overload and short circuit protection as per tech
Laying, connecting, testing and commissioning of 4 core 50 to 240 sqmm, 1.1KV grade, LT XLPE/PVC insulated PVC outer X sheathed aluminum conductor armoured cable in trench/pipe/air as per spec.
Fixing of LED 250 W Flood /45 W street light complete with tube. (Fitting is not included in it).
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCwithcorrectionslip1to10.pdf GCC with correction slip 1 to 10
ATTACHMENT
GCCACS11.pdf
ATTACHMENT
AnnexureVandVA_1_1.pdf
ATTACHMENT
TechnicalSpec..pdf
ATTACHMENT
GCCwithcorrectionslip1to10.pdf
ATTACHMENT
Download all tender documents and submit your bid