Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.0 LAccepted-AOC WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC LOWEST QUOTED | |
| 2 | L2₹11.3 L+₹10,110 (0.90%)Rejected-Finance 94 PHASE II HOUSEING COLONY UDHAMPUR J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-Finance OTHER THAN LOWEST QUOTED | |
| 3 | L3₹11.6 L+₹43,215 (3.86%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST QUOTED |
Tender Value
Refer Docs
EMD Value
₹29,560
Closing Date
12 Apr 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF UDHAMPUR
GE AF UDHAMPUR,PIN-182101
ADDN/ ALTN TO OPS ROOM COMPLEX IN BUILDING NO 08 OF HQ AOC J AND K AT AF STATION UDHAMPUR
2021_MES_430836_1
GEAFU-58/2020-21
Open Tender
Civil Works - Others
Item Rate
180 days
AF STATION UDHAMPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF UDHAMPUR
₹29,560
Yes
20 Apr 2021
15 Mar 2021
14 Apr 2021
15 Mar 2021
12 Apr 2021
29 Mar 2021
60 days
Amount
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc., laid, bedded and pointed in any mortar complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster, of any description on brick or stone or cement concrete walls/ceiling including raking out joints, hacking for key, scrubbing down with water complete all as specified.
Dismantling wall and ceiling boards (fibre, pulp, gypsum, POP, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified.
Taking down chowkat or frames with shutters (without taking off shutters from the frames) exc. 1.5 Sqm but n.exc 4 Sqm each including cutting holes for taking out hold fasts, dismantling brick work (holes cut and any other damages to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost) complete all as specified.
Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m mean radius, built in cement mortar 1:6, complete all as specified.
S & F GI frame work for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20mm and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre /intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section of 0.55mm thickness having kurled web of 50mm and flange of 26mm each lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre complete size of grid 605 x 605mm all as specified and directed
S & F Non asbestos fibre cement designer building boards, 4 mm thick, fixed or laid/ inserted to GI/aluminium framework with screws in ceiling, complete all as specified.
S&F solid PVC wall lining/paneling consisting of 5 mm thick any colour/teak face colour PVC sheet inclusive of solvant cement and fixed at site on PVC frame as per specifications and as shown in drawing on page No.162 of SSR Part-II (2010) complete all as specified and as directed by Engineer-in-Charge.
5 mm thick PVC sheet fillet of width 35 mm for wall paneling inclusive of fixing on to wall to make PVC frame complete all as as per specifications and as shown in drawing on page No.162 of SSR Part-II (2010) complete all as specified and as directed by Engineer-in-Charge.
Powder coated anodized aluminium frame for doors, windows, ventilators,partition wall etc, fixed glazing with one or more rebates including joining cleat for fixing, fixed to opening with suitable size steel screws and rawl plugs etc., (aluminium section not less than 2 mm) complete all as specified.
Powder coated anodized aluminium three track shutters for display board of any size, aluminium section of minimum 2.5 mm thick,including necessary joining cleats, glazing clips, ruber neoprene packing, hinges 03 nos ,anodised aluminum snap beading screws etc. complete all as specified
M&L dark colour digital vitrified tiles 10 mm thick(Square/Rectangular) polished area of each tiles exc 1.00 Sqm but not exc 1.28 Sqm in floors etc set and jointed in neat cement slurry and pointed in liquid epoxy tile grout to match over and including screed bed bedding layer of 15 mm thick in CM 1:4 complete all as spfd, colour and design approved by Engr-in-Charge Make:-Somanay,Kajaria,Johnson,Nitco
M&L light colour digital vitrified tiles 10 mm thick(Square/Rectangular) polished area of each tiles exc 1.00 Sqm but not exc 1.28 Sqm in floors etc set and jointed in neat cement slurry and pointed in liquid epoxy tile grout to match over and including screed bed bedding layer of 15 mm thick in CM 1:4 complete all as spfd colour and design approved by Engr-in-Charge Make:-Somanay,Kajaria,Johnson,Nitco
15 mm thick rendering on fair faces of brick/concrete/stone surfaces in cement mortar 1:6 and finished even and smooth without using extra cement complete all as specified.
Preparation of newly plastered surfaces of wall and apply two coats of distemper oil emulsion (OBD) over a coat of cement wall primer (from same manufacturer of OBD) etc complete all as specified and directed.
Plywood 6 mm thick, grade BWR, type BB, having one side decorative teak veneer fixed with nails to timber frame work, complete all as specified.
Sheet glass 5.5 mm thick tinted fixed to doors and windows with rubber gasket etc. ,complete all as specified and directed by Engr-in-charge.
Two coats of synthetic enamel paint over & including a coat of red oxide primer over new steel & iron surfaces of any description, not otherwise described, over 10 cm in width or girth, including preparation of surfaces complete all as specified and directed by Engineer-in-Charge.
S&F aluminium snap bedding for fixing of glass for partition, complete all as specified and directed by Engineer-in-Charge.
S&F rubber gasket for fixing of board panel in aluminium frame, complete all as specified and directed by Engineer-in-Charge.
Taking down carefully aluminum/copper point wiring (light/ fan/socket or power) complete with fittings such as switches, tube lights, ceiling rose, pendants, regulators, MCB DB, MCBs, Main switches from control board and making good disturbed surfaces of walls, floor to match with existing specifications complete all as specified.
Point wiring using approved colour coding as per IS for one light/bell/buzzer/fan point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through & including PVC, rigid concealed conduit, heavy duty, 19/20mm dia, ISI marked, with and including new modular sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with the existing specifications complete all as specified. Note :-Switches, sockets, outlets & regulators will be measured and paid for separetely.
Point wiring for one 6 Amps socket outlet on the same board controlled by one switch with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through & including PVC, rigid concealed conduit, heavy duty, 19/20mm dia, ISI marked, with and including new modular sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with the existing specifications complete all as specified. Note :-Switches, sockets, outlets & regulators will be measured and paid for separetely.
Point wiring for one 6 Amps socket outlet independent controlled by one switch with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through & including PVC, rigid concealed conduit, heavy duty, 19/20mm dia, ISI marked, with and including new modular sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with the existing specifications complete all as specified. Note :-Switches, sockets, outlets & regulators will be measured and paid for separetely.
Point wiring for one 16 Amps socket outlet independent with PVC insulated, unsheathed FRLS multi stranded copper conductor 2.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through & including PVC, rigid concealed conduit, heavy duty, 19/20mm dia, ISI marked, with and including new modular sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 2.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with the existing specifications complete all as specified. Note :-Switches, sockets, outlets & regulators will be measured and paid for separetely.
Switch modular type 6 AMP,one way , one module conforming to IS-3854 complete all as speciifed and as directed
Switch modular type, 16/20 Amp, one way, one module conforming to IS-3854 complete all as specified and as directed.
Socket shuttered outlet 2/3 pin, 6 Amp modular type, 2 modules complete all as specified and as directed.
Socket shuttered outlet 2-in-1, 6/16 Amp modular type, 2 modules complete all as specified and as directed.
Ceiling rose, surface bakelite 65 x 50mm, two to three terminals complete all as specified and as directed.
Modular electronic fan regulator 2 modules rotary step type 230 volts complete all as specified and as directed.
Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade cable as earth wire,including suitable size of PVC conduit drawn through PVC surface/concealed conduit and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiring and disposing from site complete all as specified and as directed. Note: Two runs each of one RM of 4.00 sqmm main cable and one RM of 4.00 sqmm cable earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose.
Vertical three phase distribution board, TPN, 4 way 440 volts having IP-54 protection, double door with provision for fixing of MCCBs as incomer and MCBs as outgoing complete after taking down existing unservicable main switch, busbar, GI box including accessories therein including taking down old unserviceable, complete all as specified and as directed.Make:CAT PART NO:507680 of Legrand or equavalent to HAVELLS / SIEMENS/Schneider
S&F Recess mounting type LED indoor luminaire powder coated, CRCA or powder coated aluminium panel 2' x 2' (Appx) system wattage 40 watt to 45 watt (cool white), minimum system lumen efficacy not less than 80 % , CRI not less than 80, colour temperature not less than 6000 K, power factor not less than 0.95, surge protection device min 2 KV, LED driver with constant output voltage and current at input voltage of 140volt to 285 volt AC, 50 HZ, THD less than 10%, life 50,000 burning hours minimum IP protection IP 20, powder coated housing with ashthetic bottom frame, with excellent heat dissipation through high thermal conductivity, high efficiency transulence diffuser, suitable for any type of ceiling system including connection with PVC insulated copper conductor 3 core cable of 0.50 sqmm complete all as specified.MAKE :CAT Part No:D-414065 of wipro or equavalent to Havells/Philips/Crompton Note :The contractor shall submit to Engineer-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively while getting sample and material approved.
S&F Single pole and neutral enclosure with a two pin and earth plug with socket complete with one singlepole MCB 20 Amps, 240 volts complete all as specified and as directed. Make: Legrand / HAVELLS / SIEMENS/Schneider
Taking down carefully old unserviceable existing conventional light fittings such as T-5/ T-8/ box type/ bulk head, 1x40 watt ; 1x20 watt, ceiling panel lights etc from existing buildings , all as specified and as directed by Engineer-in-Charge. Note : Existing serviceable LED luminaries will not be taken down / replaced.
Rigid non-metallic PVC conduit of dia 32mm concealed in wall exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.
S&F LED spot light system wattage of 25/28/30 watts with lifetime of 50000 burninh hours with 70% of its initial lumen maintained, CRI >80, Power factor >0.95, THD <10%, IP-20 protected, meets LED IS specification, class-1, short circuit and over circuit protection, voltage range- 150 to 270 volts AC, Temperature range 0 to 50 Degree system efficiency at luminarie level > 80 lumens/watt and including fixing on necessary suitable mounting track/rail for easy moving operation required at site and fixed complete all as directed by Engr-in-charge. Make:CYLINDROTS25WLE830S3WIRE38DWHTV of havells or equivallent to Wipro/C&S/Philips
Taking down airconditioner of any capacity without damaging/wasting of gas in side ops room and reassembing, commisioning including providing copper tubing all as per site requirement including servicing and gas charge complete all as directed by Engr-in-Charge.
MCB SPN 40 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic ,complete all as specified and as directed. Make:CAT PART NO:408618 of Legrand or equavalent to HAVELLS / SIEMENS/Schneider
MCB single pole, 06-32 Amp, 240 Volts, having breaking capacity 10 kA 'C' characterstic ,complete all as specified and as directed. Make: Legrand / HAVELLS / SIEMENS/Schneider
MCCB Four pole 415 Volts 50 Hz 100 Amps rating with rupturing capacity not less than 36 kA, Ics = 100% Icu, adjustable thermal & adjustable megnetic settings with spreader links, copper reducer etc including taking down existing old unservicable including accessories therein complete all as specified and as directed. Make: Legrand / HAVELLS / SIEMENS/Schneider
Earthing complete with copper earth plate electrode of size 60 cm x 60 cm x 3.15 mm thick as earth electrode burried directly in ground (earth pit not less than 2.25 Meter deep below ground level) with top edge of the earth plate not less than 1.5mtr below ground level using copper earth strip 20 x 3 mm dia as earth continuity conductor connected to earth plate by means of copper thimbles, nuts, bolts, washers including jointing of earth electrode and earth wire by means of welding, all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and pit cover made of MS sheet 2 mm thick duly fixed to angle iron frame with hinges of appropriate size by welding and having locking arrangement, adequate quantity of charcoal dust and salt all around the erth plate, earth work in any type of soil , removing surplus excavated material all as required at site and as specified in EP No 3 of MES SSR Part-I (2009) directed by Engineer-in-charge including testing on completion. Note :- 1.5 cubic metre of soil shall be provided by the contractor from outside the MOD land for refilling the remaining portion of earth pit for increasing soil resistance without any extra cost to the Govt.
Supply, laying , jointing , commissioning and testing cable (armoured) XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with stranded aluminium conductors, 1100 volts grade of size 70 sqmm ,3.5 core with saddles and gutties,including taking down old unserviceable, complete all as specified and directed by Engr-in-Charge
SHIVAE CONSTRUCTION
KARAN TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .