Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹54.2 CrAccepted-Finance A 403 CITY CENTRE NEAR RESHAMBHAVAN STATION ROAD SURAT 315003 | 315003 | ₹54.2 Cr | L1 | Accepted-Finance Lowest rate found. |
| 2 | L2₹60.4 CrAccepted-Finance | ₹60.4 Cr | L2 | Accepted-Finance High rate found. |
Tender Value
Refer Docs
EMD Value
₹57.6 L
Closing Date
17 Sept 2021, 2:00 pmClosed
The Exe., Engg., PWD, WD-I, Daman.
The Multi Office Complex, PWD, 2nd Floor, Near Moti Daman Market, Moti Daman.
Construction of Transport Nagar at Bhimpore, Nani Daman. (3rd Call) (E-30055)
2021_DAMAN_1825_1
Tender Notice No.42/2021-22
Open Tender
Civil Works
540 days
Daman District.
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,500
The Exe., Engg., PWD, WD-I, Daman.
₹57.6 L
The Exe., Engg., PWD, WD-I, Daman.
28 Sept 2021
1 Sept 2021
17 Sept 2021
1 Sept 2021
17 Sept 2021
1 Sept 2021
9 Sept 2021
Amount
Civil work
CIVIL WORKS: Excavation for foundation in sand, gravel, clay soft soils and murrum etc. including shoring, strutting dewatering as necessary and disposing of the excavated stuff as directed. (A) Depth upto 3.0 M. and upto all lead and lift.
Excavation for foundation in sand, gravel, clay soft soils and murrum etc. including shoring, strutting dewatering as necessary and disposing of the excavated stuff as directed. (B) Depth from 3.0 to 6.0 M.and upto all lead and lift.
Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20 cm. in depth consolidating each deposited layer by ramming and watering etc. complete. Upto all lead and lift.
Filling in foundation and plinth with sand in layers of 20 cm. Thickness including watering ramming and consolidating etc. complete.
Providing and filling rubbles including hand packing and filling voids with sand as directed including ramming and consolidating etc. complete. Upto all lead and lift.
Caring out plinth treatment to post construction / existing structure by spraying chemical solution for termite control treatment including labour and material consistent with I.S.I specification. Using Chlordene and Chiorpurfiles 20 EC. As Per 6131_paret-II Concentration Weight one percent is recommended i.e. one litre 20 EC chemical emulsion with 19 litre give 1 % concentration inclusive of one litre chemical emulsion application at the rate of 5 Litre chemical / Sqm of surface is recommended as per I.S.
Providing and laying cement concrete 1:3:6 (1-Cement : 3- coarse sand : 6- hand broken stone aggregates 40 mm nominal size) and curing complete including cost of formwork in (A) Foundation and Plinth
Providing and laying controlled cement concrete M.250 and curing complete including the cost of formwork & admixtures as per Mix Design and excluding the cost of reinforcement for reinforced concrete work in (A) Foundations and Piles
Providing and laying controlled cement concrete M.250 and curing complete including the cost of formwork & admixtures as per Mix Design and excluding the cost of reinforcement for reinforced concrete work in (D) Columns, Pillars posts and struts All Floor level.
Providing and laying controlled cement concrete M.250 and curing complete including the cost of formwork & admixtures as per Mix Design and excluding the cost of reinforcement for reinforced concrete work in Tie Beams/ Beams/ Lintel/ Coping at All Floor Level.
Providing and laying controlled cement concrete M.250 and curing complete including the cost of formwork & admixtures as per Mix Design and excluding the cost of reinforcement for reinforced concrete work in Slab and Weathersheds at All Floor Slab Level.
Providing and laying controlled cement concrete M.250 and curing complete including the cost of formwork & admixtures as per Mix Design and excluding the cost of reinforcement for reinforced concrete work in RCC Walls at All Floor level.
Providing and laying controlled cement concrete M.250 and curing complete including the cost of formwork & admixtures as per Mix Design and excluding the cost of reinforcement for reinforced concrete work in Staircase at All Floor level.
Providing and fixing in expansion joint 100 mm thick expansion joint board of best quality and approved make including cutting to required size and shape at all levels etc. complete as directed.
Applying and providing Expansion joint sealing System on 100 mm vide joint including cleaning of exansion joint by mechanical means provision of adhesive and flexible membrane with required bond length as per menufracturer specification and 4mm thick alluminium strip covering with one side sloted and bolted with suitable system, inclusive of all manpower, machinery and material as per specification and as directed.
Providing and filling the expansion joint by polymer or equivalent confirm to BS 4254-1983 as per required shade and manufactured specifi-cation by making groove of 50 mm x 12.5 mm lather by cutting or by repairing groove and removing mortar drop or any other foreign materials including applying primer and filling required size (oversize of joint PU foam etc. complete. at all floor level.
Extra for additional height of propping and centering where the height of propping and centering exceeds 4.0 M between supporting floor to ceiling including temporary brick or stone pillars for supporting as required.
Providing Thermo Mechanically Treated bar (T.M.T.) (I.S.I. Mark) conforming to I.S. - 1786 Fe-500D CRS Steel including providing fusion bonded Epoxy coating not less than 175 micron thickness and up to 300 micron to reinforcement bars as per IS-13620- 1993/ ASTM-775M. for R.C.C. work including bending, binding and placing in position complete at all floor level.(below/above Plinth)
Brick work using common burnt clay building bricks having crushing strength not less than 35 kg./Sq.Cm. in Cement Mortar 1:6 (1- Cement : 6 -fine sand) (B) Conventional All Floor level (below/above Plinth)
Half brick masonry in common brunt clay building bricks having crushing strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:3 ( 1-Cement : 3-coarse sand ) with 2 Nos of 6mm Mild steel round bars after every three course embedded in Cement Mortar (B) Conventional All Floor level
Providing and fixing rolling shutters of approved make made of 80 mm wide M.S. laths inter-locked together through their entire length and jointed together at the ends by end locks mounted on specially designed pipe shaft with bracket plates, guide channels and arragements for inside and outside locking with push-pull operation including the cost of hood cover and spring etc. complete.(A) Shutters having width below 3.5 M.
Providing and fixing Glass Doors using Teak Wood Frame of size 75 x 250 mm having 12mm thick Toughened Glass with Film of pattern and brand as approved by the Architect including fixing of all required accessaries of approved brand as per detailed drawing / as directed by Engineer In-charge etc.complete.
Providing and fixing 35 mm thick Double Shutter Panelled Doors using Polished Teak Wood Frame of size 75 x 250 mm having Plywood Shutters with both size Decorative Veneer fixed with waterproof adhesives having pattern and brand as approved by the Architect, with Stainless Steel Handles, Tower Bolt (Door Stopper) & Heavy Stainless steel Aldrop including fixing of all other accessaries of approved brand as per detailed drawing / as directed by Engineer In-charge etc.complete.
Providing and fixing 38 mm thick Single Shutter Flush Doors using Teak Wood Frame of size 75 x 150 mm having BWP Shutters with both size Decorative Laminate fixed with waterproof adhesives having pattern and brand as approved by the Architect, with Stainless Steel Handles, Tower Bolt (Door Stopper) & Heavy Stainless steel Aldrop including fixing of all other accessories of approved brand as per detailed drawing / as directed by Engineer In-charge etc. Complete.
Providing and fixing coloured Powder Coated/Anodized Alluminium section Three Track windows using JINDAL Delux series sections or equivalent having Min. Wt 2.50 Kg /Rmt.for Frame and Min. Wt 1.02 Kg /Rmt. for Shutter and having Shutter of 5 mm thick transperant/tinted glass and Mosquito Nets including anodized aluminum fixture and fastenings etc. complete as per detailed drawings and directions of Engineer in-charge.
Providing and fixing coloured Powder Coated/Anodized Alluminium section Ventilations using JINDAL Delux series sections or equivalent having Min. Wt 1.20 Kg /Rmt.for Frame and having Louvers of 5 mm thick transperant glass fixed with Aluminium borders and Mosquito Nets including anodized aluminum fixture and fastenings etc. complete as per detailed drawings and directions of Engineer in-charge.
Providing and fixing M.S. grills / Gates of required pattern to brick walls / Columns prepared with M.S. flats, angles, Square / round bars, square pipes, at required spacings with necessary hold fasts as per detailed drawing and fixing brick walls / coping / columns etc. complete including painting two coat & applying primer coat. (A) Ornamental Grill
Providing, Fabricating and fixing Steel Works in required pattern/ design using Structural Steel/Bright Bars as per detailed design/ drawings/ instructions including cutting, bending, jointing, connecting, welding and / bolting and / riveting and fabricating and erecting in position etc complete for all levels as directed . The rate to include all necessary fixtures, fastening including one coat of primer and two coats of mat finished oil painting etc complete.
Providing and laying Mirror polished Jet Black Granite slab 18-20 mm (Average) thick for Doors / Windows sill & Jams Cladding as per design incl. full moulded round both edge on 10 mm thick cement mortar 1:3 (1 -cement : 3 coarse sand ) jointed with grey cement slurry including rubbing and polishing etc. complete
Providing and laying Lather finished Kota stone slab 18-20 mm thick {Single piece not more than 150 cm long} for stair steps and riser as per design incl. finishing the edges in trade of steps laid on 20 mm thick cement mortar 1:6 (1 -cement : 6 coarse sand) and risers and skirting on 10 mm thick cement Plaster 1:3 (1 -cement : 3 coarse sand ) and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as per direction of Engineer In-charge.
Providing and laying Lather finished Granite stone slab 18-20 mm thick {Single piece not more than 150 cm long} for stair steps and riser as per design incl. finishing the edges in trade of steps laid on 20 mm thick cement mortar 1:6 (1 -cement : 6 coarse sand) and risers & Skirting on 10 mm thick cement Plaster 1:3 (1 -cement : 3 coarse sand ) and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as per direction of Engineer In-charge.
Providing and laying 60 cm x 60 cm MATT Vitrified Tiles (Basic Rate of ₹ 1000/Sq.M) flooring over 20 mm (average) base of cement mortar 1:6 ( 1 cement: 6 coarse sand) on new surface or fixing on existing flooring by adhesive material including dismantling of existing flooring and jointed with colour cement slurry including finished with flush pointing & cleaning the surface and including filling the joints with Approved Epoxy Grout in 3-4 mm width and10 mm Depth including cost of PVC Spacers, Rubbing, Cleaning etc. complete.
Providing and laying 60 cm x 60 cm MATT Vitrified Tiles (Basic Rate of ₹ 1000/Sq.M) 8 mm thick of approved shade in skirting, risers of steps and dado on 10 mm thick cement plaster 1:3 (1 Cement : 3 coarse sand) and jointed with white cement slurry including filling the joints with Approved Epoxy Grout in 3-4 mm width and10 mm Depth including cost of PVC Spacers, Rubbing, Cleaning etc. complete.
Providing and fixing roofing consist of 0.8 mm thick galvanized steel deck sheet confirming to IS 277:1992 used as permanent shuttering over which MS wire mesh 3mm laid at 100x100 mm grid including edge trim covered with concrete. This metal deck will be supported on structural steel beam with shear studs.
Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge etc. complete.
Providing and laying broken china mosaic flooring for terrace using 12 mm to 20 mm broken pieces of glazed tiles to be laid over cement mortar 1:3 to plain or slope and to be tempered to bring mortar creme out upto surface using white cement including rounding off junctions, and sealing with cement vata and extending them upto 15 cm along the wall, clearing with water and oxalic acid etc. as directed.
Providing and Fixing Glass Railing of 1.0 m height using 12 mm thick toughened Glass with a supports of Stainless Steel Sections as per design and drawings approved by Architect and instructions of Engineer in-charge including cutting, moulding, fixing in place etc. complete.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing 15mm thick cement plaster in single coat on Rough (Similar)side of single or half brick walls for interior plastering upto floor two level and finished even and smooth in (ii) Cement mortar 1:4 (1-cement :4-sand) All Floor level.
Providing 10 mm. Thick cement plaster in single coat for plastering on ceiling and soffits of stairs upto floor two level and finished even and smooth in : (I) Cement mortar 1:3 (1 cement : 3 sand) All Floor level.
Providing 20 mm thick double coat mala cement plaster on exterior brick/ concrete work for plastering comprising of base coat of 12 mm thick cement plaster in cement mortar (1 cement : 4 coarse sand) in rough finishing and 8 mm thick top coat of cement plaster 1:2 (1 cement : 2 Coarse Sand) finished with trovel including scaffolding curing etc. Complete at all height.
Applying two coats of Birla or Asian acrylic lappy (putty) and two coats of primer of approved brand and manufacture on new wall surface to give an even shade including thoroughly brushing the surface free from mortar dropping and other foreign matter and sand papered smooth.
Wall painting (two coats) with plastic emulsion paint of approved brand and manufacture on undecorated wall surface to give an even shade including throughly brushing the surface free from mortar droppings and other foreign matter and sand papered smooth etc.complete.
Finishing wall with weather proof exterior emulsion paint on wall surface (two coats) to give an required Texture and Shade as per approved Architectural Elevation after thoroughly brushing the surface to remove all dirt, and remains of loose powdered materials etc complete
Providing and fixing Chicken Wire Mesh/jali of 25 gauge having 150 mm minimmum width at the junctions of Brick Masonry and reinforcement cement concrete members using cement mortar of 1:3 at all height as per direction of Engineer In-charge including cutting, fixing, scaffolding etc. complete.
Providing 12 mm wide grooves/ notch in plaster at the junctions including finishing the same etc. complete at all height.
Constructing Sandwich Platform of 18 mm thick Polished Black Granite at top and 30 mm thick Kota stone slab flooring fitting at bottom with cementing Materials / adhesives including making necessary grooves in walls including all labour material of approved quality incl. full moulded round front edge fixed in wall for partition and jointed with grey cement slurry including rubbing and polishing etc. complete
Providing and laying Both side mirror polished Granite stone slab 18 mm (Average) thick of approved quality incl. full moulded round front edge fixed in wall for partition and jointed with grey cement slurry including rubbing and polishing etc. complete
Providing, laying and jointing in true line and level 160 diametre U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain and other end socketed with rubber ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 160 mm diametre x 210 mm length x 196 mm heigh at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials.
Supplying of screened cleaned pea (rounded) gravel of following sizes)(i) 10mm nominal size.
Supplying of screened cleaned pea (rounded) gravel of following sizes)(ii) 12mm nominal size.
PAVEMENT WORKS: Clearing and Grubbing Land. (Clearing and grubbing land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials - By Mechanical Means: In area of light jungle.
Construction of dowel jointed, Cement Concrete Pavement (Concrete Grade M-40) over a prepared sub base with 53 grade cement @ 425 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including cost of expansion joint, joint filler, separation membrane of impermeable plastic sheeting 125 micron thick, sealant primer, joint sealant, debonding strip, M.S. Dowel Bar, Tie Bar, admixtures as approved, curing compound, finishing to lines and grades etc.. as directed by E.I.C (minimum 425 Kg. cement/Cu.mt. concrete )
Construction of Dry Lean Cement Concrete Sub-base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a pavefr with electronic ensor, compacting with 8-10 tonnes vibratory roller, fininshing and curing.
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401.
Construction of Subgrade (Construction of subgrade with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2)-For Subgrade Material CBR>8.
Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. WMM 1st Layer & 2nd Layer as per MORTH Clause : 406.
Providing and Laying compacted dense graded bituminious macadam as per MORTH Clause: 505 (DBM) Grade-2 in single layer using 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour, tack coat at the rate of 2.5 Kg / 10 m2 in each using crushed aggregates of specified grading premixed with bituminious content @ 4.5% (VG-40) by weight of total mix and filler, transporting the hot mix to work site laying with a hydrostatic paver finisher with sensor control with minimum road width or as directed by Engineer in charge to the required grade, level and alignment, rolling with smooth wheeled vibratory and tandem rollers to achieve the desired compaction as per MORT&H specification etc complete in all respects. The agency shall have to get the mix design done from approved laboratory and submit to the Engineer in charge for Approval. If the asphalt (bituminious) content is more than above, the agency shall have to bear the cost of additional asphalt. The payment shall be done on the permissible field density achieved on the ite instead of density derieved in the mix design. (Assume density = 2.40 gms / cm3)
Providing and Laying Bituminious Concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour capacity using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4% (VG-40) of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause no 507 complete in all respects.
Prime coat (Providing and applying primer coat with bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 kg/sqm using mechanical means.)
Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408 - Using Concrete Batching and Mixing Plant.
Kerb Painting: Painting Two Coats on New Concrete Surfaces (Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces)
Providing and fixing pre-cast Rubber Dye inter locking concrete block 60 mm thick with grade of concrete M40 pumatic compressed by mechanically pressed and as per approved desing including 35 mm sand layer for levelling and filling the joint with sand in proper line and level.
Turfing Lawns with Fine Grassing including Ploughing, Dressing including breaking of clods, removal of rubbish, dressing and supplying doobs grass roofs at 10 cm apart, including supplying and spreading of farm yard manure at rate of 0.6 cum per 100 sqm.
Transition Section between Rigid and Flexible Pavement (Due to change in the properties of materials and type of construction, a gradual changeover from rigid pavement to flexible pavement is desirable to avoid any damage at the butting joint. After provision of an expansion joint in the cement concrete slab, the thickness of slab should be tapered to 10 cm over a length of 3 m towards the flexible pavement. The deficiency of thickness caused due to tapering of the slab should be made up by the asphaltic layers.) Total Anchor Beam Qty M35 Per Meter
Transition Section between Rigid and Flexible Pavement (Due to change in the properties of materials and type of construction, a gradual changeover from rigid pavement to flexible pavement is desirable to avoid any damage at the butting joint. After provision of an expansion joint in the cement concrete slab, the thickness of slab should be tapered to 10 cm over a length of 3 m towards the flexible pavement. The deficiency of thickness caused due to tapering of the slab should be made up by the asphaltic layers.) Total Qty of Steel (bars) Per Meter
Transition Section between Rigid and Flexible Pavement (Due to change in the properties of materials and type of construction, a gradual changeover from rigid pavement to flexible pavement is desirable to avoid any damage at the butting joint. After provision of an expansion joint in the cement concrete slab, the thickness of slab should be tapered to 10 cm over a length of 3 m towards the flexible pavement. The deficiency of thickness caused due to tapering of the slab should be made up by the asphaltic layers.) Rubberized Bitumen Sealant
Transition Section between Rigid and Flexible Pavement (Due to change in the properties of materials and type of construction, a gradual changeover from rigid pavement to flexible pavement is desirable to avoid any damage at the butting joint. After provision of an expansion joint in the cement concrete slab, the thickness of slab should be tapered to 10 cm over a length of 3 m towards the flexible pavement. The deficiency of thickness caused due to tapering of the slab should be made up by the asphaltic layers.) Expansion Joint
Providing and fixing of Solar road stud (cats eye) of 100x100 mm, die-cast in aluminium, resistant to corrosive effect of salt and grit, installed in concrete or asphaltic surface by drilling hole 30 mm upto a depth of 60 mm and bedded in a suitable bituminous grout or epoxy mortar, all as per BS 873 part 4:1973
Retro-reflectorised Traffic signs (Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing) - High Intensity Grade 60 x 60 cm Square (Entry)
Retro-reflectorised Traffic signs (Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing) - High Intensity Grade 60 x 60 cm Square (Exit)
Retro-reflectorised Traffic signs (Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing) - High Intensity Grade 60 x 45 cm Rectangular (Direction/Place Identification)
Retro-reflectorised Traffic signs (Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing) - High Intensity Grade 80 x 60 cm Rectangular (Direction/Place Identification)
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.
LANDSCAPE WORKS: Clearing and grubbing road land including uprooting rank vegetation grass bushes,shrubs,sapling and trees girth up to 300 mm removal of stumps of trees cut earlier and disposal of unserviceable materials (C) By mechanical means in area of light jungle
Excavation for foundation upto 1.5 m depth including sorting out and stacking of useful materials and disposing off the excavated stuff (B) Dense or Hard soil
Brick work using common burnt clay building bricks having crushing strength not less than 35kg/Sqcm. in foundation and plinth. In cement mortar 1:5 (1 cement : 5 fine sand) (B) Conventional
Providing and laying average 18-20 mm. thick Sand faced cement plaster on masonry work / RCC wall upto any height above ground level and for all shapes consisting of first coat (backing coat) average 12-15 mm. thick with CM 1:3 (1 cement: 3 coarse sand) rough wired finish and second coat of average 6 mm. thick uniform grained textured by using wooden Gutka, in CM 1:3 (1 cement: 3 sand), including with necessary scaffolding, finishing, curing, making grooves, forming pattas, hacking properly RCC surface, hexagonal chickenmesh of size 20 mm. x 20 mm. of 22 gauge at junction of concrete and brick work or between different materials, etc. as directed. (for all civil, plumbing & electrical works) by the Architect and Engineer-in-charge.
Providing and laying cement concrete 1:3:6 (1-Cement : 3- coarse sand : 6- hand broken stone aggregates 40 mmnominal size) and curing complete excluding cost of formwork in (A) Foundation and Plinth (Make specified as per appendix-1)
Providing and fixing pre-cast concrete kerb stone of gray cement based concrete block 30cm length,30cm height and 15cm thick of M250 grade concret as per approved design and including excavation for fixing in proper line and level,filling the joint with C:M 1:3 (1cement:3fine sand) etc complete. (Brands: Vyara, Alcock)
Filling in plinth with sand under floors including watering ramming, consolidating and dressing complete (upto 10 ton)
Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density,& having CBR 30% minimum, complete as per clause 401
Providing and laying polished Kota stone slab flooring over 20mm (Average) thick base of cement mortar 1:6 (1-cement : 6-coarse sand) or L.M. 1.1.5 (1-Lime putty :1.5 - coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing etc. complete. (A) 25mm thick
Providing and laying Riverwash/natural finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineering- Charge : Flamed finish granite stone slab Jet Black or equivalent.
Providing and laying Mandana stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineering- Charge : Colour Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and fixing Washed stone grit peeble Plaster with 12 mm cement plaster bedding 1:4 (1 cement: 4 coarse sand ), furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2 Kg of cement per square metre, top layer 15 mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10 mm nominal size), in panels with groove all around as per approved pattern including scrubbing and washing the top layer with brushes and water to expose the stone chippings, complete as per specification and direction of Engineer-incharge
Providing and laying Paver Cobel Granite Stones (100 mm x 100 mmx50mm) over 1:3 cement mortar (1 cement : 3 graded medium coarse sand) bedding of average 1” thickness, floated with thick and neat cement paste with consumption of cement @4.4kg/ sqm and 2 kg /sqm for joints mixed with approved pigment to match the shade of the stone including dressing, rubbing, curing, cleaning etc. complete at all levels and heights. (the rate shall be for the patterns and details provided by the Architect. If required, residues will be provided and no extra amount will be paid for residues to be used to achieve the pattern).
Providing, Supplying, Fabricating & Fixing Pergolas using FRAME OF 80X40X3.0 MM THICKNESS CRC PIPES WITH REQUIRED SUPPORT FOR OUTER FRAMING OF PERGOLA, MIDDLE MEMBERS OF (20X40X1.6X2.0MM) REQUIRED DEFINE SIZES AND AS PER THE DRAWING AND THE REFERENCE IMAGE GIVEN, FOOTING AND FITTING OF THE REQUIRED METAL PILLARS WITH A DESIRED ANGLE SUPPORT IN BOTTOM OF PERGOLA, FITTING TILL THE HEIGHT OF 10-12 FT FROM GROUND LEVEL, CURVES IN PERGOLA DIMENSIONED WITH BE AS OF TRIANGLE SHAPED WILL BE GIVEN PRECISELY AT SITE VISIT, PERGOLA SIZE APPROX 18MTR X 12MTR X 21MTR CURVED FROM EDGES AND TRIANGULAR IN SHAPED PERGOLA DESIGNED including REQUIRED MATERIAL WITH ALL LABOR CHARGES COLOR WORK and FITTING AND TRANSPORT etc.complete as per direction of Engineer In-charge.
HORTICULTURE WORKS: Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).
Supplying stacking and spreading of good earth at site including royalty and carriage upto 5 k m lead complete (earth measured in stacks will be reduced by 20% for payment).
Carting of soil from inside plant area, including to loading , unloading and transport
Supplying , stacking and spreading sludge / well decayed farm yard manure from thesource approved by the engineer in charge incl. screening, loading, unloading, conveyance and stacking at site.
Mixing earth and manure or in proportion specified or directed, Spreading of dung manure or / and good earth in required thickness. and fine dressing the ground as per natural gradiant
Planting saplings of plants/ trees in the proper beds as prepared , and maintaining the same for Two months by involving all the operations like multing, de-weeding , hoeing , forking, watering and application of chemical fertilizer, insecticides/pesticides etc. for the following trees/ plants (the pit shall be filled with fresh soil and manure, i.e as stacked at site,Digging holes in ordinary soil and carting away the excavated earth and refilling the holes with the fresh soil mixed with manure or in the ratio of 2 : 1 by volume the excavated earth shall be placed within premises at required place, rolling, levelling, watering and compaction etc. in required gradient complete as directed.Holes 1.2 m dia and 1.2 m deep Big Trees (The height of plant shall be considered as 8'-10’ and girth size 60mm-80mm). Albizia lebbek, Melea azedirach, Acacia auriculiformis, Dalbergia Sissoo, Emblica officinalis, Dalbergia Sissoo, Emblica officinalis, Azadirachta Indica, Bauhinia variegata, Pongamia pinnata, Butea monosperma, Bauhinia variegata, Cassia fistula, Erythrina indica, Terminalia bellirica, Terminalia arjuna, Commiphora caudata, Albizia saman, Bauhinia x blakeanea, Milingtonia hortensis, Roystonea regia, Caryota urens, Lagerstroemia speciosa, Tamarindus indica, Gliricidia sepium, Colviller racemosa, Alstonia scholaris, Delonix regina, Stercullia foetida, Klgellia pinnata, Senna siamea, Borassus flabellifer, Phoenix sylvestris, Tabebuia rosea, Hyphaene dichotoma, Holoptelea integrifolia, Spathodea companulata, Millingtonia hortensis, Alianthus excelsa, Bombax ceiba, Livistonia chinensis, Washingtonia robusta.
Planting the hedges/shrubs approx 10-12 plants per sq mtrs, border plants as mentioned below including making pits/trenches suitably to implant shrubs, including filling the fresh earth and manure and maintaining the same for Two months involving all the operations like multching , de- weeding ,hoeing, forking , application of chemical fertilizer ,insecticides / pesticides and trimming in proper shape.Digging holes in ordinary soil and carting away the excavated earth and refilling the holes with the fresh soil mixed with manure or in the ratio of 2 : 1 by volume the excavated earth shall be placed within premises at required place, rolling, levelling, watering and compaction etc. in required gradient complete as directed.Holes 0.15 m dia and 0.15 m deep. Shrubs approx 109580 nos. and 2'-3' height and girth size 8mm-12mm: Calotropis procera, Jatropha integerrima, Thevetia peruviana, Turnera ulmifolia, Stachytarpheta indica, Pseuderanthemum reticulatum, Senna alata, Pennisetum setaceum, Pennisetum setaceum rubrum, Cymbopogon citratus, Chrysopogon zizanioides, Saccharum munja, Carrisa congesta, Ruellia tuberosa, Barleria cristata, Bambusa tuldoides, Ixora singaporensis, Hamelia patens, Nerium oleander, Euphorbia milli, Leucophyllum frutescens, Ixora brachiata, Pandanus odoratissimus, Stachytarpheta jamaicensis, Calliandra haematocephala, Tabernaemontana 'Dwarf', Quisqualis Indica, Cliloria ternatea, Allamanda cathartica, Russelia quisetiformis, Schefflera arboricola, Acalypha hispida, Tecoma smithii, Malvaviscus penduliflorus, Pandanus baptistii
Planting saplings of ground covers in the proper beds as prepared , and maintaining the same for Two months by involving all the operations like multing, de-weeding , hoeing , forking, watering and application of chemical fertilizer , insecticides / pesticides etc. for the following trees/ plants (the pit shall be filled with fresh soil and manure, i.e as stacked at site,Digging holes in ordinary soil and carting away the excavated earth and refilling the holes with the fresh soil mixed with manure or in the ratio of 2 : 1 by volume . the excavated earth shall be placed within premises at required place, rolling, levelling, watering and compaction etc. in required gradient complete as directed.Holes 1.2 m dia and 1.2 m deep. Ground Covers approx 246555 nos. and min. 6" height and girth size 5mm-8mm: Wedelia trilobata, Asparagus sperengeri, Jacquemontia violacea, Senecio orange, Asystasia gangetica, Ficus repens, Setcresea purpurea, Tradescantia spathacea
FIRE FIGHTIG WORKS: SUB-HEAD: I :PUMP ROOM : Supply, installation, testing and commissioning of 2850 LPM @ 90m Head Main diesel engine driven horizontal centrifugal end suction top discharge pump set as per IS :12469 specification with bronze impeller, EN8 shaft and SS410 shaft sleeve coupled with diesel engine heat exchanger cooled provided on common base plate including exhaust piping, muffler, silencer, fuel tank with diesel for testing as well for future storage (fuel storage capacity shall be kept in order to run the pump at least for 2 hrs for ordinary hazard and 3hrs for high hazard), diesel engine controller, battery with battery charger, coupling guard, foundation bolts etc.as per the statutory requirement.
Supply, installing, testing, & commissioning of Electric motor driven Main Pump suitable for automatic operation consisting of the following (as per specification for External + Internal hydrant system).Back Pull out centrifugal type pump complete for delivery of 2850 LPM against a total head of 90 metres with bronze impeller, shaft SS complete with mechanical seal with Complete accessories like Earthing, Local Push Button, Cabling between Panel and Pump Motor. Including Squirrel cage induction motor. Conforming to requirements of IS.
Supply, installing, testing, & commissioning of electric motor driven Jockey Pump suitable for automatic operation consisting of the following (as per specification). Electric driven automatic pressurisation pump set consisting of the following. Vertical In line, centrifugal Multistage Jockey pump complete for delivery of 250 LPM against a total head of 90 metres with SS impeller complete with mechanical seal with Complete accessories. Squirrel cage induction motor suitable for above pump.2
Supplying, installing and commissioning of Bourdon type Pressure gauge (150mm dial) with gauge cock - range 0-25 kg/sq.cm(g).
Supplying, installing and commissioning of Pressure switch (2SPDT) with needle valve.
Supplying, installing and commissioning of Exhaust pipe - 150 mm dia M.S. 'B' class pipe with Rockwool insulation & 24SWG aluminium sheet cladding. Including MS supports
Supply, Installation, Testing & commissiooning of Mild Steel black pipes, ERW, Heavy grade conforming to IS:1239 up to 150 mm dia. and IS:3589 for pipes above 150 mm dia. complete with fittings, reducers, tees, high tech supports, structural clamps such as rods, channels, angles, nuts, bolts & washers, as required to be firmly mounted on the MS steel structural members.10 % of all the welded joints shall be done rediographically tested and 50% of the joints radiographed shall be the "Field Joints" & hydrostatic testing for 2 hours at 150% of the system pressure, hook-up etc. Painting for piping, fittings, hanger support with U clamp, U bolt, threaded rods, nut, bots & washers & structural pipe support shall be one coat of zinc primer and two coats of fire red enamel paint Shade No.536 of IS 5: 1994 complete with all accessories as per approved drawings, specification and direction of the Engineer-in-Charge.Rate shall include supply and fixing of all MS supports. 250mm nominal dia
Supply, Installation, Testing & commissiooning of Mild Steel black pipes, ERW, Heavy grade conforming to IS:1239 up to 150 mm dia. and IS:3589 for pipes above 150 mm dia. complete with fittings, reducers, tees, high tech supports, structural clamps such as rods, channels, angles, nuts, bolts & washers, as required to be firmly mounted on the MS steel structural members.10 % of all the welded joints shall be done rediographically tested and 50% of the joints radiographed shall be the "Field Joints" & hydrostatic testing for 2 hours at 150% of the system pressure, hook-up etc. Painting for piping, fittings, hanger support with U clamp, U bolt, threaded rods, nut, bots & washers & structural pipe support shall be one coat of zinc primer and two coats of fire red enamel paint Shade No.536 of IS 5: 1994 complete with all accessories as per approved drawings, specification and direction of the Engineer-in-Charge.Rate shall include supply and fixing of all MS supports. 200mm nominal dia
Supply, Installation, Testing & commissiooning of Mild Steel black pipes, ERW, Heavy grade conforming to IS:1239 up to 150 mm dia. and IS:3589 for pipes above 150 mm dia. complete with fittings, reducers, tees, high tech supports, structural clamps such as rods, channels, angles, nuts, bolts & washers, as required to be firmly mounted on the MS steel structural members.10 % of all the welded joints shall be done rediographically tested and 50% of the joints radiographed shall be the "Field Joints" & hydrostatic testing for 2 hours at 150% of the system pressure, hook-up etc. Painting for piping, fittings, hanger support with U clamp, U bolt, threaded rods, nut, bots & washers & structural pipe support shall be one coat of zinc primer and two coats of fire red enamel paint Shade No.536 of IS 5: 1994 complete with all accessories as per approved drawings, specification and direction of the Engineer-in-Charge.Rate shall include supply and fixing of all MS supports. 150mm nominal dia
Supply, Installation, Testing & commissiooning of Mild Steel black pipes, ERW, Heavy grade conforming to IS:1239 up to 150 mm dia. and IS:3589 for pipes above 150 mm dia. complete with fittings, reducers, tees, high tech supports, structural clamps such as rods, channels, angles, nuts, bolts & washers, as required to be firmly mounted on the MS steel structural members.10 % of all the welded joints shall be done rediographically tested and 50% of the joints radiographed shall be the "Field Joints" & hydrostatic testing for 2 hours at 150% of the system pressure, hook-up etc. Painting for piping, fittings, hanger support with U clamp, U bolt, threaded rods, nut, bots & washers & structural pipe support shall be one coat of zinc primer and two coats of fire red enamel paint Shade No.536 of IS 5: 1994 complete with all accessories as per approved drawings, specification and direction of the Engineer-in-Charge.Rate shall include supply and fixing of all MS supports. 100mm nominal dia
Supplying, installing and commissioning of Cast iron double flanged Sluice Valve conf. to IS: 14846, PN-16 with fittings, nut, bolts & washers, flanges etc. 200mm nominal dia
Supplying, installing and commissioning of Cast iron double flanged Sluice Valve conf. to IS: 14846, PN-16 with fittings, nut, bolts & washers, flanges etc.150mm nominal dia
Supplying, installing and commissioning of Cast iron wafer type lever operated butterfly valve conf. to IS: 13095, PN-16 with fittings, flanges, nut, bolts & washers, etc. MOC of the Body & disc shall be CI as per IS:210 FG200, EPDM / Neoprene seat, carbon steel (EN8) shaft and nylon / Teflon bearing. Valves exceeding 150 mm dia shall be gear operated. 100mm nominal dia
Supplying, installing and commissioning of Dual plate Wafer type Non Return valve with PN 16 rating, fittings, flanges, nuts, bolts, washers etc. 200 mm nominal dia
Supplying, installing and commissioning of Dual plate Wafer type Non Return valve with PN 16 rating, fittings, flanges, nuts, bolts, washers etc. 100 mm nominal dia
Supplying, installing and commissioning C.I. Y type Strainer with suitable flanges, nuts, bolts, gaskets etc. complete. 200 mm nominal dia
Supplying, installing and commissioning C.I. Y type Strainer with suitable flanges, nuts, bolts, gaskets etc. complete. 150 mm nominal dia
Providing, fixing, testing and commissioning of air-cushion tank (air vessel) 350mm dia. & 1500mm high with dished top, made of 8 mm thick M.S. sheet and 10 mm thick dished ends with 25mm dia. brass air release valve (ball type).
Fabricating & Supply, installing, testing and commissioning of Control Panel with Cabling & Cable tray for Fire pumps.
Providing, fixing, testing and commissioning FM approved Fire Pump test Flow Meter, venturi / magnetic type, reading in m3/hr or GPM, suitable meter range, suitable for maximum working pressure 25 KG/SQCM , in-line installation as shown in drawings and of approved make as specified. 200mm Dia
Providing, fixing, testing and commissioning FM approved Fire Pump test Flow Meter, venturi / magnetic type, reading in m3/hr or GPM, suitable meter range, suitable for maximum working pressure 25 KG/SQCM , in-line installation as shown in drawings and of approved make as specified. 100mm Dia
Supply, installation, testing & commissioning of Flexible connections for pumps 200mm Dia
Supply, installation, testing & commissioning of Flexible connections for pumps 100mm Dia
SUB-HEAD: II :FIRE HYDRANT SYSTEM :- Supply, Installation, Testing & commissioning of Mild Steel black pipes, ERW, Heavy grade conforming to IS:1239 up to 150 mm dia. and IS:3589 for pipes above 150 mm dia. complete with fittings, reducers, tees, high tech supports, structural clamps such as rods, channels, angles, nuts, bolts & washers, as required to be firmly mounted on the steel structural members. 10 % of all the welded joints shall be done rediographically tested and 50% of the joints radiographed shall be the "Field Joints" & hydrostatic testing for 2 hours at 150% of the system pressure, hook-up etc. Painting for piping, fittings, hanger support with U clamp, U bolt, threaded rods, nut, bolts & washers & structural pipe support shall be as per technical specification with all accessories as per approved drawings, specification and direction of the Engineer-in-Charge. ( Pipe - JINDAL Make) For aboveground Piping MS structural supports & Civil pedesgtral will be paid separately 200mm nominal dia
Supply, Installation, Testing & commissioning of Mild Steel black pipes, ERW, Heavy grade conforming to IS:1239 up to 150 mm dia. and IS:3589 for pipes above 150 mm dia. complete with fittings, reducers, tees, high tech supports, structural clamps such as rods, channels, angles, nuts, bolts & washers, as required to be firmly mounted on the steel structural members. 10 % of all the welded joints shall be done rediographically tested and 50% of the joints radiographed shall be the "Field Joints" & hydrostatic testing for 2 hours at 150% of the system pressure, hook-up etc. Painting for piping, fittings, hanger support with U clamp, U bolt, threaded rods, nut, bolts & washers & structural pipe support shall be as per technical specification with all accessories as per approved drawings, specification and direction of the Engineer-in-Charge. ( Pipe - JINDAL Make) For aboveground Piping MS structural supports & Civil pedesgtral will be paid separately 150mm nominal dia
Supply, Installation, Testing & commissioning of Mild Steel black pipes, ERW, Heavy grade conforming to IS:1239 up to 150 mm dia. and IS:3589 for pipes above 150 mm dia. complete with fittings, reducers, tees, high tech supports, structural clamps such as rods, channels, angles, nuts, bolts & washers, as required to be firmly mounted on the steel structural members. 10 % of all the welded joints shall be done rediographically tested and 50% of the joints radiographed shall be the "Field Joints" & hydrostatic testing for 2 hours at 150% of the system pressure, hook-up etc. Painting for piping, fittings, hanger support with U clamp, U bolt, threaded rods, nut, bolts & washers & structural pipe support shall be as per technical specification with all accessories as per approved drawings, specification and direction of the Engineer-in-Charge. ( Pipe - JINDAL Make) For aboveground Piping MS structural supports & Civil pedesgtral will be paid separately 80mm nominal dia
Providing, laying, jointing and testing in excavated trenches the following sizes of ductile iron K-9 class , 6.8mm thickness pipes (6mtr per length) with accessories like fittings including tees, elbows, reducers, flanges, rubber gaskets, G.I. nuts, bolts and washers including excavation in all kind of soil, refilling, ramming, shoring, removing the excavated surplus material, providing adequate support to the pipe and making good the same complete as required. Rate shall include for dewatering necessary to execute the work. The pipe shall not be less than 1.0 m below ground level at any point. For Underground Piping , excavation and refilling will be paid separately 200mm nominal dia
Providing, laying, jointing and testing in excavated trenches the following sizes of ductile iron K-9 class , 6.8mm thickness pipes (6mtr per length) with accessories like fittings including tees, elbows, reducers, flanges, rubber gaskets, G.I. nuts, bolts and washers including excavation in all kind of soil, refilling, ramming, shoring, removing the excavated surplus material, providing adequate support to the pipe and making good the same complete as required. Rate shall include for dewatering necessary to execute the work. The pipe shall not be less than 1.0 m below ground level at any point. For Underground Piping , excavation and refilling will be paid separately 150mm nominal dia
Wrapping & Coating of Underground Pipe with pypcoat tape by thermo fusion process and surface preparation by applying cold primer (bitumen) 200mm nominal dia
Wrapping & Coating of Underground Pipe with pypcoat tape by thermo fusion process and surface preparation by applying cold primer (bitumen) 150mm nominal dia
Supplying, installing and commissioning of Cast iron wafer type lever operated butterfly valve conf. to IS: 13095, PN-16 with fittings, flanges, nut, bolts & washers, etc. MOC of the Body & disc shall be CI as per IS:210 FG200, EPDM / Neoprene seat, carbon steel (EN8) shaft and nylon / Teflon bearing. Valves exceeding 150 mm dia shall be gear operated. 150mm nominal dia
Supplying, installing and commissioning of Cast iron double flanged Sluice Valve conf. to IS: 14846, PN-16 with fittings, nut, bolts & washers, flanges etc. 200mm nominal dia
Supplying, installing, testing and commissioning of yard hydrant comprising of the following,Single headed hydrant valve as per IS 5290, made of Stainless Steel(SS 304) with 63 mm dia instantaneous out & 80 mm dia fanged inelt inlet,Blank cap , chain and hand wheel etc complete.
2 lengths of 15 Mtr long, 63mm dia RRL hose as per IS:636 Type B with instataneuos couplings and Hoses shall be stored in side the hose cabinet.
1 no. SS-304 short branch pipe with nozzle
Supplying, installing, testing and commissioning of S.S. orifice plate of 6 mm thk. For single hydrant.40mm
Supplying, installing and commissioning of fire brigade Siamese connection of 4 way with 4 nos. 63 mm dia. built - in Gun metal Non- return valves instantaneous coupling type arranged on 150 mm dia. Pipe manifold and connected to wet riser main. Qouted rate shall be included with C.I. Butterfly valve, C.I. Non-return valve etc. complete. Piping to be considered as per the approved route at site.
Supplying, installing and commissioning of fire brigade Breeching connection of 2 way with 2 nos. 63 mm dia. built - in Gun metal Non- return valves instantaneous coupling type arranged on 150 mm dia. Pipe manifold and connected to fire water tank. Qouted rate shall be included with C.I. Butterfly valve etc. complete.. (For fire tank filling)
Supplying, installing, testing and commissioning of 25mm dia GM air release valve with copper alloy globe valve.
SITC of Steel Structure for supporting
SUB-HEAD: III :FIRE EXTINGUISHER :- ABC Dry Powder type - 9 Kg. Capacity as per IS:15683
CO2 type - 4.5 Kg. Capacity as per IS:15683
Mechanical Foam - 9 Ltrs. Capacity as per IS:15683
Water Type CO2 type - 9 L. Capacity as per IS:15683
Supply & Installation of Sand buckets of 9L capacity as per IS:2546
Supply & Installation of M.S stand & canopy for housing 2 nos of sand buckets of 9L capacity
Providing & fixing of FRP MOBILE FOAM TROLLEY 200 Ltrs. Stored Pressure Type Controllable discharge mechanism applicable.
SUB-HEAD: IV :STATIONERY COMPLIENCE:- Making all liasoning work for getting provisional & Final CFO NOC, as filling necessary applications, submission of forms for approval to the municipal authorities, depositing and making channels for the necessary fees and other amounts as required for getting the premises / installations inspected and approved and all other formalities required till the sewer / storm water connection is obtained. All the expenses incurred in this regard shall be borne by the Contractor, except for the payments to be made for any security deposits which will be reimbursed on production of original voucher.
WATER SUPPLY, SANITARY & DRAINAGE WORKS: SUB-HEAD: I :SANITARY :- Supply,checking, storing and fixing S. S. sink, single bowl with tap point on wall / counter comprising of Concealed type brackets fixed to wall with adjustable clamp to push against counter rim,40 mm heavy plated C.P. waste coupling JAQUAR(ESSCO)-ALE-544NFT fitting without pop-up,with flexible PVC pipe with connector,CP swan neck sink faucet model JAQUAR(ESSCO)-MQT-522AKN Painting brackets with two coats of white enamel paint over one coat of primer,table mounted / wall mounted. Kitchen sink with drain board)(model :Nirali-olympia-bigor equivalent)
Supply, checking, storing and fixing in position European water closet comprising of Wall hung European W.C. MODEL JAQUAR(ESSCO)-MVS-WHT-951SPP in white colour, on approved type of chairs, flushing tank MODEL:JAQUAR(ESSCO)-WHE-WHT-183T as directed,C.P health faucet MODEL:JAQUAR(ESSCO)-ALE-ESS-583 with required length of flexible tube, clamp and bracket for fixing to wall,15 mm C.P. brass heavy quality angle stop cocks MODEL:JAQUAR(ESSCO)-MQT-526KN for flushing tank,C.P. brass 2-way bib cock MODEL:JAQUAR(ESSCO)-MQT-512ANKN ,Solid bakelite water closet cover and seat with C.P. hinges and rubber buffers,Fixing W.C. unit with brackets and accessories in position,Necessary pipe connection to PVC / PP / CI soil pipe,Painting bracket with two coats of white enamel paint over a coat of primer.
Supply, checking, storing and fixing in position European water closet comprising of Anglo Indian W.C. MODEL JAQUAR(ESSCO)-ECS-WHT-355PNPP in white colour, on approved type of chairs, flushing tank MODEL:JAQUAR(ESSCO)-WHE-WHT-183T as directed,C.P health faucet MODEL:JAQUAR(ESSCO)-ALE-ESS-583 with required length of flexible tube, clamp and bracket for fixing to wall,15 mm C.P. brass heavy quality angle stop cocks MODEL:JAQUAR(ESSCO)-MQT-526KN for flushing tank,C.P. brass 2-way bib cock MODEL:JAQUAR(ESSCO)-MQT-512ANKN ,Solid bakelite water closet cover and seat with C.P. hinges and rubber buffers,Fixing W.C. unit with Fixing accessories in position,Necessary pipe connection to PVC / PP / CI soil pipe,Painting bracket with two coats of white enamel paint over a coat of primer.
Supply, checking, storing and fixing Under Counter wash hand basin MODEL:JAQUAR(ESSCO)-MVS-WHT-801 ith ,32 mm heavy plated C.P. waste coupling JAQUAR(ESSCO)-ALE-544NFT fitting with pop-up,32 mm heavy plated C.P. bottle trap JAQUAR(ESSCO)-ALE-733ML 190X125 with cleaning eye with extension piece and wall flange,Painting brackets with two coats of white enamel paint over one coat of primer,CP Basin Faucet JAQUAR(ESSCO)-MQT-508KN with 15 mm C.P. brass heavy grade flexible inlet connection with C.P. nut (minimum length 450 mm) made to measure.
Supply, checking, storing & fixing CP Over Head shower MODEL:JAQUAR(ESSCO)-EOS-542A complete as per instructions of the engineer-in-charge.
Supply, checking, storing & fixing CP single lever wall mixer MODEL:JAQUAR(ESSCO)-ORB-105055K with Concealed body Shower Valve MODEL:JAQUAR(ESSCO)-ALE-055 complete as per instructions of the engineer-in-charge.
Supply, checking, storing & fixing C.P. brass towel ring MODEL:JAQUAR(ESSCO)-AEC-1121 Round to PVC cleats with C.P. brass screws including cutting and making good the walls wherever required .
Supply, checking, storing & fixing C.P. brass angle valve for basin & Sink MODEL:JAQUAR(ESSCO)-MQT-526KN, of approved quality conforming to IS:8931 for a) 15mm Nominal Bore
Supply, checking, storing & fixing C.P. brass Long Body bib cock MODEL:JAQUAR(ESSCO)-MQT-512KN of approved quality conforming to IS:8931. a) 15mm Nominal Bore
Supply, Checking, Storing and fixing vitreous Large flat back urinals Model No. JAQUAR-URS-WHT-132530 or Equivalent with Conceal automatic fushing system Model No. JAQUAR-SNR-CHR-51097G or Equivalent in white colour with concealed type wall hanger or special bracket in wall and hinged type C.P. dome gratings.C.P. flush pipes from auto flush, spreaders, full bore inlet caps as necessary made to measure.C.P. waste pipe and Speader under each urinal pan, leading to the CP bottle trap Model No.JAQUAR-ALD-CHR-769L300*190 or Equivalent below and painting with two coats of white enamel paints and cutting and making good the walls wherever require.
Supply, checking, storing & fixing straight/offset type Macfit single body push fit type WC Pan Connector Jaquar-ZPS-WHT-VB01 with factory supplied spring loaded seal guard with integrated single mould sealing fins made of flexible EVA Body, including bush/adaptor for use with CI Pipe as supplied with Pan Connector (For European water closet)
Installation testing and commissioning self contained pressure type water coolers suitable for operation on 230 voltage - 10% single phase AC supply and generally confirming to the requirements of IS :1476/78 having following nominal cooling capacity at an ambient temperature of 30 deg.c and drinking water inlet temperature of 35 deg c and drinking water outlet temperature of 13.5 deg. complete with compressor over head protector, thermostat and steel tank. 40 Ltr. Cooling and 80 Ltr Storage.Cap.(Make:Voltas,Blue Star,Usha)
Drinking Water RO - Providing & fixing Wall Mounted RO plant with UV Technology I.S.I marked,C.P brass push cock, inlet float valve with all plumbing and electrical accessories, inlet, outlet, overflow and PVC drain out connection. Flow-2 LPM(Make:Aquaguard,Eureka Forbes,Kent)
SUB-HEAD: II: SOIL WASTE AND VENT PIPE :- Providing and fixing PVC SWR Pipe confirming to IS 13592-92 TYPE B and fitting as per IS 14735-99 for SOIL & WASTE water discharge, including all fittings with and with out inspection doors, including supports brackets as per supplier specification and distance, cutting, chases /holes in walls/floors/slab etc. (Pipes to laid in Toilets, soil , waste , Rain , Vent for Shaft /External Area)(Make:Astral,Ashirvad,Suprime) 75 mm
Providing and fixing PVC SWR Pipe confirming to IS 13592-92 TYPE B and fitting as per IS 14735-99 for SOIL & WASTE water discharge, including all fittings with and with out inspection doors, including supports brackets as per supplier specification and distance, cutting, chases /holes in walls/floors/slab etc. (Pipes to laid in Toilets, soil , waste , Rain , Vent for Shaft /External Area) (Make:Astral,Ashirvad,Suprime) 110 mm
Providing and fixing PVC SWR Pipe confirming to IS 13592-92 TYPE B and fitting as per IS 14735-99 for SOIL & WASTE water discharge, including all fittings with and with out inspection doors, including supports brackets as per supplier specification and distance, cutting, chases /holes in walls/floors/slab etc. (Pipes to laid in Toilets, soil , waste , Rain , Vent for Shaft /External Area )(Make:Astral,Ashirvad,Suprime) 150 mm
Providing and fixing PVC Agri 6Kg/cm2 and fitting for SOIL & WASTE water discharge, including all fittings with and with out inspection doors, including supports brackets as per supplier specification and distance,cutting, chases/holes in walls/flors/slab etc. (Pipes to laid in Toilets)(Make:Astral,Ashirvad,Suprime) 50mm
Providing and fixing PVC traps of self cleansing design with water seal not less than 50mm with or without vent, including setting the trap in 1:2:4 cement concrete etc. complete. The trap shall be `P' type as required. Trap with 100 mm inlet and outlet 75mm/100mm dia.(Make:Astral,Ashirvad,Finolex)
Providing and fixing in position Multi Floor Trap/Plain Floor Trap self cleansing design moulded or fabricated with 50 mm water seal conforming to IS:14735-90 including setting the trap in 1:2:4 cement con'crete etc. (Make:Astral,Ashirvad,Finolex) 100mm Outlet
Supply , installation , testing and commissioning rain water Sidewall Parapet CI Body With Aluminium Grate With 4 SS Screw Drains ,size as per drawing required depth with Making Khurra with Proper water proofing and fixing the fittings (Horizontel/vertical arrangment grating) complete as required.(Make:Neer,Weimer) 300x 300 mm (75mm outlet pipe dia )
Supply , installation , testing and commissioning rain water Sidewall Parapet CI Body With Aluminium Grate With 4 SS Screw Drains ,size as per drawing required depth with Making Khurra with Proper water proofing and fixing the fittings (Horizontel/vertical arrangment grating) complete as required.(Make:Neer,Weimer) 450x 450 mm (100mm outlet pipe dia )
SUB-HEAD: III: INTERNAL WATER SUPPLY :- Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. For Hot & Cold Water Lines ( Domestic ) (Inside Toilet)(Make:Astral,Ashirvad,Finolex) 15 mm nominal outer dia Pipes ( SDR 11 )
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. For Hot & Cold Water Lines ( Domestic ) (Inside Toilet)(Make:Astral,Ashirvad,Finolex) 20 mm nominal outer dia Pipes ( SDR 11 )
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. For Hot & Cold Water Lines ( Domestic ) (Inside Toilet) For Hot & Cold Water Lines ( Domestic & Flushing ) (In shaft & Terrace & Exposed On wall) (Make:Astral,Ashirvad,Finolex) 25 mm nominal outer dia Pipes ( SDR 11 )
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. For Hot & Cold Water Lines ( Domestic ) (Inside Toilet) For Hot & Cold Water Lines ( Domestic & Flushing ) (In shaft & Terrace & Exposed On wall) (Make:Astral,Ashirvad,Finolex) 32 mm nominal outer dia Pipes ( SDR 11 )
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. For Hot & Cold Water Lines ( Domestic & Flushing ) (In shaft & Terrace & Exposed On wall) 40 mm nominal outer dia Pipes ( SDR 11 )
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. For Hot & Cold Water Lines ( Domestic & Flushing ) (In shaft & Terrace & Exposed On wall) 50 mm nominal outer dia Pipes ( SDR 11 )
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC high bonded solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(The pipe length inserted in the fitting shall not be measured for payment) For Cold Water Lines (Inside Shaft & Terrace & Riser)(Make:Astral,Ahirvad,Finolex) 65 mm nominal outer dia Pipes ( SCH 40 )
Providing, fixing and testing of heavy quality CPVC BALL Valves of 15 Kg / sqcm pressure with all necessary unions and nipple collars fixing on CPVC lines.(Make:Astral,Ahirvad,Finolex) 25mm dia
Providing, fixing and testing of heavy quality CPVC BALL Valves of 15 Kg / sqcm pressure with all necessary unions and nipple collars fixing on CPVC lines.(Make:Astral,Ahirvad,Finolex) 32mm dia
Providing, fixing and testing of heavy quality CPVC BALL Valves of 15 Kg / sqcm pressure with all necessary unions and nipple collars fixing on CPVC lines.(Make:Astral,Ahirvad,Finolex) 50mm dia
Supplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.(Make:Sant,Zoloto,leader) BUTTERFLY VALVE (MANUAL) with C I body SS disc nitrile sheet & O - ring & PN 16 pressure rating as specified. 65 mm dia.
Providing and fixing Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for cold / hot water circulation including insulation as specified.(Make:Sant,Zoloto,leader) 65 mm dia.
SUB-HEAD: IV: EXTERNAL WATER SUPPLY,DRAINAGE AND STORM WATER :- Providing & laying UPVC pressure pipes of 10Kg/Sq.cm pressure rating class V (IS : 4985-2000) including fittings, tees, bends, clamps, coupling and adaptors supports, and jointing with solvent joint, testing and necessary earth work in excavation, backfilling, disposal of surplus earth with a lead up to 100m complete, compaction and consolidation Including sand bedding all around UPVC pipe & fittings and thrust blocks at bends as per standard design. 25 mm outer dia
Providing & laying UPVC pressure pipes of 10Kg/Sq.cm pressure rating class V (IS : 4985-2000) including fittings, tees, bends, clamps, coupling and adaptors supports, and jointing with solvent joint, testing and necessary earth work in excavation, backfilling, disposal of surplus earth with a lead up to 100m complete, compaction and consolidation Including sand bedding all around UPVC pipe & fittings and thrust blocks at bends as per standard design. 40 mm outer dia
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm outer dia
Providing laying (to level or slopes) and jointing reinforced concrete Light duty non-pressure pipes I.S. class NP2 of the following internal diameter with collars and butt ends prepared for collar joints including testing of joints complete.(C) 250mm (upto 10 ton)
Providing, laying, jointing and testing heavy quality DWC (Double wall Corrugated ) under ground application pipes for Sewer and strom line with Snap-Fit Coupler with Rubber Ring / In-line Socket Molded Coupler / Socket-Spigot Arrangement fittings of SN8 class of approved make laid to required alignment and slope trenches inclusive of excavation in all soil types, bailing or pumping out water from trenches, shoring, whenever necessary testing, refilling, in layers, ramming & consolidation, removing away the surplus earth & spoils, dumping it on site or carting away to lead of 100 meters as directed incl. 150 mm dia
Providing, laying, jointing and testing heavy quality DWC (Double wall Corrugated ) under ground application pipes for Sewer and strom line with Snap-Fit Coupler with Rubber Ring / In-line Socket Molded Coupler / Socket-Spigot Arrangement fittings of SN8 class of approved make laid to required alignment and slope trenches inclusive of excavation in all soil types, bailing or pumping out water from trenches, shoring, whenever necessary testing, refilling, in layers, ramming & consolidation, removing away the surplus earth & spoils, dumping it on site or carting away to lead of 100 meters as directed incl. 200 mm dia
Providing, laying, jointing and testing heavy quality DWC (Double wall Corrugated ) under ground application pipes for Sewer and strom line with Snap-Fit Coupler with Rubber Ring / In-line Socket Molded Coupler / Socket-Spigot Arrangement fittings of SN8 class of approved make laid to required alignment and slope trenches inclusive of excavation in all soil types, bailing or pumping out water from trenches, shoring, whenever necessary testing, refilling, in layers, ramming & consolidation, removing away the surplus earth & spoils, dumping it on site or carting away to lead of 100 meters as directed incl. 250 mm dia
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes /UPVC /DWC Pipes including bed concrete as per standard design b)150 mm dia diameter
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes /UPVC /DWC Pipes including bed concrete as per standard design c) 200mm dia diameter
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes /UPVC /DWC Pipes including bed concrete as per standard design d) 250mm dia diameter
Providing and fixing S.W. gully trap with C.I. grating brick masonry chamber and water tight C.I. cover with frame of 300mm x 300mm size (inside) with standard weight.(i) Square mouth traps. (A) 100mm x 100mm size P type. (upto 10 ton)
Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1-cement :2-coarse sand : 4-graded stone aggregate 20mm nominal size) foundation concrete 1:3:6 mix (1-cement : 3- coarse sand :6-Brick bats 40 + 50mm size) inside plastering 15mm thick with Cement Mortar 1:5 (1-Cement : 5-coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1-Cement :2-Coarse sand :4-stone aggregate 20mm nominal size) finished smooth complete including curing and festing (i) Inside size 900mm x 800mm and 0.9M. deep including C.I. cover with frame size 560mm diameter total weight of cover and frame to be not less than 128 kgs. (Wt. of cover 64 Kg. and Wt. of frame 64 Kg.)(A) With 230mm thick walls of brick msonry using brick having crushing strength not less than 35Kg. / Sq.cm. in Cement Mortar 1:5 (1- Cement: 5-Coarse sand) (1) A type depth 0.90 Metre for 150mm diameter sewer.
Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1-cement :2-coarse sand : 4-graded stone aggregate 20mm nominal size) foundation concrete 1:3:6 mix (1-cement : 3- coarse sand :6-Brick bats 40 + 50mm size) inside plastering 15mm thick with Cement Mortar 1:5 (1-Cement : 5-coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1-Cement :2-Coarse sand :4-stone aggregate 20mm nominal size) finished smooth complete including curing and festing (i) Inside size 900mm x 1200mm and 1.5M. deep including C.I. cover with frame size 560mm diameter total weight of cover and frame to be not less than 128 kgs. (Wt. of cover 64 Kg. and Wt. of frame 64 Kg.)(A) With 230mm thick walls of brick msonry using brick having crushing strength not less than 35Kg. / Sq.cm. in Cement Mortar 1:5 (1- Cement: 5-Coarse sand) (2) B type depth 1.50 Metre for 150mm diameter sewer.
Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1-cement :2-coarse sand : 4-graded stone aggregate 20mm nominal size) foundation concrete 1:3:6 mix (1-cement : 3- coarse sand :6-Brick bats 40 + 50mm size) inside plastering 15mm thick with Cement Mortar 1:5 (1-Cement : 5-coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1-Cement :2-Coarse sand :4-stone aggregate 20mm nominal size) finished smooth complete including curing and festing (i) Inside size 900mm x 1200mm and 1.5M. deep including C.I. cover with frame size 560mm diameter total weight of cover and frame to be not less than 128 kgs. (Wt. of cover 64 Kg. and Wt. of frame 64 Kg.)(A) With 230mm thick walls of brick msonry using brick having crushing strength not less than 35Kg. / Sq.cm. in Cement Mortar 1:5 (1- Cement: 5-Coarse sand) (3) C type depth 2.25 Metre for 150mm diameter sewer. (I) Extra rate for constructing B.B. masonry for every additional depth of 0.1M. or Part thereof over item No.24.27 (I) for depth from 0.9M to 1.5M.
Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1-cement :2-coarse sand : 4-graded stone aggregate 20mm nominal size) foundation concrete 1:3:6 mix (1-cement : 3- coarse sand :6-Brick bats 40 + 50mm size) inside plastering 15mm thick with Cement Mortar 1:5 (1-Cement : 5-coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1-Cement :2-Coarse sand :4-stone aggregate 20mm nominal size) finished smooth complete including curing and festing (i) Inside size 900mm x 1200mm and 1.5M. deep including C.I. cover with frame size 560mm diameter total weight of cover and frame to be not less than 128 kgs. (Wt. of cover 64 Kg. and Wt. of frame 64 Kg.)(A) With 230mm thick walls of brick msonry using brick having crushing strength not less than 35Kg. / Sq.cm. in Cement Mortar 1:5 (1- Cement: 5-Coarse sand) (3) C type depth 2.25 Metre for 150mm diameter sewer. (II) Extra rate for constructing B.B. masonry for every additional depth of 0.1M. GR Part thereof over item No.24.27 (I) for depth from 1.50M. to 2.25M.
Providing and fixing cast iron steps of size 500mm x 150mm x 22.5mm and painting with two coats of Anti-corrosive paint etc. complete.
Constructing Brick masonry road gully chamber 500mm x 450mm x 600mm including 500mm x 450mm C.I. horizontal grating wih frame complete. (more than 10 ton)
Constructing brick masonry road gully chamber 1100mm x 775mm including 500mm x 450mm (C.I. horizontal grating with frame and vertical grating complete.) (more than 10 ton)
Constructing brick masonry chamber for underground C.I. Inspection chamber and bends with briocks having croshing strength not less than 35Kg. Cm2 in C.M. 1:5 C.I. cover with frame (Light duty) 455mm x 610mm intenal dimensions total weight of cover with frame to be not less than 38Kg. (Wt. of cover 23 Kg.) and Wt. of frame 15Kg. ) (R.C.C. top slabe with 1:2:4 mix (1-cement :2- coarse sand :4-graded stone aggregate 20mm size) foundation concrete 1:5:10 inside plaster 15mm thick with cement mortar 1:3 finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete.(i) Inside dimensions 455mmx 610mm and 450mm deep for single pipe line. (more than 10 ton)
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, up to 90 metre depth below ground level. All type of soil 300 mm dia metre
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia
Providing and fixing factory made precast RCC perforated drain covers,having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineerin-charge.
HYDROPNEUMATIC SYSTEM AND VARIOUS PUMPS Variable Speed Hydro-booster System for domestic water supply : Compact self contained Hydro-booster system comprising of following : In-line, vertical multistage, centrifugal clear water pumps with SS-316L /304 casing, S.S 3I6L impeller and SS-304/316 shaft, SS-316L/C.I. Base CED coating & head TEFC IE4/IE5 magnetic motor (IE5 is preferable motor for Suitable duties, if duties is not available in IE5 motor then you can quote pump with IE4 motor) with mechanical seal with Company fitted with company compliance certificate. Vendor to submit performance curves and technical catalogue with all GA Drawing of the proposed model for review and information.Panel mounted PLC and HMI Based multi pump controller with large graphical display with VGA 240 x 320 pixels and variable frequency drive (VFD) integrated in a Panel/Inbuilt with pump motor with IP54 class with pressure sensor transmitter (each pump each VFD), diodes to indicate pump ready, pump running and fault and capable to communicate with other controllers following MODBUS-RTU or BACNET Class-2 protocol through RS485 port. All alarms should be displayed in the controller. System should be equipped with dry running protection by both, reputed make Float (NO/NC) having 20 Mtrs Submersible Cable installed in the Tank & 0-10V DC Device installed on Suction Header. Indication of all type of faults / on-off status / electrical parameters shall be available on panel and central IBMS monitors. On-off operation for all pumps shall be available on BMS system.Global / Equivalent Make Pre-charged diaphragm pressure vessel with 3 years warranty from manufacturing date and company tested replaceable membrane, charging connection, connected to outlet header with necessary flanges, gaskets, isolating valves, nuts/bolts etc. complete (size of pressure vessel shall be following capacity or as per manufacturer recommendation). Vessel Shall be pre-charged with Nitrogen as per respective Pump Head. Each Vessel shall be installed with 2 1/2" SS 304 Glycerine Filled Manometer on Top.Set of accessories such as SS 304 / MS with CED Coated headers for suction and discharge, control valves, non return valves, pressure transducers, pressure gauge, inter connecting power and control cabling etc. complete. Capacity of Pilot pump (Working) - 200 LPM Capacity per pump - 300 LPM Head - 50m Pressure vessel - Min. 100 liters or as per manufacturer recommendation 1 Set = 3 Nos. Pump (1Pilot Working + 1 Working + 1 Standby - cascade operation) Suction head - flooded positive suction Supply, Installation, testing & commissioning
Supply, installation, testing & commissioning of Submersible Multi stage borewell pumps (Sutable for 150mm dia )connected to submersible motor (The motor shall be IE3 watertight according to IEC class IP 68, and incorporate class F, insulation materials to withstand a continuous operating temperature of 155 deg C) for 415 + 10% volts, 3 phase, 50 cycles A.C. power supply with mechanical seal, pump connector unit Or Auto Coupling with rubber diaphragm and bend, vertical discharge pipe,Control Panel,Cable,Column pipe etc complete to the entire satisfaction of the Engineer-in-charge. Flow-30000 Ltr/Hr Head-50m
ELECTRICAL WORKS: Providing and erecting ISI Marked 3core 185 Sq.mm XLPE insulated 11 KV armoured cable Aluminium conductor to be laid on wall with clamps or in provided cable trench / pipe approved manner as directed.
Providing and erecting cable end terminatation kit, heat shrinkable Push on type Densons/ Raychem/ Elastimold make suitable for 11 KV XLPE cable 3core 185 Sq.mm (A) Outdoor type
Providing and erecting cable end terminatation kit, heat shrinkable Push on type Densons/ Raychem/ Elastimold make suitable for 11 KV XLPE cable 3core 185 Sq.mm (B) Indoor type
Supply, Installation Testing and commissioning of 11KV/433V 400KVA Outdoor Type USS with 400A HT VCB Section, 750 KVA Distribution Transformer (DRY TYPE WITH OFF LOAD TAP LINKS, TAP OF +/- 7.5 % IN STEP OF 1.5) Section and LT Section with 800A FP MOTORISED MICROPROCESSOR BASED MCCB - 50KA Section complete as per detailed Technical Specifications
SUB-STATION ACCESSORIE AS PER LOCAL NORMS - Safety Signages, Fire Extinguisher, First Aid Kits, Hand Glowes, Rubbers Mats etc
Providing & erecting weather proof, dust & vermin proof, floor mounted front operated indoor type cubical panel board having IP-64 protection made from 14 SWG thick CRC M.S. sheet for outer body & doors, 16 SWG thick CRC M.S.sheet for internal partitions with necessary supporting angles, flats including cutting, bending, drilling, welding, riveting with internal partitions & cable alley as per requirements & instruction of engineer-in-charge with erection, supplied switch gears, BUSBARS, with suitable size of inter connecting PVC copper wire / copper-aluminium strips, rubber grommets, rib, bakelite control fuses for measuring instruments, earth bus & earth bolts, foundation flange - bolts-base Plates, sufficient nos. of hinged doors, handles with locking arrangement and rubber gasket complete. The Panel shall be painted with epoxy powder coating. (The rates includes the cost of switchgears, bus bars, inter connecting mains & Copper Aluminium strips, meters, Fuses etc. The dimension shall be measured excluding base beams) The panel shall be supplied with following approved manufacturers as per attached SLD - MAIN LT PANEL (as per attached Single Line diagram)
2X250KVA DG AUTO SYCH, AUTO LOAD SHARING PANEL (Specification as above & as per attached Single Line diagram)
Dormatory - Main LT Panel (Specification as above & as per attached Single Line diagram)
Ware House - Main LT Panel (Specification as above & as per attached Single Line diagram)
Service Station - Main LT Panel (Specification as above & as per attached Single Line diagram)
Admin - Main LT Panel (Specification as above & as per attached Single Line diagram)
Charging Station - Main LT Panel (Specification as above & as per attached Single Line diagram)
CNG-Diesel Pump : Main LT Panel (Specification as above & as per attached Single Line diagram)
External Lighting Panel (Specification as above & as per attached Single Line diagram)
High Mast - Lighting Control Panel (Specification as above & as per attached Single Line diagram)
185KVAR APFCR PANEL (Specification as above & as per attached Single Line diagram)
METER PANEL FOR COMMERCIAL BLOCK (Specification as above & as per attached Single Line diagram)
Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, confirming to IS 13032 and BS 5486-1986 without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used) - Three phase 8 way SS Double door for horizontal single phase outgoing
Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, confirming to IS 13032 and BS 5486-1986 without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used) - (D) Single phase 6 way SS Double door
Miniature circuit breaker single pole 6A to 32A suitable to operate on 240 V A.C. system and having breaking capacity 10 KA to be erected in existing box. confirming to IS 8828/1996 with ISI Mark - SP MCB
Providing & erecting 240 V MCB double pole switch for motor & inductive load (C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following capacity 6 to 32 Amp. - DP MCB
Providing & erecting 240 V MCB double pole switch for motor & inductive load (C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following capacity 40Amp. - DP MCB
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity 6 to 32 Amp.
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity 40 Amp.
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity 63 Amp.
Approved make ELCBs / RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 6 KA and suitable for operation on single phase 240 V. having characteristic of quick action & tripping with all advance feature & do not incorporate any electronic component. for following Max. rating erected as directed 25 Amps.DP
Approved make ELCBs / RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 6 KA and suitable for operation on single phase 240 V. having characteristic of quick action & tripping with all advance feature & do not incorporate any electronic component. for following Max. rating erected as directed 40 Amps.DP
Approved make ELCBs / RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 6 KA and suitable for operation on single phase 240 V. having characteristic of quick action & tripping with all advance feature & do not incorporate any electronic component. for following Max. rating erected as directed 63 Amps.DP
Supplying & erecting approved make RCCB + MCB (Electro magnetic type only) working on residual current device having 6 KA short circuit breaking capacity and 30 mAmp. Sensitivity & 30 mili sec. tripping time conforming to IS 12640 test knob facility trip free mechanism operating for rated leakage at nominal ten volt, complete erected including all materials lugs screws etc. completed. 32A DP
Sheets steel powder coated enclosure suitable for incorporating One/Two nos. MCB.
Surge Protection Devices (SPD) Supplying, Assembling, levelling, connecting & testing following VSPs etc in boards as specified in 8.1, 8.2 & 8.3 1.4KV Protection level FP ,Class 'I', (Imax-40KA, 8/20µS) LEGRAND Cat no. 3938 or Equivalent
1.2KV Protection level FP, Class 's', (Imax-15KA, 8/20µS) LEGRAND Cat no.3943 or Equivalent
1.2KV Protection level DP, Class 's', (Imax-15KA, 8/20µS) LEGRAND Cat no. 3941 or Equivalent
Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 35 KA. at 415 V. having normal current rating up to 125A. with Fixed thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections & complete erected in existing 16 G.M.S. housing. ICS=100% of ICU only with Sheet metal Enclosure
Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 35 KA. at 415 V. having normal current rating up to 250A. with Fixed thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections & complete erected in existing 16 G.M.S. housing. ICS=100% of ICU only with Sheet metal Enclosure
Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 35 KA. at 415 V. having normal current rating up to 400A. with Fixed thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections & complete erected in existing 16 G.M.S. housing. ICS=100% of ICU only with Sheet metal Enclosure
Providing and erecting metallic vitrified danger notice board for MEDIUM VOLTAGE installation to be erected as per IS.
Providing and erecting metallic vitrified danger notice board for HIGH VOLTAGE installation to be erected as per IS.
Supplying & erecting approved make Digital time switch having lithium cell 6 years operative and operate battery backup 1 channel day clock with 14 memory programme, suitable to operate on 240V + 5%, 16A with, floating contacts Minimum switching setup time 1 minimum & LCD display. Also comprised permanent ON/OFF switching. Programming switches & housed in fire proof thermoplastic enclosure & transparent cover erected as required with necessary connection erected as directed.
Providing and erecting approved make light control unit suitable to operate on 230V +20% having ON/OFF delay time of 30-50 seconds and having facility for Auto/manual system having two LDR lens to intensity light having capacity of 5A complete erected on section pillar with pipe and stand. Supplying & erecting power contactor for time switch complete erected as per direction Cat III 4 pole 440V 40 Amp.
Making trench in soft soil of suitable width of 90 cms deep for laying cable or locating the fault all over the run and backfilling the same and making the surface as normal ground.
Covering of cable with second class bricks or cement tiles laid cover the cable crosswise & also on both sides with covering of 7. 5 Cms. layer of sand above & below cable (16 bricks per meter)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cables.(a) 4 core 2.5 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cables.(a-1) 4 core 4 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cables.(B) 4 core 6 Sq. mm
Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables(c) 4 core 10 Sq. mm
Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables(d) 4 core 16 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables (A) 3 1/2 core 25 Sq. mm ( 16 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables (A-1) 3 1/2 core 35 Sq. mm ( 16 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables (B) 3 1/2 core 50 Sq. mm ( 25 Sq.1/2 mm core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables(C) 3 1/2 core 70 Sq. mm ( 35 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables (D) 3 1/2 core 95 Sq. mm ( 50 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables (E) 3 1/2 core 120 Sq. mm ( 70 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables (G) 3 1/2 core 185 Sq. mm ( 95 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables (H) 3 1/2 core 240 Sq. mm( 120 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables (I) 3 1/2 core 300 Sq.mm ( 150 Sq. mm 1/2 core)
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. Solderless crimping type Copper lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (E) 4 core 4 Sq. mm / 4 core 2.5 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. Solderless crimping type Copper lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (E) 4 core 6 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (E) 4 core 10 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (A) 3 & 1/2 core 25 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (B) 3 & 1/2 core 35/50 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (C) 3 & 1/2 core 70 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (D) 3 & 1/2 core 95 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (E) 3 & 1/2 core 120 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (G) 3 & 1/2 core 185 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (H) 3 & 1/2 core 240 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (I) 3 & 1/2 core 300 Sq. mm
Supplying & laying under floor pregalvanised corrosion proof rectangular sheet steel cable trunking of 1.6 mm thick having with stand point load up to 1.33 Ton & free from seepage of concrete of screed water having following size of dimensions and No of compartments (W x D x T) : 150mm x 38mm x 1.6mm with Three Compartments
[C] G.I. Junction cross over box for metal / Al. trunking with duct entry 25mm x 38mm size having epoxy powder coated trap lead with corrosion & rust free having load bearing capacity of 3.6 TONS with adjustable levelling screw of following size.150mm x 150mm x 60/75 mm depth
[C] G.I. Junction cross over box for metal / Al. trunking with duct entry 25mm x 38mm size having epoxy powder coated trap lead with corrosion & rust free having load bearing capacity of 3.6 TONS with adjustable levelling screw of following size.300mm x 300mm x 60/75 mm depth
Supplying and erecting approved make GRP Perforated type Cable Tray Material – Corrosion Resistant Polyester Flame Retardant U.V. Stabilized Resin System - Manufactured from Pultruded Sections- Polyester Resin System, Glass Content : 55 – 60 % - - Standard Length : 3000mm- Support Span – 1500mm, Deflection L/200 - Specification NEMA FG1 1993- UV Resistant - Flame Retardant – IS 6746 - Appendix K/UL 94, Very Low Flammability - Specification Followed NEMA FG1 1993 Oxygen Index – Minimum 30% as per ASTM D 2863 - Flame Spread (Extent of Burning) – 20mm as per Standard ASTM D 635 - Tensile Strength – 4000 – 8000 Kg/Cm2 as per Standard ASTM D 638 - Flexural Strength – 2500 – 10000 Kg/Cm2 as per Standard ASTM D 790- Izod Impact Strength – 130 Kg/Cm2 as per Standard ASTM D 256- Compressive Strength – 2500 – 5000 Kg/Cm2 as per Standard ASTM D 695- Barcol Hardness – 50 – 65 (D) Width - 150mm, Pultruded “C” Channel with 30mm Sides 3mm Thickness, Loading 15 Kg./Mtr.
(E) Width - 200mm, Pultruded “C” Channel with 40mm Sides 4mm Thickness, Loading 25 Kg./Mtr.
(F) Width - 300mm, Pultruded “C” Channel with 50mm Sides 4mm Thickness, Loading 30 Kg./Mtr.
Fabrication : Supplying , fabricating and installation of various sizes clamps for cable tray supports using available M.S. sections & rod as per drawings or instructions of engineer in charge or consultant including applying zinc chromate yellow oxide and two to three coats of required enamel paints with anchor fasteners etc.
HEAT / FIRE RESISTANT COATING OF CABLE Supply and application of intumescent based coating on cables/ cable tray using CP 678 firestop cable coating of HILTI make or equivalent. The coating shall have a density in the range of 1.2 to 1.4 Kg/ L. The coating shall be non-toxic, asbestos and halogen free and shall have good mechanical strength. The coating shall comply with IEC 332 part 3 (1992).
Point wiring for Light Point / Bell with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of pipe to be erected concealed in/ on surface on wall/ceiling complete with 6A Modular type switch / bell push & accessories and earth continuity of following type, erected on PVC / Metallic box, single mounting base frame covered with textured/metallic front plate modules erected on / in wall / ceiling as per pipe erected, with necessary Lamp holder/ceiling rose / H.D.Connector as directed.with medium class Rigid PVC pipe and accessories
Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size in (a) with medium class Rigid PVC pipe and accessories Wire : (a) 2 wire 1.5 sq. mm
Additional Wire : Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size in (a) with medium class Rigid PVC pipe and accessories Wire : (b) 2 wire 2.5 sq. mm
Point wiring for secondary light point with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of pipe to be erected concealed in / flushed on wall/ceiling, complete with earth continuity and necessary connection with primary light with accessories erected on Metal / PVC box covered with 3 mm thick PC(Polycarbonet) / Acrylic sheet for open / concealed wiring. with necessary Lamp holder / ceiling rose / H.D.Connector as directed. (a) with medium class Rigid PVC pipe and accessories
Point wiring for Two Way Controlled Light Point with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (green) both are of .ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of pipe to be erected concealed in / flushed on wall/ceiling ,complete with 6A Modular type switches and following type of accessories erected on PVC / Metallic box, single mounting base frame covered with textured / metallic front plate modules erected on / in wall / ceiling as per pipe erected. with necessary batten/angle holder or ceiling rose or H.D.Connector as directed. (a) with medium class Rigid PVC pipe and accessories
Point wiring for FAN with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (Green) both are of .ISI marked 1.1 KV Grade FRLS PVC insulated multistrand copper wires, in following type of pipe to be erected concealed in / flushed on wall/ceiling complete with 6A Modular type switch and hum free EME four or more step type electronic fan regulator with separately mounted and accessories with earth continuity of following type erected on PVC / Metallic box, single mounting base frame covered with textured/metallic front plate modules erected on / in wall / ceiling as per pipe erected. with necessary ceiling rose / H.D.Connector as directed. (a) with medium class Rigid PVC pipe and accessories
Point wiring for Looped Plug with 6A Modular type switch & 5 pin socket erected on PVC / Metallic box, single mounting base frame covered with textured / metallic front plate modules erected on / in wall / ceiling with following type accessories
Do - As - Above but for 6 A x 5 pin 250 Volt switched socket outlet point at convenient location. ( Plug & Switch can be together or at different location )
Point wiring for Individual Plug with & earthwire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of to be erected concealed in / on surface of wall / ceiling complete with Modular type switch & 5 pin Plug erected on PVC / Metallic box covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected with following type of accessories. [II] For 6/16A Plug with 2-2.5 sq.mm Cu. Wire (a) with medium class Rigid PVC pipe and accessories
Point wiring for Individual Plug with & earthwire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of to be erected concealed in / on surface of wall / ceiling complete with Modular type switch & 5 pin Plug erected on PVC / Metallic box covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected with following type of accessories. [III] For 16A Plug with 2-4 sq.mm Cu. Wire (a) with medium class Rigid PVC pipe and accessories
Providing and erecting 1.6 - 1.8 mm thick FIA approved and ISI mark (embossed) RIGID PVC PIPES of following size complete erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following type of erection.2) For erecting concealed in RCC / Brick wall/slab or Open along with continuous fish wire to draw mains, laid in approved manner with plastering by cement mortar & finishing the surface to match the wall/ceiling. Supply and laying of 25 mm rigid PVC pipe of 1.6-1.8 mm thickness
Providing and erecting 1.6 - 1.8 mm thick FIA approved and ISI mark (embossed) RIGID PVC PIPES of following size complete erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following type of erection.2) For erecting concealed in RCC / Brick wall/slab or Open along with continuous fish wire to draw mains, laid in approved manner with plastering by cement mortar & finishing the surface to match the wall/ceiling. Supply and laying of 32 mm rigid PVC pipe of 1.6-1.8 mm thickness
Providing and erecting 1.6 - 1.8 mm thick FIA approved and ISI mark (embossed) RIGID PVC PIPES of following size complete erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following type of erection.2) For erecting concealed in RCC / Brick wall/slab or Open along with continuous fish wire to draw mains, laid in approved manner with plastering by cement mortar & finishing the surface to match the wall/ceiling. Supply and laying of 40 mm rigid PVC pipe of 1.6-1.8 mm thickness
Providing & laying ISI marked Rigid PVC pipe having 6Kg / cm2 (Class-3) to be erected at road crossing on or floor as directed for laying of cable. The pipes as following size of dia & weight per 6 mtr. (B) 50 mm Dia. (2.5Kg/6RMT)
Providing & laying ISI marked Rigid PVC pipe having 6Kg / cm2 (Class-3) to be erected at road crossing on or floor as directed for laying of cable. The pipes as following size of dia & weight per 6 mtr. (D) 75 mm Dia (5.5 Kg / 6RMT)
Providing & laying ISI marked Rigid PVC pipe having 6Kg / cm2 (Class-3) to be erected at road crossing on or floor as directed for laying of cable. The pipes as following size of dia & weight per 6 mtr. (E) 90 mm Dia (8.0 Kg / 6RMT)
Supplying & erecting Electronic Type Cordless Call Bell erected on PVC/Metal board having portable bell push working on D.C. & bell on 230V A.C. supply with cells / battery
Computer : Power Plugs 1 no. universal plug-switch combined + 1 Nos swithc for Below table 2 nos. 6A 5 pin Plug as below Point wiring for Looped Plug with 6A Modular type switch & 5 pin socket erected on PVC / Metallic box, single mounting base frame covered with textured / metallic front plate modules erected on / in wall / ceiling with following type accessories Cat. III Point wiring for Individual Plug with & earthwire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of to be erected concealed in / on surface of wall / ceiling complete with Modular type switch & 5 pin Plug erected on PVC / Metallic box covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected with following type of accessories. [I] For 6A Plug with 2-1.5 sq.mm Cu. Wire (Car.iii) + [II] For 16A Plug with 2-2.5 sq.mm Cu. Wire (Car.iii)
Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected in / on wall / ceiling with following sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size : 4 wire 4 sq. mm
Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected in / on wall / ceiling with following sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size : 4 wire 6 sq. mm
Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected in / on wall / ceiling with 2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size : 4 wire 10 sq. mm
Providing & erecting Approved make Ceiling Fan with double ball bearing ISI mark with Condenser 230 volt A.C.50 Hz 1200 mm sweep complete having 3 blades aluminium body and blade sets having ornamental design shanks , canopy & 30 cms. down rod erected with 24/0.2, 3 core flexible wire with earthing. It should be BLDC motor -5, 320RPM, 30-35W 5-Star rating Power saving Fan
Supplying and erecting 19 / 20 mm. nominal bore Medium Class M.S. Pipe down rod erected duly painted for fan complete with necessary 24/ O.20, 3 core flexible wire with earthing.
Supplying & erecting approved make low noise decorative exhaust fan having size 200mm with 1350 RPM with square frame ABS body with inbuilt lowers & square frame.
Supplying & erecting single phase approved make industrial exhaust fan suitable for medium duty ring mounted low noise operation suitable for medium duty having following dia size and maximum speed in RPM [C] 380 mm dia 1400 RPM
Supplying & erecting single phase approved make industrial exhaust fan suitable for medium duty ring mounted low noise operation suitable for medium duty having following dia size and maximum speed in RPM [D] 450 mm dia 900 RPM
Supply,installation, testing and commisioning of Internal light fixtures of 1200mm long LED Tube light (20W) with 110LPW white color Aluminum extruded body and milky white diffuser.Make : Trilux, Wipro, Philips
Supply,installation, testing and commisioning of Internal light fixtures of 1200mm long LED Tube light (20W) IP-65 with 110LPW white color Aluminum extruded body with PC transperant diffuser diffuser.Make : Trilux, Wipro, Philips
Supply,installation, testing and commisioning of Internal light fixtures of 600mm long LED Tube light (14W) with 110LPW white color Aluminum extruded body and milky white diffuser.Make : Trilux, Wipro, Philips
Supply,installation, testing and commisioning of IP-65 Surface Mounted 10W LED down light with White Aluminum dia cast, powder coated housing, reflector, PMMA Deep Down LG7 Diffuser cover with LED lamp with inbuilt driver and driver. LUMEN EFFICACY >110lm/w, PF >0.90, THD <20%, CCT 6000K, Make : Trilux, Wipro, Philips
Supply,installation, testing and commisioning of IP-65 Surface Mounted 16W LED down light with White Aluminum dia cast, powder coated housing, reflector, PMMA Deep Down LG7 Diffuser cover with LED lamp with inbuilt driver and driver. LUMEN EFFICACY >110lm/w, PF >0.90, THD <20%, CCT 6000K, Make : Trilux, Wipro, Philips
Supply,installation, testing and commisioning of 600x600mm LED Panel Light of 42W LED Lamp White CRCA Luminaire Body and Micro prismatic diffuser, LUMEN EFFICACY > 120lm/w, PF >0.90, THD <20%,SPD 4kv CCT 6000K, powder coated housing, reflector, Diffuced PC cover with LED Panel and driver.Make : Trilux, Wipro, Philips
Supply,installation, testing and commisioning of Suspended Hi-Bay IP-65 100W LED light with Aluminum Die cast/Extruded housng with LED lamp and driver.LUMEN EFFICACY >100lm/W, PF >0.90, THD <20%, CCT 6000K, with Liquid Cool technology Make : Trilux, Wipro, Philips, Tucana
Supply,installation, testing and commisioning of Surface Mounted IP-65 100W LED light with Aluminum Die cast/Extruded housng with LED lamp and driver.LUMEN EFFICACY >100lm/W, PF >0.90, THD <20%, CCT 6000K, Make : Trilux, Wipro, Philips
Supply,installation, testing and commisioning of IP-65 -IK 07 ,10-12W LED Bollard light with die cast aluminum die cast powder coated housing, reflector,with LED lamp and driver.Make : Trilux, Wipro, Philips
Supply,installation, testing and commisioning of Wall Mounted IP-65 2x6W LED up-down light with die cast construction, Double reflector, toughened glass cover with LED lamp and driver.-PF>0.9 ,THD <20% ,Make : Trilux, Wipro, Philips
Supply,installation, testing and commisioning of IP-65 3-6W LED foot light with die cast aluminum 150-200 mm long Recessed / surfaced, IP-65 powder coated housing, reflector, toughened glass cover with LED lamp and driver. Make : Trilux, Wipro, Philips
Supply,installation, testing and commisioning of IP-65 3-6W LED Spike light with die cast aluminum 300 mm long spike, powder coated housing, reflector, toughened glass cover with LED lamp and driver.Make : Trilux, Wipro, Philips
Supply,installation, testing and commisioning of IP-65 35-40W LED Each LED Lmap Post made up of die cast aluminum, powder coated IP-65 housing, reflector, toughened glass cover with LED lamp and driversuitable for mounting on 3.0 Mtr FRP Light Pole. Make : Trilux, Wipro, Philips, K-Lite
Supply of approved make GRP / FRP Pole having following specifications: GRP Light Pole made by CNC filament winding machine using thermoset resin polyester/epoxy resin system) having minimum 62% glass content. The pole should be in one piece and tapered round in shape, having smooth finish and should be totally free from corrosion as well as non conductive & shock proof Pole should be provided with FRP Anchor Base and it should be heavy duty, or MS Material duly painted with Epoxy paint. Pole should be flame retardant as per IS 6746. Resin used shall be UV resistance and pigmented. A highly weather resistant polyurethane coating shall be applied to the pole after applying suitable primer system that ensures proper adhesion of the paint. Minimum coating thickness shall be 80 to 100 micron. Deflection of the pole shall not exceed more than 10% of the length of pole for the given load“? Pole should be generally made as per the dimensional data, performance criteria and some interchangeability features of poles as per standard ANSI C 136.20 latest version or ASTM D 4923/01 . The size of pole and type of installation are as below . [D] Overall length of 4 Mtr. Average Thickness: 7mm. Top/ Bottom OD Dia A/F 89/145 mm ± 2mm approx. Approx. Weight of Pole 19 kg approx. (Without Base) Anchor Base (Size 250X250 & 12mm th.)
High Mast : Supplying, erecting, testing, commissioning approved make M.S. Polygonal High Mast Pole having following general Specification. (a) Polygonal Section fabricated from M.S. Plate confirms BSEN 10025 & Hot deep galvanised minimum 65/86 micron (as per IS 01461) Lantern carriage with ring and rubber lines for erection of luminaries of suitable site. (b) Maximum telescopic section not more than four (c) Double drum gear pipe motorised winch with 6mm dia S.S. Rod (For 16 mtr and above size) (d) Approved make L.E.D. aviation light = 1 No. Lighting arrestor = 1 No. with necessary wiring of 2.5 sq.mm 5 core ISI copper cable Unarmoured. (e) Bottom most section suitable for mounting reversible motor and switchgears having door not more than 1400mm x 300mm with waterproof gasket & hinges & locking arrangement. (f) Pole structure comprises suitable size of reversible motor, cable and necessary switchgears. (g) bottom section shall have suitable size of thickness supports ribs foundation bolts nuts etc. (h) Item not comprises the cost of lanterns. (i) Necessary Cement Concrete foundation as per IS including testing & commissioning of the entire structure for following size of High Mast poles [CAT.II] [10] High Mast 30 Mtr. TOP A/F 170 Mm, BOTTOM A/F 610 Mm, No. of Sec. No. - 3, Bottom Thickness - 5 mm, Middle Base Sec. mm - 4 Top Sec. - 4 mm, Size Base Plate - 840 x 32, Foundation Bolt Size M36 x 1200, Qty - 12 Nos., Suitable for mounting Fitting of Light - 20 Nos. Make : Velmont, K-lite, Transrail
Supply,installation, testing and commisioning of 350-400W Flood Light on 35-36 Mtr High Mast with IP-66 Protection, Made up with die cast construction, CRI (Colour Rendering Index): - ≥ 70%, System Efficacy of Lighting fixtures 115Lm/W, Beam angle : -30D, Driver inbuilt Surge withstands capability should be ≥4KV, PF>0.9 ,THD <12% ,Make : Trilux, Wipro, Philips, Panasonic, K-lite
Providing M-20 / 1:2:4 cement concrete foundation & 70 % PCC from bottom including excavation for the pole of size 45 x 45 x 100 cms. Deep in below ground level with plinth of 45 cms x 45 cms (or 45 cms dia x 45 cms) high upper ground level with necessary curing and finishing in approved manner. ( for 4 & 6 mtr pole)
Supplying & erecting approved make SMC press moulded composite FRP. loop-in, loop-out approx. 2mm thick box complete with bakelite connector strip 4way & hinged doors having locking arrangements with mounting clamp with nuts, bolts & washers suitable for erection on pole with cable clamps& earth bolt of following size of box.: (b) 250mm x 200mm x 100mm [deep]
Supplying & erecting earth pit of minimum bore dia.150mm size approved make Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free G.I.Pipes having Outer pipe dia of 50mm having 80-200 Micron galvanising, Inner pipe dia of 25 mm having 200-250 Micron galvanising, connection terminal dia of 12mm with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for following type of applications. (c) For Electrical Installation covering Transformer Neutrals, Lightning arrester Earthing, A.C.Plant & Sensitive Computer System(like Automation, SCADA) i.e independent Earthing in normal soil. Length of Pipe : 3.00 mtrs Back filling Compound :2 nos Bags of 25 Kg.
Supplying & erecting earth pit of minimum bore dia.150mm size approved make Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free G.I.Pipes having Outer pipe dia of 50mm having 80-200 Micron galvanising, Inner pipe dia of 25 mm having 200-250 Micron galvanising, connection terminal dia of 12mm with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for following type of applications. (b)For Electrical installation up to 11 KV in normal soil. Length of Pipe : 2.00 mtrs Back filling Compound :1 no. Bag of 25 Kg.
Providing and erecting required size Copper strip for earthing of H.T. OCB / ACB/ Transformer, LT panel board, Motors etc. using copper clamp.
Providing and erecting HOT deep Galvanised iron strip wire 8 to 16 SWG.
Providing and erecting 1.6 - 1.8 mm thick FIA approved and ISI mark (embossed) RIGID PVC PIPES of following size complete erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following type of erection.2) For erecting concealed in RCC / Brick wall/slab or Open along with continuous fish wire to draw mains, laid in approved manner with plastering by cement mortar & finishing the surface to match the wall/ceiling. Supply and laying of 25 mm rigid PVC pipe of 1.6-1.8 mm thickness .
Providing following type of Modular Type Accessories mounted with pvc / metallic box, single mounting base frame covered with textured / metallic front plate , modules erected with necessary connection. (8) Modem Jack for Computer Open RJ-45 - cat-III
Providing following type of Modular Type Accessories mounted with pvc / metallic box, single mounting base frame covered with textured / metallic front plate , modules erected with necessary connection. (3) Two Pin/RJ-11 Telephone Socket for One Gong Bell - cat-iii
Supplying & erecting Push button type telephone instrument (A)BEETEL Secure / BPL/, SONY / PANASONIC or equivalent make
Supplying & erecting approved make LAN cable of following size in existing pipe as per direction : [C] CAT - 6
Supplying & erecting Delton or approved make Telephone Cable electrolytic copper conductor PE insulation twisted in two pairs, & wrapped with FRLS PVC tape & sheathed with FRLS PVC or HFFR outer Jacket suitable for telephone wiring & confirming to C-DOT erected in existing pipe. of following size of conductors & nos.of pairs. With necessary connections. (b) Armoured [Jelly Filled] - 10 Pair
Supplying & erecting Delton or approved make Telephone Cable electrolytic copper conductor PE insulation twisted in two pairs, & wrapped with FRLS PVC tape & sheathed with FRLS PVC or HFFR outer Jacket suitable for telephone wiring & confirming to C-DOT erected in existing pipe. of following size of conductors & nos.of pairs. With necessary connections. (b) Armoured [Jelly Filled] - 20 Pair
Supplying & erecting Delton or approved make Telephone Cable electrolytic copper conductor PE insulation twisted in two pairs, & wrapped with FRLS PVC tape & sheathed with FRLS PVC or HFFR outer Jacket suitable for telephone wiring & confirming to C-DOT erected in existing pipe. of following size of conductors & nos.of pairs. With necessary connections. (b) Armoured [Jelly Filled] - 50 Pair
Supplying, erecting, commissioning and testing EPABX CMOS microprocessor based system having common features With remote programming & remote dialling having following other common features. (Accord Matrix or equivalent approved make)- Auto Call Disconnector- (Incoming - Local- STD) with programmable timing- External Call forward with DOSA- Walk in Class of service & trunk reservation- Boss ring & call back on No Reply last caller recall CLI- Hot Line with Delay & with No.- Unsupervised Conference- Serial DISA ( DISA with option to dial another No. if Extn. is No Reply)- Programming Flexibility of all features related to timer( 41 Timer)-10 Different group of out going call restriction like 95, 97, 98 etc.Having following capacity. [C] No of Extension 48, No of Junctions 8, No of expandable ports:128, Operators Console - 01 Compatible: ISDN
Providing and erecting 1.6 - 1.8 mm thick FIA approved and ISI mark (embossed) RIGID PVC PIPES of following size complete erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following type of erection.2) For erecting concealed in RCC / Brick wall/slab or Open along with continuous fish wire to draw mains, laid in approved manner with plastering by cement mortar & finishing the surface to match the wall/ceiling. Supply and laying of 25 mm rigid PVC pipe of 1.6-1.8 mm thickness .
Providing & Erecting approved make following size of TV Co-axial flexible cable comprising inner conductor of solid bare copper insulated with Foam PE & Secondary conductor made of poly - Aluminium film bonded Al. Braids @ suitable coverage overall sheathed with black PVC insulation. RG-6 Cable
Providing & Erecting approved make following size of TV Co-axial flexible cable comprising inner conductor of solid bare copper insulated with Foam PE & Secondary conductor made of poly - Aluminium film bonded Al. Braids @ suitable coverage overall sheathed with black PVC insulation. RG-11 Cable
Providing following type of Modular Type Accessories mounted with pvc / metallic box, single mounting base frame covered with textured / metallic front plate , modules erected with necessary connection. for (4) TV Co-axial Socket outlet
Supply, Installation, Testing and Commissioning of 5 Megapixel HD Dome Camera, HD1080p,1/2.7" CMOS, 24 pcs LEDs, 20m IR, Indoor IR Eyeball, ICR, 0.1 Lux/F1.2, 12 VDC, Smart IR, DNR, DWDR, 3.6mm lens, 4 IN 1
Supply, Installation, Testing & Commissioning of 2 Megapixel HD Dome Camera, HD1080p,1/2.7" CMOS, 24 pcs LEDs, 20m IR, Outdoor IR Bullet, ICR, 0.1 Lux/F1.2, 12 VDC, Smart IR, DNR, DWDR, IP66, 3.6mm lens, 4 IN 1 OUTPUT
Supply, Installation, Testing and Commissioning of 16-Channel Digital Video Recorder recording with 4TB HDD with all require installation and integration with all camera system, 16 Turbo HD input, 16-ch video&1-ch audio input, 2 SATA interface, 1280×720P: 25(P)/30(N) fps/ch, 380 1U caseW/O HDD with all require software
Supply, Installation, Testing and Commissioning of 8-Channel Digital Video Recorder recording with 4TB HDD with all require installation and integration with all camera system, 8 Turbo HD input, 8-ch video&1-ch audio input, 2 SATA interface, 1280×720P: 25(P)/30(N) fps/ch, 380 1U caseW/O HDD with all require software
Installation, Testing and Commissioning of 32" Full HD LED monitor with Power Cord complete as required & necessary video cards complete as required (if required). Make - Sony, Samsung, Philips
Supply, Installation, Testing and Commissioning Power Supply for Camera
Supplying & Laying 24U Wall mounted Rack for the CCTV DVR installation with all require power ports fixed wall rack has a tempered glass door and removable locking side panels. Included with this rack is one set of fully adjustable cage-nut style rails and removable top and bottom cable slot panels, allowing easy installation of CAT5 or fiber optic cables.
Supplying & Laying 24 port rack mounted switch for the following specfiication Approved by cUL Listed, CE, EN 60950, FCC Part 15 Class A, TUV, UL Listed 24 10/100/1000Mbps RJ45 ports
Bio metric Access Control with face detection and having a memory storage of 35 days for 200 members
Supplying & erecting recess speaker with 5W rated input power 3.3 K. Ohms / 3W impedance, 100 - 10000 Hz frequency response with 6 inch dia. cone type 8 ohms speakers duly fitted in ABS plastic cabinet of colour match with wall or ceiling of following size. (a)Round Shaped, 230mm dia. Speaker Make - JBL, Harman, Yamaha
Supplying & erecting wall mounting speaker with 5W rated input power 3.3 K. Ohms / 3W impedance, 100 - 10000 Hz frequency response with 6 inch dia. cone type 8 ohms speakers duly fitted in ABS plastic cabinet of colour match with wall or ceiling of following size. (a)Round Shaped, 230mm dia. Speaker - Make - JBL, Harman, Yamaha
Supplying & erecting of Amplifier having following specification: Power Output :250W (RMS) (300W Max.) inputs : 6 Misc. & 2 Aux. frequency Response :50-1500HZ I3db Tone Controls :Cut & Boost type LED Meter :5 LED Arrays The amplifier suitable to operate 240V A.C.& 24volt D.C. (Battery) with automatic changeover from AC to Battery operation, duly protected by wrong Battery Polarity connections.Make - JBL, Harman, Yamaha
Supplying & erecting of Amplifier having following specification: Power Output :400W (RMS) (300W Max.) inputs : 6 Misc. & 2 Aux. frequency Response :50-1500HZ I3db Tone Controls :Cut & Boost type LED Meter :5 LED Arrays The amplifier suitable to operate 240V A.C.& 24volt D.C. (Battery) with automatic changeover from AC to Battery operation, duly protected by wrong Battery Polarity connections.Make - JBL, Harman, Yamaha
Supplying & erecting, Philips / Ahuja make Secretary unit comprising - 63 dBV, 7.5 mv/pa gooseneck microphone, Talk switch, Priority switch, Talk Switch LED, Ring LED indicator, connecting cable 6 core shielded, 2.5mtr long with female plug, 300 mw 8 ohms impedance speaker, connector for Delegate unit, volume control device fitted in heavy cast aluminium housing
Supplying & erecting, of 2cx1.5 Sq. mm Cu Flexible Speaker cable
Supply installation testing and commissioning High Speed quick power charging station for Trucks & Car for Electrical vehicle as per standard voltage rating with 40A FP MCB and 2 Nos 6A power plugs, it should have digital screen and all parameter recorders.
Supply installation testing and commissioning of roof top solar system with 20 years performance warranty , cost include high efficiency solar SPV module, require earthing, Lightening arrestor, supporting fabrication hot dip GI structure with paint, all require wiring, ACDB DCDB, Solar power meter, and inverter as require with consideration of 1-Year DLP
AMC : Comprehensive AMC with performance gurantee for the Installed Solar Panel for 1st Year after DLP (period 3% of Inititla Cost) Cleaning of panels, Preventive maitnancne, Checking of all wire connection, Inverter, Monthly Report to AMC etc
AMC : Comprehensive AMC with [erformance gurantee for the Installed Solar Panel for 2nd Year after DLP (period 3.5% of Inititla Cost) Cleaning of panels, Preventive maitnancne, Checking of all wire connection, Inverter, Monthly Report to AMC etc
AMC : Comprehensive AMC with [erformance gurantee for the Installed Solar Panel for 3rd Year after DLP (period 4% of Inititla Cost) Cleaning of panels, Preventive maitnancne, Checking of all wire connection, Inverter, Monthly Report to AMC etc
Supplyinhg certified, trained 2+Year Experienced / Electrician man-power for the Monthly Basis for 1st Year ( 15000 salary+10% margin of initial cost ) Scope of work to Operate & maintnance of the following Work HT VCB Panel, RMU, Transformer, Lt Panel, Cables, DB, MCB, MCCB, Capasitor, Light Fixtures, Fire Alarm Panel, Smoke-Heat Detector, HVAC System cable work, Light Pole, Facade Lighting, Data-TV-Telephone network and Equiment etc
Supplyinhg certified, trained 2+Year Experienced / Electrician man-power for the Monthly Basis for 2nd Year( 15750 salary+10% margin of initial cost) Scope of work to Operate & maintnance of the following Work HT VCB Panel, RMU, Transformer, Lt Panel, Cables, DB, MCB, MCCB, Capasitor, Light Fixtures, Fire Alarm Panel, Smoke-Heat Detector, HVAC System cable work, Light Pole, Facade Lighting, Data-TV-Telephone network and Equiment etc
Supplyinhg certified, trained 2+Year Experienced / Electrician man-power for the Monthly Basis for 3rd Year(16537 salary+10% margin of initial cost ) Scope of work to Operate & maintnance of the following Work HT VCB Panel, RMU, Transformer, Lt Panel, Cables, DB, MCB, MCCB, Capasitor, Light Fixtures, Fire Alarm Panel, Smoke-Heat Detector, HVAC System cable work, Light Pole, Facade Lighting, Data-TV-Telephone network and Equiment etc.
Supplyinhg certified, trained 2+Year Experienced Electrician man-power for the Monthly Basis for 4th Year(17365 salary+10% margin of initial cost) Scope of work to Operate & maintnance of the following Work HT VCB Panel, RMU, Transformer, Lt Panel, Cables, DB, MCB, MCCB, Capasitor, Light Fixtures, Fire Alarm Panel, Smoke-Heat Detector, HVAC System cable work, Light Pole, Facade Lighting, Data-TV-Telephone network and Equiment etc.
Comprehensive AMC for the Full Electrical Systemfor 1st Year after DLP (period 3% of Inititla Cost) - Performance bank gurantee to be submit at time of complwetion of work, Scope of work to Operate & maintnance of the following Work HT VCB Panel, RMU, Transformer, Lt Panel, Cables, DB, MCB, MCCB, Capasitor, Light Fixtures, Fire Alarm Panel, Smoke-Heat Detector, HVAC System cable work, Light Pole, Facade Lighting, Data-TV-Telephone network and Equiment etc
Comprehensive AMC for the Full Electrical Systemfor 2nd Year after DLP (period 3.5% of Inititla Cost) - Performance bank gurantee to be submit at time of complwetion of work, Scope of work to Operate & maintnance of the following Work HT VCB Panel, RMU, Transformer, Lt Panel, Cables, DB, MCB, MCCB, Capasitor, Light Fixtures, Fire Alarm Panel, Smoke-Heat Detector, HVAC System cable work, Light Pole, Facade Lighting, Data-TV-Telephone network and Equiment etc
Comprehensive AMC for the Full Electrical Systemfor 3rd Year after DLP (period 4% of Inititla Cost) - Performance bank gurantee to be submit at time of complwetion of work, Scope of work to Operate & maintnance of the following Work HT VCB Panel, RMU, Transformer, Lt Panel, Cables, DB, MCB, MCCB, Capasitor, Light Fixtures, Fire Alarm Panel, Smoke-Heat Detector, HVAC System cable work, Light Pole, Facade Lighting, Data-TV-Telephone network and Equiment etc
Liaoning with Local Electricity Board & Electrical Inspector for upgradation of Existing 11KV HT Power & Electrical inspector certification in totality to charge the power other related accessories. etc. complete. Charges for doing liasioning work for obtaining the necessary clearances from the Electrical inspector/competent Authorities for the total Electrical installation, Elevator Inspection, co-ordinating with various agencies. All necessary drawings, calculations, test certificates, etc. as required by the seauthorities shall be prepared and furnished by the EPCV endor. Any modification / rectification as required by these authorities shall be carried out by the EPCV endor at free of cost. The fees required to be paid to these authorities for inspection shall be borne by Owner on production of documentary evidences.
Liaoning with local authority / Fire Dept for roof top solar system Charges for doing liasioning work for obtaining the necessary clearances from the Electrical inspector/competent Authorities for the total Electrical installation, Elevator Inspection, co-ordinating with various agencies. All necessary drawings, calculations, test certificates, etc. as required by the seauthorities shall be prepared and furnished by the EPCV endor. Any modification / rectification as required by these authorities shall be carried out by the EPCV endor at free of cost. The fees required to be paid to these authorities for inspection shall be borne by Owner on production of documentary evidences.
R N Dobariya
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid