Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.0 LAccepted-AOC M S SATHYAM ENGINEERING KOOTHANKUZHI THIRUVALLUR TAMIL NADU 600 062 | THIRUVALLUR | THIRUVALLUR | TAMIL NADU | 600062 | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹48.4 L+₹2.0 L (4.34%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest tenderer | |
| 3 | L3₹49.2 L+₹2.8 L (6.13%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest tenderer | |
| 4 | L4₹54.0 L+₹7.6 L (16.4%)Rejected-Finance | L4 | Rejected-Finance Being other than lowest tenderer | |
| 5 | Rejected-Technical | - | Rejected-Technical Not having eligible category, hence, not meeting eligibility criteria, |
Tender Value
₹49.3 L
EMD Value
₹1 L
Closing Date
10 Dec 2022, 6:00 pmClosed
Shri Narinder Singh, IDSE, SE(SAG)
CWE Chennai Pallavan Salai Chennai-600 002
PROVN OF FIRE HYDRANT SYSTEM AND ALLIED WORK IN SHED NO 50 AT AF STN UNDER GE AVADI
2022_MES_548100_3
87666/E8
Open Tender
Construction Works
Item Rate
180 days
AVADI CHENNAI
As per Tender documents
9 documents required · 9 mandatory
₹500
GE AVADI
₹1 L
Yes
8 Feb 2023
21 Nov 2022
15 Dec 2022
21 Nov 2022
10 Dec 2022
28 Nov 2022
21 Nov 2022 - 25 Nov 2022
Amount
BOQ (Uploaded on 21 Nov 2022 ) SCHEDULE A PART I (CIVIL WORKS) M&L for Surface excavation not exc 30 cm deep and averaging 15cm deep and getting out in any type of soil
Excavation of trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation etc or for sharts, wells cessipts, manholes, pier holes etc 10 Sqm on plan and n exc 1.5 m in depth and getting out in any type of soil.
Excavation over Areas, exc 1.5 m in depth, for foundation etc or for sharts, wells cessipts, manholes, pier holes etc 10 Sqm on plan and n exc 1.5 m in depth and getting out in any type of soil.
Removing excavated material (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and as directed.
Returning filling in soil including spreading leveling watering well ramming in layers not exceeding 25 cm each all as specified and as directed.
M&L for Plain Cement Concrete 1:4:8 type D-2 (Using 40mm graded crushed stone aggregete) as in foundation, filling and mass concrete.
Use & waste of Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter
M&L Reinforced Cement Concrete M-25 design mix as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete
Use & waste of Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and as directed
M&L Reinforced Cement Concrete M-25 design mix as in Columns, pillars, piers, posts and struts
Use & waste of Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.
M & L Reinforced Cement Concrete M-25 design mix as in lintel over 1.5 mtr hight complete all as specified and directed
Use & waste of Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping)
M&L Reinforced Cement Concrete M-25 design mix as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in the shelves and the like
Use & waste Formwork to soffits to roof projection chajja facia complete all as spacified and as directed.
M&L Reinforced Cement Concrete M-25 design mix as in roof projection chajja and facia.
M & L TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality confirming to IS 432
All as per BOQ item No above but 6 mm to 8 mm dia
All as per BOQ item No above but 5 mm dia and over upto and including 10mm dia in stirrups, spacers and binders
M&L Brick work with fly ash bricks, straight or curved on plan exc 6 m mean radius, built in CM 1:6
M&L Brickwork with fly ash bricks, straight or curved on plan to any radius in half brick thick wall, built in CM 1:4
M&L for 10 mm thick rendering in CM 1:6 on fair faces of brick surfaces finished even and smooth without using extra cement complete all as spacified and as directed.
M&L rendering 10 mm thick on other than fair faces of brick surfaces or concrete surfaces in CM 1:6 with floating plaster 5mm thick in CM 1:4 mixed with water proofing compound complete all as specified and directed. (Note : WPC will be measured and paid seperately)
M&L Rendering 5mm thick on ceiling, in cement mortar 1:3 finished the surface even and smooth without using extra cement, complete all as specified and as directed.
M&L for preparing newly plastered wall surfaces and applying three coat of white washing complete all as specified and as directed.
M&L for Prepration newly plastered surfaces of wall and applying two coats of cement base paint to external wall surface complete all as specified and directed
M&L for prepration of new plaster surface of ceiling and applying three coat of white wash complete all as specified.
M&L for spreading and levelling in excavated material filling in floors or pavings laid in layers not exceeding 15cm thick, spread, levelled and rammed including watering etc. complete all as specified and as directed
M & L for Treating the backfill in contact with foundation at the rate of 7.5 litres of ATT emulsion 20 EC per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and as directed.
M & L for Treating the top surface of filled Earth at the rate of 5 Litres of emulsion per squre meters of surface area.
M & L for Treating the soil under plinth protection at the rate of 5 litres of ATT emulsion 20 EC per square metre of surface area complete all as specified and as directed.
Treating the soil alongwith external perimeter of building at the rate of 2.25 litres of ATT emulsion 20 EC per metre of the perimeter wall complete all as specified and as directed.
M&L for Hard core with broken stone or boulders of gauge not exceeding 63mm deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface all as specified.
M&L for Plain Cement concrete type D-2, 1:4:8 mix (using 40mm graded aggre-gate) as in Subbase of flooring of 75mm thickness
M&L for Non-skid ceramic coloured tiles, minimum 7mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match of superior finish, grade B1 quality over cement screed 1:4, 20mm thick including applying of cement slurry at the rate of 3 kg / sqm complete all as specified and as directed.
M&L for 75 mm thick in Plain cement concrte 1:3:6 type-C1 as in plinth protection surface finished fair and even without using extra cement all as specified.
Forming Construction joint 30mm deep x 10mm wide, filled with sealing compound grade 'A' comprising 1 Part of heated bitumen 85/25 grade and 3 parts of sand (all by weight) complete all as specified and as directed.
M&L for rendering 10mm thick in cement mortar (1:3) over roof surface/ chajja etc when the concrete is green finished even and smooth without using extra cement mixed with liquid Water proofing compound complete all as specified (Note - liquid Water proofing compound will be measured and paid for seperately)
M&L for Preparing the Concrete surface thoroughly to remove all loose particles, dirt / dust particles and applying a uniform coat of blown grade bitumen VG-10 @ 1.20 kg/sqm conforming to IS 702 over a coat of bitumen primer @ 0.40 Litres / Sqm followed by APP membrane reinforced with polyster non woven fabric 3mm thick weighing not less than 3.6 kg / sqm laid on primed surface by torched application followed by a finishing coat of solar reflective aluminium paint @ 0.10 litres / Sqm complete all as specified and as directed.
Supply only Liquid integral Water proofing compound.
M&L for Steel rolling shutters, with and including suitable ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of red oxide zinc chrome primer, erected in position as indicated, complete, gear operated type with bevel gear box, Safety lever lock (01 No) mild steel with 4 levers and crank handle 1.25mm lath thickness complete all as specified and as directed.
M&L for Anodised aluminium frame for doors, windows, ventilators with one or more rebates including Jointing cleat for fixing etc. powder coated to minimum 50 micron thickness complete all as specified and as directed.
Supply and fabricate only anodised aluminium window and ventilator shutters, side hung type without sash bar, including anodised aluminium shutter sections and anodised aluminium snap beading, joining cleats, glazing clips etc., powder coated to minimum 50 micron thickness complete all as specified and as directed. Notes :-(a) Rubber packing, anodised aluminium snap beading, screws etc as required shall be measured in Supply only Aluminium Shutters and the rates quoted are inclusive of the same (b) Glass or wire cloth as required shall be measured and paid for separately.
Fixing only anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary ioining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, and supply and fix of anodised aluminium fittings such as peg stays 150mm long (1 No), hinges type B-21, 100mm long (2 Nos/leaf), suitable handle (1No/Leaf.) , aluminum tower bolt 125mm (02 Nos/Leaf) etc., complete all as specified and as directed.
M&L preparing new steel surfaces over 10cm in width or girth and applying two coat of synthetic enamel paint over one coat of red oxide primer all as directed.
M&L Plain cement concrete type C-1 (1:3:6) 20mm graded stone aggregate as in bed blocks for fixing hold fasts or any other purpose all as specified.
M&L treating with tar or coal tar on holdfasts, back of chawkhats etc area not exc 0.1 Sqm each all as specified and directed
S&F Aluminium alloy wire cloth 0.45mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium to Aluminium frames complete all as specified and as directed.
M&L sheet glass 4 mm thick ordinary quality in squares exc 0.50 Sqm in each pane all as specified.
M&L for Sand filling under floors or in foundations or cushioning incuding spreading, levelling in layers n exc 25 CM thick and well ramming including watering and consolidation all as specified and directed
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with gray cement and no pigments all as specified and directed
M&L for providing precast cement concrete 1:2:4 type B1 in kerb stones of size 450mm x 330mm x 120mm set in cement mortar 1:4 including necesssay excavation, returning filling and soil disposal etc complete all as specified and directed by the Eng-in -Charge
SCHEDUL A PART II (INTERNAL ELECTRIFICATION) M&L for Point wiring on stone / brick masonry wall complete with two runs of 1.5 sqmm single core PVC insulated 1100 volts grade sheathed cable confirming to IS-694, 1977 with multistranded copper conductor, drawn through and including non-metalic rigid PVC conduit, conduit fittings and conduit accessories not less than 20 mm dia, concealed in walls & RCC roof and including provision of one 1.5 sqmm PVC insulated single core multistranded copper conductor green in colour as earth continuity conductor and connected to common earth dolly, including pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet, 60mm deep, concealed in walls, duly painted with two coats of anti-corrosive over a coat of red oxide zinc chrome primer and covered with hylam sheet cover 3mm thick fixed with cadmium plated screws for housing the switches, socket outlets, fan regulators etc., complete all as specified and as directed for one light point controlled by one switch. Note:- Cost of terminal box and cutting chases for concealing pipes is deemed to be included in the item rates quoted for point wiring.
All as per BOQ item No above but for one ceiling fan point controlled by one switch and regulator Note:- Cost of terminal box and cutting chases for concealing pipes is deemed to be included in the item rates quoted for point wiring.
All as per BOQ Item No above but for One switch socket outlet point 3 pin 5 Amps on independent board. Note:- Cost of terminal box and cutting chases for concealing pipes is deemed to be included in the item rates quoted for point wiring.
All as per BOQ Item No above but for One switch socket outlet point 3 pin 5 Amps on same board with other switches. Note:- Cost of terminal box and cutting chases for concealing pipes is deemed to be included in the item rates quoted for point wiring.
All as per BOQ Item No above but for point wiring with two 4.0 sqmm single core copper conductor multistranded cable and one 4.0 sqmm PVC insulated single core multistranded cable as earth continuity conductor green in colour for one 3 pin switch socket outlet, 15 Amps, on independent board complete all as specified and as directed. Note:- Cost of terminal box and cutting chases for concealing pipes is deemed to be included in the item rates quoted for point wiring.
M&L for Switch piano, flush type single pole, one way, 5 Amps complete all as specified and as directed.
M&L for Switch socket combination, flush type, 2 in 1, 3 pin, 5 Amps universal type complete all as specified and as directed.
M&L for Switch socket combination, flush type, 2 in 1, 3 pin, 5 Amps and 15 Amps universal type complete all as specified and as directed.
M&L for Ceiling rose, 3 terminal, PVC / polycarbonate, insulated body complete as specified and as directed.
M&L for Stepped type electronic fan regulator, 300 W, flush type, including fixing on existing laminated sheet complete as specified and as directed.
M&L for Surface and wall mounted LED tube light fitting, 20 W, batten type, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver complete with all accessories, suitable for operation on AC, single phase 220 / 230 Volts, 50 Hz supply, and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting with the following parameters,complete all as specified and as directed. Note : Make shall be C&S Cat No.NAKSHATRA / 20W or its equivalent in Havells/Crompton/Bajaj as approved
LED building security light fitting 35W made up of pressure die cast aluminium housing with high power LED as lighting source and lens with IP66 protection complete pre-wired and connecting up with suitable twin core flexble copper wire including provision of necessary GI tubing medium grade 40mm bore of pipe 1.5 bent to shape with necessary clamps made out of mild steel, nuts and bolts etc., including two coats of synthetic enamel paint over a coat of red oxide primer on exposed steel surface for fixing the fitting to steel tubular poles etc complete all as specified and as directed.Note : Make shall be C&S Cat No INDUS / 20W / LS or its equivalent in Havells/Crompton/Bajaji as approved
S & F of Ceiling fan 1200mm sweep, without regulator, double ball bearing type, opal white colour, with suitable down rod, AC single phase, 240 Volts, 50 Hz and connecting including provision of two way PVC connectors, 1 sqmm flexible three core multistranded copper conductor cable from ceiling rose or connector to fan complete all as specified and as directed. Note:- Make shall be of Usha Cat No.ENERGIA ISI or or its equivalent in Havells/Crompton/Bajaji as approved
S & F of MCB DB SPN 8 way, single door, powder coated, 240 volts, AC, 50Hz, IP 43 protected, with provision for MCB double pole as incomer and DP / SP MCBs as outgoing with tinned copper bus bar, neutral link, earth link and connecting up complete all as specified and as directed. Note : (i) MCBs as required shall be measured and paid separately (ii) Make shall be of Legrand Cat No. 5076 10 / Havells Cat No. DHDNSHODAW04 / C&S Cat No. CSDBSPNDD04
S & F of MCB 6-40 Amps, SP, 240 Volts, 50 Hz, AC supply, "C" curve, with breaking capacity of 10 kA complete all as specified and as directed.
S & F of MCB 40 Amps, SPN, 240 Volts, 50 Hz, AC supply "C" curve with breaking capacity of 10 kA complete all as specified and as directed.
SCHEDUL A PART III (FIRE HYDRANT SYSTEM ) Supply, Install,Testing and Commissioning of Fire pump diesel engine driven horizontal end suction, centrifugal type confirming to IS- 12469, 1988 with CI casing, bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for continuous operation with 'range of operation' 0 % to 150 % of rated capacity 70 m Head. 1620 LPM discharge ,1800 RPM complete all as specified and as directed
S&F fire hydrant Landing valve type B ( double head outlet) of 63 mm dia conforming to IS 5290 complete all as specified and as directed
S&F Branch pipe gun metal 63mm instantaneous inlet, made threaded outlet, with 15mm bore nozzle short conforming to IS 903 complete all as specified and as directed
S&F Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard for hose reel of 20 mm size of 30 meter length complete with coupling branch pipe and nozzle complete all as specified and as directed
S&F hose reel of 20 mm dia and 30 meter length with drum conforming to IS 5132 with GM nozzle complete all as specified and as directed
S&F Branch pipe gun metal 63mm instantaneous outlet, made threaded outlet, with 20mm bore nozzle short conforming to IS 8090 complete all as specified and as directed
S&F fire hydrant Flanged stand post CI of 80mm dia 1.5m height complete all as specified and as directed
Supply and Installation of Electric Driven Jockey pump horizontal end suction centrifugal type Confirming to IS- 12469:1988 with CI casing , bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for automatic operation with nonover loading power characteristics for frequent start / stop operations for 440 V , 3 phase, 50 Hz, delivering 180 LPM , 70 mtr head in and including suitable star delta starter and all necessary pipe line connections , valves and wiring complete all as specified and as directed
Supply and Installation of Fire pump electrically driven horizontal end Suction, centrifugal type confirming to IS- 12469 :1988 with CI Casing , bronze impeller and Stainless steel shaft mounted on heavy duty bearings Suitable for continuous operation with 'range of operation' 0 % to 150 % of rated capacity for 440 V , 3 Phase. 50 Hz 70m Head, 1620 LPM discharge,2900 RPM in and including suitable star delta starter and all necessary wiring complete all as specified and as directed
S&F MS flanged pipe 100mm NB heavy duty for multi storied building duly painted with 2 coats of synthetic enamel paint over coat of zinc chromate primer complete all as specified and as directed
S&F of MS flanged pipe 80mm NB heavy duty for multi storied building duly painted with 2 coats of synthetic enamel paint over coat of zinc chromate primer complete all as specified and as directed
S&F 80mm bore hand operated butterfly valve of pressure not less than 15 Kg / Sqcm with complete set complete all as specified and as directed
S&F 100mm bore hand operated butterfly valve of pressure not less than 15 Kg / Sqcm with complete set complete all as specified and as directed
S&F non return butterfly valve, 100 mm bore tested to pressure of 15Kg/ Sqcm complete set complete all as specified and as directed
S&F Pressure gauge 100 mm dia with ball valve of pressure 21 Kg/Sqcm complete all as specified and as directed
S&F Gun metal fire brigade inlet connection for connecting to external fire hydrant ring main consisting of two nos 63mm dia instantaneous type male coupling complete all as specified and as directed
S&F CI strainer for suction 100mm dia complete all as specified and as directed
S&F Air Cushion Vessel 100 Ltrs capacity, Max Pressure 15 Bar made upof Mild steel including pressure gauge, air release valve complete all as specified and as directed
Laying in trenches Fine Seived Excavated Dry Soil including spreading / leveling, cushioning for underground cables all as specified and as directed.
Supply and laying of common burnt clay building bricks, sub class B of size 230x115x75mm for cable protection all as specified and as directed.
M&L for Plain cement concrete in foundations filling and mass concrete 1:3:6 mix (20mm graded aggregate) Type C-1 for pumpset/Transformer foundation all as directed.
M&L for XLPE insulated, armoured, heavy duty electric cable with aluminum conductor, 1100 volts grade, 95 sq mm 3.5 Core cross-sectionl area complete all as specified and as directed:- Note : The earth work excavation,sand cusioning and cable cover shall be measured and paid for seperately.
M&L for XLPE insulated, armoured, heavy duty electric cable with aluminum conductor, 1100 volts grade, 3.5 Core 70 sq mm cross-sectionl area complete all as specified and as directed:- Note : The earth work excavation,sand cusioning and cable cover shall be measured and paid for seperately.
M&L for XLPE insulated, armoured, heavy duty electric cable with aluminum conductor, 1100 volts grade,4 Core 10 sq mm cross-sectionl area complete all as specified and as directed:- Note : The earth work excavation,sand cusioning and cable cover shall be measured and paid for seperately.
Supply installation erection commissioning and testing of LT Feeder Pillar cubical in door type weather/dust proof, factory made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement panel base of angle iron 50x50x6 mm upto 45 cm height for 433 volts, 3 phase, 4 wire system including Four Pole Aluminium bus bar 400 amp capacity including control wiring with suitable size of PVC insulated stranded copper conductor and incoming/outgoing connection with aluminium busbar complete as per manufacture design complete mounted or fixed on PCC foundation above 0.45 mtr on floor and cable connection with suitable size of aluminium lugs and glands , LT Panel of suitable size for comprising the following components including accomadate star delta starter for fire and jockey pumps quoted in item No 8 and 9 above complete all as specified and as directed. (a) INCOMING MCCB (i) MCCB,100 Amp 4 pole, FE Frame,Ics=75% of Icu, 36 KA breaking capacity with adjustable Microprocessor release -01 Nos. (b) Outgoing MCCBs (i) MCCB,63 Amp 4 pole, FE Frame,Ics=75% of Icu, 36 KA breaking capacity with adjustable Microprocessor release -03 Nos (ii) Indicating Lamp LED Type - 01 set of three (iii) Multifunction meter digital type -01 No. Note :The design /layout of Feeder pillar box has be got appoved from GE before placing of order/ fabrication.
Earthing complete with galvanised iron earth plate electrode 600mm x 600mm x 6mm thick, with and including earthing of 4mm dia GI wire protected by 15mm dia GI pipe light grade upto a length of 7.5m. The plate shall be buried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of the earth plate at a depth not less than 1.5 metres below ground level, connected to earth lead as described here-in-before by means of bolts, nuts, washers and checknuts made out of galvanised iron or mild steel, earthing lead protected by as described here-in-before and connected to main switch board or main control board or electric pole all as shown on electrical plate No 3 of MES Sch Part-I including necessary earth work and excavation in any type of soil, plain cement concrete 1:3:6, type C1 chamber, reinforced cement concrete cover slab with locking arrangement and handle of 10mm dia MS round bars 450mm long, 1:2:4 type B1, 50mm thick with 8mm dia TMT bars at 140mm centre to centre both ways, GI pipe of bore 20mm medium grade for watering with funnel, wiremesh, salt, charcoal, lugs including testing complete all as specified and as directed.
Earthling complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground earth pit not less than 2.25 m deep below normal ground level with the top edge of earth plate at a depth of not less than 1.5 m below normal ground level connected to GI earth strip 32x6 mm dia by means of bolts, nuts, check nuts and washers made out of GI and GI earth strip protected by 40 mm bore light grade GI pipe,watering arrangement by provision of 20mm dia GI pipe medium grade with cast iron funnel,provision of test point and connected to main control board all as shown in electrical plate No 3 of SSR Part I including necessary earth work and excavation in any type of soil and PCC 1 : 2 : 4 type B - 1 in chamber and 40 mm thick RCC 1 : 2 : 4 type B - 1 cover slab with 6 mm dia mild steel bars at 100 mm centre to centre both ways with 6 mm dia M S hooks complete all as specified and as directed.
VIJAYALAKSHMI ENTERPRISES
Green Ray Technologies
M/s Omm Muruga Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .