Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹40.0 L+₹3.0 L (8.11%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹41.9 L+₹4.9 L (13.2%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹41.9 L+₹4.9 L (13.4%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹43.6 L+₹6.6 L (17.9%)Rejected-Finance 00 JAI BHAWANI COMPLEX MAIN ROAD SADAR WARD JAGDALPUR BASTAR CHHATTISGARH 494001 | BASTAR | CHHATTISGARH | 494001 | L5 | Rejected-Finance Being L5 |
Tender Value
₹42.7 L
EMD Value
₹85,400
Closing Date
10 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (MIS) MHOW
GE (MAINT) INF SCHOOL, 75 MALL ROAD MHOW
PROVN OF GEYSRES IN JCOs OR MD ACCN AT ARTRAC LINE CB AREA MH AREA AND PROVN OF SPU ON ROOF TOP IN OTM ACCN AT INF SCHOOL MHOW UNDER GE MIS MHOW
2021_MES_459178_1
GE MIS MHOW/33 OF 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (MIS) MHOW
Please refer tender documents
8 documents required · 8 mandatory
₹500
GE (MIS) MHOW
₹85,400
Yes
18 Sept 2021
13 Jul 2021
12 Aug 2021
20 Jul 2021
10 Aug 2021
27 Jul 2021
60 days
Amount
Supply and fix of electric water heater storage type, Capacity 25 litres and heating helement 2 KW, BEE 5 Star rated complete with all accessories such as a safety valve,thermostate,NRV,connection pipes of GI/PVC and necessary electric connections etc. complete all as specified and directed. Make : CG/Havelles/Bajaj
S&F of PVC connection Heavy duty 24" long 15mm dia with 2 Nos brass check nuts suitable for Hot water complete all as specified and directed.
Cutting chases, pininig in, making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landing, steps, cills, sunshades, shelves, lintal etc and cutting chases for concealed water tubing etc and making good, cutting not exc 20 cm girth in walls etc complete all as specified and directed.
Supply & fix of 15 mm bore steel water tubing "medium grade" galvanised with all fittings and fixed complete to walls and ceiling or laid in floor etc complete all as specified and directed.
Supply & fix Stop valves 15 mm , chromium plated fancy type cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
Supply & fix of Bib taps 15 mm , chromium plated fancy type cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed down,screwed for iron pipe or for unions and fixed complete all as specified and directed.
Supply & fix of MCB SPN, 32 AMP rating 240 V, 10 KA breking capacity "C " curve in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
M & L for Point wiring with FRLS PVC insulated and unsheathed electric cable 1100 volts grade single core having multistranded copper conductor of 2.5 Sqmm nominal cross sectional area for phase & neutral, drawn in and including non metallic rigid PVC conduit in concelead in walls not less than 25mm base size with all fitting and fixing accessories and with 2.5 Sqmm green FRLS PVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor connected to earth dolly by providing suitable lugs excluding galvanised boxes of suitable size with white laminated bakelite sheet for mounting switches,sockets etc complete for 15 amps socket point on independent board controlled by one switch complete all as specified and directed.
Cutting chases, pininig in, making good to facing where required and pointing in cement mortar (1:3) to ends or edges of landing, steps, cills, sunshades, shelves, lintal etc and cutting chases for concealedconduit wiring etc and making good, cutting not exc 20 cm girth in walls etc complete all as specified and directed.
Supply & fix of Switch socket combination 2 in 1,3 pin ,5 pin and 15 Amp flush type universsal fixed complete all as directed by Engr-in -charge .
Supply, Installation, Testing & Commissioning of Roof top Solar Power Plant of 25 KW including Solar Panels, Solar Inverter, Module Mounting Structure and comprising of following:- complete all as specified and directed.
Solar PV module multi crystalline structure of size 1960x990x42 mm,Pmax 330 Wp C-Si 76 cells Efficiency not less than 16.20 , Voc 45.00 , Isc 9.03, AR coated antimony free glass material with connecting Junction box all as spd. = 75 Nos Make :- lanco , Adani , Tata , Topsun, Havells ,WAAREE, LUMINOUS
Grid tied inverters 3 phase 25 KW 50 HZ having MPP tracker with SPD glass , surge protection devices having efficiency 98% graphical display - inbuilt LED interface with RS 485 and compatible for online monitoring system suitable for Ambient temperature , protection IP 65 , Overvoltage / under voltage protection all as spd . Make :- ABB, Delta , Siemens , WAAREE, HavellsLUMINOUS ,Schneider , Tata. = 01 Set Note:- Inverter shall be capable of synchronisation with grid supply and DG Set supply.
DC Solar distribution Box to collect the DC output from Array junction Box 6- Input , 6- Output SPD Type-II and supply to Inverter weatherproof for outdoor applications and including MCB / MCCB of proper rating depending upon the cap of the power plant complete all as spd. Note: As per requirement Solar connector MC4 (Male & Female),Cu cable 4 sqmm,1.1 kv(DC)grade resistance, communication cable CAT6, XLPE Cu Arm. 1.1 kv ,4cx16 Sqmm from Inverter to LT Panel & LT panel to Rectofeeder panel are deemed to be included in the rate quoted. Make :- HPL / Schneider / Siemens / ABB/ Havells - 01 Set
AC distribution Board(LT Panel-wall mounted) 415v,50 Hz Incomers/Outgoings:63A 4P,25 KA MCCB Provision for meter & CT having bus bar 3 phase 4 wire 415 volt, 50 Hz/ 1 Sec AL. Bus bar with energy meter Bi directional meter with 3 CT, CT Ratio: 60/5A, CI: 0.5,5VA & Uni Directional meter with 3 CT , CT Ratio : 60/5A, CI: 0.5, 5VA to collect the AC output from Inverter weatherproof for outdoor applications and including MCB / MCCB of proper rating depending upon the cap of the power plant complete all as spd. Note:- Make :- HPL / Schneider / ABB/ Siemens/ Havells = 01 Set
Grid interfacing unit having MCCB cap 40 amp 4 pole 25 KA microprocessor based all as spd. Make :- ABB / Schneider / L&T / Siemens/ Filatech = 01 Set
AC / DC cables ISI mark, GI perforated cable Tray size 25x100x1.6 mm as per site requirement or as per direction by Engr - in- Charge.
All materials used shall have a proven history of reliability and stable operation in external applications.It shall perform satisfactorily in relative humidity upto 100% with ambient temperatures between -4°C and +60°C and shall withstand gust upto 200km/h on the surface of the panel. Each and every SPV module shall be checked for conformity with relevant standard and no negative tolerance shall be accepted.
Online monitoring system with Ambiebt temperature sensor,Module temperature sensor, Irradiance sensor Make :- Delta/ ABB/ or as approved
ESE type lightning arrester (coverage radius 40 meter) with base plate(150x150 mm) & mounting assembly/accessories with LA strip 25x3 mm GI Flat (2 Run) approx 100 meter with LA Earth cable 16 sq mm cu cable1.1 kv grade, GI Earthing strip 25x3 sqmm approx 300 meter and GI Earthing Electrode with chemical earthing component: 1 mtr long (4 Nos), Earthing chamber & LA padastel shall be 1:2:4 RCCconstructions(4 Nos).
Note :- Entire work of solar power plant shall be got executed from specilist firms ie GE/ Suzlon / tata /WAAREE / LUMINOUS / Topsun/ Havells Energy Pvt Ltd. The cost of applicable charges / permission from UPNEDA etc all as reqd deemed to be included in quoted rate and One year free O&M . Charges of installation by specilist are deemed to be included in the rate quoted.
Supply and fixing 3 Phase Solar Bidirectional Net Meter as per IS 13779 , Current rating 10-60 Amp , accuracy class 1, seprate reading for active energy kWh & kVAh Import & Export, Net energy kWh with sign complete all as specified and directed. Make: L&T , Secure or equivalent.
Miscellaneous items like Dr Fixit proofing agent, Fischer tube, Sticker for inverter & Danger, Rubber Mats, Fire bucket, Do's & Don't Board, First Aid kit Box, PVC Conduit 1 inch, Fastener for inverter & LT Panel mounting M8,Numbering ferrule 6 mm, Lugs, Cable tie black UV Resistant 300 mm,chamber pit cover of 1 Fit x1 Fit, 600VA UPS for data logger etc are deemed to be included in the quoted rate.
Supply laying & testing of XLPE insulated, armoured, heavy duty electric under ground cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete of size 35 Sqmm nominal cross section 3.5 core.
Excavating in trenches, in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil complete all as specified and directed.
Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Sand cushioning with fine dry unwashed sand in trenches for protection of cables complete all as specified and directed.
Old size sub class ‘B’ bricks, laid in trenches as cable covers complete all as specified and directed.
Supply and fixing of Steel tubes, galvanised, light grade, ISI marked 40mm bore for protection of cable under floor, road and on wall complete.
M&L for earthing complete with copper earth plate electrode (600mm X 600mm X 3.15) mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to copper earth strip (20 X 3) mm size(upto 7.5 meter from ground electrode) by means of copper/ steel bolts, nuts, check nuts and washers all as shown in electrical plate No 3 of SSR Part-I connected to earth test terminal block and testing on completion with and including 25 mm bore, light grade GI protection pipe for strip upto plinth protection, PCC pit in mix 1:3:6 type C1 with RCC (1:2:4) type B-1, 40mm thick cover, reinforced with 6 wire mesh and 20 mm bore medium grade GI watering pipe, common salt and charcoal filling, necessary excavation and earth work complete all as shown in electrical plate No 3 of SSR Part-I complete all as specified and directed.
S & F of Rolled sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc.Fe 410-W(Gde-E- 250)quality-A complete all as specified and directed.
S & Fof Mild steel screw bolts (machine made) dia of neck 5 to 10 mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long etc complete all as specified and directed.
All as per item no 21, but length of bolt exc 10cm and n exc 15cm long complete all as specified and directed.
S & F of wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
Cutting holes in brick walls built in cement mortar exceeding half brick but n.exceeding one brick for inserting hold fasts or similar work and make good the dismantled portion in plain cement concrete (1:2:4) type B-1 using 20mm graged stone aggregate complete all as specified and directed.
preparation of new steel surfaces of any description over 10cm width or girth and apply two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M & L for PCC (1:2:4) type B0 (using 12.5 mm graded stone aggregate) as in foundation of module mounting structure finished even and fair for laying floor finishes etc complete all as specified and directed.
M & L for preparation of surfaces for applying bituminous primer (conforming to IS-3384-1965) @ 0.40 Kg/Sqm complete all as specified and directed.
M & L for applying a tack coat of Industrial bitumen grade of 85/25 at the rate of 1.2 Kg per Sqm including cleaning surfaces (1st coat for bonding material below membrane and 2nd coat on top of membrane. Each coat would be paid seperately.) complete all as specified and directed.
M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified and directed.
Auto Traders
M/S UnitedConstruction
Ankit construction
SANJAY ENTERPRISES
ENVIRO TECH SERVICES
Vinayak Trading House
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .