Dy. Chief Engineer(ES) Circle HPSEBL Totu Shimla
Dy. Chief Engineer(ES) Circle HPSEBL Totu Shimla
Tender for Dismantling of old CTs and LAs along with erection, retrofitting, testing an commissioning of new CTs and LAs, replacement of defective relays and overhauling of breakers of various types in 132/66/33kV sub-station Jutogh and 66/22kV
2023_HPSEB_80515_1
SEES/SHIMLA-358/2023-24
Limited
Electrical Works
Item Rate
30 days
Gumma
please refer tender documents
4 documents required · 4 mandatory
₹1,180
Yes
₹14,800
Yes
20 Nov 2023
20 Oct 2023
31 Oct 2023
20 Oct 2023
30 Oct 2023
20 Oct 2023
Amount
A)132/66/33kV sub-station Jutogh
Dismantling of old 132kV CT's of 132/33kV transformer bank-I and placing/ stacking the same at a safe location in the sub-station along with erection, retrofitting, testing and commissioning of new 132kV CT's complete in all respect as per direction of Engineer-in-charge
Dismantling of old LA's of 132/33kV transformer bank-I and placing/ stacking the same at a safe location in the sub-station along with erection, retrofitting, testing and commissioning of new 132kV LA's complete in all respect and as per direction of Engineer-in-charge
Hiring of hydra for unloading, lifting and shifting of heavy EHV equipment within 132kV yard area as per direction of Engineer-in-charge
Providing, retrofitting, wiring and fixing of numerical non directional 3O/C+1E/F relay on 33kV khalini feeder with high set unit, 220VDC, TMs range 0.05 to 1.00 sec (in steps of 0.01 each), rated current = 1A, Range I = 40% to 200% ( in steps of 1% for O/C protection with IDMT characteristics, 10-100% in steps of 1% for E/F protection with IDMT characteristics compatible with IEC 61850 protocol, Make Ashida, Model:ADR241B complete in all respect and as per direction of Engineer in charge
Providing,retrofitting and fixing of silica gel breathers (main tank/conservator) in 132/33kV, 4x10.5 MVA transformer bank complete in all respect (Capacity: 4Kg, make: BHEL).
Providing,retrofitting and fixing of silica gel breathers of OLTC's in 132/33kV, 4x10.5 MVA transformer bank complete in all respect (Capacity: 0.5Kg, make: BHEL).
Providing, retrofitting, wiring and fixing of master trip relay with 4 NO+1NC, operting voltage: 220VDC, Make: Ashida complete in all respect as per direction of Engineer in charge
Providing & fixing of heavy duty equipment/conductor clamps along with replacement of rusted/damaged/worn out/ hotspot bearing & burnt clamps in 33kV yard complete in all respects.
33kV CT-Clamp (Wolf)
66/22kV sub-station Gumma
Complete overhauling of 66kV breakers of transformer II & 66kV Hulli along with repair & replacement of damaged/worn out parts [motor with gear box, leaf springs, limit switches, latches, tension springs, gears, rods, tripping & closing coils,auxiliary switches, indication lamps TNC Switches in local outdoor mechanism and C&R panel etc.] along with its alignment, greasing of various parts/gears, removal from lockout state, refilling of SF6 gas and rectification of wiring circuit from yard area to C&R panel concerned. Post overhauling the breaker shall be checked for proper C-O-C/O-C-O operation in (auto & manual mode) locally and from its C&R panel, proper charging of spring through motor & in manual mode as per satisfaction of Engineer-in-charge.
Troubleshooting and rectification of wiring circuit from 66kV Jutogh-Gumma breaker to their respective C&R panels for ensuring healthy operation of breaker from its C&R panel along with greasing of gears/parts of their operating mechanism. Post rectification the breaker shall be checked for proper C-O-C/O-C-O operation in (auto & manual mode) locally and from its C&R panel, proper charging of spring through motor & in manual mode as per satisfaction of Engineer-in-charge.
Providing, retrofitting, wiring and fixing of numerical non directional 3O/C+1E/F relay on 33kV khalini feeder with high set unit, 220VDC, TMs range 0.05 to 1.00 sec (in steps of 0.01 each), rated current = 1A, Range I = 40% to 200% ( in steps of 1% for O/C protection with IDMT characteristics, 10-100% in steps of 1% for E/F protection with IDMT characteristics compatible with IEC 61850 protocol, Make Ashida, Model:ADR241B complete in all respect and as per direction of Engineer in charge.
Providing & fixing of heavy duty equipment/conductor clamps along with replacement of rusted/damaged/worn out/ hotspot bearing & burnt clamps in 22kV yard complete in all respects.
22kV CT-clamp (as per sample)
VINAY ENTERPRISES
ANUSHREE ELECTRICAL ENGINEERS PRIVATE LIMITED
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .