Loading…
Loading…
Tender ID
Tender Value
Refer Docs
EMD Value
₹43,000
Closing Date
13 Mar 2026, 9:30 pmClosed
Public Works Department
Suresh Babu AEE No.10
Supply, Installation, Testing, and Commissioning of Outdoor LED Video Wall Display Providing Air Conditioner & Connected Electrical works of Press Club, located in the premises of Cubbon Park, Bengaluru
PWD/2025-26/EL/WORK_INDENT31911
PWD/2025-26/EL/WORK_INDENT31911
Open
Electrical
Two Tender Document System(Two Cover)
PWD Electrical Division Office Bengaluru
7 documents required · 7 mandatory
3.2 To qualify for award of this contract, each Tenderer in its name should have in the last five years 2020-21 to 2024-25 c) Executed in any one year the following minimum quantities. 1) SITC of IP1.5 Indoor LED Full Color Video Wall Display System -100 Nos, 2) SITC of Air Conditioners - 2 Nos
3.2 To qualify for award of this contract, each Tenderer in its name should have in the last five years i.e., 2020-21 to 2024-25 b) satisfactorily completed (Usually not less than at least 50% of Estimated value of Contract), as prime contractor, at least one similar work ie., SITC of LED Video Wall Display, Air Conditioner & Connected Electrical works of value not less than Rs.10.60 Lakhs
The tenderer as a Prime Contractor having valid Class-2 & above Electrical License issued by Electrical Inspectorate Govt of Karnataka and should have suitable technical, financial & managerial capabilities.
3.3Each Tenderer should further demonstrate: (b) liquid assets and /or availability of credit facilities of not less than Rs.6.36 Lakhs (For Particular work only) (Credit lines/ letter of credit/ certificates from banks for meeting the fund requirement etc.(usually 30% of the Amount of Contract)
The Tenderer must submit ongoing and existing commitments details separately.
3.6Tenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated as under/ Assessed available tender capacity - (AxNx2.5 - B ) Where, A-Maximum value of construction works executed in any one year during the last five years (updated 2025-26 price level) taking into account the completed as well as works in progress. N Number of years prescribed for completion of the works for which tenders are invited. (03 Months) B - Value, at 2025-26 price level, of existing commitments and on-going works to be completed during the next. (03 Months) (period of completion of the works for which Tenders are invited) Note: The statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent
3.2 To qualify for award of this contract, each Tenderer as should have in the last five years 2020-21 to 2024-25. a) The tenderer should have Achieved in at least two financial years an average annual financial turnover of Rs.21.19 Lakhs (Usually not less than the estimated cost under this contract of works)
Nil
Nil
Nil
Nil
Nil
Nil
Nil
Nil
₹530
₹43,000
26 Feb 2026
26 Feb 2026
16 Mar 2026
6 Mar 2026
Supply, Installation, Testing, and Commissioning of Outdoor LED Video Wall Display Providing Air Conditioner and Connected Electrical works of Press Club located in the premises of Cubbon Park, Bengaluru
Supply Installation, Testing & Commissioning of IP1.5 Indoor LED Full Color Video Wall Display System of size (W 3200MM x H 2400MM) (W 10.49ft x H 7.87ft) designed for wall/Floor mounting, operating o...
Supply Installation Testing and Commissioning of Indoor Control System with SMP6 pro complete the window wall Video Wall Display controller is a professional LED display controller. Besides the functi...
Supplying .TR split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed compressor with air cooled condenser, motor capacitor and start run capacito...
Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A/C.(6.12) --...
Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas...
Service Charges for 1TR to 3 TR split type AC unit and general checkup etc., Approved by SEBLDC vide letter No. 705 dated 11.5.2020 ---- including cost and conveyance of all materials, labour and othe...
Supplying and fixing the fan motor for blowers and condenser of 1/5 HP, single shaft/double shaft suitable for split /window air conditioners. 6.18) ---- including cost and conveyance of all materials...
Extra for Fabrication supply and fixing of Stand fabricated using slotted angle /L angle of size 6mm x 50mm for mounting out door/indoor A.C. unit/ Batteries.6.22) ---- including cost and conveyance o...
Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for work...
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
kppp-2 31911.docx
Tender Document • 0.91 MB
government notification bc loc letter to be issued by the bank.pdf
Others - Bankers Certificate format • 1.73 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .