| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 LAccepted-AOC | ₹2.0 L | L1 | Accepted-AOC L1 |
| 2 | L2₹2.0 LRejected-Finance | ₹2.0 L | L2 | Rejected-Finance L2 |
| 3 | L3₹2.0 LRejected-Finance | ₹2.0 L | L3 | Rejected-Finance L3 |
| 4 | L4₹2.0 LRejected-Finance | ₹2.0 L | L4 | Rejected-Finance L4 |
Tender Value
Refer Docs
EMD Value
₹4,100
Closing Date
20 Jan 2026, 4:00 pmClosed
Executive Engineer (A-M) Burdwan (A-M) Division
Kalna Road, Near Agril Farm, Purba Bardhaman- 713101
Repairing and Rewinding of Squirrel cage Induction Electro Motor for Maintenance of different RLI schemes under Durgapur (A-E) Sub-Division under Burdwan (Agri-Mech) Division under Maintenance Programme in the District of Paschim Bardhaman.
2026_WRDD_983526_3
WBWRDD EE AM BDN eNIT-33 (Sl No 01-03) NP 2025-26 (SL No- 01)
Open Tender
Electrical Work/ Equipment
365 days
Durgapur, Durgapur Municipal Corporation
Please refer Tender documents.
3 documents required · 3 mandatory
₹4,100
13 Feb 2026
7 Jan 2026
22 Jan 2026
7 Jan 2026
20 Jan 2026
7 Jan 2026
Repairing and Rewinding of 17.5 H.P./ 20 H.P. 3 phase, 440 Volt Squirrel cage Induction Electro Motor for Maintenance of different RLI schemes under Durgapur(Agri-Elec.) Sub-Division under Burdwan (Agri-Mech) Division under Maintenance Programme in the District of Paschim Bardhaman. Please see the details in Sheet Rewinding
BoQ_Ver3.0
Bidder Name :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
(a) Dismantling of different H.P 3 Phase 380-400 Volt 1440 RPM, 4/3 pole 50 cycle for induction motors, removing old burnt out coil from slots carefully, segregating all the parts, washing and cleaning the same thoroughly for verification of serviceable and unserviceable parts as per direction of E.I.C. (ii) for 17.5/20 HP 3 phase Induction Motor.
Rewinding of approved quality Super Enamel copper winding wire of standard gauge as provided by motor manufacturer including slot insulation as per Indian Electrical Rules soldering the cable joint properly taping with 660 v grade water proof tape making new loop terminal, heating and varnishing with Class-E golden Varnish (Johnson & Nicolson Make) so as to develop original rated RPM, supplying all necessary materials as mentioned above and reassembling the 17.5/20 HP, 3 Phase, 1440 RPM, 50 Hz, 440 Volts Induction Motor.(WRDD elec. sh. chapter 4 Page-1 of 7,item -2 ) (b) 17.5 H.P / 20H.P 3 Phase 415 votls, 50 Hz 2 / 4 pole induction Motor.
(i) Supply of super enamelled dual coated copper wire conforming IS 13730, 1996, part 13 (16 swg to 22 swg) Required max. weight of super enamelled copper wire is given below: 1) Elmech/G.E.C(New) / Crompton/N.E.C/Kirloskar - 10.2kgs. 2) Bicco/ A.E.I -13.1 Kgs. 3) G.E.C (old) - 16.2 Kgs. 4)Kirloskar(New)-9.5 kg. &10.5 Kg. 5)Kirloskar (Old)- 12 Kgs. 6) Crompton (Old)-12.5 Kg. 7) NGEF-10.5 Kgs.
(ii) Labour charge for rewinding , soldering, heat varnishing, bearing changing, reassemling etc. including supply of all materials excluding bearing as mentioned above complete in all respect as per direction of E.I.C
Labour charge for checking up the dynamic balance of the motor shaft for original allignment as per direction of E.I.C
Testing of repaired motor by continuous 8 hours running on load as per direction of E.I.C.
Socketing with C.I socket at enlarged bearing housing of any type of 17.5 H.P / 20 H.P motor by oversizing the bearing housing by machine turning & suppling new socket of required size and fitting the same in bearing housing.
Painting two coats of both inner & outer portion with best quality synthetic enamel paint (to be approved before use) including smoothing surface by sand paper for removing old paint as per EIC. (b) Motor
Heat varnishing with best quality (Johnson & Johnson/ D. Beck/ Gilliander) class 'E' insulating varnish of required quantity for 3 course & uniform heating at 80 degree celcious for 48 hours with all cost of materials, labour as per deduction of EIC. © Insulating varnish 1 ltr for 20 HP induction Motor.
Item wise total
Add GST @18% on all Items
Add Cess @1% on all Items.
Deduction towards dismantled burnt enamelled copper wire from induction motor on the basis of actual measurement to be retained by the agency. (Note in case of PVC insulated copper wire to arrive at net burnt weight 10% deduction will be made) NB: Contractors premium will be allowed in this item bill should be drawn deducting the actual measurement of burnt coli @Rs 351.00 per Kg.
Grand Total Rs.
Say Rs.
Two Lakh &Fifty Six Only
Please Enable Macros to View BoQ information
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.87 MB
Tendernotice_2.pdf
PDF • 1.93 MB
BOQ_2399997.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid