Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.6 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹14.4 L+₹80,177 (5.90%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹14.7 L+₹1.1 L (7.93%)Rejected-Finance H NO 01 MADINA BAGH MEHJOOR NAGAR NEAR HOTEL RAFADA SRINAGAR 190015 J K | BUDGAM | JAMMU AND KASHMIR | 190015 | L3 | Rejected-Finance Other than lowest |
Tender Value
₹14 L
EMD Value
₹28,000
Closing Date
3 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(I) 873 EWS
Garrison Engineer (Indep) 873 Engineer Works Section PIN 913 873 C/O 56 APO
PROVN OF 100 KVA TRANSFORMER AND ASSOCIATED WORKS AT CHANDERKOT UNDER GE (I) 873 EWS
2022_MES_549949_1
NIT-49 of 22-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Bhaderwah
As per NIT
7 documents required · 7 mandatory
₹500
GE(I) 873 EWS
₹28,000
Yes
11 Oct 2022
5 Sept 2022
6 Oct 2022
5 Sept 2022
3 Oct 2022
19 Sept 2022
Amount
Excavating in trenches, not exceeding 1.5metre wide and not exceeding 1.5metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed.
Excavating in trenches, not exceeding 1.5metre wide and exceeding 1.5metre depth but not exceeding 3.0metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick any type of soil, complete all as specified and directed.
Removing excavated soils to a distance exceeding 50m but not exceeding 100m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Cement concrete type D-2 1:4:8 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed.
Cement concrete type B-1 1:2:4 (using 20mm graded crushed stone aggregate) as in coping of poles, complete all as specified and directed.
Lightning arrestor expulsion type, consisting of multiple spark gaps in series with one or more non-linear resistor to limit voltage surge on AC power circuit to interrupt power flow current suitable for outdoor installation and exposed direct to sun with ambient temperature between (-) 10° C to (+) 50° C suitable for surge discharge capacity 65 KA, 11000 Volts grade conforming to IS-4350 complete with all fittings, complete all as specified and directed.
Steel Tubular swaged poles type 410 SP-31 (9.0 mtr long) conforming to IS : 2713 Part-I to III 1980, complete with 6 mm thick mild steel base plate, finial taper plug, MS bolts, nuts, screws including painting upto 1.5metre above PCC coping in black and white strips 05 Nos of 30cms each starting from the bottom of the pole and two coats epoxy based paint aluminium grade finish to the remaining external surface over one coat of primer complete all as specified and as directed.
Cross arm bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, drilling holes for bolts, in any shape or size as indicated or directed and also inclusive of two coats of aluminium paint over one coat of red oxide primer all as specified and as directed.
Aluminium conductor steel reinforced (ACSR) including binding to insulator with suitable size of binding wire and size of conductor Weasel (6/1 x 2.59 mm), Squirrel (6/1 x 2.11mm) or Ferret (6/1 x 3.00 mm) all as specified and as directed.
Pin type porcelain, vitreous white, brown or green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 150mm height, 150mm dia for 11000 volt complete all as specified and directed.
Disc type insulator, porcelain, vitreous, white, brown or green including one galvanised mild steel spindle, two galvanised 145 mm height 255 mm dia for 11000 Volts grade complete all as specified and directed.
Air break, gang operated with 15 Nos insulators outdoor type, mechanically operated suitable for horizontal or vertical mounting, fixed type, mounted on insulator and steel frame with operating mechanism worked from ground level, provided with locking arrangement for operating handle, consisting of MS channel, HT post type insulator, contacts of copper alloy, high pressure, heavy duty contact assemble, operating rod of 25mm dia GI pipe medium grade, drop out expulsion assemble of phases fuses etc conforming to IS : 1018 of 1972 with continuous current rating with 15 insulators of current rating upto 400 amps 11000 volts grade, complete all as specified and directed.
Supply installation, testing and commissioning of 11 KVA (HT) Trivector Meter complete with required wiring system from metre to CT & PT, complete all as specified and directed. Make : L & T Model No. ER300P Class 0.5 (Base mounting), Three Phase, 4W TVN 110 Volt (L-L) 1A class 0.5S BM (WR300BB 1200) or equivalent in Siemens /ABB / Legrand
Supply, installation, testing and commissioning sheet metal enclosure out door type, weather proof for energy meter, factory fabricated of 3.15mm thick CRCA sheet, compartmentalised design suitable for for down loadinf data from meter to AMRI without opening panel with suitable locking arrangement, of size not less than 0.60x0.45x0.30 metre including suitable clamp fitted to poles as required at site or as directed.
Danger notice plate of size 25 x 20 cm, made of 1.6 mm thick mild steel sheet, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with and including mild steel clamps, bolts and nuts of approved size for HT poles, complete all as specified.
Connection cable from CT/PT Unit to trivector meter with PVC insulated unsheathed FRLS cable of size 1.5sqmm x 10 core, complete all as specified and as directed.
Bus bar panel size 0.8x0.4x0.4 Mtr, KISOK, outdoor type, CRPI tested, LT 440 Volts, 50 Hz, 3 phase 4 wire supply, comprising of bus bas chamber with 4 Nos aluminium strip bus bars PVC insulated with colour coding af rating 200A, floor mounted factory fabricated weather and vermin proof protection class IP 54 made out of 1.4 thick MS sheet CRCA on angle iron 30x30x4mm frame with front opening doors, locking arrangement powder coated internally and externally, shall have channel base of appropriate size and mounted on PCC foundation of size as required or approved by manufactures in PCC 1:3:6 type C-1, using 20 mm graded crushed stone aggregate as directed by the Engr-in-Charge including earth work complete all as specified.
Supplying, installing, designing, testing and commissioning of LT outdoor type Panel Board, Factory made, (Cubical kiosk type), CPRI tested, LT 440 Volts, 50 Hz , 3 Phase 4 wire supply , floor mounted factory fabricated weather and vermin proof protection class IP 54 made out of 3.15 mm thick MS Sheet CRCA on angle iron 40X40X6mm frame of size and size of panel (1.8 x 1.2 x 0.6 mtr) suitable to incorporate following accessories with front and rear opening doors, handle type locking arrangement powder coated internally and externally, shall have channel base of appropriate size and mounted on PCC foundation of size as required or approved by manufacturers in PCC 1:3:6 type C-1 , using 20 mm graded crushed stone aggregate as recommended by manufacturer or directed by the Engr -in - charge including earth work complete comprising of following :
Incoming (a) Bus bar chamber comprising 4 Nos copper strip of size 32 x 6 mm and lenght 600mm each bus bar and having min 10 holes arrangement in each basbar strip. PVC insulated made of copper strip of size suitable for 200A current. PVC sheathed with colour coding. (b) MCCB having current ratings 250 Amps with rupturing cap 36 KA , AC 415 Volts four pole with microprocessor release complete with spreader links. - 01 No (c) Multifunctional digital panel meter with LCD display flush mounting type of size 96X96 mm, accuracy class 1, including suitable CTs with secondary current 5A, with display volt, Amp , Frequency, KWH. - 01 No (B) Outgoing (a) MCCB having current ratings 160 Amps with rupturing cap 36 KA , AC 415 Volts four pole with thermal magnetic release complete with spreader links. - 03 Nos. (b) All accessories pre-wired with suitable size PVC insulated copper conductor cables for control wiring and PVC insulated copper strips of appropriate size for power circuits as per standard engineering practice and required at site and suitable foundation for panel as per manufacturer recommendation.
Supply, installation, Commissiong and Testing Automatic Power Factor Correction Panel Board, out door type, factory made, cubical kiosk type, weather, dust and vermin proof, CPRI approved with locking arrangement, made out of CRCA sheet of 3.15mm thick with suitable size of channel for base complete with capacitor banks of capacity 50 KVAR reverse power relay 3 phase with tuned reactor for 100 KVA transformer out door type suitable for 1100 Volt 3 phase 50 Hz AC supply floor mounted, connected with suitable size thimbles / lugs, PVC insulated multi-stranded copper wire of suitable size with PVC flexible conduit medium quality as required, comprising of copper bus bar 200Amps capacity fixed on insulators to achieve power factor 0.95 and duly powder coated in siemens grey colour mounted on PCC platform of PCC 1:2:4 type B-1on angle iron frame made of 50 x 50 x 6mm thick angle iron duly marked with incoming and outgoing controls, completed all as specified and as directed comprising of the following :-
Notes for Serial Item No 18 to 20 : 1. The drawing for APFC Panel / LT Feeder Pillar Box shall be got approved by the Engineer-in-Charge. 2. The Pre-dispatch inspection of APFC Panel / LT Feeder Pillar Box shall be done by the Rep of the Accepting Officer at factory site. 3. All the existing cables shall be fixed with glands, lugs etc. of the requisite size. Makes for Serial Item No 18 to 20 : Make of Panel : DV Electromatics Private Limited / Simon Fabricators / Electricfield Co / Adhunik Switchgear / Universal Switchgear Make of MCCB & Star Delta Starter : L&T / Legrand / Schneider / Havells Make of Voltmeter / Ammeter / Multifunction Meter : SECURE / L&T (RISHAB) / C&S ELECTRIC / MECO Contactor : SECURE / L&T / ABB / SCHENEIDER / SEIMENS / LEGRAND / AE
Supply, installation, testing and commissioning of capacity 100 KVA Transformer, step-down, 11/0.433 KVA complete, outdoor type, copper wound with transformer oil of dieletric strength-45KV including tapping up and down, installing with proper connection of HT/LT side, earthing of capacity 63 KV, Three Phase, Four Wire, 50 Hz, oil immersed naturally cooled, Delta connected on primary (HV) side and star connected (LV) side, having tapping 0%, 2.5%. 5% and 7.5% on HV to be charged by means of hand operated Off Load tap changing gear including first filling of oil and all standard fitting such as breather unit, drain out valve. conservator tank and mounting, complete all as specified in IS-1180 Part-II and as directed. Make : Alstom (Areva) / Seimens / ABB / JK Transformer / Bharat Bijlee / Voltamp / Schneider
Material and labour for construction of Platform suitable for 100 KVA transformer of size 3m x 3m with 1.00m clear height from ground level, 1.00m deep foundation, 150 mm thick PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in foundation below ground level, 23cm wide brick masonry in CM 1:6 below & above ground level, hollow space to be filled hard core of size not exceeding 63 mm, deposited spread and levelled in layers not exceeding 15cm thickness, watered and well rammed with 100mm thick cement concreate 1:2:4 type B-2 as in Floor/Top of platform, brick surfaces plastered in CM 1:4 including protection with XPM, gate and chain link fencing rail around the platform with angel iron of 40 x 40 x 6mm frame upto 1.20m clear height supports grouted in PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in foundation of angle iron including excavation in any type of soil, returning filling in and removal of surplus soil to a distance 50m, complete all as specified and directed
XLPE insulated armoured heavy duty electric cable with aluminium conductor 11000 volts grade ISI marked cross sectional area 95 Sqmm 3 core, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 95 Sqmm 3.5 core, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 70 Sqmm 3.5 core, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 50 Sqmm 4 core, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 16 Sqmm 2 core, complete all as specified and as directed.
Cable Jointing Kit for HT 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm including testing and commissioning, complete all as specified and directed
Cable Jointing Kit for1.1 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 95 Sqmm including testing and commissioning, complete all as specified and directed
Supply and fixing 11KV CTPT metering unit, outdoor type, oil cooled, pole mounted, CT Ratio 5/5 Amp, Burden 10VA, class-0.5 S, STC-3 KA/1 Sec and PT Ratio 11KV/110V, Burden 0.5VA, class-0.5 S, insulation-12KV/28KV all as per IS 2705/1992 and IS 3156/1992 complete all as specified and as directed.
Sand cushioning to underground cables using new dry river sand laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete, punned to 18cm, complete all as specified and directed Note : Punned thickness of 18cms shall be measured for payment.
Supply and laying brick covering with width equal to length of bricks as mechanical protection to underground cable using old size sub class 'B' bricks, laid flat size 230mm x 115mm x 75 mm with width of brick perpendicular to length of cable, all as specified and as directed.
Steel pipe galvanised light grade, 80 mm bore laid in trenches or under ground/floor or road of fixed with pole for protection of cable including GI clamps with bolts nuts and washers complete all as specified and directed.
Steel pipe galvanised light grade, 40 mm bore laid in trenches or under ground/floor or road of fixed with pole for protection of cable including GI clamps with bolts nuts and washers complete all as specified and directed.
Cable route marker with route indication on cast iron disc of 150mm dia and 10mm thick, marked/written for "LT cable 1100 VOLTS" embosed including indication direction fixed/ bolted to 40mmx40mmx6mm thick MS angle iron support of 0.50m long embedded upto 200mm depth in concrete block of size 200mmx200mmx50omm casted in PCC 1:3:6 type C-1 including painting with two coats of synthetic enamel paint over a coat of red oxide primer to exposed steel surfaces, complete all as specified and as directed.
Earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick buried directly to ground vertically to a depth not less than 2.25 Mtr below the ground level with top edge of earth plate not less than 1.65 Mtr below normal ground level connected to GI strip 32 x 6 mm size and earthing lead protected with 50 mm bore GI pipe, light grade, filling around with charcoal dust and salt including excavation, returning, filling of earth and disposal of surplus soil to a distance not exceeding 50 mtr and connected to GI strip by means of GI nuts, bolts and washers strip connected to earth plate including chamber PCC 1:3:6 type C-1 using 20mm graded crushed stone aggregate in concrete pit pre-cast RCC 40 mm thick reinforced with 6 mm dia round at 75 mm C/C both way with 12 mm dia mild steel plain bar lifting handle 2 Nos funnel with wire mesh 20 mm dia GI pipe light grade watering pipe and frame work complete all as shown in electrical plate No. 3 of SSR Part-I 2009 including testing on completion complete all as specified and as directed.
Galvanised Iron earthing strip 32 x 6 mm from earth test point to electrical equipment complete all as specified and directed
Galvanised Iron earth wire 4 Sqmm from earth test point to electrical equipment including taking down old unserviceable earth wire complete all as specified and directed
Earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 1.5 meter (BGL) connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore “light grade” galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt, complete all as shown in EP No 3 of SSR 2009 Part-I, connected to test point complete, all as specified and testing on completion.
M/S Builders Indias
M/S BALI CONSTRUCTIONS
Bidder Name
M/S BALI CONSTRUCTIONS
SWASTIK TRADERS
M/S Builders Indias
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .