EXECUTIVE ENGINEER (E) PWD EMD SOUTH WEST
O/o Executive Engineer (E) PWD EMD South West Brar Square near Delhi Cantt Metro Station New Delhi
Servicing and problem diagnosis of transformer HT and LT panel
2026_PWD_297824_1
2/NIQ/2026-27
Open Tender
Electrical Works
Percentage
5 days
works
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
Exempted
8 Sept 2026
1 Sept 2026
7 Sept 2026
1 Sept 2026
7 Sept 2026
1 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Servicing of 3 x 1000 KVA Transformer of Kirloskar make as per detail mentioned below etc complete as reqd.
a) Complete visual inspection of transformer, bushings, cable terminations and accessories.
b) Cleaning of transformer body, bushings, terminals and associated components.
c) Checking of all electrical connections, terminals, lugs and tightening of connections.
d) Inspection of HV/LV bushings for cracks, carbon deposits, overheating or damage.
e) Checking of temperature indicators, protection devices and alarm/trip circuits.
f) Measurement of winding insulation resistance using a suitable insulation resistance tester.
g) Winding resistance testing, as applicable.
h) Checking of earthing connections and continuity.
i) Checking of cooling system, fans and control circuits, wherever provided.
j) Functional checking of transformer protection and indication circuits.
k) Final testing and preparation of service/testing report | 3 | Job | 16,284 | ₹48,852 |
| 2 | Servicing of HT panel & relay calibration of crompton greaves make as per detail mentioned below etc complete as reqd.
a) Complete visual inspection and cleaning of HT panel.
b) Cleaning of VCB, Bus-Bars, Insulators, Cable Compartments and Panel Interiors.
c) Checking and tightening of busbar, cable and control wiring connections.
d) Inspection of VCB mechanism, contacts, shutters and interlocks.
e) Lubrication of operating mechanism.
f) Checking of VCB ON/OFF/TRIP operation.
g) Checking of spring charging mechanism and electrical/mechanical interlocks.
h) Inspection of CTs, PTs, fuses and associated wiring.
i) Checking of protection relay, auxiliary relays and indication circuits.
j) Checking of trip and closing circuits.
k) Verification of relay settings as per approved/system requirements.
l) Testing of over-current and earth-fault protection circuits.
m) Checking of metering instruments and indications.
n) Insulation resistance testing of relevant circuits.
o) Checking of panel earthing and continuity.
p) Functional testing and simulation of trip circuits
q) Final operational testing and submission of service/testing report | 4 | Job | 4,885 | ₹19,540 |
| 3 | Servicing of LT ACB as per detail mentioned below etc complete as reqd.
a) Complete visual inspection and cleaning of LT ACB and cradle.
B) Cleaning of main contacts, arcing contacts and contact assemblies.
C) Inspection of fixed and moving contacts for burning, pitting or excessive wear.
D) Checking and tightening of power and control terminals.
e) Checking of ACB operating mechanism.
f) Checking of charging motor and spring charging mechanism.
g) Checking of closing and tripping coils.
h) Checking of undervoltage release/shunt trip, wherever provided.
i) Checking of electrical and mechanical interlocks.
j) Checking of ON/OFF/TRIP indications
k) Inspection and servicing of ACB cradle, racking mechanism and shutters.
l) Checking of auxiliary contacts and control wiring.
m) Checking of protection/overcurrent release unit and its settings.
n) Functional testing of ACB closing, opening and tripping operations.
o) Checking of trip circuit and emergency/manual trip operation.
p) Insulation resistance testing as applicable.
r) General tightening, lubrication and minor rectification.
s) Final operational testing and submission of service report | 24 | Job | 2,171 | ₹52,104 |
| 4 | Testing and Problem Diagnosis of transformer as per detail mentioned below etc complete as reqd. a) Complete visual inspection of the transformer for abnormal condition, overheating, noise, vibration or burning smell. B) Checking of HV and LV cable terminations and connections. c) Insulation Resistance (IR) testing between: d) HV–LV e) HV–Earth f) LV–Earth g) Winding resistance testing of all phases. h) Transformer Turns Ratio (TTR) testing, wherever applicable. i) Checking of phase-to-phase electrical parameters and balance. j) Checking of transformer earthing and neutral earthing connections. k) Checking of transformer protection devices, including temperature relay, alarm/trip circuits and other available protections. l) Checking of transformer input/output voltage and current. m) Checking for abnormal heating, humming/noise and other symptoms reported at site. j) Checking of associated control and indication circuits. k) Analysis of test results to identify the possible cause of the reported problem. l) Identification of defective/abnormal components, if any. m) Recommendation for further repair or replacement based on test observations. n) Preparation and submission of a detailed testing and fault-diagnosis report. o) Note: Major repair work, winding repair, replacement of bushings, protection relays or other defective components shall be carried out/charged separately after approval. | 1 | Job | 19,541 | ₹19,541 |
| 5 | Installation of PT in Main Incoming as per detail mentioned below etc complete as reqd.
a) Supply and installation of suitable Potential Transformer (PT) in the main incoming HT panel, as per system voltage and existing panel arrangement.
b) Arrangement and mounting of PT inside the existing HT panel.
c) Installation of necessary mounting supports, clamps and hardware.
d) Connection of PT primary side to the HT incoming circuit through suitable protection/fuse arrangement, as applicable.
e) Connection of PT secondary wiring to the metering, protection and indication circuits.
f) Proper termination, ferruling and identification of PT secondary wiring.
g) Checking of PT secondary fuse/MCB and associated protection circuit.
h) Checking and termination of PT earthing connections.
i) Verification of PT polarity and phase sequence.
j) Checking of PT secondary voltage and output.
k) Testing of PT circuit for correct voltage indication and metering operation.
l) Checking of insulation and control wiring associated with the PT.
m) Functional testing of the complete PT circuit after installation.
n) Restoration of the HT panel and final operational checking.
o) Submission of installation/testing report after completion | 1 | Job | 70,564 | ₹70,564 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.86 MB
BOQ_396878.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .