Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹10,000
Closing Date
19 Jun 2020, 12:00 pmClosed
SE
Pallavpuram
11 and 33 kv line shifting work due to exstension of road Nanu-sardhana Road
2020_PVVNL_480563_1
56/EDC-2/MT/2020-21
Open Tender
Electrical Works
Item Rate
30 days
Meerut
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
SE EDC-2
₹10,000
6 Jul 2020
6 Jun 2020
19 Jun 2020
6 Jun 2020
19 Jun 2020
6 Jun 2020
Amount
Shifting of 11/33 KV Lines under Deposit Scheme Work :-
Cartage of following from store center Meerut to dump site including loading & unloading at both ends maximum distance up to 30 Km :– A) STP pole 11 mtr long 11 Mtr Long.
B) PCC pole 8.5 mtr long / 9 Mtr Long.
Cartage of following from dump site to site of work on day to day basis including loading & unloading at both ends maximum distance up to 20 Km :-A) STP pole 11 mtr long 11 Mtr Long.
B) PCC pole 8.5 mtr long / 9 Mtr Long.
Cartage of line material such as ACSR Dog conductor, 33 kv X arm, disc insulator, pin insulator, stay set, top channel, proper channel, MS angle, GI wire etc from store centre to dump site including loading & unloading at both ends maximum distance up to 30 Km.
Cartage of line material such as ACSR Dog conductor, 33 kv X arm, disc insulator, pin insulator, stay set, top channel, proper channel, MS angle, GI wire etc from dump site to site of work on day to day basis, including loading & unloading at both ends maximum distance up to 20 Km.
Erection of Four Pole suitable for 33 kv line on STP pole (11 mtr. long) after digging a pits of required size with fixing line accessories complete..
Erection of Try Pole suitable for 33 kv line on STP pole (11 mtr. long) after digging a pits of required size with fixing line accessories complete..
Erection of Double Pole suitable for 33 kv line on STP pole (11 mtr. long) after digging a pits of required size with fixing line accessories complete..
Erection of Single Pole suitable for 33 kv line on STP pole (11 mtr. long) after digging a pits of required size with fixing line accessories complete..
Erection of Double Pole suitable for 11 kv line on PCC pole (8.5 mtr. long) after digging a pits of required size with fixing of all line accessories complete work in all respects.
Erection of Single Pole suitable for 11 kv line on PCC pole (8.5 mtr. long) after digging a pits of required size with fixing line accessories complete..
Fabrication & fixing of MS Angle of size 65x65x6 Sq.mm for Bracing of Four pole. & Try Pole 33 KV Line.
Fabrication & fixing of MS Channel of size 125x65x3200Sq.mm on Four pole of 33 KV Line.
Fabrication & fixing of MS Channel of size 125x65x3200Sq.mm on Try pole. 33 KV Line.
Fabrication & fixing of MS Channel of size 125x65x3200Sq.mm on Double pole. 33 KV Line.
Fabrication & fixing of 33 KV Line Accessories on STP Pole Complete.
Fabrication & fixing of Double pole (PCC pole) for 11 KV line Accessories complete.
Fabrication & fixing of Single pole (PCC pole) for 11 KV Line Accessories complete.
Grouting of STP pole with Stone Blast, Dust & Cement.
Grouting of PCC pole with Stone Blast, Dust & Cement.
Fabrication & fixing of Guarding MS Angle.of size 65x65x6 Sq.mm.
Laying lifting, sagging & binding laces at equal distance properly for Proper Guarding by 8 SWG GI wire.
Laying lifting, sagging & binding properly of ACSR dog conductor suitable for 33 kv line.
Laying lifting, sagging & binding properly of ACSR weasel conductor suitable for 11 kv line.
Making proper jumpering of Four pole of 33 kv line.
Making proper jumpering of Try pole of 33 kv line.
Making proper jumpering of Double pole of 33 kv line.
Making proper jumpering of Double pole of 11 kv line.
Grouting & fixing of stay set suitable for 33 Kv line
Grouting & fixing of stay set suitable for 11 Kv line
Dismantling of 33 KV line accessories after opening of all bindings & Jumpering .
Removal of ACSR Dog conductor of 33 KV Line and making coil ACSR Dog conductor
Dismantling of STP pole of 33 KV old line
Dismantling of 11 KV line after opening of all accessories and making coil of ACSR Weasel conductor. 648 Meter.
Dismantling of PCC pole of 11 KV line
Earthing of 11 KV line complete.
Providing & fixing of Nut & Bolt for 33 KV line
Providing & fixing of Nut & Bolt for 11 KV line
Providing & fixing of MS Clamp suitable for 33 KV line-F Clamp
Providing & fixing of MS Clamp suitable for 33 KV line-Holding Clamp
Providing & fixing of MS Clamp suitable for 33 KV line-Stay Clamp
Providing & fixing of MS Clamp suitable for 11 KV line-F Clamp
Providing & fixing of MS Clamp suitable for 11 KV line-Holding Clamp
Providing & fixing of MS Clamp suitable for 11 KV line-Stay Clamp
Cutting & Chopping of Tree branches of 33 KV line
Cutting & Chopping of Tree branches of 11 KV line
Providing & fixing of Danger Plate with clamp
Providing & fixing of Number Plate with clamp
Back Cartage of old line material from site to JE Store on day to day basis of 33 KV line accessroes as follows :- A) STP pole
B) ACSR Dog Conductor
C) 33 KV Cross Arm
D) Disc Insulator
E) Pin Insulator
Back Cartage of old line material from site to JE Store on day to day basis of 11 KV line accessroes as follows:- A) PCC pole
B) ACSR Weasel Conductor
Back Cartage of old line material from JE Store to Central Store, Meerut 33 KV line accessroes as follows:-. A) STP pole
B) ACSR Dog Conductor
C) 33 KV Cross Arm
D) Disc Insulator
E) Pin Insulator
Back Cartage of old line material from JE Store to Store Centre, Meerut of 11 KV line accessroes as follows:- A) PCC pole
B) ACSR Weasel Conductor
SATISH ELECTRICALS
RISHIPAL SINGH CONTRACTOR
M/s Faisal Electricals
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .