| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹20.1 LAccepted-AOC 12 BHARTI AARTIST COLONY VIKAS MARG NEW DELHI 110092 | EAST | DELHI | 110092 | L-1 | Accepted-AOC Lowest Bidder | |
| 2 | L-2₹21.6 L+₹1.4 L (7.14%)Rejected-Finance 1ST FLOOR H NO 165 GALI NO 16 S B S COLONY KARAWAL NAGAR DELHI EAST DELHI DELHI 110094 | NORTH EAST DELHI | DELHI | 110094 | L-2 | Rejected-Finance Other than Lowest | |
| 3 | L-3₹23.1 L+₹2.9 L (14.6%)Rejected-Finance D1C 47A JANAK PURI NEW DELHI 110058 | NEW DELHI | DELHI | DELHI | 110058 | L-3 | Rejected-Finance Other than Lowest | |
| 4 | L-4₹30.6 L+₹10.4 L (51.7%)Rejected-Finance C O KHASRA NO 483 KALSHUM AKHTAR PANCHAYAT KAHYTAR MALAD MORH REHMBAL UDHAMPUR 182121 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182121 | L-4 | Rejected-Finance Other than Lowest | |
| 5 | L-5₹31.4 L+₹11.3 L (56.1%)Rejected-Finance HYDERPORA NEAR ELLAQUAI DEHATI BANK SRINAGAR KASHMIR J K 190014 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190014 | L-5 | Rejected-Finance Other than Lowest |
| Sl No | Description | Qty | Unit | R. S. Associates L2 | Pradeep Bros L3 | Vijaypower Generators Limited L1 | M/S M.Y Enterprises L8 | A K ENTERPRISES ENGINEER CONTRACTOR AND GEN ORDER SUPPLIERS L4 | M/S ZAHOOR AHMAD KHAN L5 | M/s Jaipal Associates L7 | M/S A.R TANTRAY L6 | Natwadia Electrical Company L9 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Supply, Installation, testing and commissioning of Retrofit Emission Control Device for diesel generator of any make / vintage / category of the following capacities :- Application:- Reduce particulate matter (PM 2.5), Carbon Monoxide and Hydrocarbons emitted from Diesel Engine. Technology / Type:- PRT (Passive Regenerative Trap), Wet Scrubbing, Diesel Oxides Catalyst Guaranteed specified Particulate matter (PM 2.5) Carbon Monoxide, Hydrocarbon reduction efficiency (Min) 70% for all DG sets. Scope of Installation :- a) Installation of Emission Control Retrofit Device when offered by the vendor is inclusive in the scope of supply and shall be done by the seller/ OEM. b) Construction of suitable earthing station and necessary connections shall be done by the seller. c) Warranty/Service :- 12 months d) Number of preventive maintenance visits offered during warranty period will be 2 visits. it will cater filter cleaning and replacement of filter, pressure and temperature sensor, display unit fitted for RECD if necessitated. | ||||||||||||
| 1.00Back Pressure due to the Emission Control retrofit device :- Maximum back pressure exerted by the Emission Control retrofit device at max prescribed load by DG OEM(as per the capacity of the DG set). TEST REPORTS Certification :- The device must be 'Type Approved' in accordance with the Central Pollution Control Board's System and Procedure for Emission Compliance Testing of Retro-fit Emission Control Devices (RECD) for Diesel Power Generating Set Engines, dated 01/02/2022, as well as provide a type testing certificate for all KVA families of required generators. Adhering to this, RECD to be ‘Type Tested’ for an equivalent kVA family as per the System and Procedure from any one of the four Central Pollution Control Board, Govt, of India, recognized/approved test agencies / laboratories as given below: (a) Automotive Research Association of India (ARAI, Pune) (b) International Centre for Automotive Testing (ICAT, Manesar) (c) Indian Institute of Petroleum (IIP, Dehradun) (d) Vehicle Research Development Establishment (VRDE, Ahmednagar): | ||||||||||||
| 1.00General Technical Requirements (GTR) / Commissioning:- a) Emission control retrofit device shall be complete with safety precaution to ensure no damage should be done to the DG set operations under any circumstance. The Emission control retrofit device should be closely coupled with the DG exhaust to ensure 100% of the exhaust passes through the Emission control retrofit device. b) Anti vibration mountings shall be provided for complete Emission control retrofit device in case of flexible coupling with the DG exhaust c) Emission control retrofit device should have protection against under voltage, over voltage, under frequency ,over frequency, low battery voltage, over current, earth fault, short circuit ,phase sequence change etc d) The Emission control retrofit device shall be with corrosion resistive and HR paint. e) Unloading and placement of the Emission control retrofit device at the time of delivery is in the scope of work. f) The contractor shall provide the trail of the Emission control retrofit device at least two hours on site. | ||||||||||||
| 1.00g) All exhaust piping, any extra work, distribution board shall be provided by the contractor in the scope of work. h) contractor shall provide the pollution test report of DG set before and after installing the RECD. Make : CPCB / ARAI / ICAT certified manufacturer of RECD: Cummins Technologies India Pvt Ltd / Chakr Innovation Pvt Ltd / JBDS Power Project / Platino Automotive Pvt Ltd / Pi Green Innovation Pvt Ltd j) The bidder / RECD OEM must submit valid CPCB type approval certificates for DG sets covering the specified engine power ranges (in KW) under CPCB Stage-1 and Stage-2 norms. A variation of upto + 3% in the certified rating is acceptable. h) The supply RECD system should be capable of operating efficiency at ambient temperature of (-) 15 C and above. | ||||||||||||
| 1.01 | 250 KVA capacity DG Set. | 1 | Each Job | 4,71,200 ₹4,71,200 | 4,58,150 ₹4,58,150 | 4,45,002 ₹4,45,002 Lowest | 8,55,000 ₹8,55,000 | 4,50,000 ₹4,50,000 | 6,00,000 ₹6,00,000 | 8,30,000 ₹8,30,000 | 6,50,000 ₹6,50,000 | 9,00,000 ₹9,00,000 |
| 1.02 | 200 KVA capacity DG Set. | 1 | Each Job | 3,87,500 ₹3,87,500 | 3,73,150 ₹3,73,150 | 3,61,002 ₹3,61,002 Lowest | 7,55,000 ₹7,55,000 | 6,20,000.99 ₹6,20,000.99 | 5,50,000 ₹5,50,000 | 7,10,000 ₹7,10,000 | 5,50,000 ₹5,50,000 | 7,00,000 ₹7,00,000 |
| 1.03 | 160 KVA capacity DG Set. | 1 | Each Job | 3,19,000 ₹3,19,000 | 3,00,050 ₹3,00,050 Lowest | 3,02,300 ₹3,02,300 | 6,25,000 ₹6,25,000 | 5,60,000 ₹5,60,000 | 4,50,000 ₹4,50,000 | 6,05,000 ₹6,05,000 | 4,30,000 ₹4,30,000 | 5,50,000 ₹5,50,000 |
| 1.04 | 125 KVA capacity DG Set. | 1 | Each Job | 2,43,500 ₹2,43,500 | 2,20,150 ₹2,20,150 Lowest | 2,27,000 ₹2,27,000 | 5,20,000 ₹5,20,000 | 3,35,000 ₹3,35,000 | 4,25,000 ₹4,25,000 | 5,05,000 ₹5,05,000 | 3,80,000 ₹3,80,000 | 4,50,000 ₹4,50,000 |
| 1.05 | 82.5 KVA capacity DG Set. | 1 | Each Job | 2,05,000 ₹2,05,000 | 1,77,650 ₹1,77,650 Lowest | 1,86,000 ₹1,86,000 | 4,00,000 ₹4,00,000 | 2,81,000 ₹2,81,000 | 3,50,000 ₹3,50,000 | 3,80,000 ₹3,80,000 | 3,50,000 ₹3,50,000 | 4,00,000 ₹4,00,000 |
| 1.06 | 62.5 KVA capacity DG Set. | 2 | Each Job | 1,80,000 ₹3,60,000 | 3,05,050 ₹6,10,100 | 1,68,550 ₹3,37,100 Lowest | 2,75,000 ₹5,50,000 | 2,15,000 ₹4,30,000 | 2,85,000 ₹5,70,000 | 3,00,000 ₹6,00,000 | 3,20,000 ₹6,40,000 | 3,00,000 ₹6,00,000 |
Tender Value
₹43.6 L
EMD Value
₹87,300
Closing Date
9 Jun 2026, 6:00 pmClosed
GE (AF) Srinagar
Garrison Engineer (AF) Air Force Station Srinagar 190 007
PROVISION OF AMF PANEL AND RETROFIT EMISSION CONTROL DEVICE FOR DG SETS AT VARIOUS LOCATIONS AT AF STN UNDER GE (AF) SRINAGAR
2026_MES_766458_1
GE (AF)/SGR-02/2026-27
Open Tender
Civil Works
Item Rate
180 days
AOR of GE (AF) Srinagar
Please refer NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE (AF) Srinagar
₹87,300
Yes
8 Jul 2026
19 May 2026
11 Jun 2026
19 May 2026
9 Jun 2026
2 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply, Installation, testing and commissioning of retrofit emission control device for diesel generator of any make / vintage / category of the following capacities :- Application:- Reduce particulate matter (PM 2.5), Carbon Monoxide and Hydrocarbons emitted from Diesel Engine. Technology/Type:- ESP (Electrostatic Precipitator), Wet Scrubbing, Diesel Oxides Catalyst Guaranteed specified Particulate matter (PM 2.5) Carbon Monoxide, Hydrocarbon reduction efficiency (Min) 70% for all DG sets. Scope of Installation :- a) Installation of Emission Control Retrofit Device when offered by the vendor is inclusive in the scope of supply and shall be done by the seller/ OEM. b) Construction of suitable earthing station and necessary connections shall be done by the seller. c) Warranty/Service :- 12 months d) Number of preventive maintenance visits offered during warranty period will be 2 visits. it will cater filter cleaning and replacement of filter, pressure and temperature sensor, display unit fitted for RECD if necessiated. | |||||
| 0.999 | Back Pressure due to the Emission Control retrofit device :-
Maximum back pressure exerted by the Emission Control retrofit device at max prescribed load by DG OEM(as per the capacity of the DG set).
TEST REPORTS
Certification :-
The device must be 'Type Approved' in accordance with the Central Pollution Control Board's System and Procedure for Emission Compliance Testing of Retro-fit Emission Control Devices (RECD) for Diesel Power Generating Set Engines, dated 01/02/2022, as well as provide a type testing certificate for all KVA families of required generators.
Adhering to this, RECD to be ‘Type Tested’ for an equivalent kVA family as per the System and Procedure from any one of the four Central Pollution Control Board, Govt, of India, recognized/approved test agencies / laboratories as given below:
(a) Automotive Research Association of India (ARAI, Pune)
(b) International Centre for Automotive Testing (ICAT, Manesar)
(c) Indian Institute of Petroleum (IIP, Dehradun)
(d) Vehicle Research Development Establishment (VRDE, Ahmednagar): | - | - | - | - |
| 0.000 | General Technical Requirments(GTR)/Commissioning:-
a) Emission control retrofit device shall be complete with safety precution to ensure no damage should be done to the DG set operations under anycircumstance.The Emission control retrofit device should be closely coupled with the DG exhaust to ensure 100% of the exhaust passes through the Emission control retrofit device.
b) Anti vibration mountings shall be provided for complete Emission control retrofit device in case of flaxible coupling with the DG exhaust
c) Emission control retrofit device should have protection against under voltage,over voltage,under frequency ,over frequency,lowbattery voltage,over current,earth fault,short circuit ,phase sequence change etc
d) The Emission control retrofit device shall be with corrosion resistive and HR paint.
e) Unloading and placement of the Emission control retrofit device at the time of delivery is in the scope of work.
f) The contractor shall provide the trail of the Emission control retrofit device at least two hours on site. | - | - | - | - |
| 0.999 | g) All exhaust piping, any extra work, distribution board shall be provided by the contractor in the scope of work.
h) contractor shall provide the pollution test report of DG set before and after installing the RECD. Make : CPCB / ARAI / ICAT certified manufacturer of RECD: Cummins Technologies india Pvt Ltd / Chakr innovation Pvt Ltd / JBDS Power Project / Platino Automotive Pvt Ltd / Pi Green Innovation Pvt Ltd and equivalent. | - | - | - | - |
| 1.01 | 250 KVA capacity DG Set. | 1 | Each Job | - | - |
| 1.02 | 200 KVA capacity DG Set. | 1 | Each Job | - | - |
| 1.03 | 160 KVA capacity DG Set. | 1 | Each Job | - | - |
| 1.04 | 125 KVA capacity DG Set. | 1 | Each Job | - | - |
| 1.05 | 82.5 KVA capacity DG Set. | 1 | Each Job | - | - |
| 1.06 | 62.5 KVA capacity DG Set. | 2 | Each Job | - | - |
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.12 MB
02Tender.pdf
Tender Documents • 1.01 MB
BOQ_858403.xls
BOQ • 0.45 MB
A02.pdf
PDF • 0.13 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .