| Sl No | Description | Qty | Unit | Raj Engineering Co. L1 | MITTAL TRADING COMPANY L2 |
|---|---|---|---|---|---|
| 1.00 | Supply of CIDF 200 mm Sluice Valve, non rising spindle and rating PN-1.0. Make:- Kirloskar/IVC/Any DJB approved make. | 6 | Nos. | 2,22,000 ₹2,61,960 | 1,50,000 ₹1,77,000 Lowest |
| 2.00 | Supply of CIDF 250 mm Sluice Valve, non rising spindle and rating PN-1.0. Make:- Kirloskar/IVC/Any DJB approved make. | 2 | Nos. | 1,08,000 ₹1,27,440 | 60,000 ₹70,800 Lowest |
| 3.00 | Supply of CIDF 200 mm Non Return Valve and rating PN-1.0. Make:- Kirloskar/IVC/Any DJB approved make. | 2 | Nos. | 74,000 ₹87,320 | 44,000 ₹51,920 Lowest |
| 4.00 | Supply of M.S. Pipe of size 200 mm dia. and thickness 8 mm | 8 | Mtr. | 31,200 ₹36,816 | 16,000 ₹18,880 Lowest |
| 5.00 | Supply of M.S. flange of size 200 mm dia. | 8 | Nos. | 6,080 ₹7,174.4 Lowest | 12,000 ₹14,160 |
| 6.00 | Supply of M.S. Pipe of size 250 mm dia. and thickness 8 mm | 4 | Mtr. | 16,400 ₹19,352 | 12,000 ₹14,160 Lowest |
| 7.00 | Supply of M.S. flange of size 250 mm dia. | 4 | Nos. | 5,400 ₹6,372 Lowest | 10,000 ₹11,800 |
| 8.00 | Supply of nut bolts & washer | 60 | Kg. | 6,600 ₹7,788 Lowest | 6,600 ₹7,788 Lowest |
| 9.00 | Supply of 75 % Neoprene Rubber packing sheet. Make:-Jyoti/Deepjyoti/ Any DJB approved make. DJB Item code 22.6.2 | 30 | Kg. | 3,300 ₹3,894 Lowest | 10,500 ₹12,390 |
| 10.00 | Disconnecting all electric connections and decoupling the motor from the pump and pump from suction and delivery system by using gas cutter set and manual labour. | 2 | Jobs | 11,000 ₹12,980 Lowest | 20,000 ₹23,600 |
Tender Value
Refer Docs
EMD Value
₹17,900
Closing Date
17 Dec 2025, 3:00 pmClosed
EXECUTIVE ENGINEER (EM) M-11
GREATER KAILASH, PART-I, NEW DELHI
Strengthening of pump set and other allied works at Bapu Park Kotla BPS.
2025_DJB_282454_13
NIT No. 18/EE(EM)M-11/(25-26)
Open Tender
Electrical Work/ Equipment
Works
30 days
EXECUTIVE ENGINEER (E/M) M-11
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Delhi Jal Board
₹17,900
Yes
7 Feb 2026
6 Dec 2025
17 Dec 2025
6 Dec 2025
17 Dec 2025
6 Dec 2025
Supply of CIDF 200 mm Sluice Valve, non rising spindle and rating PN-1.0. Make:- Kirloskar/IVC/Any DJB approved make.
Supply of CIDF 250 mm Sluice Valve, non rising spindle and rating PN-1.0. Make:- Kirloskar/IVC/Any DJB approved make.
Supply of CIDF 200 mm Non Return Valve and rating PN-1.0. Make:- Kirloskar/IVC/Any DJB approved make.
Supply of M.S. Pipe of size 200 mm dia. and thickness 8 mm
Supply of M.S. flange of size 200 mm dia.
Supply of M.S. Pipe of size 250 mm dia. and thickness 8 mm
Supply of M.S. flange of size 250 mm dia.
Supply of nut bolts & washer
Supply of 75 % Neoprene Rubber packing sheet. Make:-Jyoti/Deepjyoti/ Any DJB approved make. DJB Item code 22.6.2
Disconnecting all electric connections and decoupling the motor from the pump and pump from suction and delivery system by using gas cutter set and manual labour.
Dismantling the pump set from the base frame by cutting of rusted M.S nut bolts and foundation bolts by gas cutter set and electric welding machine, removing all the nut bolt and worm out M.S Base frame from the RCC foundation suction and delivery side by gas cutter set and electric welding set job also includes dismantling the suction & delivery side sluice valve, NRV, taper bend etc. as per side requirement and lifting of pump and motor on ground level.
Braking of RCC foundation by pneumatic power hammer chisel and electric compressor machine etc. the job includes removing the broken material from P/H and disposing the same at suitable place.
Making of RCC foundation of size 2.5 mtr X 1mtr X0.9m by 1:2:4 concrete including providing fixing of 4 nos. foundation bolt of size 25mm X300mm
Providing & fixing of M.S base frame 1.5mtrX .42mtr made out of heavy duty ISMC 125X65mm, ISMC 100X50mm, and Angle 50X6mm as per existing base frame on the RCC foundation the job includes proper leveling and alignment.
Dismantling and re-Installation, erecting, testing, and commissioning of 6 Nos. of 200 mm dia. Sluice valve, 2 Nos. of 250 mm dia. Sluice valve, 2 Nos. of 200 mm dia. Non Return Valve, replacement of 250 mm dia suction line and replacement of 200 mm dia delivery line and other accessories, with necessary required all sundry items for completion of work. Installation work includes labour like fitter, welder, cutter, helper, beldar, chowkidar, supervisor, and electrician and material like welding machine, cutter set, welding rod, nut bolt with washer, packing sheet etc. The work includes cartage, loading, unloading of material, adequate safety provision, pumping out water caused during the dismantling and installation work. Testing and commissioning of line as per satisfaction of Engineer In-charge. Firm has to complete the work in all respect against this no extra payment given to the firm.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.37 MB
BOQ_373261.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .