Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.6 LAccepted-AOC BIRSINGHPUR | L1 | Accepted-AOC after snap bidding and delete some item | |
| 2 | L2₹55.0 L+₹4.0 L (7.88%)Rejected-AOC HIG 20 KATGHORA S V B P NAGAR JAMNIPALI JAMNIPALI VILLAGE TOWN KORBA CITY KORBA KORBA CHHATTISGARH 495450 INDIA | KORBA | CHHATTISGARH | 495450 | L2 | Rejected-AOC l2 bidder |
Tender Value
₹75.0 L
EMD Value
₹1.9 L
Closing Date
27 Apr 2019, 3:30 pmClosed
SE PnW, SSTPP
O/o SE PnW, IIIrd Floor Admin Building SSTPP
Overhauling of TG auxiliaries including cleaning of coolers, tanks strainers, servicing of pumps/ replacement of various valves and associated works of unit no.1 and 2, 2X600MW at SSTPP, MPPGCL, Dongalia
2019_MPPGC_19923_1
WT-789
Open Tender
Miscellaneous Works
Lump-sum
30 days
SSTPP, Dongalia
Please refer Tender documents.
14 documents required · 14 mandatory
₹2,000
Payable To
₹1.9 L
Yes
7 Aug 2020
16 Mar 2019
29 Apr 2019
16 Mar 2019
27 Apr 2019
16 Mar 2019
CLEANING OF STRAINERS
BP Suction Strainer 1250 X 700 (L X OD)
BFP Suction Strainer 2410 X 400 (L X OD)
ACW Self Cleaning Strainer 1500 X 1000 (L X OD)
CEP Suction Strainer 1080 X 700 (L X OD)
Debris Filters of CW System 2200 mm Dia.
CLEANING OF TANKS
Main Oil Tank 6120 X 6120 X 3120 (L X W X H)
TDBFP Oil Tank 3600 X 2520 X 2140 (L X W X H)
Overhead Make-up Water Tank 4000 X 4000 X2500(L X OD)
Hotwell Cleaning 3000X 1730X 14550 X (L X OD)
Feed Storage Tank 29880 X 3600 (L X ID)
Dearator 10500X 10815 (L X OD)
Condensate Storage Tank 3600X 2520 X 2140(L X ID)
Clean Oil dirty oil tank
CLEANING OF PLATE TYPE HEAT EXCHANGER
Corrugated SS Plate Type Heat Exchanger(SG) 1390X1000X2830 (LXWXH)
Corrugated SS Plate Type Heat Exchanger(TG) 2010X1000X2830 (LXWXH)
CLEANING OF COOLERS
TDBFP Lube Oil Cooler Size- 3800X 512
MDBFP Working Oil Cooler Size - 2390X 410
MDBFP Lube Oil Cooler Size- 3050X 275
Vacuum Pump Seal Water Cooler Size - 3530X 275
AOH /REPAIR / REPLACEMENT OF VARIOUS VALVES IN TG HOUSE OF 600 MW UNIT NO.1&2
HIGH PRESSURE VALVES (PRESSURE ABOVE 50 KG / Sq.CM)
Size 300 mm and above
Size 200 mm and above but less than 300 mm
Size 100 mm and above but less than 200 mm
Size 50 mm and above but less than 100 mm
Size below 50 mm
MEDIUM PRESSURE VALVES (PRESSURE BETWEEN 10 TO 50 KG / Sq.CM)
Size 300 mm and above
Size 250 mm and above but less than 300 mm
Size 200 mm and above but less than 250 mm
Size 150 mm and above but less than 200 mm
Size 100 mm and above but less than 150 mm
Size 50 mm and above but less than 100 mm
Size 50 mm and less
NRV below 350 but above 100mm
LOW PRESSURE VALVES (PRESSURE BELOW 10 KG / Sq.CM)
Size 350 mm & above
Size 300 mm & above but less than 350 mm
Size 250 mm & above but less than 300 mm
Size 200 mm & above but less than 250 mm
Size 150 mm & above but less than 200 mm
Size 100 mm & above but less than 150 mm
Size 50 mm & above but less than 100 mm
Size 50 mm & below
NRV below 350 but above 100mm
OVERHAULING OF LOW PRESSURE BUTTERFLY VALVES
Butterfly valves 65 mm
Butterfly valves 100 mm
Butterfly valves 200 mm
Butterfly valves 300 mm
Butterfly valves 400 mm
Butterfly valves 500 mm
Butterfly valves 600 mm
Butterfly valves 700 mm
Butterfly valves 700 mm and above
OVERHAULING OF PUMPS IN UNIT N0. 1 &2
Replacement of M Seal-Main pump of BFP
Replacement of M Seal-BP of BFP
ACW PUMP
TG DMCW PUMP
SG DMCW PUMP
Overhauling of LP/HP Heaters
Overhauling of LP heaters
Overhauling of HP heaters
Overhauling of Crane
Servicing of monorail hoist crane(5MT-10MT)
SHASHI KUMAR AND COMPANY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .