Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹31.0 LAccepted-AOC 10TH FLOOR TOWER A3 FLAT NO 1001 MI RUSTLE COURT GOMTI NAGAR EXTENSION GOMTI NAGAR LUCKNOW UP 226010 | LUCKNOW | LUCKNOW | UP | 226010 | 1 | Accepted-AOC L-1 | |
| 2 | 2₹33.2 L+₹75,822 (2.34%)Rejected-Finance MD 1 236 SECTOR D1 LDA COLONY KANPUR ROAD LUCKNOW U P PIN 226012 | LUCKNOW | UTTAR PRADESH | 226012 | 2 | Rejected-Finance Being other than L-1 | |
| 3 | 3₹34.5 L+₹2.0 L (6.15%)Rejected-Finance | 3 | Rejected-Finance Being other than L-1 | |
| 4 | 4₹35.9 L+₹3.4 L (10.4%)Rejected-Finance 118 442 E 2 KAUSHALPURI KANPUR 208012 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208012 | 4 | Rejected-Finance Being other than L-1 | |
| 5 | 5₹38.8 L+₹6.3 L (19.5%)Rejected-Finance | 5 | Rejected-Finance Being other than L-1 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
30 Dec 2022, 6:00 pmClosed
GE EAST LUCKNOW
GE EAST LUCKNOW
REPAIR AND REPLACEMENT EXTERNAL ELECTRIC SUPPLY AND EXTERNAL WATER SUPPLY, BOREWELL, CLEANING OF OH TANK CONNECTED WORKS AT MILITARY STATION BARABANKI UNDER GE (EAST) LUCKNOW
2022_MES_564192_2
GE/E/LKO/T-36 of 2022-23
Open Tender
Civil Works
Item Rate
270 days
BARABANKI
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
GE EAST LUCKNOW
₹98,000
Yes
14 Jan 2023
12 Dec 2022
31 Dec 2022
12 Dec 2022
30 Dec 2022
18 Dec 2022
Amount
Excavation in trenches not exc 1.5 m wide and not exc 1.5m deep for laying of pipe, cable etc and getting out in soft/loose complete all as specified and directed.
Excavation in trenches beyond 1.5m depth for laying of poles etc and getting out in Hard/Dense soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and directed.
Removing surplus excavated material to a distance not exc 50 meter and depositing where directed at level not exc 1.5m above the starting point complete all as specified and directed.
M&L for sand cushioning for protection of cables complete all as specified and directed.
Supplying & laying common bricks sub class B for LT cable for protection of cable complete all as specified and directed.
Boring of road for laying of pipe not exc 90 cm below ground level all complete as specified and as directed.
S&F GI tubes light grade of size 40 mm galvanised with all fittings for road crossing including taking down / dismantling the old items complete all as specified and directed.
S&F in replacement mild steel cross arms channel, bracing, support, clamps etc fabricated structured steel, sections, including nuts, bolts, washers etc and cutting to required length bent to any shape drilling holes, fixed on poles or jointed by means of electrical welding including taking down / dismantling the old items complete all as specified and directed.
M&L for graded coarse aggregate of size 40 mm in the station yard for laying complete all as specified and directed.
S&F in repair danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with screws, nut bolts with adequate size clamps on HT/LT pole of 25x20 cm size complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in base foundation of pole concrete including providing necessary form work complete all as specified and directed.
M&L for PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation of pole/stay and filling of mass concrete including providing necessary form work complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 using 20 mm graded aggregate as in coping of pole including providing necessary form work complete all as specified and directed.
S&F in repair 10 sqmm 2 core aluminium unarmoured, flame resistant PVC flat cable, ISI marked complete all as specified and directed.
M&L for removing the vegetation growth for site clearance in soft /loose soil , around HT/LT poles and E/M installations complete all as specified and directed.
Taking down the old U/S steel LT/HT poles of any height ,struts including demolition of cement concrete,GI structure supports, stay assemblies, junction box complete all as specified and directed.
Supply, fixing ,erecting in replacement in proper position 9.0 mtr steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts, nuts and screws as specified type 410 SP-31 (9.0 metres long) Make:- Fabrico (India )Pvt. Ltd or equivalent as approved by GE . Note: (i) Excavation ,earth work and PCC shall be measured and paid separately.(ii) Painting will be measured and paid seperately under relevent item.
S&F in repair bracket for street light fitting made out of 40 mm dia light grade GI tubing bent to required shape 1.5 m long including necessary GI clamps, nuts bolts and washers and connecting with three core flexible wire of 1.5 sqmm copper conductor to the pole junction box including taking down / dismantling the old items complete all as specified and directed.
S&F in repair PVC/SMC weather proof, hinged door, junction box, size 300mm x 200mm x 100mm with 30A Aluminium bus bar 04 Nos, 240V, neutral link and 1 No. MCB SP of 06 Amps, alongwith necessary fixing arrangement such as clamps, nut, bolts, etc including taking down / dismantling the old items complete all as specified and directed.
Material and labour for Cleaning and preparation for painting surface of street light steel tubular pole 9 mtr long and painting with two coat of aluminum paint including brackets including applying two coats of cement base paint to coping,strip painting up to 1 mtr from coping with blue and white colour paint of strips ,writing Pole No. etc complete all as specified and directed.
Refixing including taking down the old serviceable street light along with fitting removed from above item complete all as specified and ditrected .
Refixing including taking down after repair including replacement of suitable LED driver 40 watts and make serviceable complete all as specified and ditrected .
Refixing including taking down after repair including replacement of suitable LED driver 90 watts and make serviceable complete all as specified and ditrected .
S&F in replacement PVC insulated sheathed round cable with stranded copper conductor of size 2.5 sqmm 3 core including taking down / dismantling the old items complete all as specified and directed.
S&F in replacement street light fitting Pressure die cast aluminium housing (LM6 Alloy), Minimum 9000-10000 Lumens with maximum system wattage 90 W-100 W, with PMMA lenses,External built proper heat shinks and toughtened glass/PC ensuring IP66 & IK>05 protection, LED used shall be SMD type and fixture should have minimum efficiency at system level (Not chip level) 100 Lumens/Watt. Life of system should be 50000 Hrs all including necessary wire for fitting light to pole complete all as specified and directed . Make:- Philips Cat Part No BRP410 LED 094 CW HE MR FG S2 PSU GR, CG Cat Part No LSTN-100-CDL-A or equivalent in Havells.
S&F in replacement of LED security light fitting 40 watt, 4000 lumen, 5700K with IP 66 protection comprises of a pressure die cast aluminium housing, heat resistance toughened glass, LED lenses, surge protector, electronic driver, etc and all accessories pre-wired including suitable mounting arrangement complete all as specified and directed.
S&F in replacement of sheet metal enclosure distribution board, vertical Tripple pole and neutral, AC, 415 volt, 04 way, bus bar and metal door with IP - 43 & IK 09 protection and flush to wall, as MCCB as incoming (Measured under relevent items of schedule ) , and MCBs as out going , including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed. Note:- 1. MCB as found after taking down shall be refixed . 2.MCCB shall be fixed under relevent items seperately .
S&F in replacement of sheet metal enclosure distribution board, vertical Tripple pole and neutral, AC, 415 volt, 06 way, bus bar and metal door with IP - 43 & IK 09 protection and flush to wall, as MCCB as in comming , and MCBs are out going , including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed and comprising of the following:- Note:- 1. MCB as found after taking down shall be refixed . 2.MCCB shall be fixed under relevent items seperately .
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 150 sqmm 3.5 core including taking down / dismantling the old items complete all as specified and directed.
S&F in replacement of MCCB, 3 pole, AC, 440 Volts 160 amps, 36 KA adjustable type complete all as specified and directed.
S&F in replacement of MCCB, 3 pole, AC, 440 Volts 630 amps, 50 KA adjustable type complete all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 70 sqmm 3.5 core, including taking down / dismantling the old items complete all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm 2 core, including taking down / dismantling the old items complete all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sqmm 4 core, including taking down / dismantling the old items complete all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 sqmm 3.5 core,including taking down / dismantling the old items complete all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 50 sq. mm 3.5 core,including taking down / dismantling the old items complete all as specified and directed.
S&F heat shrinkable jointing kit for 3 ½ / 4 core XLPE, armoured cable of size 25 to 50 sqmm including taking down / dismantling the old items complete all as specified and directed.
S&F heat shrinkable jointing kit for 3 ½ / 4 core XLPE, armoured cable of size 70 to 150 sqmm including taking down / dismantling the old items complete all as specified and directed.
S&F aluminium bus bar made out of aluminium alloy upto 500 Amps current rating /bolted type with nut ,bolts, washers in repair including taking down / dismantling the old items complete all as specified and directed.
S&F in repair Pin insulator 150 mm dia , 150 mm length suitable for 11 KV working pressure in pole of any description complete all as specified and directed.
S&F terminal junction box with including nut bolts with iron clamp out door dust and vermin proof fabricate with 1.6 mm thick MS sheet encloser 200X 250X150 mm including neutral link and 4 nos 230 volts 63 amps bus bar for house connection with 2X10 SQ mm copper conductor multi standard and connecting insulator including two coats of synthetic enamel paint over a coat of metal primer including taking down / dismantling the old items complete all as specified and directed.
M&L for development of tube well by V-notch method or any other approved method at the site with air compressor of capacity 250PSI/1000 cum and related accessories at least 60 hours till water discharge is free from sand and potable water and to achieve maximum discharege capacity of maximum LPH including carryout yield test with suitable pump for three consecutive days of uninterrupted 8 hours per day durations (for minimum discharge capacity of 2000 LPH) after necessary development complete all as specified and directed. Note: (i) Unit rate quoted under this items shall deemed to be inclusive of transportation of tools and equipments as required to the site of work and removing the same after completion of work. (ii) Vertically test of the tube well structure shall be carried out and the cost of the same shall be deemed to be included in unit quoted rate)
M&L for taking out of submersible pumpset capacity 25 HP from bore well/shallow well for repair and replacement of unserviceable column pipes approx 80 to 100 mtrs using chain pully block manually and transportation of submersible pump and motor assembly for necessary repair ement of wornout parts like bearing impeller bushing coupling etc and including refixing the existing serviceable components after proper cleaning , machining as required ,assembling testing at workshop , carrying out painting by complete all as specified & directed. Note:- All new parts / spares /re- winding/ component will be measured and paid seperately under respective items
M&L for complete overhauling of submersible pumpset of capacity 25 HP by replacement of bearings,stainer,applying quick drying warnish to starter winding,cleaning of mineral deposition and refixing part by part by using tools and tackless and necessary GI specials,bolts nuts,as required at site, carrying out painting with 2 coat of synthetic enamelled paint over a coat of primer, refixing the existing serviceable components after proper cleaning , machining as required ,assembling testing at workshop complete all as specified & directed. Note:- (i) All new parts spares /component will be measured and paid seperately under respective items (ii) Replacement of bolts /nuts washers is deemed to be included in the items.
S&F in replacement of brass impeller of 25 HP submersible pump complete all as specified and directed.
S&F in replacement of Stage casing bearing of 25 HP submersible pump complete all as specified and directed.
S&F in replacement of Shaft sleeve bush for 25 HP submersible pump complete all as specified and directed.
S&F in replacement of Suction Gun metal bush for 25 HP submersible pump complete all as specified and directed.
S&F in replacement of Thrust bearing complete for 25 HP submersible pump
S&F in replacement of Pump shaft key for each stage submersible pump complete all as specified and directed.
M&L for rewinding of 25 HP submersible pump set motor coil with water resistant super enameled quality copper winding wire as per existing gauge and providing insulation materials ,varnishing etc after cutting, removing burnt out / leakage damaged coils & reassembling the motor complete as reqd complete all as specified & directed.
S&F in repair seamless column pipe heavy duty of 80 mm bore with thickness not less than 6 mm , 8 TPI thread of 10 ft long each pipe with both end thread /flanged inbcluding joints complete all as specified & directed . Make :- TATA/Bansal/Jindal/Zenith
Supply and laying in replacement flat submersible cable PVC insulated weather / water proof with flexible copper conductor 1100 V grade 10 sqmm 3 core into the bore well along with the submersible pump set from the starter complete all as specified & directed .
M&L for transportation of submersible pump set 25 HP from Pump House to workshop and back to Pump House after repair lowering the pumpset along column pipe submersible cable using chain pully block manually and connectong with the existing rasing main all electrical connection, testing complete all as specified & directed
S&F in repair DOL starter conforming to IS 19947-4 suitable for Doser pump set 0.5 HP complete testing and commissioning including taking down / dismantling the old items complete all as specified and directed. Make : Siemens/L&T/ABB
Repairs & cleaning of valve chamber of size 500X500X500 mm by descaling accumulated water and removing all sludge, vegetables and carry out all masonry work like plastering, PCC flooring and applying two coats of white wash on inner and outer surfaces and applying two coats of synthetic enamel paint over a coat of metal primer on metallic opening door, sluice valve and pipeline including necessary welding work to repair door, hinges including taking down / dismantling the old items complete all as specified and directed.,
All as per item No. 57 above but valve chamber of size 750x750x750mm.
M&L in repair for construction of valve chamber of size 500X500X500 mm (internal dimension) with PCC 1:4:8 for foundation 150 mm thick , brick work built with CM 1:6 , PCC 1:3:6 coping 50 mm , plastering 15 mm thick in CM 1:6 to all internal and exposed surfaces including excavation ,earth work in hard / dense soil , MS sheet cover 4 mm thick and with MS angle iron 50 mm x 50 mm x 6 mm as per existing size with locking arrangement embedded in PCC suitable for 25/40/50 mm gate valves and painting the MS cover with two coats of synthetic enamel paint over one coat of red oxide / metal primer on metallic sheet, hinges etc including taking down / dismantling the old items complete all as specified and directed.
M&L for fabrication for repair & servicing of sluice valve of size 150 mm bore by replacement of stainless steel /Brass spindle /gun metal spindle ,checknut , Gland rope, side nobe lock nuts etc (Note Brass spindle shall be fabricated from solid round bar having did not less than dia of the largest section of the spindle by maching / lathe work), and refixing in the position,complete all as specified and directed.
M&L for fabrication for repair & servicing of sluice valve of size 100 mm bore by replacement of stainless steel /Brass spindle /gun metal spindle ,checknut , Gland rope, side nobe lock nuts etc (Note :- Brass spindle shall be fabricated from solid round bar having not less than dia of the largest section of the spindle by maching / lathe work), and refixing in the position,complete, all as specified and directed.
M&L for fabrication for repair & servicing of sluice valve of size 80mm bore by replacement of stainless steel /Brass spindle /gun metal spindle ,checknut , Gland rope, side nobe lock nuts etc (Note Brass spindle shall be fabricated from solid round bar having not less than dia of the largest section of the spindle by maching / lathe work), and refixing in the position,complete all as specified and directed.
S&F sluice valve, cast iron body, ISI marked and iron wheel head, flanged, class PN-1.6, IS: 14846-2000 including jointing material, rubber gasket, nuts, bolts, etc complete of 150mm bore including taking down / dismantling the old items complete all as specified and directed. Make:- Kirloskar/L&T/BIR
S&F sluice valve, cast iron body, ISI marked and iron wheel head, flanged, class PN-1.6, IS: 14846-2000 including jointing material, rubber gasket, nuts, bolts, etc complete of 100 mm bore including taking down / dismantling the old items complete all as specified and directed. Make : Kirloskar/L&T/BIR
S&F sluice valve, cast iron body, ISI marked and iron wheel head, flanged, class PN-1.6, IS: 14846-2000 including jointing material, rubber gasket, nuts, bolts, etc complete of 80 mm bore including taking down / dismantling the old items complete all as specified and directed. Make : Kirloskar/L&T/BIR
S&F in repair Non return valve of CI flanged end, class-I, ISI marked with rubber packing, nuts & bolts etc complete of 100 mm bore including taking down / dismantling the old items complete all as specified and directed. Make: Kirloskar/L&T/BIR .
M&L for supply , install ,test and commissoning of Calcium Hypochloride Dosing system complete with Granular chlorination dosing pump (model 96 NGQ 51) high pressure single head gear motored adjustable dosing pump having output of 2 us GPD to 40 US GPD and adjustable high pressure of upto 100 PSI (07 KG /CM2) with accessories including lead tubing connections nuts, injection check valve, clay weights and ferruls and 100 ltrs FRP tank with lid & Level guage along with Agitator and shaft blade in plastic mounted on tank .The agitator motor must possess following specification Applicable both online and offline like necessary arrangements at site will provide by the contractor voltage input 230 V single phase 50 HZ 900 Rpm of suitable capacity Model ADS 1 complete all as specified and directed. Make:- Declibac Technologies or equivalent as approved by GE.
M&L for service and repair of Chlorine Dosing Pump alongwith connected items complete all as specified and directed. Note: All itmes required for Service will be measured and paid separately.
S&F in repair complete head assembley for chlorine dosing pump alongwith PVC adaptor of 1/2" Bore, PVC NRV with glass Ball for both suction and outlet of head complete all as specified and directed.
S&F in repair solid PVC NRV of 1/2" Bore connection for outlet of Chlorine Dosing Pump complete all as specified and directed.
S&F in repair PVC adaptor of 3/4" Bore for connecting outlet/inlet of Chlorine Dosing Pump complete all as specified and directed.
Supply only high stength Calcium based granular containing appropriate quantities of chlorinations dipensiates/corrosion inhibitors to prevent encrustation /Scaling in distribution system in 45/50 Kgs packing of approved and tested from Govt lab or equivalent testing authority (not more than two months of packing) complete all as specified and directed. Make: Adaani wilmar model PURICHLOR / Aquafit or equivalent as approved by GE.
Supply only Sodium Hypochlorite solution grade 1 containing apprppirate quantities of chlorinations dipensiates/corrosion inhibitors to prevent encrustation /Scaling in distribution system of approved and tested from Govt lab or equivalent testing authority (not more than two months of packing ) (chlorine concentration 10% or more) for treatment of drinking water complete all as specified and directed.
Draining out water from over head reservoir of 50000 Gln capacity , removing sludge deposited, scales and other impurities from inside the tank thoroughly by scrapping with wire brushes, broom stick to make the surfaces free from sludge deposit and impurities, cleaning & washing the surfaces with bleaching powder solution including rewashing with fresh water and writing letters /figures like “Tank cleaned on________(date) and Due date_____ boldly & prominently with thick synthetic enamel with height & width of letters/figures 15cm & 10cm respectively in prominent places of tank ,white washing inside and out side distemper colour complete OH Tank as directed and also painting the all incomming , outgoing, overflow CI/DI water main including scarping out the old painting and applying two coats of synthetic enamel paint over a coat of red oxide with proper colour coating and marking complete all as specified and as directed. Note :- Scaffolding work included in the rate quoted.
M&L for writing letters or figures not exc 30 cm height in block Roman, Italian or indian letters including stops, comma, arrows, brackets, dashes etc on walls, sign boards (black or yellow or as required base) including two coats of oil paint over a coat of white base synthetic enamel paint complete all as specified and directed.
Test and submit the test report of samples of portable water for Chemical/Biological test report for the samples of portable water and submit the Chemical/Biological test report from the reputated state / Central government water test lab and producing test reports to Engineer In charge when ever directed complete all as specified and directed.
M&L for fixing of CI/DI fittings / specials like Bend (any radius and angle) , Taper any type ( straight , bends,increasing,decreasing,or double socket etc), Tee pieces single branch 'Y' junction, double branch cross (all socket or socket and spigot), collar caps and plugs etc upto 150 mm dia complete all as specified and directed.
M&L for Flange joints by digging out up to depth of existing pipe line and complete the joint by using D-joint including necessary flange of 20 mm thick, 6 mm thick rubber insertion, nuts, bolts, washers including bailing out the accumulated water in the trenches, complete all as specified and directed . (a) For 100mm bore
(b) All as per item No. 78 above but for 80mm bore
Taking out/down of old U/S GI pipeline for the following size from excaveted trenches including removal of fitting all as directed for necessary replacement / relaying of serviceable GI pipeline complete all as specified and directed . (a) For 100mm bore pipe.
(b) All as per item No. 80 above but 80mm bore pipe.
(c) All as per item No. 80 above but 50mm bore pipe.
(d) All as per item No. 80 above but 40mm bore pipe.
(e) All as per item No. 80 above but 25mm bore pipe.
(f) All as per item No. 80 above but 20mm bore pipe.
(g) All as per item No. 80 above but 15mm bore pipe.
Relaying of GI pipe after removal of scaling , cleaning and flushing etc including supply and fixing of new fittings of following sizes of any grade in trenches and testing complete all as specified and directed. (a) For 100mm bore pipe.
(b) All as per item No. 87 above but 80mm bore pipe.
(c) All as per item No. 87 above but 50mm bore pipe.
(d) All as per item No. 87 above but 40mm bore pipe.
(e) All as per item No. 87 above but 25mm bore pipe.
(f) All as per item No. 87 above but 20mm bore pipe.
(g) All as per item No. 87 above but 15mm bore pipe.
Relaying only of GI pipe after removal of scaling , cleaning and flushing etc including supply and fixing of new fittings of following sizes of any grade in floor,walls or in ceiling and testing complete all as specified and directed. (a) For 25 mm bore pipe.
(b) All as per item No. 94 above but 20 mm bore pipe.
(c) All as per item No. 94 above but 15 mm bore pipe.
Supply & laying only of GI pipe medium grade, with all fittings, laid in trenches or on walls, complete, all as specified and directed . Make: Jindal/Tata/Prakash /Surya (a) For 100mm bore pipe.
(b) All as per item No. 97 above but 80mm bore pipe.
(c) All as per item No. 97 above but 50mm bore pipe.
(d) All as per item No. 97 above but 40mm bore pipe.
(e) All as per item No. 97 above but 25mm bore pipe.
(f) All as per item No. 97 above but 20mm bore pipe.
(g) All as per item No. 97 above but 15mm bore pipe.
Taking out U/S gate valves from pipe line for necessary replacement , excavation ,necessary earth work etc of following sizes of any grade in trenches /walls/ceiling etc including testing complete all as specified and directed of the following sizes :- (a) For 50 mm dia
(b) All as per item No. 104 above but 40 mm dia
(c) All as per item No. 104 above but 25 mm dia
(d) All as per item No. 104 above but 20 mm dia
(e) All as per item No. 104 above but 15 mm dia
S&F Gun metal gate valve with iron wheel head, screwed both ends for iron pipe of the following sizes :- (a) For 50 mm dia
(b) All as per item No. 109 above but 40 mm dia
(c) All as per item No. 109 above but 25 mm dia
(d) All as per item No. 109 above but 20 mm dia
(e) All as per item No. 109 above but 15 mm dia
Repair/Maintenance of water leakages for GI pipeline joints in ground/trenches and identifying the defect and open carefully the joint portion of the pipeline duly excavated the trench and removing the defective joints in the existing pipelines and provide with a new pipe joints etc as per the site requirement to make the joint 100% leakproof including excavation and testing complete all as specified and directed for the following size:- (a) For 100 mm bore pipeline
(b) All as per item No. 114 above but 80 mm bore pipeline
(c ) All as per item No. 114 above but 50 mm bore pipeline
(d) All as per item No. 114 above but 40 mm bore pipeline
(e) All as per item No. 114 above but 25 mm bore pipeline
(f) All as per item No. 114 above but 20 mm bore pipeline
(g) All as per item No. 114 above but 15 mm bore pipeline
M&L in replacement earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to the GI strip 32 x 6mm, by means nut bolt, nuts, check nuts and washer of the GI Earth wire protected by provision of GI light grade pipe 40 mm including provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregated with 40 mm thick cover with RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, taste point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point including testing on completion”complete all as specified and directed .
S&F in replacement of earth continuity conductor with adequate size saddles fixed to wall on batten or recess or any other indicated situation for loop earthing etc. as required 32mm x 6mm GI strip including taking down / dismantling the old items complete all as specified and directed.
M&L Stay assembly comprising of 20 mm dia stay rod 2150 mm long, loop type insulator of size 90 mm x 140 mm, galvanised stay plate 6mm thick of size 300 mm x 300 mm, stay bow, stay clamps etc. & shown in EP No. 1 of SSR Part I ,including taking down / dismantling the old items complete all as specified and directed. Note:- Excavation, earth work and PCC shall be measured and paid separately.
Supply,fixing and erecting Hot Dip galvanised octagonal pole in proper position 9.0 Mtr height top A/F 70mm bottom A/F 155mm,single section-3mm shaft thickness, baseplate 260x260x16mm Pcd 260mm including foundtation with foundtaion bolds L- type M25x750mm {threaded part in galvanized finished and remaining part in Red Oxide} and single Arm Bracket 1mtr long straight type [Arm Pipe Size -40NB Medium Class as per IS: 1161] complete all as specified and directed Make:Bajaj /Utkarsh or equivalent as approved by GE . Note: (i) Excavation ,earth work and PCC shall be measured included in unit rate quoted by the contractor.
S & F incuding foundation,Testing Automatic Power Factor Correction(APFC) Panel for 3 Phase, 415 V & 50 Hz system of capacity 150 KVAR without incoming MCCBs as per approved drawing from Engr in charge. Indoor type, double door, cubical type, pedestal mounted, factory made, fabricated out of 2.15 mm thick CRCA sheet suitable. The APFC panel consists microprocessor based control relay with capacitors 150 KVAR (50 KVAR X 1) (25 KVAR X 2) (10 KVAR X 3 Nos) and (5 KVA X 4 Nos) connected with contractors, tripping coils, digital multifunctional measuring meter with LCD display and 250A, 25 KA, 4P MCCB for incoming of APFC panel complete all as specified and directed.
R K CONTRACTOR AND SUPPLIERS
Shree Kanth Technologies
Supreme Builders
MTR GROUP & COMPANY
NAVJYOTI ENTERPRISES
LOKESH CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .