Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹11.7 LAccepted-AOC HOUSE NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR PB 144022 | JALANDHAR | JALANDHAR | PUNJAB | 144022 | ₹11.7 L Quoted ₹11.8 L | 1 | Accepted-AOC Lowest |
| 2 | 2₹12.4 L+₹65,529.15 (5.57%)Rejected-Finance | ₹12.4 L+₹65,529.15 (5.57%) | 2 | Rejected-Finance Higher |
| 3 | 3₹13.8 L+₹2.0 L (17.1%)Rejected-Finance 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹13.8 L+₹2.0 L (17.1%) | 3 | Rejected-Finance Higher |
| 4 | 4₹15.6 L+₹3.9 L (32.8%)Rejected-Finance 99 MODEL TOWN PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹15.6 L+₹3.9 L (32.8%) | 4 | Rejected-Finance Higher |
Tender Value
₹11.7 L
EMD Value
₹23,400
Closing Date
24 Feb 2021, 4:00 pmClosed
GE Amritsar
GE Amritsar PIN-143001
Provn of certain sanctioned E/M works at Amritsar Cantt
2020_MES_408056_1
GE/ASR-47/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE Amritsar
Class E, category bi
8 documents required · 8 mandatory
₹500
GE Amritsar
₹23,400
Yes
27 May 2021
30 Dec 2020
25 Feb 2021
30 Dec 2020
24 Feb 2021
11 Feb 2021
Amount
Taking down old unserviceable point wiring any type from existing conduit (light, fan, socket or power point etc) complete such as switches, ceiling rose, pendent, regulator and socket etc and removing the material FR on site and making good the disturbed surface of wall / floor/ ceiling etc as original by brick work, plastering, whitewash/colour/distemper etc complete all as complete all as specified and directed.
M & L point wiring complete with 1.5 Sq mm (nominal area) FR PVC insulated un-sheathed and stranded copper conductor cable ISI marked and including PVC concealed conduit ISI marked of size 25 mm dia and 1.5 mm wall thickness and conduit fittings including FR PVC insulated unsheathed 1.5 Sqmm copper earth wire to common earth and connecting to earth dolly and Metal Flush box, cover plate with frame of suitable size for fixing modular switches/sockets/fan regulator etc complete all as specified for the following (Note : Cost of Metal boxes and modular accessories like cover plates will be included in quoated rate.) Make:- Havells, Finolex / RR Kabel (a) One light point/Bell/Fan point controlled by one switch.
All as per item No 2 above but one 3 pin 5 amps switch socket on independent board.
All as per item No 2 above but one 3 pin 5 amps switch socket on same board.
All as per above item herein before but with cable 2.5 sqmm (nominal area) multistranded copper wire unsheathed for one 3 pin socket outlet 15 amps on independent board including continous earth wirte PVC insulated 2.5 sqmm copper multistranded conductor connecting to common earth and earth dolly complete all as specified and directed Note for items Nos 1 to 5 :- (a) The wiring shall be done in proper colour coding using red,yellow and blue for phase,black for neutral and green for earth leads.
Supply and fix switch piano one way 5 A, SP, 230 Volts.Make : Anchor/SSK/Cona
Supply and fix Socket outlet 2 in 1, 3 pin 5 Amps Flush type. Make : Anchor/SSK/Cona
Supply and fix Switch outlet 2 in 1, 3 pin15 Amps Flush type. Make : Anchor/SSK/Cona
S & F Ceiling rose, surface bakelite 3 terminal, 240 volts, 5 Amps with back plate of 3 mm thick bakelite, laminated hylem sheet of appropriate size & MS box of suitable size and making good surface as original by plastering and whitewash/colour/distemper etc complete all as specified. Make : Anchor/SSK/Cona
S & F wall /ceiling mounting LED 18 tube light fitting complete with all acessories 1x18 Watt LED , suitable for domestic application, 240 Volts, 50 Hz, including one tube rod and internally pre-wired with 1.5 sqmm twin twisted flexible cable copper conductor and connection complete Make Havell's / Wipro Phillps complete all as specified and directed.
S&F Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting SPN 12 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as specified. Make :INDO ASIAN/ Havells/Schneider Elect . (Note : cost of removing old wooden box and making good of surface as original by brick work, plastering, whitewash/colour/distemper etc is included in quated rate) Make : Legrand Lexic / Schneider , HAGER
S&F street light distribution outdoor panel with canopy single door vertical type made out of CRCA MS sheet with thickness not less than 3 mm surface with insulated material like polysofer or with epoxy powder coating surface mounting TPN 4 way,415 Volt with copper bus bar rating 200Amps for R,Y,B,N phases dust and vermin proof suitable for incorporation of MCCB and IP43-IK09 profection with and incl 100Amps 16KA 4 Pole MCCB including angle iron support legs and foundation work for the legs (including excavation and doing PCC 1:2:4). Make of MCCB Legrand/Schnedier/Siemens. The size of the panel should not be less than 600mmx400mmx200mm, and height of the panel should be atleast 300mm above ground level. the angle iron for support should be minimum 35 mm x 35mm x 5 mm thick.
S&F MCCB Incomer distribution board double door vertical type made out of CRCA MS sheet surface with insulated material like polyester or with epoxy powder coating surface mounting TPN 4 way, 415 volts with copper bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCCB and IP 43 - IK 09 protection with and incl 100 amp 36 kA 4 pole MCCB with thermal - magnetic setting and Icu = Ics = 100% (Make of MCCB : Legrand Lexic DPX /Schinder Elect complete all as specified. Make : Legrand Lexic / Schneider , Siemens . (Note : The cost of removing old wooden box and making good of surface as original by brick work, plastering, whitewash/colour/distemper etc is included in quated rate)
S & F MCB double pole, 240 volts, 40 to 63 Ampere, rupturing capacity 10 KA, ‘C’ curve type complete all as specified and directed. Make : Legrand Lexic / Schneider / Siemens
Supply and fix stepped type electronic fan regulator flush type all as specified and directed. Make : Anchor/SSK/Cona
S & F lamp holder insulated body angular type with back plate of 3 mm thick bakelite, laminated hylem sheet of appropriate size & MS box of suitable size and making good surface as original by plastering and whitewash/colour/distemper etc complete all as specified and directed. Make :- Anchor / Reo / Cona
Supply and fixing of 2X2 LED Slim Panel Light 36/40 Watt Recessed mounted suitable for false ceiling mounting complete all as specified and directed by Engr-incharge. Make Philips/CG/Wipro
S & F BEE star rated Ceiling fan 1400 mm sweep complete with downrode including fitting and fixtures as per site requirement and complete accessories suitable for 230 Volts single phase 50 Hz AC supply and connecting up with and including two core PVC insulated, PVC sheathed copper conductor all as specified and directed. Make: Havells/CG/Orient
M & L for sub main wiring with PVC insulated, 1100 volts grade single core multistranded copper conductor cable conforming to IS specifications, 3 runs of 6 sqmm single core multistranded copper conductor PVC insulated cables as neutral continuity conductor drawn through and including one run of 25 mm dia rigid PVC conduit and conduit accessories fixed on wall/ceiling etc., or concealed in wall and connecting to common earth dolly all as specified and directed including taking down all sub main wiring . Note : 3 Run of 6 sqmm and 1 run of PVC conduit as mesuared as 1 unit Make of wire RR Kabel/Poly cab/Havells
Supply and fixing of socket outlet two-in-one, 3 pin each suitable for 5 and 15 Amperes flush type, 250 volts AC complete all as specified and directed. Make Legrand/Anchor/Crebitree (Schneider)
S&F of street light fitting brackets 1.5 meter long made out of galvanized iron pipe of 32/40 mm dia size suitable for LED fittings light grade complete with nut bolts washers etc inclusive of one primer coat one under coat and one finishing coat of silver paint complete all as specified and directed by Engr-in-Charge.
Supply and fix steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-22 (8.5 meter long) complete all as specified and directed by Engineer in Charge.Including Cleaning surface of steel pole upto 8.5 Mtr long excluding planting depth complete and painting with one coat of aluminium paint including channels street light brackets cross arms anti climbing devices and making black & white strips with synthetic enamelled paint 30 Cm height, each alternative strip upto 1.5 mtr height writing pole numbers as per existing practice, making round base of dia 120mm by using yellow colour and marking the pole numbers of letter size equal to 70mm in height by using black colour with stencil complete all as specified and directed by Engr-in-Charge
Supply, laying and testing cable XLPE Insulated ,armoured screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16sq mm 4 core Make : Havells / Polycab / Finolex
M & L for laying of LT cable of 1100 volt XLPE insulated and PVC sheathed of size 25 sqmm 4 core with cable gland including taking down old unserviceble cable complete all as specified and directed by Engineer-in-Charge. Make : Havells / Polycab / Finolex
Supply and fix in replacement of 90W LED light fitting made of pressure die cast aluminium alloy for housing heat sink for effective thermal management studyness excellent corrosion resistance cable gland is used for maintaining ingressprotection epoxy powder coated grey colour finish after phosphochromate treatment, tempered protective toughened glass, thermal shock and impact resistance fixed to the housing with SS screws. High efficacy long life LED module with the SMD LED package mounted on MCPCB with lumen efficacy of LED >140 lumen/Watt with PC lens to ensure better uniformity of light distribution, ambient temperature 35 degree celcius .and system lumen 9000 for above. Power by built in isolated electronic driver SMPS base constant current supply with lower THD, output open slash short circuit protection , Over voltage protection , Phase to phase protection , surge voltage protection 10 KVA. with IK 07 and IP 66 protection, CCT 5700K CRI more than 70 THD<10%, SPD 10 KVA for internal and external 10 KVA extra should be fixed with fitting, PF> 0.95 IP66 IK07 protection with life of 50000Hrs @ L70 operating temp -10 degree to +50 degree input supply voltage range 140/270V frequency 50/60Hz . Driver safety requirement standard: IS 15885/2/13, driver performance requirement IS 16104. Photobiological safety norms IS 16108. Certification LM 79 for luminar LM 80 for LED. And warranty should be 5 Years on site. Make : Havells/philips/wipro.
S&F of Junction Box shall be insulated and made out of Polycarbonate with glass fiber reinforced. The size should be not less then 200 X 160 X 98 in mm cat. Part no KF5255. The Polycarbonate JB shall be environment friendly, recyclable, UV resistant, halogen & silicon free, anti acid & anti corrosive. The JB shall be rated for Degree of Ingress Protection IP 66 in accordance with IEC 60529. The gasket material shall be Polyurethane and the gasket shall be internally embedded. The JBs shall be complies with requirements of the standards IEC 60998-1, IEC 60998-2-1, IEC 60670 –22 & IEC 60670 – 2-5. The JB color according to RAL 9011. The manufacturer of Junction Box / Enclosure shall submit a copy of IEC Certificate. For better safety the Polycarbonate encl shall be fire retardant & self-extinguishing in accordance with IEC 60 695-2-11, DIN VDE 0304 Part 3, UL Subject 94 for Flammability V-2. It should be tested at Glow Wir test for 960 deg. Cent. The impact strength of polycarbonate enclosures / boards i.e. the Degree of Protection against Mechanical load shall be in accordance with EN 50298-98 for IK 08. including one single pole MCB 6A ,make of MCB legrand/schneider/siemens Made of Hensel/Rittal or equivalent. Manufacturer should submit routine test certificate for CJB/PJB.
M&L PVC insulated PVC Sheathed multi stranded copper conductor wire 2.5 sqmm size twin core complete for drawing through pole for making connection to street light fitting provided on poles upto junction box incl thimbles. Make : Havells/Finolex/Polycab.
Supply and laying old size as sub class 'B' bricks, laid flat in trenches over the cable along the length of cable and bricks perpendicular to the direction of cable adjacent / abutting each other compete all as specified . and directed by Engr-in-Charge.
M&L for sand cushioning with layer of sand 8 cm thick before laying of cable and 15 cm after lying of calbe in trenches complete all as specified & directed.
M&L for earthing complete with galvanised steel earth plate electrode 600mmx600mmx6.3 mm thick burried in ground vertically to a depth not less than 2.25 meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below the ground level, earth plate surrounded 15 cm thick layers of common salt and charcoal dust starting FR on ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron earth lead of size 4 mm by means of galvnised nuts, bolts and washers. GI wire of 4 mm dia laid in 15 mm dia light grade GI pipe as protection FR on top of the plate up to test point (cost of protection pipe up to 7.5 meters FR on earth electrode will be included in the rates quoted by the contractor) with following:- (a) test point of GI.(b) Watering pipe GI light grade 20mm dia FR on top of the earth electrode up to MS funnel with brass wire mesh embeded in floor of PCC earth pit. (GI watering pipe should properly tightned on GI plate & Funnel and embeded in PCC floor of earth pit) (c) PCC earth pit 30cmx30cmx30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 25mm thick with 1 Nos MS handles suitable for carrying of pit cover.(d) Angle Iron FR Made of 40x40x4 mm size angle iron for holding earth pit cover.Note :- The cost of excavation, earth work, watering pipe, metal test point, MS funnel with brass wire mesh and RCC pit with pit cover have already been included in the rates. No extra cost shall be paid to the contractor against these items.
Supply and fixing 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed in service connection for size 2 core 6 Sqmm, all as specified and directed by Engr-in-charge.
S&F MCB C Curve type suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA as specified and 6 to 32 Amps. Make : Legrand Lexic / Schneider , Siemens
Blanking plate of plastic (suitable for distribution board).
S & F 40 mm bore light grade galvanised iron tubing with all necessary GI fittings as in protection pipe of cable, fixed to pole or laid under floor / ground / under road crossings for protection of cable complete all as specified and directed.
Supply and fix in replacement of 60W LED light fitting made of pressure die cast aluminium alloy for housing heat sink for effective thermal management studyness excellent corrosion resistance cable gland is used for maintaining ingressprotection epoxy powder coated grey colour finish after phosphochromate treatment, tempered protective toughened glass, thermal shock and impact resistance fixed to the housing with SS screws. High efficacy long life LED module with the SMD LED package mounted on MCPCB with lumen efficacy of LED >140 lumen/Watt with PC lens to ensure better uniformity of light distribution, ambient temperature 35 degree celcius .and system lumen 9000 for above. Power by built in isolated electronic driver SMPS base constant current supply with lower THD, output open slash short circuit protection , Over voltage protection , Phase to phase protection , surge voltage protection 10 KVA. with IK 07 and IP 66 protection, CCT 5700K CRI more than 70 THD<10%, SPD 10 KVA for internal and external 10 KVA extra should be fixed with fitting, PF> 0.95 IP66 IK07 protection with life of 50000Hrs @ L70 operating temp -10 degree to +50 degree input supply voltage range 140/270V frequency 50/60Hz . Driver safety requirement standard: IS 15885/2/13, driver performance requirement IS 16104. Photobiological safety norms IS 16108. Certification LM 79 for luminar LM 80 for LED. And warranty should be 5 Years on site. Make : Havells/philips/wipro.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep in any type of soil complete all as specified and as directed.
Returning, filling in, excavated earth including spreading levelling , watering including well ramming in layers not exc 25cm thick complete all as specified and directed.
Removal of surplus soil to a distance n.exc 50 mtr & depositing where directed at a level n. exc. 1.5mtr above the starting point complete all as specified & directed.
M & L for 75 mm thick PCC Type D-2, 1:4:8, (using 40 mm graged aggregate) as in sub bloors, sub bases of floors and pavings etc
M & L PCC 1:3:6 type C-2, using stone aggregate 40mm graded as in foundation for electric poles including necessary form work where required and fair finish to the exposed surfaces all as specified & directed by Engr-in-Charge.
M & L PCC 1:2:4 type B-2, using stone aggregate 40mm graded as in foundation for post including necessary form work where required and fair finish to the exposed surfaces all as specified & directed by Engr-in-charge
Supply ,installation, testing and commissioning on line UPS 20 KVA online UPS (3phase-1phase) with galvanic isolation transformer and following Salient Features :- (a) Wide input voltage and frequency window (b) Built in galvanic isolation transformer (c) Auto self Test on LCD Panel (d) Fuzzy logic controlled battery charging (d) Intelligent Battery Management (e) Scalable Runtime (f) Cold start (G) Backup 25-30 mintues (h) Pure Sine Wave output (i) Sealed Maintainence free Power Batteries of size and number suitable for providing required backup as per manufacturer specification including accessories for batteries such as inter cell connector ,inverter to battery cables and customized battery MS Rack/Trolley Note: (1) Cost of providing trolley/Rack for UPS and battery is included in the quoted rate of this item Make Sukam/Microtek/Luminous
S&F Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting SPN 8 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators incuding blanking and dummy plates complete all as specified. Make :Legrand / Siemens /Schneider Elect .
Material and labour for sub main wiring consisting Four single core PVC insulated and unsheathed FR cable with stranded copper conductor, size 10 Sqmm, earth wire 10 Sqmm two run of multi stranded copper conductor, drawn into and including concealed non metalic PVC conduit, 2 mm thick, 25 mm dia (external) inclusive of MS junction / terminal boxes and all fittings and accessories including cutting / chasing in brick / stone masonary and making good the surfaces to match with existing taking down old unservicable sub main wiring complete all as specified. Note:- Four single core of cable 10 Sqmm and two run of 10 Sqmm earth wire including PVC conduit shall be measured as 'One Unit'.
M/S SIMRAN WALIA ENTERPRISES
kailu construction co
satpal and brothers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .