Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹24,000
Closing Date
27 Mar 2024, 4:00 pmClosed
Executive Engineer ED-II JPDCL
Executive Engineer ED-II JPDCL
Rate contract for creation of 25 KVA, 63 KVA and 100KVA Distribution Substations at different locations within the jurisdiction of Electric Division-II Jammu on turnkey basis during the Financial Year 2024-25
2024_PDD_246371_1
Enit 10 of 2024-25 Dated 04-03-2024
Open Tender
Electrical Works
Turn-key
60 days
ED-II JPDCL
As per ENIT and SBD
8 documents required · 8 mandatory
₹1,000
Executive Engineer ED-II JPDCL
₹24,000
13 Jun 2024
6 Mar 2024
28 Mar 2024
6 Mar 2024
27 Mar 2024
6 Mar 2024
Amount
Creation of 11/0.433kV, 25 KVA, 3-phase Distribution Substation
Supply, Installation & commissioning of 11/0.433kV, 25 KVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound) with LV Cable Box having detachable Aluminium Gland plate. ( As per Latest Ammendment upto date)
Supply, Transportation, Erection of 9 Mtr Long ST Pole (ST-410 SP33) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. Including painting with two coats of Red Oxide and Al. Paint for smooth surface.
Supply, Transportation, Fabrication & Fixing of G.I Channel Iron, Cross arms, Angle Iron Braces, Clamps etc. duly fabricated including all necessary G.I Nut & Bolts & Washers etc.
Supply, Installation, Testing & Commissioning of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
Supply, Installation, Testing & Commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A
Supply & Fixing of Gapless Surge Arrestor,9 kV ,10 kA, LA with polymer housing, Stn. Type
Providing & fixing of 50 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type along with 12 Nos Al. Thimble of size
Providing & Fixing of LT Distribution Box for 25 kVA DTR with 50 Amp MCCB for incomer & SFU’s for Outgoing Circuits including Busbar arrangements for Phases & Neutral of EC Grade Aluminium, PVC Insulated Sleeved Busbar of required load handling capacity with colour code for Phases and Neutral differentiation, including Aluminium thimbles of required sizes for proper termination etc.
Providing of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 Mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body, G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts, refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Providing of Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole
Providing & fixing of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing & fixing of 11kV Polymeric composite Disc Insulator 12kV with Fitting, min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Wedge Connectors / PG Clamps
Providing & Fixing of Anti Climbing device with Clamps
Providing & Fixing of Danger Plates with Clamps
Providing & Fixing of Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid Stay Rod & 7/3.15 mm dia stranded wire complete
Description of Work / Item(s)
Amount
Creation of 11/0.433kV, 63 KVA, 3-phase Distribution Substation
Supply, Installation & commissioning of 11/0.433kV, 63 KVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound) with LV Cable Box having detachable Aluminium Gland plate. ( As per Latest Ammendment upto date)
Supply, Transportation, Erection of 9 Mtr Long ST Pole (ST-410 SP33) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. Including painting with two coats of Red Oxide and Al. Paint for smooth surface.
Supply, Transportation, Fabrication & Fixing of G.I Channel Iron, Cross arms, Angle Iron Braces, Clamps etc. duly fabricated including all necessary G.I Nut & Bolts & Washers etc.
Supply, Installation, Testing & Commissioning of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
Supply, Installation, Testing & Commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A
Supply & Fixing of Gapless Surge Arrestor,9 kV ,10 kA, LA with polymer housing, Stn. Type
Providing & fixing of PVC Cable 120 mm² along with 12 Nos Al. Thimble of 120 mm²
Providing & Fixing of LT Distribution Box for 63 kVA DTR with 100A MCCB for incomer & SFU’s for Outgoing Circuits including Busbar arrangements for Phases & Neutral of EC Grade Aluminium, PVC Insulated Sleeved Busbar of required load handling capacity with colour code for Phases and Neutral differentiation, including Aluminium thimbles of required sizes for proper termination etc.
Providing of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 Mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body, G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts, refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Providing of Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole
Providing & fixing of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing & fixing of 11kV Polymeric composite Disc Insulator 12kV with Fitting, min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Wedge Connectors / PG Clamps
Providing & Fixing of Anti Climbing device with Clamps
Providing & Fixing of Danger Plates with Clamps
Providing & Fixing of Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid Stay Rod & 7/3.15 mm dia stranded wire complete
Description of Work / Item(s)
Amount
Creation of 11/0.433kV, 100KVA, 3-phase Distribution Substation
Supply, Installation & commissioning of 11/0.433kV, 100KVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound) with LV Cable Box having detachable Aluminium Gland plate. ( As per Latest Ammendment upto date)
Supply, Transportation, Erection of 9 Mtr Long ST Pole (ST-410 SP33) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. Including painting with two coats of Red Oxide and Al. Paint for smooth surface.
Supply, Transportation, Fabrication & Fixing of G.I Channel Iron, Cross arms, Angle Iron Braces, Clamps etc. duly fabricated including all necessary G.I Nut & Bolts & Washers etc.
Supply, Installation, Testing & Commissioning of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
Supply, Installation, Testing & Commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A
Supply & Fixing of Gapless Surge Arrestor,9 kV ,10 kA, LA with polymer housing, Stn. Type
Providing & fixing of PVC Cable 185 mm² along with 12 Nos Al. Thimble of 185 mm²
Providing & Fixing of LT Distribution Box for 100kVA DTR with 160A MCCB for incomer & SFU’s for Outgoing Circuits including Busbar arrangements for Phases & Neutral of EC Grade Aluminium, PVC Insulated Sleeved Busbar of required load handling capacity with colour code for Phases and Neutral differentiation, including Aluminium thimbles of required sizes for proper termination etc.
Providing of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 Mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body, G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts, refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Providing of Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole
Providing & fixing of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing & fixing of 11kV Polymeric composite Disc Insulator 12kV with Fitting, min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Wedge Connectors / PG Clamps
Providing & Fixing of Anti Climbing device with Clamps
Providing & Fixing of Danger Plates with Clamps
Providing & Fixing of Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid Stay Rod & 7/3.15 mm dia stranded wire complete
M/S PVM INFRA
KAPIL GUPTA
M/s ASL POWER SOLUTIONS
M/S DAYAL BUILD TECH
M/S RATHER CONSTRUCTIONS AND TRADERS
JASMEET SINGH
M/S PVM INFRA
Rissam Traders and General Suppliers
JASMEET SINGH
KAPIL GUPTA
M/S RATHER CONSTRUCTIONS AND TRADERS
M/S DAYAL BUILD TECH
M/s ASL POWER SOLUTIONS
JASMEET SINGH
Rissam Traders and General Suppliers
KAPIL GUPTA
M/S RATHER CONSTRUCTIONS AND TRADERS
M/S DAYAL BUILD TECH
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .