| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical 1 8 373 FLAT NO 704 KRISHE GARDEN BEGUMPET BEGUMPET HYDERABAD TELANGANA 500016 | MEDCHAL MALKAJGIRI | TELANGANA | 500016 | Rejected-Technical Rejected by CFA |
| 4 | Rejected-Technical | Rejected-Technical Rejected by CFA |
Tender Value
₹10.2 L
EMD Value
₹20,400
Closing Date
28 Jul 2022, 11:30 amClosed
So-1(Wks)
SO-1(Wks)HQ 7 Sector Assam Rifles
Maintenance and Operation Of one 100 KWP Solar Power Plants Installed at Tuensang of HQ 7 Sector AR
2022_ARMHA_699483_1
7Sect/Engr/2022-23/1
Open Tender
Miscellaneous Works
Works
330 days
Tuensang
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Yes
In favour of SO-1(Wks) HQ 7 Sectors Assam Rifles
₹20,400
Yes
8 Dec 2022
8 Jul 2022
29 Jul 2022
8 Jul 2022
28 Jul 2022
12 Jul 2022
9 Jul 2022 - 11 Jul 2022
Maintenance and operation of 1 Nos of 100 KWp Solar Power Plant along with its connected equipments i.e. control panels, battery banks and PV modules etc in shift of 08 hrs per day by employing qualified or experienced technician including comprehensive maintenance of all above equipment installed at solar distribution network in HQ 7 Sect AR area by maintaining attendance register of staff employed all as specified and directed by Engr-in-charge. Contractor shall quotes his rates for maint and operation of 1 No Solar Power Plant and all other eqpt including cleaning of plant areas, monitoring/ recording of energy production/ distribution details with following terms and conditions :- (a) Contractor will produce character certificate issued by Police Station, education/ qualification certificate and experience certificate belonging minimum 02 years of the staff employed and contractor shall be responsible for any disciplinary case of staff employed. (b) Necessary life insurance will be done as per prevailing rules for tradesman employed through the job and the original policy documents will be produced for verification and record. (c) All expenditure for necessary T&P, Dress, Safely hardness Eqpt, communication, stationery, insurance of tradesman etc as per specified in this job are deemed to be included in the quoted. (d) All payments of labours will be done through Nationalized Banks and produced the bank statement to department before clearing bills. e) PENAL CHARGES :- If any of the activity above is not performed by the contractor than recovery as under will be affected :- (i) Absent on duty of Technician – Rs 1000 per shift. (ii) Not cleaning of PV Modules and Plant Areas - Rs. 2500 per plant/per month. Note :- The spares replaced under comprehensive maintenance shall be measured and paid separately. Location of the Solar Power Plant is Near Main Office, HQ 7 Sect AR
Supply, installing, testing and commissioning of Array Junction Box (AJB) as per existing size/capacity complete all as directed and specified
Supply installing, testing and commissioning of Field Junction Box (FJB) as per size/capacity complete all as directed and specified
Supply, installing, testing and commissioning of Main Junction Box (MJB) as per existing size/capacity all as directed and specified
Supply, installing, testing and commissioning of PV Modules (Photo-Voltaic Cell) as per existing size/capacity complete all as directed and specified
Supply installing, testing and commissioning of PV circuit breaker PC Box of 250 Amp capacity all as directed and specified
Supply, installing, testing and commissioning of DC/AC Voltage meter as per existing size/capacity all as directed and specified
Supply, installing, testing and commissioning of DC/AC Ampere meter as per existing size/capacity complete all as directed and specified.
Supply, installing, testing and commissioning of Solar E/fax as per existing size/capacity complete all as directed and specified
Supply, installing, testing and commissioning of LT Cable 70 Sqmm as directed and specified
Supply, installing, testing and commissioning of Solar DC cables of 6.00 sqmm complete all as directed and specified
Supplying and fixing of L & T switch gear LTMN x 140.3 Pole Tower (2 No + 2 NC) ( L & T Make)
Repair & maint of old existing inverter of system voltage 240/360/480 volts by inspecting, repair of replacement of internal part complete along with Dc wiring connection PCBs, indicators volts & Amp meters (Digital/Analogue type) and make the inverter functional by connecting to existing battery bank all as specified and directed. Note:- If the inverter is non-repairable then the same shall be replaced with hybrid type inverter of suitable capacity wart existing system voltage@ Rs. 14,50,000/-
Fixing only battery bank of suitable capacity (500/600/1000 AH) from store room to solar plant site and connecting in existing system by taking down old unserviceable battery bank from system complete & make the plant functional in all respection including connection upto inverter complete all as specified & directed. Supply, installing, testing and commissioning of DC/AC Ampere meter as per existing size/capacity complete all as directed and specified. Note:- (a) The new battery bank (500/600/1000 AH) will be supplied as schedule ‘B’ stores free for fixing only. (b) The old battery bank is issued as scheduled of credit to the contractor. (c) The battery bank qty is 180 or 240 Nos
SCHEDULE OF CREDIT:- Old unserviceable battery bank
SCHEDULE OF CREDIT:- Old unserviceable PV Modules
Imperial Solar Solutions
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .