Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.5 LAccepted-AOC BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹5.4 L+₹89,100 (19.8%)Rejected-Finance 12 BHARTI AARTIST COLONY VIKAS MARG NEW DELHI 110092 | EAST | DELHI | 110092 | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹7.9 L+₹3.4 L (74.9%)Rejected-Finance 1ST FLOOR H NO 165 GALI NO 16 S B S COLONY KARAWAL NAGAR DELHI EAST DELHI DELHI 110094 | NORTH EAST DELHI | DELHI | 110094 | L3 | Rejected-Finance Being not lowest | |
| 4 | L4₹8.0 L+₹3.6 L (79.2%)Rejected-Finance M S 4BC PITAMPURA DELHI 110034 | DELHI | NORTH WEST DELHI | DELHI | 110034 | L4 | Rejected-Finance Being not lowest | |
| 5 | L5₹8.3 L+₹3.8 L (84.9%)Rejected-Finance | L5 | Rejected-Finance Being not lowest |
| Sl No | Description | Qty | Unit | R. S. Associates L3 | K R GUPTA AND SONS L6 | Vijaypower Generators Limited L2 | Rahul Enterprises L1 | M/S SWASTIK BUILDERS L7 | Friends fire Engineers L4 | PRASHANT ENTERPRISES L5 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply Installation testing and commissioning Of retrofit emission control device for 125 kVA diesel generator of any make/modal/vintage.
Application: - Reduce particulate matter (PM 2.5), Carbon Monoxide and Hydrocarbons emitted from Diesel Engine having following features:-
(a) Min Particular Matter Reduction 80% to 90%
(b) Min Carbon Monoxide Reduction 90%
(c) Min Hydrocarbon Reduction 90%
Technology/Type: - filter less technology/ESP (Electrostatic Precipitator), Wet Scrubbing, Diesel Oxides Catalyst having following features:-
(a) Guaranteed specified Particulate matter (PM 2.5)
(b) Carbon Monoxide, Hydrocarbon reduction efficiency
(c) Retrofit device is to be installed in place of existing silencer.
(d) No soot is to be collected in the retrofit device.
(e) The device including enclosure should include an Oxidation chamber and Passive Regeneration Trap.
(f) Maximum back pressure exerted by the Emission Control retrofit device at max prescribed load by DG OEM (as per the capacity of the DG set) should be under limit and display panel to be provided for Back pressure and exhaust temperature limit.
(g) Guaranteed specified Particulate matter (PM 2.5)
(h) Carbon Monoxide, Hydrocarbon reduction efficiency
(j) Retrofit device is to be installed in place of existing silencer.
(k) No soot is to be collected in the retrofit device.
Note:- RECD shall be tested on completion of work by NABL accredated Lab in presence of GE. | 1 | Each Job | 4,10,000 ₹4,10,000 | 4,90,000 ₹4,90,000 | 3,09,000 ₹3,09,000 | 2,43,200 ₹2,43,200 Lowest | 5,75,000 ₹5,75,000 | 4,99,999 ₹4,99,999 | 3,80,000 ₹3,80,000 |
| 1.10(l)The device including enclosure should include an Oxidation chamber and Passive Regeneration Trap. (m) Maximum back pressure exerted by the Emission Control retrofit device at max prescribed load by DG OEM (as per the capacity of the DG set) should be under limit and display panel to be provided for Back pressure and exhaust temperature limit. (n) The Retrofit emission control device shall be with corrosion resistive and heat resistance paint. (o) Standard set of tools consisting of a set of 3 spanners, one screw driver, one standard plier and one nose plier of appropriate size shall be provided along with each Retrofit Emission Control Device (RECD). Make of Retrofit Emission Control Device (RECD):- (i) M/s Chakr Shield Innovation Pvt Ltd (ii) Cummins India Limited (iii) EO Energy or any other make approved by E-in-C's Branch/CPCB norms during currency of Work. Note : Retrofit Emission Control Device (RECD) shall comply all norms as per latest applicable CPCB guideline. | ||||||||||
| 1.20TEST REPORTS Certification :- Device should be ‘Type Approved’ as per the System and Procedure of Central Pollution Control Board for Emission Compliance Testing of Retro-fit Emission Control Devices (RECD) For Diesel Power Generating Set Engines, Dated 01/02/2022, wide Pollution Control Series PCLS/12/2021-22. Adhering to this, RECD to be ‘Type Tested’ for an equivalent kVA family as per the System and Procedure from any one of the Central Pollution Control Board, Govt, of India, recognized/approved test agencies/laboratories as givenas per HQ E-in-C Br policy letter No. A/37696/Gen/Pol/E2W (PPC) date 29 jun 2024 and bidder will submit RECD tested report from following CPCB recognized approved labs:- (a) Automotive Research Association of India (ARAI, Pune Maharastra) (b) International centre for automotive Testing (ICAT, Manesar) | ||||||||||
| 1.30NOTE: It is mandatory to upload the Type approval certificate for suitable KVA RATINGS (ENGINE FAMILY) with registration number & date (from one of the CPCB recognized approved lab in Cover – 1 bid with application of tender documents. If contractor failed to upload the same in Cover-1, bid will be rejected in Cover-1 and financial bid not be opened.” General Technical Requirements (GTR) / Commissioning: - (a) Emission Control retrofit device shall be complete with safety precautions to ensure no damage should be done to the DG set operations under any circumstances. The Emission Control retrofit device should be closely coupled with the DG exhaust to ensure 100% of the exhaust passes through the Emission Control retrofit device. | ||||||||||
| 1.40(b) Anti-Vibration mountings shall be provided for complete Emission Control retrofit device in case of flexible coupling with the diesel generator exhaust. (c) Emission Control retrofit device should have protection against under voltage, over voltage, under frequency, over frequency, low battery voltage, over current, earth-fault, short circuit, phase sequence change etc. (d) The Emission Control retrofit device shall be with corrosion resistive and HR paint. (e) Unloading and placement of the Emission Control retrofit device at the time of delivery is in the scope of buyer. The consignee shall ensure that the site is located along a motorable way. (f) The seller shall provide the trial run (Testing) of Emission Control retrofit device. The seller shall conduct trial run of the Emission Control retrofit device with the available electrical load at site. The trial run shall be for TWO hours. The electrical loading shall not be more than the rated capacity of the DG set. (g) Exhaust piping, extra civil work, distribution board shall be provided by the seller | ||||||||||
| 1.50Scope of Installation: - a) Installation of Emission Control Retrofit Device when offered by the vendor is inclusive in the scope of supply and shall be done by the seller. The installation work of Emission Control Retrofit Device. b) Construction of suitable earthing station (if applicable) and necessary connections shall be done by the seller. Warranty/Service - 24 months if in case Enginer get seized due to back pressure, contractor shall be at his own expense to rectify the DG set at his own cost. Number of preventive maintenance visits offered in a year during warranty period - 2 visits DELIVERABLES, TIME SCHEDULE Submission of approach of work/ methodology, Drawings and the details of team as per the Delivery Of Device - 60 days Installation, Testing Commissioning at site of retrofit emission control device on existing DG sets- 90 days | ||||||||||
| 2.00 | Supply Installation testing and commissioning Of retrofit emission control device for 62.5 kVA diesel generator of any make/vintage.
Application: - Reduce particulate matter (PM 2.5), Carbon Monoxide and Hydrocarbons emitted from Diesel Engine.
a) Min Particular Matter Reduction 85%
b) Min Carbon Monoxide Reduction 90%
c) Min Hydrocarbon Reduction 90%
Technology/Type: - ESP (Electrostatic Precipitator), Wet Scrubbing, Diesel Oxides Catalyst
a) Guaranteed specified Particulate matter (PM 2.5)
b) Carbon Monoxide, Hydrocarbon reduction efficiency
c) Retrofit device is to be installed in place of existing silencer.
d) No soot is to be collected in the retrofit device.
e) The device including enclosure should include an Oxidation chamber and Passive Regeneration Trap.
f) Maximum back pressure exerted by the Emission Control retrofit device at max prescribed load by DG OEM (as per the capacity of the DG set) should be under limit and display panel to be provided for Back pressure and exhaust temperature limit. | 1 | Each Job | 3,70,000 ₹3,70,000 | 3,90,000 ₹3,90,000 | 2,22,000 ₹2,22,000 | 1,91,000 ₹1,91,000 Lowest | 5,00,000 ₹5,00,000 | 2,99,999 ₹2,99,999 | 4,45,000 ₹4,45,000 |
| 2.10(g) the retrofit emission control device shall be with corrosion resistive and heat resistance paint. (h) Standard set of tools consisting of a set of 3 spanners, one screw driver, one standard pliers and one nose pliers of appropriate size shall be provided along with each Retrofit emission control Device(RECD). Make of Retrofit Emission Control Device (RECD):- (i) M/s Chakr Shield Innovation Pvt Ltd (ii) M/s Brooks Enviro Engineering Pvt Ltd (BEE) (iii) Cummins India Limited (iv) EO Energy or any other make approved by E-in-C's Branch during currency of Work. Note : Retrofit Emission Control Device (RECD) shall comply all norms as per latest applicable CPCB guideline. | ||||||||||
| 2.20TEST REPORTS Certification :- Device should be ‘Type Approved’ as per the System and Procedure of Central Pollution Control Board for Emission Compliance Testing of Retro-fit Emission Control Devices (RECD) For Diesel Power Generating Set Engines, Dated 01/02/2022, wide Pollution Control Series PCLS/12/2021-22. Adhering to this, RECD to be ‘Type Tested’ for an equivalent kVA family as per the System and Procedure from any one of the four Central Pollution Control Board, Govt, of India, recognized/approved test agencies/laboratories as given:below- (a) Automotive Research Association of India (ARAI, Pune) below. (b) International centre for automotive Testing (ICAT, Manesar) (c) Indian Institute of petroleum (IIP, Dehradun) (d) Vehicle Research Development Establishment (VRDE, Ahmednagar) NOTE:- It is mandatory to upload the Type approval certificate for suitable KVA RATINGS (ENGINE FAMILY) with registration number & date (from one of the CPCB recognized approved lab in Cover – 1 bid with application of tender documents. If contractor failed to upload the same in Cover-1, bid will be rejected in Cover-1 and financial bid not be opened.” | ||||||||||
| 2.30General Technical Requirements (GTR) / Commissioning: - (a) Emission Control retrofit device shall be complete with safety precautions to ensure no damage should be done to the DG set operations under any circumstances. The Emission Control retrofit device should be closely coupled with the DG exhaust to ensure 100% of the exhaust passes through the Emission Control retrofit device. (b) Anti-Vibration mountings shall be provided for complete Emission Control retrofit device in case of flexible coupling with the diesel generator exhaust. (c) Emission Control retrofit device should have protection against under voltage, over voltage, under frequency, over frequency, low battery voltage, over current, earth-fault, short circuit, phase sequence change etc. (d) The Emission Control retrofit device shall be with corrosion resistive and HR paint. (e) Unloading and placement of the Emission Control retrofit device at the time of delivery is in the scope of buyer. The consignee shall ensure that the site is located along a motor able way. (f) The seller shall provide the trial run (Testing) of Emission Control retrofit device. The seller shall conduct trial run of the Emission Control retrofit device with the available electrical load at site. The trial run shall be for TWO hours. The electrical loading shall not be more than the rated capacity of the DG set. (g) Exhaust piping, extra civil work, distribution board shall be provided by the seller. | ||||||||||
Tender Value
₹9.4 L
EMD Value
₹18,800
Closing Date
5 Jan 2026, 6:00 pmClosed
CWE(AF) Bamrauli
HO CWE(AF) BAMRAULI PRAYAGRAJ-211012
PROVN OF RECD FOR EXISTING DG SETS AT AF STATION BAMRAULI
2025_MES_744268_1
87566/C/E8
Open Tender
Civil Works
Item Rate
182 days
BAMRAULI
MES Enlisted Contractor of Class E category b i
7 documents required · 7 mandatory
₹500
GE(AF) BAMRAULI
₹18,800
Yes
11 Feb 2026
12 Dec 2025
12 Jan 2026
12 Dec 2025
5 Jan 2026
29 Dec 2025
12 Dec 2025 - 19 Dec 2025
Supply Installation testing and commissioning Of retrofit emission control device for 125 kVA diesel generator of any make/modal/vintage. Application: - Reduce particulate matter (PM 2.5), Carbon Monoxide and Hydrocarbons emitted from Diesel Engine having following features:- (a) Min Particular Matter Reduction 85% (b) Min Carbon Monoxide Reduction 90% (c) Min Hydrocarbon Reduction 90% Technology/Type: - ESP (Electrostatic Precipitator), Wet Scrubbing, Diesel Oxides Catalyst having following features:- (a) Guaranteed specified Particulate matter (PM 2.5) (b) Carbon Monoxide, Hydrocarbon reduction efficiency (c) Retrofit device is to be installed in place of existing silencer. (d) No soot is to be collected in the retrofit device. (e) The device including enclosure should include an Oxidation chamber and Passive Regeneration Trap. (f) Maximum back pressure exerted by the Emission Control retrofit device at max prescribed load by DG OEM (as per the capacity of the DG set) should be under limit and display panel to be provided for Back pressure and exhaust temperature limit. (g) Guaranteed specified Particulate matter (PM 2.5) (h) Carbon Monoxide, Hydrocarbon reduction efficiency (j) Retrofit device is to be installed in place of existing silencer. (k) No soot is to be collected in the retrofit device.
(l)The device including enclosure should include an Oxidation chamber and Passive Regeneration Trap. (m) Maximum back pressure exerted by the Emission Control retrofit device at max prescribed load by DG OEM (as per the capacity of the DG set) should be under limit and display panel to be provided for Back pressure and exhaust temperature limit. (n) The Retrofit emission control device shall be with corrosion resistive and heat resistance paint. (o) Standard set of tools consisting of a set of 3 spanners, one screw driver, one standard plier and one nose plier of appropriate size shall be provided along with each Retrofit Emission Control Device (RECD). Make of Retrofit Emission Control Device (RECD):- (i) M/s Chakr Shield Innovation Pvt Ltd (ii) M/s Brooks Enviro Engineering Pvt Ltd (BEE) (iii) Cummins India Limited (iv) EO Energy or any other make approved by E-in-C's Branch during currency of Work. Note : Retrofit Emission Control Device (RECD) shall comply all norms as per latest applicable CPCB guideline.
TEST REPORTS Certification :- Device should be ‘Type Approved’ as per the System and Procedure of Central Pollution Control Board for Emission Compliance Testing of Retro-fit Emission Control Devices (RECD) For Diesel Power Generating Set Engines, Dated 01/02/2022, wide Pollution Control Series PCLS/12/2021-22. Adhering to this, RECD to be ‘Type Tested’ for an equivalent kVA family as per the System and Procedure from any one of the Central Pollution Control Board, Govt, of India, recognized/approved test agencies/laboratories as givenas per HQ E-in-C Br policy letter No. A/37696/Gen/Pol/E2W (PPC) date 29 jun 2024 and bidder will submit RECD tested report from following CPCB recognized approved labs:- (a) Automotive Research Association of India (ARAI, Pune Maharastra) (b) International centre for automotive Testing (ICAT, Manesar) (c) Indian Oil corporation research and development centre faridabad haryana (d) Indian Institute of petroleum dehradun (UK) (e) Vehicle Research Development Establishment (VRDE, Ahmednagar)
NOTE: It is mandatory to upload the Type approval certificate for suitable KVA RATINGS (ENGINE FAMILY) with registration number & date (from one of the CPCB recognized approved lab in Cover – 1 bid with application of tender documents. If contractor failed to upload the same in Cover-1, bid will be rejected in Cover-1 and financial bid not be opened.” General Technical Requirements (GTR) / Commissioning: - (a) Emission Control retrofit device shall be complete with safety precautions to ensure no damage should be done to the DG set operations under any circumstances. The Emission Control retrofit device should be closely coupled with the DG exhaust to ensure 100% of the exhaust passes through the Emission Control retrofit device.
(b) Anti-Vibration mountings shall be provided for complete Emission Control retrofit device in case of flexible coupling with the diesel generator exhaust. (c) Emission Control retrofit device should have protection against under voltage, over voltage, under frequency, over frequency, low battery voltage, over current, earth-fault, short circuit, phase sequence change etc. (d) The Emission Control retrofit device shall be with corrosion resistive and HR paint. (e) Unloading and placement of the Emission Control retrofit device at the time of delivery is in the scope of buyer. The consignee shall ensure that the site is located along a motorable way. (f) The seller shall provide the trial run (Testing) of Emission Control retrofit device. The seller shall conduct trial run of the Emission Control retrofit device with the available electrical load at site. The trial run shall be for TWO hours. The electrical loading shall not be more than the rated capacity of the DG set. (g) Exhaust piping, extra civil work, distribution board shall be provided by the seller
Scope of Installation: - a) Installation of Emission Control Retrofit Device when offered by the vendor is inclusive in the scope of supply and shall be done by the seller. The installation work of Emission Control Retrofit Device. b) Construction of suitable earthing station (if applicable) and necessary connections shall be done by the seller. Warranty/Service - 24 months Number of preventive maintenance visits offered in a year during warranty period - 2 visits DELIVERABLES, TIME SCHEDULE Submission of approach of work/ methodology, Drawings and the details of team as per the Delivery Of Device - 60 days Installation, Testing Commissioning at site of retrofit emission control device on existing DG sets- 90 days
(g) the retrofit emission control device shall be with corrosion resistive and heat resistance paint. (h) Standard set of tools consisting of a set of 3 spanners, one screw driver, one standard pliers and one nose pliers of appropriate size shall be provided along with each Retrofit emission control Device(RECD). Make of Retrofit Emission Control Device (RECD):- (i) M/s Chakr Shield Innovation Pvt Ltd (ii) M/s Brooks Enviro Engineering Pvt Ltd (BEE) (iii) Cummins India Limited (iv) EO Energy or any other make approved by E-in-C's Branch during currency of Work. Note : Retrofit Emission Control Device (RECD) shall comply all norms as per latest applicable CPCB guideline.
TEST REPORTS Certification :- Device should be ‘Type Approved’ as per the System and Procedure of Central Pollution Control Board for Emission Compliance Testing of Retro-fit Emission Control Devices (RECD) For Diesel Power Generating Set Engines, Dated 01/02/2022, wide Pollution Control Series PCLS/12/2021-22. Adhering to this, RECD to be ‘Type Tested’ for an equivalent kVA family as per the System and Procedure from any one of the four Central Pollution Control Board, Govt, of India, recognized/approved test agencies/laboratories as given:below- (a) Automotive Research Association of India (ARAI, Pune) below. (b) International centre for automotive Testing (ICAT, Manesar) (c) Indian Institute of petroleum (IIP, Dehradun) (d) Vehicle Research Development Establishment (VRDE, Ahmednagar) NOTE:- It is mandatory to upload the Type approval certificate for suitable KVA RATINGS (ENGINE FAMILY) with registration number & date (from one of the CPCB recognized approved lab in Cover – 1 bid with application of tender documents. If contractor failed to upload the same in Cover-1, bid will be rejected in Cover-1 and financial bid not be opened.”
General Technical Requirements (GTR) / Commissioning: - (a) Emission Control retrofit device shall be complete with safety precautions to ensure no damage should be done to the DG set operations under any circumstances. The Emission Control retrofit device should be closely coupled with the DG exhaust to ensure 100% of the exhaust passes through the Emission Control retrofit device. (b) Anti-Vibration mountings shall be provided for complete Emission Control retrofit device in case of flexible coupling with the diesel generator exhaust. (c) Emission Control retrofit device should have protection against under voltage, over voltage, under frequency, over frequency, low battery voltage, over current, earth-fault, short circuit, phase sequence change etc. (d) The Emission Control retrofit device shall be with corrosion resistive and HR paint. (e) Unloading and placement of the Emission Control retrofit device at the time of delivery is in the scope of buyer. The consignee shall ensure that the site is located along a motor able way. (f) The seller shall provide the trial run (Testing) of Emission Control retrofit device. The seller shall conduct trial run of the Emission Control retrofit device with the available electrical load at site. The trial run shall be for TWO hours. The electrical loading shall not be more than the rated capacity of the DG set. (g) Exhaust piping, extra civil work, distribution board shall be provided by the seller.
Scope of Installation: - (a) Installation of Emission Control Retrofit Device when offered by the vendor is inclusive in the scope of supply and shall be done by the seller. The installation work of Emission Control Retrofit Device. (b) Construction of suitable earthing station (if applicable) and necessary connections shall be done by the seller. Warranty/Service - 24 months Number of preventive maintenance visits of
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.20 MB
BOQ_833471.xls
BOQ • 0.89 MB
87566TENDERDOCUMENTS.pdf
Tender Documents • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .