Executive Engineer
Electrical Division No.II, HPPWD, U.S. Club, Shimla-01.
Replacement of old damaged fire alarm control panel with new one in Civil Hospital Rohru District Shimla.
2026_PWD_140576_5
ED.II.TA.NIT.26-2046 dt. 03-08-2026
Open Tender
Electrical Works
Percentage
90 days
Rohru
Please refer to tender documents. Eligibility criteria is mentioned at page No. 6-7, 9-10 of GCC. Documents mentioned in eligibility criteria must be uploaded to qualify the bid.
7 documents required · 7 mandatory
₹350
₹4,100
16 Sept 2026
28 Aug 2026
7 Sept 2026
28 Aug 2026
5 Sept 2026
28 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing, fixing Testing & commissining of microprocessorbase digitally addresed heving addresable feautre(capableof giving individual addressof dectctor ) fire alrm control & indicating panel with 40x2 charecter LED display, with Rs 485 commnication for peer to peer networking between 27 Nos.control panel & 4 passive repeater, pulse timer for dual stage alarm facility complete with indicatodrs floor selector switches stand by SMF lead acid battery ( suitable for 48 hoursnormal operation & after that min 30 minutes for ful load operation) battery charger, battery box , connections to building automatic system/ fire fighting pump panel etc. & 250 watt. PA system as required complete in all respect per spacification & number in case of alarm. The main control should give a distinct visual singnal of the isulation of zone from the local indication panel . If all the zone at the local panel are isulates or if the fuse of the LCP gets blown, it should result in an open circuit fault indication at the main panel , Each zone should have provision of activation of hooter.with the existing system of AGNI (SURAKSHA) Model :PX-16E( with five year warranty) | 1 | Each | 2,04,295.76 | ₹2,04,295.76 |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.26 MB
GCC.pdf
Tender Documents • 4.80 MB
BOQ_210890.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .