| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.6 LAccepted-AOC | ₹17.6 L Quoted ₹17.9 L | L1 | Accepted-AOC L1 |
| 2 | L2₹22.2 L+₹4.3 L (23.7%)Rejected-AOC 1 6 620 CHAITANYAPURI INDRA NAGAR DILSUKHNAGAR HYDERABAD TELANGANA 500060 UDYAM TS 09 0007870 37AAEPO0535A1Z8 B 36AAEPO0535A1ZA R MSME STATUS AS VERIFIED | RANGA REDDY | TELANGANA | 500060 | ₹22.2 L+₹4.3 L (23.7%) | L2 | Rejected-AOC L2 |
| 3 | L3₹24.3 L+₹6.3 L (35.2%)Rejected-AOC | ₹24.3 L+₹6.3 L (35.2%) | L3 | Rejected-AOC L3 |
| 4 | L4₹27.7 L+₹9.8 L (54.5%)Rejected-AOC | ₹27.7 L+₹9.8 L (54.5%) | L4 | Rejected-AOC L4 |
| Sl No | Description | Qty | Unit | OM SAI POWER SYSTEMS L3 | M/S AMRIT DAS MAHAPATRA L4 | DPS sales and services india L2 | SRI SAI RAM ENTERPRISES L1 |
|---|---|---|---|---|---|---|---|
| 1.00NOTES :- 1. Contractor need to purchase minimum 50% of all items mentioned in this CA within 20 days of getting sample approval and kept in custody so that no delay in work due to non-availability of materials will be faced. Contractor should ensure during the cause of work that he has minimum 25% of materials with him till the completion of item/date. 2. Contractor should buy the exact items which are given with catalogue reference. Other makes will be approved only by submitting non availability Certificate Company. Contractor need to remove all the dismantled items without delay. 3. Rate quoted for demolition/dismantling /taking down is inclusive of removing the same from site and dumping at given locations anywhere inside station. 4. Contractor will make his own arrangement to store his items. 5. Some places in this contract where the vehicle will not reach the spot directly, the material will be moved manually in these places. The rate quoted will be considered all inclusive on this account. 6. All trade skilled labour required in this contract shall be present daily in working hours, irrespective of complaints received. 7. Complaint for a similar items may be in scattered / different area, quoted rate will be considered all inclusive on this account. | |||||||
| 1.01 | Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M in depth and getting out in soft/loose soil for laying of under ground cable and foundation of poles.etc complete as specified and as directed. | 447 | Cum | 120 ₹53,640 Lowest | 270 ₹1,20,690 | 388 ₹1,73,436 | 275 ₹1,22,925 |
| 2.00 | Excavation in trenches not exceeding 1.5M wide and beyond 1.5M in depth and getting out in soft/loose soil for laying of under ground cable and foundation of poles.etc complete as specified and as directed. | 0.2 | Cum | 345 ₹69 | 280 ₹56 Lowest | 754 ₹150.8 | 600 ₹120 |
| 3.00 | Returning filling in including spreading, leveling watering and well ramming in layers not exceeding 25 Cm thick .etc complete as specified and as directed. | 297 | Cum | 10 ₹2,970 Lowest | 45 ₹13,365 | 100 ₹29,700 | 60 ₹17,820 |
| 4.00 | Removal of excavated surplus soil not exceeding 50 m and depositing where directed at al level not exceeding 1.5 m above the starting point and all as specified and as directed. | 150 | Cum | 25 ₹3,750 Lowest | 100 ₹15,000 | 100 ₹15,000 | 60 ₹9,000 |
| 5.00 | Supply and spreading clean dry sand in trenches for cushioning all as specified for cable protection in trenches / ducts complete all as directed.
(Note: The punned down thickness shall only be measured) | 126 | Cum | 750 ₹94,500 | 1,250 ₹1,57,500 | 1,000 ₹1,26,000 | 600 ₹75,600 Lowest |
| 6.00 | Supply and lay common burnt clay building bricks sub class 'B' of designation 75 laid in trenches as protection to cables complete all as specified and as directed. | 12,408 | Each | 9 ₹1,11,672 | 9 ₹1,11,672 | 9 ₹1,11,672 | 6 ₹74,448 Lowest |
| 7.00 | M&L for road cutting /Hard standing for taking up or laying of LT UG Cable upto a depth of 15cm, after laying of cable well ramming to the excaved soil and repair the excavated portion of the road as existing or by providing suitable mixture of PCC complete all as specified and directed | 60 | RM | 50 ₹3,000 Lowest | 730 ₹43,800 | 310 ₹18,600 | 150 ₹9,000 |
| 8.00 | M&L for Plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundation of steel poles/struts as specified including necessary form work all as specified and as directed. | 3.5 | Cum | 2,150 ₹7,525 Lowest | 5,000 ₹17,500 | 3,330 ₹11,655 | 4,000 ₹14,000 |
| 9.00 | M&L for cement concrete (1:2:4) type B1 with 20 mm graded aggegate for coping including form work and finishing to all exposed surfaces by using extra cement all as directed. | 0.5 | Cum | 2,850 ₹1,425 Lowest | 5,500 ₹2,750 | 3,885 ₹1,942.5 | 6,000 ₹3,000 |
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
14 Aug 2025, 6:00 pmClosed
GE (AF) Hakimpet
Secunderabad
REPAIR, MAINTENANCE TO LT PANEL BOARDS, UG CABLES, SWITCHGEAR, APFC PANEL AND CONNECTED ALLIED WORKS AT AFS BEGUMPET, CAW AND ORC ENCLAVE UNDER GE (AF) HAKIMPET
2025_MES_721039_1
8806/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Begumpet and CAW
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Hakimpet
₹56,000
Yes
14 Oct 2025
17 Jul 2025
16 Aug 2025
17 Jul 2025
14 Aug 2025
31 Jul 2025
Amount
NOTES :- 1. Contractor need to purchase minimum 50% of all items mentioned in this CA within 20 days of getting sample approval and kept in custody so that no delay in work due to non-availability of materials will be faced. Contractor should ensure during the cause of work that he has minimum 25% of materials with him till the completion of item/date. 2. Contractor should buy the exact items which are given with catalogue reference. Other makes will be approved only by submitting non availability Certificate Company. Contractor need to remove all the dismantled items without delay. 3. Rate quoted for demolition/dismantling /taking down is inclusive of removing the same from site and dumping at given locations anywhere inside station. 4. Contractor will make his own arrangement to store his items. 5. Some places in this contract where the vehicle will not reach the spot directly, the material will be moved manually in these places. The rate quoted will be considered all inclusive on this account. 6. All trade skilled labour required in this contract shall be present daily in working hours, irrespective of complaints received. 7. Complaint for a similar items may be in scattered / different area, quoted rate will be considered all inclusive on this account.
Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M in depth and getting out in soft/loose soil for laying of under ground cable and foundation of poles.etc complete as specified and as directed.
Excavation in trenches not exceeding 1.5M wide and beyond 1.5M in depth and getting out in soft/loose soil for laying of under ground cable and foundation of poles.etc complete as specified and as directed.
Returning filling in including spreading, leveling watering and well ramming in layers not exceeding 25 Cm thick .etc complete as specified and as directed.
Removal of excavated surplus soil not exceeding 50 m and depositing where directed at al level not exceeding 1.5 m above the starting point and all as specified and as directed.
Supply and spreading clean dry sand in trenches for cushioning all as specified for cable protection in trenches / ducts complete all as directed. (Note: The punned down thickness shall only be measured)
Supply and lay common burnt clay building bricks sub class 'B' of designation 75 laid in trenches as protection to cables complete all as specified and as directed.
M&L for road cutting /Hard standing for taking up or laying of LT UG Cable upto a depth of 15cm, after laying of cable well ramming to the excaved soil and repair the excavated portion of the road as existing or by providing suitable mixture of PCC complete all as specified and directed
M&L for Plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundation of steel poles/struts as specified including necessary form work all as specified and as directed.
M&L for cement concrete (1:2:4) type B1 with 20 mm graded aggegate for coping including form work and finishing to all exposed surfaces by using extra cement all as directed.
M&L for 80 mm bore galvanized iron light grade pipe for cable protection complete with all fittings fixed to wall or laid in floor/road crossing or on pole including taking down U/S complete all as specified and directed
All as per Item No 10 herein befor but for 50mm bore
All as per Item No 10 herein befor but for 40mm bore
Supply and Lay 10 Sqmm 2 Core of 1100 volts grade LT UG Cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor, laid in trenches/ducts, fixed on wall/inside panel, drawn through pipe including takingout the old unsv LT cable complete all as specified and directed Note : Rate deemed to be inclusive of conecting up with control gear including cable glands and cable lugs
All as per Item No 13 hereinbefore but 16 Sqmm 4 core all as specified and directed
All as per Item No 13 hereinbefore but 25 Sqmm 3½ core all as specified and directed
All as per Item No 13 hereinbefore but 50 Sqmm 3½ core all as specified and directed
All as per Item No 13 hereinbefore but 70 Sqmm 3½ core all as specified and directed
All as per Item No 13 hereinbefore but 95 Sqmm 3½ core all as specified and directed
All as per Item No 13 hereinbefore but 120 Sqmm 3½ core all as specified and directed
All as per Item No 13 hereinbefore but 150 Sqmm 3½ core all as specified and directed
All as per Item No 13 hereinbefore but 185 Sqmm 3½ core all as specified and directed
All as per Item No 13 hereinbefore but 300 Sqmm 3½ core all as specified and directed
Supply and install steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts, nuts and screws as specified type 410SP-31 (9.0 meter long) and including painting with two coats of aluminium paint over one coat of red oxide and black bituminous paint on the hidden surface in foundation including drilling of holes for fixing of D Iron clamp and holes for continous GI earth wire as required complete including dismantling of old unsv steel poles/ PCC Pole/struts any size all as specified and directed
Supply and fix in repair Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including dismantling of cross arms of MS channel or angle sections etc complete all as directed
M&L for earthing complete with galvanized steel earth plate electrode of size 600mm x 600mm x 6mm thick, buried directly in ground vertically to a depth not less than 2.25 Mtr below ground with top edge of the earth plate not less than 1.5 mtr below normal ground level, Earth plate shall be connected with double bolts, nuts, check nuts & washers, to & including 32x6 mm galvanized iron strip as earth lead, extended upto 7.5 m 'or' upto test terminal point, drawn through 40mm dia light grade GI pipe for protection of galvanized iron strip in the ground, further connecting with suitable size of earth strip to LT Panel, Transformer, DBs etc., including excavation, earth work, magnesium sulphate-50 Kg and charcoal in alternate layers on all sides sorrounding the earth plate, bentonite-25 Kg clay mixed with water and loomy soil sorrounding the plate on all sides, all as specified, PCC chamber, RCC cover slab, watering pipe 20mm dia bore med. grade, wire net, funnel etc. & testing on completion all as specified in plate No.3 of SSR Pt-I, including breaking and removing the old unsv earth materials complete all as specified and as directed. Note :- Excavation earth work and GI strip upto 7.5 mtr incl in the job.
S&F in repair Galvanised iron strip 32x6 mm as earth continuity or main earthing lead fixed to wall / pole / buried in ground etc incl taking out unsv earth strip complete all as specified and directed
Supply, mixing and pouring of mixture of Bentonite and Magnesium sulphase of 5 Kg each either in the existing water pipe or by making holes around the earthing pit for improving the earthing value complete all as specified and directed by Enginner-in-Charge
Stringing and fixing only in position of existing sagged ACSR conductor in OH line of LT/ Street light conductors including binding with aluminium wire complete all as specified and as directed . Note. The item will be measured in span lenght. The approx span length is 30mtr to 40 mtr.
Locating and pin point electric Fault precisely on LT (1100V) UG Cable of size upto 16 Sqmm 4 core under ground cable fault, locating system which is the most advanced system in power cable fault detection combining the best in market technologies in to a single fully automatic centralized setup with high reliability and multi level safety standards complete all as specified and directed .
All as per Item No 29 herein before but for LT (1100V) UG Cable of size 25 x 3.5 Core to 50 Sqmm 3.5 C Complete all as specified and directed.
All as per Item No 29 herein before but for LT (1100V) UG Cable of size 70 x 3.5 Core to 300 Sqmm 3.5 C Complete all as specified and directed.
Cutting and removing the damaged portion of the LT Cable, Supply, prepare and connect cable jointing kit for 1.1 KV grade cable for heat shrink type straight through joint complete with jointing material and accessories suitable for XLPE, armoured aluminium conductor cable of Size 4 x 16 Sqmm complete all as specified and as directed. Note. Earth work will be measured and paid seperately under relevant item of BOQ.
Description all as per Ser Item No 32 above but for cable of size 3.5/4 C x 25 Sqmm to 3.5 x 70 Sqmm complete all as specified and directed
Description all as per Ser Item No 32 above but for cable of size 3.5 C x 95 Sqmm to 3.5 x 300 Sqmm complete all as specified and directed
Repairs and Maint of LT Feeder pillar Boxes , replacing the unserviceable door hinges, locks , cutting the burnt portion of cable / lugs and crimping with new lugs of suitable size and connecting and painting the Feeder Pillar Box with approved colour
Taking down change over switch and S&F new onload change over switch 100 Amps with sheet metal enclosure, TPN 415 Volts, 50 Hz, AC of the following sizes complete all as specified and as directed
Taking down change over switch and S&F new onload change over switch 200 Amps with sheet metal enclosure, TPN 415 Volts, 50 Hz, AC of the following sizes complete all as specified and as directed
S&F Bus Bar Chamber 63 Amps 4 Way , 3 Phase 4 Wire system complete including mounting arrrengement and connections of cable and taking down old unsv bus bar chamber complete all as specified and directed . Make : Havels Cat Part No -IHBC006304 or equivalent in L&T and Legrand
S&F new MCCBs, 3 Pole , 415 Volts, to suit in the panel as existing type and model, including modification to the panel as required of capacity 25 to 100 Amps fixed type of breaking capacity 16 KA including taking down old U/S complete all as specified and directed .
S&F new MCCBs, 3 Pole , 415 Volts, to suit in the panel as existing type and model, including modification to the panel as required of capacity 125 Amps fixed type of breaking capacity 16 KA including taking down old U/S complete all as specified and directed .
S&F new MCCBs, 4 Pole , 415 Volts, to suit in the panel as existing type and model, including modification to the panel as required of capacity 160 Amps adjustable type of breaking capacity 36 KA including taking down old U/S complete all as specified and directed .
S&F new MCCBs, 4 Pole , 415 Volts, to suit in the panel as existing type and model, including modification to the panel as required of capacity 200 Amps of breaking capacity 36 KA including taking down old U/S complete all as specified and directed .
S&F new MCCBs, 3 Pole , 415 Volts, to suit in the panel as existing type and model, including modification to the panel as required of capacity 250 Amps of breaking capacity 36 KA, including taking down old complete all as specified and directed .
S&F new MCCBs, 3 pole, 415 volts, of existing type and model suitable for panel mounting of capacity 320 Amps, breaking capacity 36 KA including taking down old U/S complete all as specified and as directed.
S&F new MCCBs, 4 Pole , 415 Volts, to suit in the panel as existing type and model, including modification to the panel as required of capacity 400 Amps of breaking capacity 36 KA, including taking down old U/S complete all as specified and directed .
S&F new MCCBs, 4 Pole , 415 Volts, to suit in the panel as existing type and model, including modification to the panel as required of capacity 630 Amps of breaking capacity 50 KA including taking down old U/S complete all as specified and directed .
M&L for cutting , cleaning vegetation and bushes in and around the Sub Station areas complete all as specified and directed
Cable route indicators made out of PCC fixed vertically in gound alongwith span of line with mentioning letters indicating type of cable grade on exposed portion including excavation and refilling etc all as specified
M&L for painting the external exposed surfaces of steel tubular sewaged / rails pole of 9/11 mtrs long alongwith cross arm,brackets and connected accessories with one coat of aluminium paint including preparation of old painted surfaces and pasting radium red stickers / paint with 3 lines around the pole and numbering of pole with synthetic enamel whilte paint on black base complete all as specified and directed
DPS sales and services india (BID ID -3394186)
OM SAI POWER SYSTEMS (BID ID -3381927)
M/S AMRIT DAS MAHAPATRA (BID ID -3394322)
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .