Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.7 LAccepted-Finance A 20 COMMERCIAL COMPLEX DR MUKHERJEE NAGAR KINGSWAY CAMP DELHI 110009 | NORTH | DELHI | 110009 | L1 | Accepted-Finance Lowest Rate | |
| 2 | L2₹13.0 L+₹1.3 L (10.7%)Rejected-Finance B 246 FARMER APPTT SEC 13 ROHINI DELHI 85 | 85 | L2 | Rejected-Finance Not L1 | |
| 3 | Rejected-Technical B 17 2 GALI NO 20 JITAR NAGAR NEAR PARVANA ROAD KRISHNA NAGAR EST DELHI 51 | NEW DELHI | DELHI | 110001 | - | Rejected-Technical All documents are not correct | |
| 4 | Rejected-Technical H NO 732 BURARI VILLAGE DELHI 110084 | NORTH | DELHI | 110084 | - | Rejected-Technical All documents are not correct |
Tender Value
₹13.4 L
EMD Value
₹26,800
Closing Date
27 Mar 2023, 1:00 pmClosed
EEE-II/SSZ
OFFICE OF THE Ex. ENGINEER (ELECT)-II/SLF 2 nd Floor Technical Laboratory Near NH-24 Ghazipur Delhi
Engagement of wireman, electrical beldar for operation of PSS(Packaged sub station) HT andLT panels and other Electrical accessories etc. installed at SLF Bhalswa in Ward no 20 under CL Zone. Sub-Head Engagement of wireman and electric beldar only
2023_MCD_149641_1
EE (Elect)-II//2022-23/23.1
Open Tender
Electrical Works
Item Rate
395 days
work
Please refer to tender documents
5 documents required · 5 mandatory
₹500
₹26,800
6 Apr 2023
21 Mar 2023
28 Mar 2023
21 Mar 2023
27 Mar 2023
21 Mar 2023
Amount
PART A Engagement of wireman, electrical beldar for day to day maintenance of Electrical accessories etc. installed at SLF Bhalswa and attending day to day complaints as per following Staff as required: (a) Skilled (Wireman ) for One year in general shift.
(b) Un-Skilled (Electrical Beldar) for One year in general shift.
PART B Supply of XLPE insulated PVC sheathed Al conductor armoured cable 1.1 KV grade confirming to IS 7098 of following sizes (a)2Cx16 sqmm
(b)2Cx35sqmm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct as required. Up to 35 sqmm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.(a)Upto 35 sq. mm
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal)
S/I/T/C of surface mounting CRCA housing 36 watt LED luminaire with acrylic cover diffuser with following specification,including fixing on existing wall/surface with connection as required Total system wattage= 36 watt +/- 5% Luminous efficacy lumens/watt >=95 lumens/watt power Factor >=0.95
S/I/T/C of 150 watt LED flood light luminaire fitted with lense,made of pressure die cast alluminium housing&toughened glass cover complete with the following specifications as required :- Total system wattage= 150 watt +/- 5% Luminous efficacy >=100lumens/watt power Factor >=0.95 protection class-IP66
S/I/T/C of LED Tube type luminaire 20 Watt rating complete with Extruded Aluminium Batten prewired with high efficient LEDs with the following: Total system wattage 20 watt +/- 5% Luminous efficacy lumens/watt >=95 Power Factor >=0.95
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required,(a)100 A, 16 KA,TPMCCB
(a)200 A, 16 KA,TPMCCB
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) single pole
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required a) 40 amps
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. b) 63 amps
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (a)5/6 A switch
(b)3 pin 5/6 A socket outlet
© 15/16 A switch
(d) 6 pin 15/16 A socket outlet
S & F of Step Type Electronic Fan Regulator (Medium Size) on existing switch board i/c connections as reqd.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (a)3 X 2.5 sq. mm
©3 X 4 sq. mm
(d)6 X 4 sq. mm
(e)3X 6 sq. mm
M/s Oberoi Electricals
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .