Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹12.3 LAccepted-AOC UC I USHA PARK HARI NAGAR NEW DELHI 64 | NEW DELHI | DELHI | 110001 | 1 | Accepted-AOC L1 |
Tender Value
₹12.6 L
EMD Value
₹25,277
Closing Date
17 Oct 2023, 11:00 amClosed
EEE-III/RZ
EEE-III/RZ
Provision of Electrical Installation an other allied works in JE Store, Works Deppt. Near Vishwakarma Palace,Sec-4 Rohini, Main Mubarakpur Road Ayurvedic Dispensary near Vorter I.D card office, N Block Mangolpuri, JE Office Jalebi Chowk Sultun puri,
2023_MCD_170472_1
EEE-III/RZ/TC/2023-24/10.1
Open Tender
Electrical Works
Item Rate
240 days
EEE-III/RZ
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
₹25,277
17 Apr 2025
11 Oct 2023
18 Oct 2023
11 Oct 2023
17 Oct 2023
11 Oct 2023
Amount
OD9039/2023-2024:SR22 (1.10.3) Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc.as required.Group C
OD9040/2023-2024:SR22 (1.24.1) Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required (a) 5/6 A switch
OD9041/2023-2024:SR22 (1.24.4) Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required (a) 3 pin 5/6 A socket outlet
OD9042/2023-2024:SR22 (1.14.2) Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2X 2.5sq. mm + 1 X 2.5 sq. mm earth wire
OD9043/2023-2024:SR22 (1.12) Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
OD9044/2023-2024:SR22 (1.32) Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required
OD9045/2023-2024:DSR-22 (2.3.3)Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (b) 12 way Double door
OD9046/2023-2024:DSR-22 (2.3.2) Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (b) 8 way Double door
OD9047/2023-2024:SR22 (2.14.2) Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.( B) 40A
OD9048/2023-2024:DSR-22 (2.10.1) Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole.
OD9049/2023-2024:DSR-22 (2.12.2) Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. A)63 A.
OD9050/2023-2024:DSR-22 (7.7.1) Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Up to 35 sq. mm (clamped with 1mm thick saddle)
122.1.1:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*4 sqmm
OD9051/2023-2024:DSR-22 (5.1) Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
OD9052/2023-2024:DSR-22(5.15) Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
OD9056/2023-2024:SR22 (1.58) Supplying and fixing PVC batten/ angle holder including connection etc. as required.
OD9053/2023-2024:SR 22 (19.1) Supply, Installation, Testing and Commissioning of 1200mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
OD9054/2023-2024:DSR-22( 1.50.1) Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Up to 450 mm sweep
122.1.41:Supply of 9 Watt LED retrofit lamp suitable for B22 holder
OD9057/2023-2024:Supply of 15"(380mm) Sweep 1400 r.p.m. exhaust fan heavy duty complete with shutter, blade etc. as required
122.2.39:S/I/T/C of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following:(a) Total system wattage 20 watt +/- 5%(b )Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95
122.2.28:SITC of 60W LED Flood Light luminiare fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =60 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66
122.2.2: P/F Hot press sheet moulded compound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof pole box of inner dimension 200x160x98mm (NS) complete with suitable arrangement for fixing of 2 nos of 6 to 32 amp single pole MCB & 63 Amp. Double pole isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc as reqd. as reqd.
122.2.38:S/I/T/C of Surface mounting CRCA housing 36W LED luminaire with acrylic cover diffuser with following specifications including fixing on existing wall/recess with connections as reqd. (a)Total system wattage = 36 watt +/- 5% (b )Luminous efficacy >=95 lumens /watt. (c)Power factor >=0.95
OD9118/2023-2024:SITC of single phase mono block pump set complete with all accessories workable on 240/415 volt, 50 Hz ac supply a)1.H.P (0.75 W) single phase pump set head from 12 meter suction and delivery 25x25mm
10.18:Providing and fixing circular / hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing .
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .