CWE (AF) Bhisiana
HQ CWE (AF) Bhisiana
REPAIR/ MAINTENANCE/ IMPROVEMENT OF HT ELECTRICAL POWER SUPPLY DISTRIBUTION SYSTEM AT AF STATION SIRSA
2020_MES_400225_1
CWE(BHI)/SIR-31/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AFS Sirsa
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE AF Sirsa
₹40,000
Yes
15 Feb 2021
3 Dec 2020
31 Dec 2020
3 Dec 2020
29 Dec 2020
17 Dec 2020
3 Dec 2020 - 11 Dec 2020
60 days
Amount
Material and labour for Taking out trolley of vacuum circuit breaker 400/630/800 Amps 11 KV from the cabinet and opening top cover, de-carbonizing moving and fixed contacts if required, lubricating, inspecting the wiring of Micro processor Earth Fault and Over Current relays, tripping coil electrical, indication systems and checking for manual/auto tripping system, meggaring all the contacts and placing back the breaker trolley in its original position including removing all the dust form the VCB cabinates complete all as specified and directed. Note:- (i). All Vacuum Circuit Breaker are 11 KV of Capacity 400/630/800 Amps.
Material and labour for replacement of bakelite kit kat with 2/5/10 amps HRC fuse complete all as specified and as directed.
Material and labour for replacement of indicator lamp LED 110 Volt AC with holder (R/Y/B in colour) complete all as specified and as directed.
Material and labour for replacement of indicator lamp LED 24 Volt DC with holder (R/Y/B in colour) complete all as specified and as directed.
Material and labour for replacement of motor and gear assembly 110 volts AC/24V DC complete all as specified and as directed.
Material and labour for replacement of TNC switch of capacity 25 Amp, 2NO + 2NC with barrel lock complete all as specified and as directed.
Material and labour for Callibration of microproccessor Earth Fault and Over Current relay with portable relay test kit to set time and fault level and adjustment of setting with according to load & time with Dakshin Haryana Bijli Board and 33 KV Power House for proper functioning of electrical insfrastructure complete all as specified and directed.
Material and labour for Supply and Topping up of Insulating oil with intial di- electric strength up to 50 KV. Make : Power/Castrol/HP/Servo. Note: (a) Transformer oil will be filled in 200 ltrs Sealed drums and drums will be deposited to E/M Store yard.
Material and labour for De-hydration and filtration of Transformer Oil by using dehydration and filtration plant, heating and filtration of oil to be carried out till the di-electric strength reaches 55 KV to 60 KV withstand for one minute is achieved for any capacity of transformer complete all as specified and directed.
Material and labour for taking of sample of insulating oil from Transformer and check the Acid Test of insulating oil for any capacity of transformer complete all as specified and directed.
Material and labour for Opening the front and rear cabinate of the RMU 3 way 400/630 Amps 11 KV de-carbonizing of moving and fixed contacts and replacement of the same if found unserviceable under relevant items, lubricating, checking the pressure of SF-6 gas, wiring with suitable size of copper conductor cable, checking of micro processor EF/OC relay, tripping coil electrical and checking for manual/auto tripping system complete and placing the SF-6 RMU and isolating unit in its original position all as specified and as directed. Note:- (i). All Ring Main Units are 11 KV of Capacity 400/630 Amps.
Material and labour for replacement of Cable jointing kit for 33 KV (Earthed) grade cable for outdoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 300 sqmm.
Material and labour for replacement of Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 120 sqmm.
Material and labour for replacement of Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 120 sqmm.
Material and labour for replacement of Cable jointing kit for 11 KV (Earthed) grade cable for straight through termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 120 sqmm.
Material and labour for replacement of Copper Bus Bar of Capacity 630 Amps for 11 KV grade with insulated sleeve with accessories complete all as specified and as directed.
Material and labour for taking out of insulating oil from voltage stabilizer and De-hydration with filtration of Insulating Oil by using dehydration and filtration plant, heating and filtration of oil to be carried out till the di-electric strength reaches 55 KV to 60 KV withstand for one minute is achieved for any capacity of voltage stabilizer and filling of insulating oil complete all as specified and directed.
Material and labour for Dismantling top cover of transformer 11/ 0.433 KV of capacity up to 400 KVA , any make for repair / replacement of HT / LT bushing, top cover gasket, inspection of transformer and minor internal repairs of transformer all including draining carefully transformer oil as required / upto the required level and refilling the same, re fixing the top cover of transformer after completion of the work including testing on completion complete all as specified and directed. Note: Spare parts will be measured and paid separately from Items No. 19 to 23 against relevant items as mentioned below.
Material and labour for replacement of HT bushings with brass terminal, 6 Nos. brass nuts and washers, gaskets, insulator etc suitable for 63KVA to 160KVA transformer complete all as specified and directed.
All as per item No. 19.00 here-in-before but of capacity 200 KVA to 400 KVA.
Material and labour for replacement of LT bushings with brass terminal, 8 Nos. brass nuts and washers, gaskets, insulator etc suitable for 63KVA to 160KVA transformer complete all as specified and directed.
All as per item No. 21.00 here-in-before but of capacity 200 KVA to 400 KVA.
Material and labour for replacement Numerical 3 phase over current and earth fault relay with trip circuit supervision, true RMS measurement, self-diagnostics feature, built in CB fail protection, fault data retrievable through communication, low AC and DC burden, 5A current setting, Data communication facility complete with connection and testing on complition complete all as specified and as directed.
VERMA BROTHERS
BS BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .