Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.0 LAccepted-AOC | L1 | Accepted-AOC Awarded being 1st Lowest Bidder | |
| 2 | L2₹33.8 L+₹1.2 L (3.72%)Rejected-Finance | L2 | Rejected-Finance Awarded being 2nd Lowest Bidder | |
| 3 | L3₹33.9 L+₹1.3 L (4.06%)Rejected-Finance KOTHI NO 766 PHASE III MODEL TOWN BATHINDA PB | L3 | Rejected-Finance Awarded being 3rd Lowest Bidder | |
| 4 | L4₹37.6 L+₹4.9 L (15.2%)Rejected-Finance 18969 A 1 SHRI GURU TEG BAHADUR NAGAR BIBIWALA ROAD STREET NO 15 BATHINDA 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L4 | Rejected-Finance Awarded being 4th Lowest Bidder | |
| 5 | L5₹38.2 L+₹5.6 L (17.2%)Rejected-Finance | L5 | Rejected-Finance Awarded being 5th Lowest Bidder |
Tender Value
₹43.1 L
EMD Value
₹86,300
Closing Date
9 Mar 2024, 6:00 pmClosed
Major S K Yadav GE(S) BATHINDA
GE(S) Bathinda Bathinda Mil Stn
GE(S) BTD TOKEN NO 86 OF 2023-24 PROVISION OF CERTAIN SPECIAL REPAIR AND REVENUE WORKS UNDER AGE BR I AND AGE EM IV UNDER GE (SOUTH) BATHINDA AT BATHINDA MILITARY STATION
2024_MES_642162_1
GE(S)/BTD/TOKEN NO 86 OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
GE(S) Bathinda
Class D
Category a(i) and b(i)
11 documents required · 11 mandatory
₹500
GE(S) Bathinda
₹86,300
Yes
22 Mar 2024
13 Feb 2024
12 Mar 2024
13 Feb 2024
9 Mar 2024
24 Feb 2024
Amount
Excavation over areas not exceeding 1.5 mtr deep in soft/loose soil and getting out of soil complete all as specified and directed.
Exacavation of areas exceeding 1.5 mtr and not exceeding 3.0 mtr deep in soft/loose soil and getting out of soil complete all as specified and directed.
Exacavation of areas exceeding 3.0 mtr and not exceeding 4.5 mtr deep in soft/loose soil and getting out of soil complete all as specified and directed.
Exacavation of areas exceeding 4.5 mtr and not exceeding 6.0 mtr deep in soft/loose soil and getting out of soil complete all as specified and directed.
M & L for PCC 1:3:6 type B-2 using 40mm graded crushed stone aggregates as in foundation filling, sub-base and mass concrete complete all as specified and directed.
M & L for PCC 1:2:4 type B-2 using 40mm graded crushed stone aggregates as in foundation filling, sub-base and mass concrete complete all as specified and directed.
M&L 40mm thick cemement concrete type B-1, 1:2:4 (20 mm graded stone aggregate) as floors, sub-floors etc and finishing surfaces of concrete topping as even & fair or even & rough to receive the topping layer all as specifed
M & L for hard core of broken bricks of gauge not exceeding 63 mm, deposited, spread and leveled in layers n.exc 15 cm thick, watered and rammed complete all as specified and directed.
M & L for brick work with sub class ‘B’ bricks old size, straight or curved on plan exc 6 metre mean radius in CM 1: 4 complete all as specified and directed.
M & L for Brickwork with sub class ‘B’ bricks in one brick thick honey comb walling, built in CM 1:4 complete all as specified and directed.
M & L for loose filling with broken bricks of gauge 80 to 150mm in sokage pits, sokage wells complete all as specified and directed.
Use and waste of form work to soffits of suspended slab such as roof slab, floor slab, landing and similar work not exceeding 200 mm thick for rough finished surfaces complete all as specified and directed.
Use and waste of form work to sides of concrete flats and similar work exc 10 cm but not exceeding 20 cm wide for rough finish surface complete all as specified and directed.
S & F mild steel TMT bars 6 to 8mm mm dia cut to length, bent to shape required, including cranking, bending spirally hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
All as per item No. 14 here-in-before but 10mm dia and over complete all as specified and directed.
S & F MS rungs of 20mm dia bar etc all as specified and directed by Engineer-in-charge
M & L for rendering 15 mm thick on fair faces of brick works masonry or concrete surfaces in CM 1:4 finished the surface even & smooth without using extra cement complete all as specified and directed.
M & L for RCC M-25 Design Mix as in slabs supported on walls, beams & columns in roofs, balconies and in shelves and the like complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick soft/loose soil complete all as specified and directed.
Removal of excavated material n.exc 50 mtr away depositing where directed at a level not exceeding 1.5 metre above the starting point all as specified and directed by Engineer-in charge.
S&F cast iron sand cast 100mm size soil waste or vent pipe without ears with cement joint laid in wall/floors/trenches.
S & F in repair cast iron soil waste and vent pipe 75mm bore with or without ears fixed with chemical cement joints laid in trenches/floors or fixed in walls, all as specified.
S & F in repair cast iron soil waste and vent pipe 100mm bore with or without ears fixed with chemical cement joints laid in trenches/floors or fixed in walls, all as specified.
S & F in repairs CI bends any radius, 100mm bore, diminishing pieces or tapers, etc with or without oval access doors, complete all as specified
S & F in repairs CI bends any radius, 75mm bore, diminishing pieces or tapers, etc with or without oval access doors, complete all as specified
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for foundation etc for shaft, wells, cesspits, man holes, septic tanks etc, not exceeding 10 sqm on plan & not exceeding 1.5 mtr in depth in soft/loose soil and getting out of soil including trimming of sides complete all as specified and directed.
Excavation in trenches exceeding 1.5 mtr wide and not exceeding 3.0 mtr deep for foundation etc for shaft, wells, cesspits, man holes, septic tanks etc, not exceeding 10 sqm on plan in soft/loose soil and getting out of soil including trimming of sides complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 using 40 mm graded stone agg to drain pipe including packing under and haunching against the side of of pipe 150 mm dia (internal) after these are laid in trenches complete all as specified and directed
M&L for 150 mm dia (internal) SGSW pipes of grade ‘A’ laid in trenches and jointed complete all as specified and directed
M & L for PCC 1:3:6 type B-2 using 40mm graded crushed stone aggregates as in foundation filling, sub-base and mass concrete complete all as specified and directed.
M & L for 50 mm thick PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in flooring, finished even and smooth without using extra cement complete all as specified and directed.
M & L for precast concrete slab in cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregates set and jointed in CM 1:4 complete all as specified and directed.
M & L Cement Concrete type B1 , 1:2:4 mix (20mm graded crushed stone aggregate ) as in bedding , benching of manholes , copings, roof kerbs and surface channel etc. complete all as specified and directed.
De- sludging of existing manholes /septic tanks and soakage wells of any capacity size and depth including disposal of sludge etc and taking off the manhole cover and placing in the same position after taking out sludge through mechnically sewage suction pump and dividely store in covered container etc complete and removing the sludge in covered van/trolly outside the MD land acomplete all as specified and directed. Nate :- Dewatering of existing manhole/septic tank will not be measured only solid material will be measured.
De-watering from existing soak wells of any capacity size and depth including taking off the manhole cover and placing in the same position after taking out waste water through mechnically sewage suction pump and dividely store in covered container etc complete and removing the water in covered van/trolly outside the MD land complete all as specified and directed.
Cutting into existing manholes / septic tank for connecting new drains of size 150 mm, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B-l smooth finished, and reforming benching as required complete all as specified and as directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar of any dia set in cement , laid in trenches including all fittings and accessories complete all as specified and directed.
Demolition of brick work or stone / boulder masonary, built in cement mortar including all quoins, arches, pillars etc., in foul condition complete all as specified and directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and directed.
Excavating in Post holes soft/loose soil (or simillar holes ) n exc 0.5 cum getting out returning filling in and reaming earth or broken rubble mixed with earth around , in layers n exc 25 cum watering and removing surplus soil to a distance n. exc. 50 m and making good surface complete all as specified and directed.
S &F roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channelor flat sections) including distance pieces, cleats etc. complete all as specified and directed.
M&L preparing steel surfaces over 10cm width or girth and applying two coat synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M & L for 75mm thick PCC 1:4:8 type B-2 cement concrete in foundations, filling and mass concrete complete all as specified and directed.
M & L for 25 mm thick PCC type B-0, 1:2:4 (20mm graded aggregate) complete all as specified and directed.
M&L chequered cement concrete tiles with grey cement and pigments, 25cmx25cmx25mm/ 30cmx30cmx25mm thick, coloured & design as approved, set, jointed and pointed in neat cement slurry as in floors etc; laid over & including 15mm thick screed in CM (1:6), complete all as specified and directed.
S &F Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc complete all as specified and directed.
Taking down chowkats or frame with shutter (without taking out shutter from the frame) not exceeding 1.50 sqm each as doors, windows & ventilators etc. and removal from site complete all as specified and directed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed.
S&F for factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tube for top and bottom rails MS frames shall be covered with heat moulded plain colour PVC `C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom raid on either side and as gap insert for top rail on either side andas gap insert for top rail and bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rials with suitable PVC sheet beading, and joined together with solvent cewment, suppling and fixing in the frame at site as per specification and drawing complete all as specified and directed.
S&F butt Hinges, 100 mm size, medium weight, cold rolled mild steel complete all as specified and directed
S&F Aluminium anodised barrel tower bolts, 150 mm long of extruded section complete all as specified and directed.
S&F Aluminium anodised handles, cast type anodised 150 mm long complete all as specified and directed.
Taking down chowkhats or frame exc 1.5 Sqm but n.exc 4 Sqm each with shutters (W/out taking off shutters from the frames) complete all as specified and directed.
S&F 150mm length floor door stopper of aluminium alloy body and tongue,anodised with hard drawan steel spring fixed in floor complete all as specified and directed.
Demolition of Cement concrete (unreinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed.
M&L for 25mm PCC (1:2:4) type B-1, 12.5mm thick as in floors finished even and fair for receiving kota stone in finished floor complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), terrazo dado/wall tiling and skirting. etc on brick or stone walls etc including racking out joints hacking for key and scrubbing removing serviceable tiles to store and rubbish off the premises etc complete all as specified and directed.
S&F non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm in floors, over and including 15mm thick screed in CM (1:6) set and jointed in neat cement slurry and pointed with white or coloured cement to match complete all as specified and directed.
S&F non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm in floors, over and including 10mm thick screed in CM (1:4) set and jointed in neat cement slurry and pointed with white or coloured cement to match as in skirting complete all as specified and directed.
Taking down Cement plaster including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15mm thick in patches in cement mortar 1:6 on other than fare face of brick work or concrete surfaces and finishing the surface even & smooth without using extra cement complete all as specified and directed.
Demolition of brick work of any type built in cement mortor in foul condition etc complete all as specified and directed.
M&L PCC (1:3:6) type C-2 (using 40mm graded agg) 75mm thick as in plinth protection finishing fair, even and smooth without using extra cement complete all as specified and directed.
M&L for Preparation of new plastered wall surfaces complete all as specified and applying the following: - (a) Applying wall care putty, in two coats on wall surfaces & smoothening the surfaces with sand papers/ mechanized sanding etc., (preparatory to paint as directed), complete all as specified. (b) Two coats of acrylic emulsion distemper by using airless spray/roller over and including a coat of acrylic emulsion internal primer, complete all as specified.
Complete removal of existing treatment on Old Internal wall surfaces of any desciption, preparation of surface by Mechanised sander having suction vaccum Bag using Smart periodical methodology, complete all as specified and applying the following :- (a) M&L for wall care putty in two layers on wall surface and smoothening the surface with sand papers / Mechanised sanding etc preparatory to paint as directed complete all as specified (b) M&L for two coat of Oil Bound distemper of approved tint over a coat of primer on old prepared surface by using Airless spray/Roller complete all as specified and directed. Note:- Contractor may use manual scraping tools for complete removal and surface preparation with prior approval of Engr-in-Charge in case of using of Mechancal equipement are not possible.
Complete removal of existing treatment including filling depression of scraped surface with wall putty two coats 1.5mm thick each coat on Old external wall surfaces of any description, preparation of surface by Mechanised sander having suction vaccum Bag using Smart periodical methodology , complete all as specified and applying the following:- (a) M&L for two coats of exterior acylic emulsion by using Airless spray/Roller over and including a coat of acrylic emulsion external primer complete all as specified and directed. Note:- Contractor may use manual scraping tools for complete removal and surface preparation with prior approval of Engr-in-Charge in case of using of Mechancal equipement are not possible.
M&L for Preparation of new plastered wall surfaces complete all as specified and applying the following: - (a) Applying wall care putty, in two coats on wall surfaces & smoothening the surfaces with sand papers/ mechanized sanding etc., (preparatory to paint as directed), complete all as specified and directed. (b) Two coats of exterior acrylic emulsion by using airless spray/roller over and including a coat of acrylic emulsion external primer, complete all as specified. NOTE FOR SERIAL ITEM 126 to 129 Contractor may use manual scrapping tools for complete removal and surface preparation with prior approval of EIC in case using of mechanical equipments are not possible.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as speified and directed.
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillet complete all as specified and directed.
S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
M & L 10 mm PVC insulation panels with EPS stuck to 1mm plain PVC sheet suitably placed in false ceiling grid made of Aluminium/G.I./M.S. As per specification and drawing`complete all as specified and directed.
S & F 5.50 mm thick sheet glass ordinary quality in squares exceeeding 0.50 Sqm in each pane complete all as specified and directed.
M& L Steel work in tubular trusses including special shaped washer etc complete using ERW or including butt welded tubes conforming to I.S-4923-1979 grade St -2240 including rolled mild steel as in joist channel ,angle,or tee ssections fixed independently , without connecting plates , etc (cut to ordinary legth ie within 20mm of tile length indicated of gde Fe 410-S ,complete all as specified amd directed
5 Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 5cm but n exc 10cm long complete all as specified and directed.
Dismantling of mild steel work of any description not otherwise provided for complete all as specified and directed.
S&F solid PVC wall lining consisting of 5 mm thick plain colour PVC sheet, but single side prelam PVC sheet inclusive of solvent cement and fixing at site on PVC frame as complete all as specified and directed.
S&F 5 mm thick PVC sheet fillet of width 35 mm for wall paneling inclusive of fixing on to wall to make PVC frame as per specification and drawing complete all as specified and directed.
S&F in repairs mild steel powder coated chromium plated curtain rod 20mm dia, including MS brackets fixed to wall with screws, PVC plug, fancy type knobs on both side of curtain rod complete all as specified and directed .
S & F powder coated Anodised aluminium frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
S & F powder coated Anodised aluminium door shutters,aluminium section weighing 0.55 kg/ including necessary joining cleats,glazing clips, ruber neopren packing,handles 2 Nos in each door, hinges,anodised aluminum snap beadingscrews etc. complete all as specified and directed.
S & F Door closer hydraulically regulated,designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between61 to 80 kg and fixed complete all as specified and directed.
S & F powder costed Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws, anodisedaluminium fittings such as peg stays150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1no.) complete all as specified and directed.
S &F Dark/light shade virified ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed in CM (1:6) set and jointed in neat cement slurry and pointed with white or coloured cement to match complete all as specified and directed.
S &F virified ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm in vertical surface etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over cement screed bed laid over 10mm screed base in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the walls complete all as specified and directed.
M & L granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, win?dow-cills, cooking plat?forms and like in cement mortar (1:4) including point?ing in white cement (1:2) us?ing marble dust with admix?ture of pigment to match with shade of granite complete all as specified and directed.
S & F Anodised aluminium snap grid size 605 mm x 605 mm frame work for false ceiling consisting of aluminium powder coated main runner (32.5 x 23.5 x 0.8 mm ), cross tee (26.50 x 23.05 x 0.8 mm ) and wall angle (20.30 x 20.30 x 0.8 mm ) repectively including material and labourfor hanger 2 mm dia G.I (Upto 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I flat 40 x 3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia 40 mm long including small fittings such as steel dash fasteners,butterfly clips etc as per site requirement complete all as specified and directed.
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 etc complete all as specified and directed.
M&L for first quality, scratch free, straight cut/joint free, vitrified pavers for external use, 9-10mm thick, of size 300mm x 300mm, in floors etc over & including 15mm thick cement mortar (1:4) screed, set and jointed with grey cement slurry & pointed with grout of matching shade of tiles, complete all as specified and directed.
INTERNAL ELECTRIFICATION
Taking down carefully existing copper/Aluminum point wiring (light,fan, socket or power) complete including fixture and fittings such as switches, bellpushes, ceiling roses, pendents, regulators, sockets, light fitting, callbells etc removiing materials to store for keeping in safe custody or for taking credit(credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc. to match existing complete allas specified and directed
Taking down unsv ceiling fan/exhaust fan, sealing cable end dismentaing blades and removing fan and blades to E/M store
M & L for Point wiring with multi-stranded copper conductor, single core, PVC insulated and unsheathed cable, including PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor to common earth and connected to earth dolly, GI terminal boxes, modular frame & cover plate (suitable for modular switch/sockets) comprising the following: -
One light point/fan point controlled by one switch & fan regulator for C/fan etc. with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
One Socket outlet three pin, 6 Amp, on the same board, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, all as specified.
One Socket outlet three pin, 6 Amp, independent, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
One socket outlet three pin, 5/15 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
One Bell/Buzzer point controlled by one push button with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC heavy duty concealed conduit all as specified.
Note for serial item No 92 to 97: 1. Switch(es) & socket(s) shall be measured & paid for separately under respective item of Schedule 'A'. 2. GI boxes shall be fixed flush in position with cement mortar (1:4) complete all as directed.
S&F Switch modular type single pole, one way, 6 Amp, one module, complete all as specified.
S&F Switch modular type single pole one way, 16 Amp, one module, complete all as specified.
S&F Bell push switch modular type single pole one way, 6 Amp, one module, complete all as specified.
S&F Socket outlet modular type, multipurpose, 2/3 pin, single pole one way, 6 Amp, two module, complete all as specified.
S&F Socket outlet modular type multipurpose 2/3 pin single pole one way 6/16 Amp, two module, complete all as specified.
S&F Fan regulator, modular type, 5 step, high speed, two module complete all as specified.
S&F Modular telephone socket one module complete.
S&F White cover plate with frame, 1 module.
S&F Metal flush box 1/2 module.
S&F Ceiling rose, 3 terminal PVC/polycarbonate, suitable for 230 V, AC, 50 Hz supply.
S&F call bell ding dong type AC 230 V complete.
S&F wall mounted extruded Aluminium/polycarbonate LED batten fixture T8(G13 holder) 1.2 m, including one LED retrofit tube 20(±10%) watt, 1.2 m T8 6500K,efficacy not less than 90 lumen/watt, extruded Aluminium/polycarbonate, PC diffusor and inbuilt driver complete complete including making connection complete all as specified and directed.
S&F wall mounted LED batten fitting 10 (±10%) watt, 6500K, 0.6m, efficacy not less than 90 lumen/watt , extruded Aluminium/polycarbonate, PC diffusor and inbuilt driver complete includign making connection complete all as specified and directed.
S&F LED downlighter/spot light fitting, recessed mounted, sqaure shaped of ceiling cut outφ140mm, 15watts efficacy not less than 90 lumen/watt, 6000K extruded Aluminium/polycarbonate, PC diffusor, module and inbuilt driver complete including making connection complete all as specified and directed.
S&F LED panel light fitting, recessed mounted, square shaped of size 595x595x65 sqmm, 36(±10%)watts efficacy not less than 90 lumen/watt, extruded Aluminium/polycarbonate, PC diffusor, module and inbuilt driver complete including making connection complete all as specified and directed.
S&F LED street light fitting 35 Watt 230V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrossion resistant complete with IP 65/66 protection including fixing with GI/MS bracket made out of suitable size of light grade tube upto 1.2 mtr length bent to shape with 02 sets of MS clamps made out of minimum 3 mm MS flat iron with suitable bolt and nuts complete with making connection complete allas specified and directed
S&F in repair post top lantern LED type 20 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistance complete with driver and lamp complete all as specified and directed
M&L in replacement Sub main wiring (with approved colour coding as per IS) with single core FRLSH PVC insulated flexible stranded copper conductor 1.1 KV grade (main cable: number of runs as indicated below along with single core FRLSH PVC insulated flexible stranded copper conductor 1.1 KV grade for earthing including concelaed suitable size PVC conduits medium grade and accessories, complete all as specified for the following :-
2 runs of 4 sq.mm main cable+ 1 run of 4 sqmm earth cable
2 runs of 6 sq.mm main cable+ 1 run of 6 sqmm earth cable
4 runs of 6 sq.mm main cable+ 1 run of 6 sqmm earth cable
NOTES: (i) Two run of main cable and one run of earth wire with medium grade concealed conduit and conduit accessories shall be measured as unit length and shall be deemed to be included in the quoted rate.
Supplying, laying, jointing & testing, in replacement underground XLPE insulated screen PVC bedded, GI steel strip or wire armoured heavy duty LT electric power cable with aluminium conductor, 1100Volts grade, cross sectional area 10 sqmm 2 core complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete all as specified and directed.
Removing excavated surplus soil to a distance n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L for Sand cushioning in trenches for cables including watering and consolidation complete all as specified and directed.
M&L for Bricks protection with old size Sub classs B bricks for protection of PVC/XLPE UG cable in trenches with axis perpendicular to cable, laid dry and flat, joining each other with gap between adjacent bricks not exceeding 10mm complete all as specified and directed
M&L for providing cement concrete in foundation, filling & mass concrete etc. Any work, type B1 1:2:4(20mm graded stone aggregate) including taking down old cement concrete complete all as specified and directed
Supply, laying & testing Tubes(In Repair), 'light grade' galvanised, 50mm bore with all fitting, unions, elbows etc and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
M & L for earthing with galvanized steel plate electrode 600 x 600 mm x 6 mm size directly burried in ground vertically to earth pit not less than 2.25 meter deep below normal ground level with top edge of the earth plate not less than 1.5 m below normal ground level surrounded with coal dust and common salt filling in alternative layers of 15 cm thick each connected to and including GI earth wire 4 mm dia by means of nuts, bolts, check nuts & washers etc connecting to earthing test point, main switch board and including 15 mm dia GI pipe light grade for protection of earth lead from earth plate to distribution board and 20 mm dia GI pipe medium grade connected with funnel having wire mess for watering purpose including necessary excavation and earth work, PCC (1:2:4) type B-1 (using stone aggregates) for earthing pit, 10mm thick cast iron cover with angle iron frame all as specified and shown in electrical plate No 3 of SSR Part-I and testing on completion including replacement of old unserviceable.
S&F in replacement sheet metal encloser double door 8 way SPN 240V ISI marked complete with neutral and earth link and bus bar complete made out of CRCA steel sheet Factory made including blanking plate for unused module complete all as specified and directed
-do- all as per item No 31 above but 04 way TPN 415 V complete all as specified and directed.
S&F in replacement single pole and neutral enclosure 240V with a two pin and earth plug and socket complete with one single pole MCB 20Amp complete all as specified and directed
S&F in repair MCB 6-32 Amp 240V SP 10 KA ‘C’ series complete all as specified and directed.
S&F in repair MCB 20-32 Amp 240V SPN 10 KA ‘C’ series complete all as specified and directed.
S&F in repair MCB 415V 40 to 100Amp TPN 10 KA ‘C’ series complete all as specified and directed.
Hanging only ceiling fan and connecting up incluidng provision of cable from ceiling rose or connector to fan. Note: Ceiling Fans will be provided by the E/M store free for fixing only.
Fixing only exhaust fan and connecting up including provision of cable from ceiling rose/connector to fan.Note: Exhaust fan will be provided by the E/M store free for fixing only.
S&F in repair rigid non-metallic PVC conduit external dia 25mm in size exclusive of boxes(junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. complete all as specified and directed.
S&F in repair PVC junction boxes(1 to 4 way) complete all as specified and directed.
Supplying and fixing in replacement PVC/PS/HDPE cable junction box of size 100mmx100mmx60mm complete with terminals 5 pole, IP 65 protected complete all as specified and directed
S&F in replacement sheet metal encloser single door 2 way SPN 240V ISI marked complete with neutral and earth link and bus bar complete made out of CRCA steel sheet Factory made including blanking plate for unused module complete all as specified and directed
Note:- Net contract sum shall be calculated after deduction of Sch of credit.
M/s Manav Builders
M/S KARTIK BUILDERS
SHARDA ENTERPRIES
Aman Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .