| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.3 LAccepted-AOC STATION ROAD POST RANGIYA DIST KAMRUP ASSAM PIN 781354 | KAMRUP | ASSAM | 781354 | L1 | Accepted-AOC RATES ARE FOUND REASONABLE AND THE FIRM BEING L1 BIDDER | |
| 2 | L2₹24.4 L+₹2.8 L (12.7%)Rejected-Finance RANGIYA STATION ROAD WARD NO 2 PO RANGIYA DIST KAMRUP ASSAM PIN 781365 | BAKSA | ASSAM | 781365 | L2 | Rejected-Finance BEING L2 BIDDER | |
| 3 | L3₹26.1 L+₹4.5 L (20.8%)Rejected-Finance | L3 | Rejected-Finance BEING L3 BIDDER | |
| 4 | L4₹26.9 L+₹5.3 L (24.3%)Rejected-Finance | L4 | Rejected-Finance BEING L4 BIDDER |
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
2 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE RANGIA
GE Rangia C/O 99 APO Rangia
SPL REPAIRS TO BLDG NO ET-23 OF HQ 21 MTN DIV AND OTHER SANCTIONED WORKS AT RANGIA MILITARY STATION UNDER GE RANGIA
2021_MES_414039_2
8443/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
RANGIA
AS PER NIT
8 documents required · 8 mandatory
₹500
GE RANGIA
₹56,000
Yes
11 Mar 2021
15 Feb 2021
4 Mar 2021
15 Feb 2021
2 Mar 2021
16 Feb 2021
60 days
Amount
Demolition of brick work built in any cement mortar complete all as specified and as directed by Engineer-in-charge.
M&L for brick work with sub-class `B' old size bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and as directed by Engineer-in-charge.
Demolition of reed, lathing, single or double, including battens and plaster or chicken wire lathing, complete all as specified and as directed by Engineer-in-charge.
Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc., complete all as specified and as directed by Engineer-in-charge.
M&L GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste, complete all as specified and as directed by engineer-in-charge.
M&L 15mm thick rendering in CM (1:6) on other than fair faces of brick work or concrete surfaces and finished the surface even & smooth without using extra cement complete all as per specified and as directed by Engineer-in-charge.
M&L 10mm thick rendering in CM (1:6) on other than fair faces of brick work or concrete surfaces and finished the surface even & smooth without using extra cement complete all as per specified and as directed by Engineer-in-charge.
M&L for 15 mm thick rendering on fair faces of brick work or one side of lathing in cement mortar (1:4) surface finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge.
Demolition of unreinforced cement concrete in ground floors and pavings nexc 15 cm thickness (below or above ground level) complete all as specified and as directed by Engineer-in-charge.
M&L 75 mm thick Cement concrete type C-2, 1:3:6 (using 40 mm graded stone aggregate) in footpath / hardstanding / pavings / plinth protections, finished even and smooth using extra cement complete all as specified and as directed by Engineer-in-charge.
Demolition of reinforced cement concrete of any description and in any position not otherwise specificied provided for, complete all as per specified and as directed by Engineer-in-charge.
S&F Mild steel flats etc., as in supports for stiffening of fencing, wall ties, hold fasts, wind ties, clamps and similar small articles etc. conforming to Fe-410, complete all as per specified and as directed by Engineer-in-charge.
M&L for mild steel TMT bars 6 to 8 mm dia. and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips, complete all as per specified and as directed by Engineer-in-charge.
M&L for mild steel TMT bars 5 mm to 10 mm dia., cut to length, bent to shape required, in stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips quality confirming to Fe-410-S 0r Fe-410-O, complete all as per specified and as directed by Engineer-in-charge.
M&L for for precast cement concrete (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) as in landings, cover slabs (for manholes etc.) shelves and similar articles with plain faces set in cement mortar 1:4 complete all as specified and as directed by Engineer-in-charge.
M&L for RCC type A-I (1:1.5:3) as in Lintel/chajjas complete all as per specified and as directed by Engineer-in-charge.
M&L Reinforced Cement Concrete Type A1 (1:1.5:3) nominal mix (using 20mm graded aggregate) in columns, pillars, posts and struts all as specified and directed by Engineer in Charge.
M&L for form work for side of pillars, posts, columns & similar works vertical or batter complete all as specified and as directed by Engineer-in-charge.
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilivers, shelves including upports, overhangs, etc. also splays between floors and beams, etc. Fair finished surface of concrete flat complete all as per specified and as directed by Engineer-in-charge.
Dismantling Unframed timber scantlings 40 Sqcm and over in section and in any position, complete all as specified and as directed by Engineer-in-charge.
M&L 2nd class hard wood in scantling wrought timber unframed and fixed, complete all as specified and as directed by Engineer-in-charge.
Dismantling of unframed fillets, rails, posts, rafters, purlins etc., under 40 Sqcm in section, complete all as specified and as directed by Engineer-in-charge.
M&L second class hard wood plain fillets, square or rectangular or triangular in section, clean sawn, secured with screws or brads having sectional area exceeding 13 sqcm but not exceeding 25 sqcm complete all as specified and as directed by Engineer-in-charge.
M&L second class hard wood plain fillets, square or rectangular or triangular in section, clean sawn, secured with nails or brads having sectional area exceeding 6 sqcm but not exceeding 13 sqcm complete all as specified and as directed by Engineer-in-charge.
Dismantling boarding, any description fixed in any position with nails, complete all as specified and as directed by Engineer-in-charge.
M&L 50 mm thick 2nd class hard wood boarding clean sawn with butt joints fixed with nails in any situation (except flooring and skirting), complete all as specified and as directed by Engineer-in-charge.
M&L for 2nd class hardwood 20mm (Planed both side) boarding with butt joints fixed with nails in any situation (except flooring and skirting), complete all as per specified and as directed by Engineer-in-charge.
Dismantling wall and ceiling boards (fibre, pulp, insulation,etc) or insulation board/Slabs/blankets of any thickness including cover fillets, complete all as specified and as directed by Engineer-in-charge.
S&F Gl frame work for seamless false ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre and grid of GI frame will be 60 x 60 cm to recieve E-board ceiling complete all as specified and as directed by Engineer-in-charge.
M&L for 4mm thick Non Asbestos fiber Cement Designer E- board ceiling of size (595x595)mm fixed in GI frame work (snapgrid) of standard section as per manufacturers instructions with the 3mm thick GI suspender in ceiling, complete all as per specified and as directed by Engineer-in-charge.
Dismantling Asbestos Cement (Corrugated, Semi corrugated etc.) sheets in roof coverings, complete all as specified and as directed by Engineer-in-charge.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated or semi-corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws or J hooks, complete all as specified and as directed by Engineer-in-charge.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws or J hooks, complete all as specified and as directed by Engineer-in-charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as per specified and as directed by Engineer-in-charge.
S&F coloured non-skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shades of tiles over 15 mm thick screed bed or bedding layers in CM 1:4 complete all as per specified and as directed by Engineer-in-charge.
S&F for coloured glazed ceramic tiles (300x200) x 6 or7mm thick, in dado/skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and as directed by Engineer-in-charge.
M&L Machine cut Kota stone slab 20-25mm thick over 15 mm thick CM 1:6 Screed bed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as per specified and as directed by Engineer-in-charge.
M&L Machine cut Kota stone slab 20-25mm thick over 10 mm thick CM 1:4 Screed bed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as per specified and as directed by Engineer-in-charge.
M&L 25 mm thick PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) as in floor, finished even and smooth using extra cement complete all as specified and as directed by Engineer-in-charge.
Taking down chowkat or frame not exceeding 1.5 Sqm each (without taking off shutter from the frame), complete all as specified and as directed by Engineer-in-charge.
Taking down chowkat or frame exceeding 1.5 Sqm but not exceeding 4 Sqm each (without taking off shutter from the frame), complete all as specified and as directed by Engineer-in-charge.
Taking down shutters of any description exceeding 1 Sqm but not exceeding 2 Sqm each, complete all as per specified and as directed by Engineer-in-charge.
S&F Solid PVC Door Frame of size 50mm x 95mm made out of 5mm single side prelam PVC sheet used instead of plain colour PVC sheet & edges will be painted to match with prelam sheet, reinforced with M.S Square tube complete all as per specified and as directed by Engineer-in-charge.
S&F Factory Made Solid PVC moulded Door Shutter (with wood free EPS) 28 to 30mm thick (style) with 2,4, or 6 raised panel design with 2mm thick moulded prelam sheet on the front face and 2mm prelam PVC sheet on back face complete as per manufacturer's instruction and all as per specified and as directed by Engineer-in-charge.
S&F Factory made solid wire gauzed pvc door shutter 30mm thick (style) consisting of frame made out of M.S.tubes for top & bottom rails.M.S.frame shall be covered with heat moulded prelam PVC "C" channel having a prelam PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and prelam PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panells will be wire gaused in lieu of single side prelam PVC sheet panel. The wire gause shall be wrapped on an additional square 8 mm MS solid tube and this tube shall be welded to MS tubes. The wire gause shall be stretched to tighten firmly. And jointed to gether with solvent cement, suppling & fixing in the frame at site complete all as per specified and as directed by Engineer-in-charge.
S&F 30 mm thick flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides, complete all as per specified and as directed by Engineer-in-charge.
M&L for steel windows with side hung shuttres including box type hinges with steel handle and steel peg stay ,complete without glazing bars, dovetailed or welded, complete all as per specified and as directed by Engineer-in-charge.
M&L for steel windows with side hung shuttres including projecting type hinges with steel handle and steel peg stay ,complete with glazing bars,dovetailed or welded, complete all as per specified and as directed by Engineer-in-charge.
M&L for Mild steel work such as grills, grating, etc., hand rails, wind ties, posts and struts in fencing screwed or welded to shape as directed, including all necessary drilling, bolting or riveting etc., and similar work confirming to Fe 410 - O or Fe 310 - O, complete all as per specified and as directed by Engineer-in-charge.
S&F 100 mm long medium weight, cold rolled mild steel butt hinges, complete all as specified and as directed by Engineer-in-charge.
S&F 125 mm long aluminium anodised barrel tower bolts of extruded section, complete all as specified and as directed by Engineer-in-charge.
S & F 125 mm long Extruded Aluminium alloy handles, fabricated type, anodised, complete all as per specified and as directed by Engineer-in-charge
S&F galvanised mild steel wire cloth, 0.56 mm dia of wire and average width of aperture 1.18 mm and fixed with galvanised wire staples, complete all as specified and as directed by Engineer-in-charge.
S&F 3 mm thick sheet glass, ordinary quality in squares not exceeding 0.5 Sqm in each pane fixed with cut & mitred beads, complete all as specified and as directed by Engineer-in-charge.
Taking up or down 15 mm bore steel tubing and connections, complete all as per specified and as directed by Engineer-in-charge.
Taking up or down 20 mm bore steel tubing and connections, complete all as per specified and as directed by Engineer-in-charge.
S&F 15 mm galvanised steel tubes, medium grade with all fittings laid in trenches including cleaning of pipes as required and testing complete all as per specified and as directed by Engineer-in-charge.
S&F 20 mm galvanised steel tubes, medium grade with all fittings laid in trenches including cleaning of pipes as required and testing complete all as per specified and as directed by Engineer-in-charge.
S&F in repair 15 mm bore CP bib taps with wall flange, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed by Engineer-in-charge.
S&F in repair 15mm dia bore pillar tap fancy type cast copper alloy with capston heads chroumium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly-nuts, screwed for iron pipe complete all as per specified and as directed by Engineer-in-charge.
S & F in repair vitreous china wall hung wash basin white, flat back, size 550 x 400 mm size (flat back or angle back type) excluding taps, waste, but including cutting for and pinning ends of brackets with pedestal or erecting stand, complete all as per specified and as directed by Engineer-in-charge.
M&L for preparation of new or previously untreated wood or wood based surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of old or previously untreated surfaces of wood and wood based materials of any description, not otherwise described over 10 cm width or girth and applying one coat of Synthetic enamel paint over a coat of pink primer , complete all as per specified and as directed by Engineer-in-charge.
M&L for preparation of old or previously untreated surfaces of wood and wood based materials of any description, not otherwise described not exceeding 10 cm width or girth and applying one coat of Synthetic enamel paint over a coat of pink primer , complete all as per specified and as directed by Engineer-in-charge.
M&L for preparation of new or previously untreated steel or iron surface of any description and applying two coats of synthetic enamel paint over a coat of red oxide, primer over 10cm width or girth complete all as specified and as directed by Engineer-in-charge.
M&L preparation of old painted steel and iron surfaces of any description over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint over a coat of pink primer, complete all as per specified and as directed by Engineer-in-charge.
M&L for preparing newly plastered surfaces of walls and applying three coats of white wash complete all as specified and as directed by Engineer-in-charge.
M&L for preparing old decorated plaster surfaces etc and applying one coat of white wash on walls, complete all as per specified and as directed by Engineer-in-charge.
M&L for preparing new plastered surfaces and applying two coats of cement based paint on walls over a coat of alkali resistant primer, complete all as per specified and as directed by Engineer-in-charge.
M&L for preparing old plastered surfaces and applying two coats of cement based paint on walls over a coat of alkali resistant primer complete removal of existing treatment, complete all as per specified and as directed by Engineer-in-charge
M&L for PCC 1:3:6 type C-2 (40mm graded stone aggregate) as in surface channels and drains including necessary form work complete all as per specified and as directed by Engineer-in-charge.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends complete all as specified and as directed by Engineer-in-charge.
M&L for ATT at points of contract of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150 mm centre to centre and sealing the same complete all as per specified and as directed by Engineer-in-charge.
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge.
M&L for PCC (1:4:8) type D2 ( using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as per specified and as directed by Engineer-in-charge.
M&L for RCC type A-I (1:1.5:3) as in foundation beams; plinth beams; bases for columns, etc. complete all as per specified and as directed by Engineer-in-charge.
M&L for RCC type A-I (1:1.5:3) as in slabs supported on walls, beams and, landings, deck slabs etc. complete all as per specified and as directed by Engineer-in-charge.
M&L for Formwork to sides of concrete foundation, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter fair finished surface of concrete flat complete all as per specified and as directed by Engineer-in-charge.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), complete all as per specified and as directed by Engineer-in-charge.
M&L for Formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide. (Where RCC/PCC band in walls, spanning and opening, the formwork soffit only shall be paid for under item 07010) Rough finished surface of concrete complete all as per specified and as directed by Engineer-in-charge.
M&L for mild steel TMT bars 10 mm dia. and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips, complete all as per specified and as directed by Engineer-in-charge.
M&L for brick work with sub class 'B' bricks, straight or curved on plan exc. 6m mean radius in cement mortar 1:6, complete all as per specified and as directed by Engineer-in-charge.
M&L 10mm thick rendering in CM (1:6) on fair faces of brick work or concrete surfaces and finished the surface even & smooth without using extra cement complete all as per specified and as directed by Engineer-in-charge
M&L 5mm thick ceiling plaster in CM (1:3) finished even and smooth without using extra cement complete all as per specified and as directed by Engineer-in-charge.
M&L for sand filling under floors or in foundations for fixing of interlocking tiles spreading and levelling in layers including watering as required, complete all as per specified and as directed by Engineer-in-charge.
M&L for damp proof course to horizontal surfaces including necessary formwork in cement concrete (1:2:4) mix type B-0, 40mm thick complete all as per specified and as directed by Engineer-in-charge.
Supply and laying polythene film, 150 micron thick laid on a coat of bitumen primer @ 0.30 to 0.50 kg per sqm complete all as per specified and as directed by Engineer-in-charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as per specified and as directed by Engineer-in-charge.
Removing excavated material not exc. 50 m & depositing where directed at a level not exc. 1.5 m above starting point complete all as per specified and as directed by Engineer-in-charge.
supply only Integral waterproofing compound complete all as per specified and as directed by Engineer-in-charge.
M&L for hardcore of guage not exc. 63mm deposited, spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surface of broken stone or boulders, complete all as per specified and as directed by Engineer-in-charge.
M&L for 15 mm thick screed bed or bedding layer of cement mortar (1:6) fixing of tiles in floor finishes, complete all as specified and as directed by Engineer-in-charge.
M&L rendering 10mm thick in CM 1:4 on brick or concrete surfaces for fixing of tiles in wall complete all as per specified and as directed by Engineer-in-charge.
M&L for Machine cut kota stone slab flooring 20 - 25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete all as specified and as directed by Engineer-in-charge.
M&L for Machine cut kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as per specified and as directed by Engineer-in-charge.
M&L for forming Construction joint 30mm deep x 10mm wide filled with sealing compound Grade 'A', complete all as per specified and as directed by Engineer-in-charge.
M&L applying two coats of distemper over a coat of 3 mm thick a layer of wall care putty on walls including preparation of surface complete all as per specified and as directed by Engineer-in-charge.
M&L for PCC 1:3:6 type C-1 as in bed block of hold fast using 20mm graded stone aggregate steps etc., complete all as per specified and as directed by Engineer-in-charg
S&F pressed steel frames size 125 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed complete all as per specified and as directed by Engineer-in-charge.
S&F 35 mm thick flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides, complete all as per specified and as directed by Engineer-in-charge.
S&F aluminium alloy 300 mm anodised sliding door bolts with hasp, staple (bolt type) & fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast - aluminium alloy, complete all as specified and as directed by Engineer-in-charge.
S&F 200 mm long Aluminium, anodised, barrel tower bolts of extruded section, complete all as per specified and as directed by Engineer-in-charge.
S&F 150 mm long extruded Aluminium alloy handles, fabricated type, anodised, complete all as per specified and as directed by Engineer-in-charge.
M&L for preparation of concrete roof surface appyling roof treatment as under:- (a) applying bituminous primer @ 0.30 liter per sqm of surface (b) Applying one coat of 85/25 grade hot bitumen @ 1.20 kg/sqm of surface (c) Laying of APP modified water proofing membrance with non-woven polyster reinforcement on hot applied bitumen with 100mm over lap at joints by torching on the transverse direction and 75 mm on longitudinal direction all as per manufacture's instructions (d) Applying one coat of bitumineous aluminium paint @ 0.10 litre/sqm complete all as per specified and as directed by Engineer-in-charge.
M&L for 15 mm thick screed bed or bedding layer of cement mortar (1:3) mixing with water proofing compound @3% by weight of cement consumed and as per manufactures instruction and surface finished even and smooth over RCC roof slab without using extra cement complete all as specified and as directed by Engineer-in-charge. Note - WPC shall be measured and paid saparately.
M&L for brick work with sub class 'B' bricks, straight or curved on plan exc. 6m mean radius in cement mortar 1:4, complete all as per specified and as directed by Engineer-in-charge.
M&L for PCC 1:2:4 type B-1 as in coping/benching etc., complete all as per specified and as directed by Engineer-in-charg
M&L for Machine pressed precast concrete interlocking paver block gloosy fineshed laid over sand layer of 40mm thick of any shape and size confirming to IS 15658 of 60 mm thickness of M-35 grade, complete all as per specified and as directed by Engineer-in-charge. (NOTE- sand filing layer will be measured and paid seperately)
Taking down carefully aluminum/copper point wiring (light, fan, socket or power) complete incl fittings and fixtures such as switches, sockets, light fittings, ceiling rose, pendants, lamp holders, shade conical, regulators etc and separating serviceable fittings for reuse in the same work and removing unserviceable fittings and fixtures with wiring cable, battens, wooden boards etc from site and making good disturbed surfaces of walls, floors, ceiling etc all complete all as specified and directed complete all as per specified and as directed by Engineer-in-charge.
Taking down carefully unserviceable main switches and DB’s including wooden boards and removing from site including making good disturbed surfaces of walls complete all as per specified and as directed by Engineer-in-charge.
Taking down ceiling/exhaust fan of any size by disconnecting Electric Connection, dismantling Blades, and removing exhaust Fan to MES STORE YARD OF AGE E/M RANGIA complete all as specified and as directed by Engineer-in-charge.
Material and labour for point wiring complete with 1.5 sqmm PVC insulated unsheathed 1100 volts grade cable stranded copper conductor single core in casing caping of 20/25 mm size complete with PVC terminal box for fitting mounting switch/ sockets regulators etc. with laminated sheet 3 mm thick cover and with 1.5 sqmm PVC insulated copper conductor earth wire and connected to earth dolly for one light point controlled by one switch complete all as specified and as directed by Engineer-in-charge.
All as per Serial item No. 113 above but for one ceiling/exhust fan controlled by one switch complete all as specified and as directed by Engineer-in-charge
All as per Serial item No. 113 above but for one 3 pin socket outlet 5 AMPs on same board complete all as specified and as directed by Engineer-in-charge
All as per serial item no. 113 above but for 3 pin 15 AMPs socket outlet on independent boards. with 4 sqmm (nominal area) cable with 4.00 sq mm size copper earth continuity conductor of green colour, complete all as specified and as directed by Engineer-in-charge
All as per Serial item No. 113 above but for one 3 pin socket outlet 5 AMPs on independent boards complete all as specified and as directed by Engineer-in-charge
Supply and fix ceiling rose surface backelite three terminals, PVC/polycarbonate, insulated body, complete all as specified and as directed by Engineer-in-charge.
Supply and fix switch piano flush type, 6 Amps 240 volts single pole one way, complete all as specified and as directed by Engineer-in-charge.
Supply and fix ceiling fan regulator electronic type, rotary step, Socket type 240 Volt, complete all as specified and as directed by Engineer-in-charge.
S&F socket outlet 2 in 1, 230 volts, flush type, 5 pin 5 Amp complete all as specified and as directed by Engineer-in-charge
Supply and fix switch socket combination 05/16 Amp 6 pin flush type, complete all as specified and as directed by Engineer-in-charge.
Supply and fix lamp holder, PVC/Polycarbonate type complete all as specified and as directed by Engineer-in-charge.
Supply and fix sheet metal enclosure powder painted for MCB SPN 12 way double door 230 volt DB with din rail and suitable bus bar complete all as specified and as directed by Engineer-in-charge.
Supply and fix MCB SPN upto 32 Amp 240 volt, complete all as specified and as directed by Engineer-in-charge.
Supply and fix MCB SP 240 Volts 6 to 32 Amps breaking capacity 10 KA rating complete all as specified and as directed by Engineer-in-charge.
Supply and fix LED batten 4ft long, Ultra bright, glass shell, glare free, wide angle, suitable for 20W LED tube, single side connection, complete all as specified and as directed by Engineer-in-charge.
Supply and fix LED tube 20W with single side connection complete all as specified and as directed by Engineer-in-charge.
S&F building Security light fittings 20 Watt LED New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP openning seperate driver compartment with IP65 protection and impact resistance of IK07 and including connection up with twine core twisted flexible copper conductor cable with 1.5 M long suitable size, complete all as specified and as directed by Engineer-in-charge.
S&F street light bracket made out of GI tubing 25 mm bore medium grade 1.20 Mtr long bend to required shape as in bracket for street light fittings fixed with two pair or MS flat iron 40mm x 5mm size and 30cm long clamp of required shape with bolts nuts and washers suitable for steel tubular pole including painting of mild steel flat iron surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-charge.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (light grade) and chamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 5 of SSR PT 1, 1991 with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switches, DBs) including taking down old unserviceable one, complete all as specified & testing on completion. NOTE:- (I) item includes the cost of 7.5 mtr length GI pipe for protection for GI earth wire. (ii) item rates includes the cost of 7.5 mtr earth lead GI earth wire. (iii) PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe,bends,elbow etc shall be deemed included in the unit rate.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (light grade) and chamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 5 of SSR PT 1, 1991 with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switches, DBs) complete all as specified & testing on completion. NOTE:- (I) item includes the cost of 7.5 mtr length GI pipe for protection for GI earth wire. (ii) item rates includes the cost of 7.5 mtr earth lead GI earth wire. (iii) PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe,bends,elbow etc shall be deemed included in the unit rate.
S&F in repair PVC terminal boxes 18 module for mounting mounting of DBs with 2 mm thick plastic laminated sheet cover complete all as specified and as directed by Engineer-in-charge.
S&F PVC terminal boxes 18 module for mounting mounting of DBs with 2 mm thick plastic laminated sheet cover complete all as specified and as directed by Engineer-in-charge.
S&F in repair down rod 12mm dia made out of mild steel 900mm long complete all as per specified and as directed by Engineer-in-charge.
Hanging only Ceiling/exhust fan of any sweep to its original position, painting of ceiling/exhaust fan complete in situ with one coat of synthetic enamel paint by spraying including filling cavities with filler after cleaning of all dust etc including necessary electric connection from Ceiling Rose/Connector to Fan with new flexible cord copper three core of size 40/.00076, complete all as specified and as directed by Engineer-in-charge.
S&F in repair House service bracket (Hook type) complete with 40 mm dia GI pipe 3.00 m long, medium grade, two Nos. of 90 degree bends, M.S hook and stay or guy including two coats of aluminium paint over a coat of red oxide primer complete all as per specified and as directed by Engineer-in-charge.
S&F 1100 volts grade heavy duty 16 sqmm cable PVC insulated stranded aluminum conductor served with inner sheathing of PVC tape and overall PVC sheathed for service connection suspended by insulating hangers not more than 1mtr apart including 4 mm dia suspension wire one twin core cable flat or circular including taking down old unserciveable cable, complete all as specified and as directed by Engineer-in-charge.
Supply and fix LED bulb, 7watt, Retrofit type, complete all as specified and as directed by Engineer-in-charge.
Supply and fix sheet metal enclosure powder painted for MCB SPN 8 way double door DB with din rail and suitable bus bar complete all as specified and as directed by Engineer-in-charge.
S&F street light bracket made out of GI tubing 32 mm bore medium grade 1.50 Mtr long bend to required shape as in bracket for street light fittings fixed with two pair or MS flat iron 50mm x 6mm size and 30cm long clamp of required shape with bolts nuts and washers suitable for steel tubular pole including painting of mild steel flat iron surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-charge.
S&F ceiling fan 1200 mm sweep, energy saving, five star rating, 3 each blade with internal pre wired, ISI marked of approvel colour complete all as specified and as directed by Engineer-in-charge.
Supplying & fixing, connecting, commisioning and testing LT cable XLPE insulated power cables ( heavy duty) with stranded aluminum conductor, 1100Volt grade of size 16 Sqmm 2 Core including testing, complete all as specified and as directed by Engineer-in-charge.
Supply & Laying Sub-Class B Bricks, well burnt, laid breadth wise along the length of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and as directed by Engineer-in-charge.
'M&L for sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreding thickness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed by Engineer-in-charge.
Supply laying GI pipe 40 mm bore light grade for protection of UG cable with necessary clamps with bolts etc, complete all as specified and as directed by Engineer-in-charge. Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ.
M/s SHARMA BUILDERS & ENGINEERS
M/s Adil Construction
RAJKAMAL ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .