Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹33,090
Closing Date
20 Mar 2025, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief Executive Officer
Chief Executive Officer, District Panchayat, Daman
Reparing of Existing Toilet block at Ringanwada,Damanwada and Ambawadi Primary School and Upper Primary School District Daman.
2025_DAMAN_4077_1
26/2024-25
Open Tender
Civil Works
Works
60 days
Daman
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Chief Executive Officer
₹33,090
22 Apr 2025
1 Mar 2025
20 Mar 2025
1 Mar 2025
20 Mar 2025
1 Mar 2025
Items :
Demolition and disposal of unserviceable materials with all lead and lift.(i) RCC concrete.
P & L 24" x 24" vitrified 8 mm thick tile flooring over 20 mm(average) base of cement mortar 1:6 ( 1 cement: 6 coarse sand) onnew surface or fixing on existing flooring by adhesive material including dismentaling of existing flooring and jointed with colorcement slurry including finised with flush pointing & cleaning the surface etc. complete for antiskit
Providing Material, Labour and equipments for Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thickjointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : including Khurra & Gola work With average thickness of 120 mm and minimum thickness at khurra as 65 mm, etc complete as directed by engineer-incharge.
Providing laying and jointing in true line and level 15mm dia.U.P.V.C. Pipe ( SCH- 40) for cold water including fittings asapproved by Engineer In Charge. Pipe shall be fixed on the wall with the help of clamp at every two metre C/C or shall be concealed as directed including necessary fittings etc. including testing of pipe and joints and fixing the same with adhesive solvent, including cost of all materials.
Providing laying and jointing in true line and level 25mm dia.U.P.V.C. Pipe ( SCH- 40) for cold water including fittings asapproved by Engineer In Charge. Pipe shall be fixed on the wallwith the help of clamp at every two metre C/C or shall be concealed as directed including necessary fittings etc. including testing of pipeand joints and fixing the same with adhesive solvent, including cost of all materials.
Providing, laying and jointing in true line and level 110 diametreU.P.V.C (Type B) conforming to IS 13592-1992 with one end plainand other end socketed with rubber ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system pipe line,pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 110 mmdiametre x 149 mm length x 145 mm heigh at every 2000 mm center to center or shall be concealed in walls as directed ncludingnecessary fittings such as bends, shoes etc. including testing ofpipes and joints and jointed with adhesive solvent cement including cost of all materials.
PRADIMAL FAKIRBHAI PATEL (BID ID -8990)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .