| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹23.8 LAccepted-AOC NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | 1 | Accepted-AOC Being lowest and reasonable rates | |
| 2 | 2₹33.8 L+₹10.1 L (42.5%)Rejected-Finance | 2 | Rejected-Finance Not being a lowest tenderer | |
| 3 | 3₹38.0 L+₹14.2 L (59.9%)Rejected-Finance WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | 3 | Rejected-Finance Not being a lowest tenderer |
Tender Value
₹55.0 L
EMD Value
₹1.3 L
Closing Date
28 Nov 2022, 6:00 pmClosed
HQ CWE (U) DELHI CANTT-10
HQ CWE (U) DELHI CANTT-10
REPAIR AND MAINTENANCE OF HT SWITCHGEAR, POWER TRANSFORMER, YARD MAINT WITH CONNECTED ITEMS AT 33/11 KV KIRBY GRID OF HT 33/11 KV KIRBY GRID AND MAINTENANCE OF LT PANELS/FEEDER PILLARS AT ME LINE, AOC SUB STN, DENTAL OFFICERS MESS, OVAL SUB STN, CICP
2022_MES_558537_1
CWE(U)/D-19/2022-23
Open Tender
Civil Works
Item Rate
180 days
HQ CWE (U) DELHI CANTT-10
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
Yes
GE(U) ELECTRIC SUPPLY, DELHI CANTT -110010
₹1.3 L
Yes
16 Dec 2022
18 Oct 2022
30 Nov 2022
18 Oct 2022
28 Nov 2022
16 Nov 2022
Amount
Supply installation & commissioning in replacement of 24V/40A Float Cum Boost Battery Charger unit including battery bank comprising 02 Nos of 12 Volts-100 AH sealed maintenance free battery. The CCCV battery charger consisting of copper wound, air cooled transformer, 01 Set single phase full wave bridge rectifier consisting of diodes and SCRs, liberally rated mounted on heat sink and complete with resistor/condenser network for surge supperssion . During auto float mode automatic changeover shall take place from float mode to boost mode and vice versa, 01 Set of solid state constant potential controller to stabilize the DC output voltage of the float cum boost charger, 01 No electronic controller , DC digital ammeter, DC digital voltmeter, Potentiometer, DC, MCB for reverse battery protection . The charger should have alarm annunciation with visual and audible alarm with manual reset facility for fuse fail alarm. Float cum boost battery charger and DC distribution board shall be housed in powder coated sheet steel cubicle with panels of 1.6mm thickness , louvers for ventilation, gland plate will be provided for cable entry from bottom. The battery charger shall be divided into two compartments. The upper compartment shall house the battery charger & DCDB with all necessary controls. The lower compartment shall be suitable for housing the batteries.
Tech specification shall be as under:- (a) Input working voltage-180 -270 Volts (b) Nominal Input Voltage - 230 V , AC , 50 Hz,1 (c) On load input power factor - > 0.8 (d) On load unit watt efficiencies-> 80% (e) No load losses of complete charge-< 10% (f) Ripple contents on the load (RMS)= 1% to 5% (g) Over load - 110% for 30 minutes and will give visual indication for over load condition. (h) Boost charging - 2.4 V/Cell . (j) Float charging -2.15 V/Cell (k) Float cum boost charging-Automatically changes from one state to another state as per battery condition and will give the visual indication for either float or boost based on charging mode. (l) Reverse polarity -No damage will caused . A visual indication for reverse polarity will appear with an audio alarm. (m) Short circuit-MCB protecton provided.
M&L for ON load Centrifuging and dehydration including filteration and cleaning of transformer oil by dehydration machine of 33 KV transformer at site and topping up deficient transformer oil including testing of samples before and after dehydration and filteration complete all as specified and directed. Note :- Deficient quantity of Transformer oil required for top up shall be measured and paid separately under item No 3 here-in -after as supply only.
Supply only transformer oil of approved quality as per IS having dielectric strength of 45-60 KV in 2.5mm gap for filling in OLTC & for topping up in transformer as required and directed
Material and labour for servicing /testing of line circuit breaker, control panel including outdoor CT, PT and relays in control panel of outdoor SF 6 Gas Circuit Breaker of capacity 1250/800 Amps and rating 36 KV complete as details mentioned as under:- (a) Details of servicing of breaker :- (i) Checking of Closing/Tripping coil assembly (ii) Adjustment of mechanism if required. (iii) Clean the circuit breaker to remove dust and dirt. (iv) Apply a small amount of oil to rotary sections, sliding surfaces, pins, coupling section, etc.use grease for the operating shaft and bearings, and machine oil for other parts. (v) Check for rust,wear/tear. (vi) Checking of spring charge mechanism (vii) Visual check for any deformation. (viii) Check for loosened bolts and nuts, broken spring washers and snap pins etc. (ix) Check for loosened connections, damaged lead wires. (x) Checking of control circuit & tighten the connections if any. (xi) Check close & trip coil. (xii) Replacement of Dashpot/shock absorbers. (xiii) Replacement of carbon brush of spring charging motor. (xiv) Cleaning of porcelain bushing (xv) Checking of limit switch.
(b) The following test shall be carried out:- (i) Primary Injection Test of outdoor CT / PT. (ii) Closing & Opening Timing Test for all three poles. (iii) IR Test with megger in open and closed condition. (iv) Contact resistance test for all three poles (v) Closing coil resistance. (vi) Tripping coil resistance. (c) Testing of following relays of control panel with Secondary Injection Kit ,checking and programming of relay :- (i) Over current and earth fault relay. (ii) Line diffrential relay. (d) Testing of followig Aux relay:- (i) DC Supply supervision relay. (ii) Trip Circuit suprvision relay. (ii) SF 6 gas pressure low. (iii) PT Fuse failure relay. (iv) Master trip relay. (v) Under voltage relay. (vi) Over voltage relay
Material and labour for servicing /testing of transformer circuit breaker, control panel including outdoor CT, PT and relays in control panel of outdoor SF 6 Gas Circuit Breaker of capacity 1250/800 Amps and rating 36 KV grocomplete as details mentioned as under:- (a) Details of servicing of breaker :- (i) Checking of Closing/Tripping coil assembly. (ii) Adjustment of mechanism if required. (iii) Clean the circuit breaker to remove dust and dirt. (iv) Apply a small amount of oil to rotary sections,slidingsurfaces, pins, coupling section, etc.use grease for the operating shaft and bearings, and machine oil for other parts. (v) Check for rust and wear/tear. (vi) Checking of spring charge mechanism. (vii) Visual check for rust and deformation. (viii) Check for loosened bolts and nuts, broken spring washers and snap pins etc. (ix) Check for loosened connections, rust, damaged lead wires. (x) Checking of control circuit & tighten the connections if any. (xi) Check close & triping coil. (xii) Replacement of Dashpot/shock absorbers . (xiii) Replacement of carbon brush of spring charging motor. (xiv) Cleaning of porcelain bushing (xv) Checking of limit switch etc.
(b) The following test shall be carried out:- (i) Primary Injection Test of outdoor CT / PT. (ii) Closing & Opening Timing Test for all three poles. (iii) IR Test with megger in open and closed condition. (iv) Contact resistance test for all three poles (v) Closing coil resistance. (vi) Tripping coil resistance. (c) Testing of following relays of control panel with Secondary Injection Kit, checking and programming of relay :- (i) Over current and earth fault Relay. (ii) Transformer diffrential relay. (d) Testing of followig Aux relay (i) DC supply supervision relay. (ii) CB SF 6 gas pressure low. (iii) Master trip relay. (iv) Main Buchholz trip. (v) Buchholz OLTC Trip. (vi) SPR & PRV trip. (vii) Winding temp high trip. (viii) Oil temp high trip. (ix) Main Buchholz alarm. (x) Winding temp High alarm. (xi) Low Oil level alarm. (xii) Oil temp high alarm
Material and labour for servicing /testing of breaker/control panel including CT, PT and relays in control panel of VCB of capacity 1250 /800/630 Amps and rating 11 KV complete as details mentioned as under:- (a) Details of servicing of breaker :- (i) Adjustment of mechanism if required. (ii) Clean the circuit breaker to remove dust and dirt. The envelope of the vacuum interrupter and insulating materials shall be wiped with a clean cloth. (iii) Apply a small amount of oil to rotary sections, sliding surfaces, pins, coupling section, etc.use grease for the operating shaft and bearings, and machine oil for other parts. (iv) Check for rust and wear. (v) Check Spring Tension and pitting of the Cluster Contacts. (vi) Visual check for rust and deformation. (vii) Check for loosened bolts and nuts, broken spring washers and snap pins etc. (viii) Check for loosened connections, rust, damaged lead wires. (ix) Check whether the contacts are damaged by arcing. (x) Checking of control circuit & tighten the connections if any. (xi) Check close & trip coil.
(xii) Checking of Jaw Contacts Conditions and repair/adjust. (xiii) Replace the jaw contacts,If required. (xiv) Applying of epoxy Paint for Support /Spouch insulator,CTs,PTs, and epoxy body at inside of VCB for improvment of resistance value. (xv) Replacement of Dashpot/shock absorbers . (xvi) Replacement of carbon brush of spring charging motor. (b) The following test shall be carried out:- (i) Primary Injection Test of CT / PT. (ii) Closing & Opening Timing Test for all three poles. (iii) IR Test with megger in open and closed condition. (iv) Contact resistance test for all three poles. (v) Closing coil resistance. (vi) Tripping coil resistance. (c) Testing of following relays of control panel with Secondary Injection Kit ,checking and programming of relay :- (i) Over current and earth fault relay. (d) Testing of followig Aux relay. (i) DC Supply supervision relay. (ii) Master trip relay.
Material and labour for topping up of / filling of SF-6 gas to achieve required gas pressure in 36 KV SF6 breaker and testing complete all as specified and as directed.
S&F in replacement of closing coil assembly 50 volts DC of existing make ABB/CG for SF 6 breaker of capacity 1250 amps of rating 36 KV complete all as specified and as directed.
S&F in replacement of closing coil assembly 50 volts DC of existing make for VCB of capacity 1250 amps of rating 36 KV complete all as specified and as directed.
S&F in replacement of triping coil assembly 50 volts DC of existing make ABB/CG for SF 6 breaker of capacity 1250 amps of rating 36 KV complete all as specified and as directed.
S&F in replacement of tripping coil assembly 50 volts DC of existing make for VCB of capacity 1250 amps of rating 36 KV complete all as specified and as directed..
S&F in replacement of motor & gear assembly 110/220V AC complete all as specified and as directed
Material & labour for repair /overhauling/Servicing of OLTC ( On load tap changer ) of 33KV/11KV Power transformer of capacities 8/10 10 MVA at site by carried out following work of make :- Schenider (a) Opening of top plate of OLTC. (b) Draining out of transformers oil from the OLTC. (c) Stoping of leakage of oil from main shaft of OLTC including replacement of oil seal and all gasket of OLTC. (d) Checking /servicing of moving and fixed contact of OLTC and resistence test of contact. (e) Flushing of OLTC assembly with hot new oil and removing of sludge. (f) Filling of new transformer oil in OLTC. (g) Tightening of all tapping leads and connections. (h) Refixing of top plate of OLTC in original position after overhauling. (i) Electrical testing of manual/auto operation of OLTC. Note :- Transformer oil as required shall be measured and paid separately under item No 3 here-in -before as supply only.
Material and labour for Preparation of old painted surfaces of steel by brushing/cleaning stain, greasy spots with thinner, applying two coats of spray painting (synthetic enamel paint) on all sides of 33 KV outdoor SF-6 breakers with spraying machine including writing description of equipment in block English letter 50 mm high with white/black synthetic enamel paint complete all as specified and as directed.
Material and labour for Preparation of old painted surfaces of steel by brushing/cleaning stain, greasy spots with thinner, applying two coats of spray painting (synthetic enamel paint) on all sides of Terminal Kiosk (TK) at 33 KV Yard with spraying machine including writing description of equipment in block English letter 25 mm high with white /black synthetic enamel paint complete all as specified and as directed.
Material and labour for Preparation of old painted surfaces of 33 KV Switch yard including all outer steel structures/ frame/gate of bus bay at Grid, having dimensions 47. m x 5.6m x 10m and steel housing of capacitor bank having dimension 9.5m x 8.8m (incluiding top closed) by brushing/cleaning stains, greasy spots with thinner, applying two coats of spray painting (synthetic enamel paint) with spraying machine in the yard including writing description of equipments in block English letters 100 mm high with white/black synthetic enamel paint complete all as specified and directed.
S&F in replacement PG clamps aluminium cast alloy (bi-metallic type) suitable for existing ACSR conductor of type Zebra/Panther/Sheep with GI nuts bolts complete all as specified and directed
S&F in replacement T-connectors/clamps aluminium cast alloy (bi-metallic type) suitable for existing ACSR conductor of type Zebra/Panther/Sheep with GI nuts bolts complete all as specified and directed
S&F in replacement CT clamps aluminium cast alloy (bi-metallic type) for both terminals suitable for ACSR conductor of type Zebra/Panther/Sheep with GI nuts bolts complete all as specified and directed
S&F in replacement PT clamps aluminium cast alloy (bi-metallic type) for both terminals suitable for ACSR conductor of type Zebra/Panther/Sheep with GI nuts bolts complete all as specified and directed
S&F in replacement Isolator clamps aluminium cast alloy (bi-metallic type) for both terminals suitable for ACSR conductor of type Zebra/Panther/Sheep with GI nuts bolts complete all as specified and directed
S&F in replacement SF-6 Breaker clamps aluminium cast alloy (bi-metallic type) for both terminals suitable for ACSR conductor of type Zebra/Panther/Sheep with GI nuts bolts complete all as specified and directed
S&F in replacement Line spacer clamps aluminium cast alloy (bi-metallic type) for both terminals suitable for ACSR conductor of type Zebra/Panther/Sheep with GI nuts bolts complete all as specified and directed
S&F in replacement silica gel with breather assembly, suitable for power transformer 33KV/11KV of 10/16 MVA capacity complete all as specified and directed
S&F in replacement of disc insulator with hardware fittings 33 KV grade complete all as specified and directed.
S&F in replacement of pin insulator with hardware fittings 33 KV grade complete all as specified and directed.
Material and labour for spreading of stone aggregate of nominal size not more than 40mm from the bay/yard manually without damaging any equipments, cable or parts of the 33 KV Grid bays, spreading & levelling of finished gravel uniformaly in layers n. exc. 15 cm thick watered and rammed to true surface all as specified and directed
M&L for Servicing & Repairs to Air-break switch (isolator) off load, rotating type, 33 KV, 800 Amps to 1250 Amps capacity, with proper alignment of isolator rotating blades, with fixed contact jaws, arcing horns, applying petrolium jelly to moving mechanism, cleaning and lubricating to isolator gear box assembly, tightening all nuts, bolts and clamps of jumpers etc, repairing to isolator gear box assembly and making in proper serviceable condition for smooth functioning, testing and commissioning on load complete all as specified and directed all items.
Supplying and Fixing in repairs, male/moving contact/ rotating blade of HDE copper silver plated of Air Brake, off load isolator switch, rotating type, 33 KV, 1250/800 Amps capacity with all fixing nuts, bolts etc complete all as specified and directed.
Supplying and Fixing in repairs, Fixed Contacts, made of HDE copper, silver plated, of Air Brake, off load isolator switch, rotating type, 33 KV, 1250/800 Amps capacity with all fixing nuts, bolts etc. complete all as specified and directed.
Supplying and fixing in replacement of terminal pad for Air Brake, off load isolator switch, rotating type, 33 KV, 1250/800 Amps capacity
Supplying and fixing in replacement of arching horn for Air Brake, off load isolator switch, rotating type, 33 KV, 1250/800 Amps capacity
Supplying and fixing in replacement of auxilary switch 16 Amp having (5 NO5 NC) suitable for Air Brake, off load isolator switch, rotating type, 33 KV, 1250/800 Amps capacity
Supply , installation, testing and commissioning in replacement of air brake off load line isolator switch rotating type manually gear drive mechanism operated highest system voltage 36 KV rated current 1250 Amps triple pole with earthing device each pole consist of insulating pedestals 03 Nos on galvanized steel base as per BSS /IS incuding rotating blade of HDE copper and fixed contacts of same material , spring loaded arcing horns of adequate section to brake magnetizing current of transformer as directed with adequate 50mm dia GI operating pipe for operation from ground level and operating handle complete with both off and on positions complete all as specified and directed.
Supply, installation, testing and commissioning in replacement of lightening arrestor SMX type complete with all fittings transmission class 36 KV 10 KA 50 Hz suitable for system voltage 33/36 KV complete all as specified and directed
Supplying ,fixing , testing of master trip relay , 50/24 Volt DC in control panel including wiring complete as directed at site
Supplying ,fixing , testing of Trip circuit supervision relay , 50/24 Volt DC in control panel including wiring complete as directed at site
Supplying ,fixing , testing of DC supervision relay relay , 50/24 Volt DC in control panel including wiring complete as directed at site
Supplying,fixing,testing of PT fuse failure relay,110 Volt AC in control panel including wiring complete as directed at site
Supply installation, testing and commissioning in replacement Potential Transformer (PT) oil cooled out door single phase ( Earthed type) of voltage ratio 33 KV/110 V class 3P - 0.5-3, burden 50 VA insulation level of 70/170 KV as specified below:- (a) Normal System Voltage-33 KV. (b) Highest System Voltage-36 KV. (c) Rated Primary voltage- 33 KV/√3. (d) Rated secondary voltage- 110 V/√3. (e) Nos of Lt winding 2. (f) Metering Core Accuracy class - 0.5. (g) Metering Core Rated Burden- 50 VA. (h) Nos of Phase- Single (Earthed Type) (j) Protection core accuracy class - 3P. (k) Protection core rated Burden - 50 VA. (l) Rated Voltage Factor - 1.2 continuous & 1.5 for 30 Sec. (m) Insulation Level- 36/70 KV.170 KVP. (n) Temp rise at rated contineous thermal current over ambient at site - 45 0C. (o) Porcelain Bushing type - Hollow Cylinder (p) 1.2/50 mcro second impulse withstand test vol -170 KV (Peak). (q) Creepage distance of HV bushing - 900 mm (min). (r) Primary & Secondary winding material - Copper
Supply and laying PVC insulated PVC sheathed cable galvanized steel strip or wire armoured electric control cables (Heavy duty) with stranded Copper conductor of size 2.5 sq mm 10 core 1100 Volts grade complete all as specified and directed.
All as per item No. 41 above but 2.5 sqmm 6 core copper conductor.
Material of labour for removal of aggaregate including Hard surface cutting in PCC, pavement, etc for laying of control cables, pipes etc of any size up to a approximate width 45 cm and depth 45 cm and making good and refilling of aggregate after laying of pipe and cable complete all as directed at sie
Supplying, installation, commissioning and testing in replacement of 11 KV Current Transformer (CT`s), indoor type, epoxy cast resin having ratio 1000/500/5-5 Amps , core -1, Class 5 P10 , 15 VA for protection , Core 2 Class 0.5 , 15 VA for metering, Short circuit time rating 13.4 kA for 3 Sec including associated wiring complete all as specified and directed
Supplying, installation, commissioning and testing in replacement of 11 KV Current Transformer (CT`s), indoor type, epoxy cast resin having ratio 400/200/5-5 Amps , core -1, Class 5 P10 , 15 VA for protection , Core 2 Class 0.5 , 15 VA for metering, Short circuit time rating 13.4 kA for 3 Sec including associated wiring complete all as specified and directed
Supplying, installation, commissioning and testing in replacement of 11 KV Current Transformer (CT`s), indoor type, epoxy cast resin having ratio 600/300/5-5 Amps , core -1, Class 5 P10 , 15 VA for protection , Core 2 Class 0.5 , 15 VA for metering, Short circuit time rating 13.4 kA for 3 Sec including associated wiring complete all as specified and directed
S&F in replacement of vacuum interrupter suitable for 630/800/1250amps, 11 KV HT VCB complete all as specified and directed
Supplying & Fixing in replacement support rod with screws suitable for 630/800/1250 amps, 11 KV HT VCB complete all as specified and directed
Supplying & Fixing in replacement support insulator suitable for 630/800/1250 amps, 11 KV HT VCB complete all as specified and directed
Supplying & Fixing in replacement upper connector suitable for 630/800/1250 amps, 11 KV HT VCB complete all as specified and directed
Supplying & Fixing in replacement lower connector suitable for 630/800/1250 amps, 11 KV HT VCB complete all as specified and directed
M&L for Rewinding of heavy duty cooling fan, 3 phase, 50 Hz of size 24" of power transformer 33/11 KV capacity with super enamelled copper wire as per existing gauge including heating, varnishing, etc complete as required and directed.
Supply and fixing of in replacement of TNC Switch 11 KV VCB 16 Amp suitable for existing 11 KV VCB.
Supplying & Fixing in replacement of spouch insulator suitable for existing 630 to 1200 amps, 11 KV HT VCB complete all as specified and directed
Supplying, laying, jointing testing and connecting XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conducators, 33 KV (E) grade, of size 400 sq mm, 3 core, laid in trenches complete all as specifed & directed in replacement of underground cable.(From AOC Sub Stn to 220 Naraina Grid) Note :- Excavation, earth work, cable protection, sand fillings, cable joint shall be measured and paid separately.
Supplying, laying, jointing testing and connecting in replacement XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 11 KV grade, IS 7098 marked, suitable for HT 11 KV(E) system, laid in trenches / ducts / encased in GI pipe / fixed to pole, including jointing & testing complete all as specified and directed of following sizes
120 sqmm 3 core.
185 sqmm 3 core
240 sqmm 3 core
300 sqmm 3 core
Supply &Fix in replacement of HDPE Pipe with necessary accessories/ fittings for cable protection/ pole for crossing of culverts/nalah/ Road of following bore sizes:-
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom suface to required level all as specified and directed by Engineer- in- Charge.
Returning filling in,. Including spreading, levelling,. Watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed.
Removing excavated material (ie soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified.
Supplying & Laying reinforced precast concrete cable cover, class EHV, type 1 with peak, size 450mm x 230mm x 50mm in trenches for protecting under groung cable as per IS (for 33 KV Cable) complete all as specified and directed.
Laying only old cover obtained sri item No 58 here in before.
Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1, flat size 300mmx 180mm x 40mm in trenches for protecting under groung cable as per IS complete all as specified and directed..
Laying only old cable cove obtained under srl item No 58 here in before.
Material & Labour for Bore earthig 150 mm dia buried by vertical boring machine, depth 50 mtr below ground level using earth electrode 50mm dia GI pipe medium grade duly drilled hole of 12mm dia, 115mm C/C on both side of the pipe including lowering in bore well upto the depth of 49 mtr and one mtr above the ground level. The pipe electrode should be filled around commericial salt charcoal dust, copper sulphate and magnesium phosphate of 30 cm layer each upto the full length of pipe. The borewell should have 12 mtr of length 150mm dia MS pipe for protection of borewell. Welding of GI Strip 50mmx6mm on earth electrode GI Pipe 50mm dia upto 10mtr below ground level and 15 mtr from the bore well to test point gun metal and PCC foundation surrounding the borewell 60cmx60cmx30cm all as directed by Engr-in-charge. GI strip more than 25mtr will be measured and paid separately. Note :- Cost of gun metal test point deemed to be included in the quoted rate.
Supply, installation, testing and commissioning in replacement 33 KV current transformer oil cooled out door single phase, oil immersed and self cooled type of ratio 800-400/1-1-1-1 suitable for metering and protection equipment installed on control panels terminal block as specified below :- (a) Normal System Voltage-33 KV. (b) Highest System Voltage-36 KV. (c) Rated Primary current- 800-400 Amp. (d) Rated secondary current- 1 Amp. (e) Nos of Core - 4. (f) Core01: Accuracy class 5P10, 10VA, ALF ≥10. (g) Core02: Accuracy Class 1.0, 10VA, ISF ≤ 5. (h) Core 03 Protection core accuracy class -PS,Protection knee point voltage- 300 Volt at lower ratio. (j) Core 04-Spare. (k) Continuous thermal current rating 120 % of rated primary current. (l) Temp rise at rated contineous thermal current over ambient at site - Less than or equal to 45 degree C. (m) Insulation Level- 36/70 KV.170 KVP. (n)1.2/50 Micro second impulse withstand test voltage-170 KV (peak). (o) Short time thermal current rating for one second- 25 KA/1 Second. (p) Dynamic Current Rating - 62.5 KA ( peak). (q) Porcelain Bushing type - Hollow Cylinder. (r) Creepage distance of HV bushing - 900 mm (min). (s) Primary & Secondary winding material - Copper
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 1000 sqmm single core XLPE armoured aluminium conductor cable complete all as specified and directed.
Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 33/11 KV HT cables of different sizes from both ends, removal of Fault, Re-connections and testing of ables after removal of fault complete all as specified and directed. Note: (a) 33/11 KV HT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable cable cover will be laid in trenches for cable protection. If extra PCC cover and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Excavation and earth work will be measured and paid for seperately under respective items of schedule.
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following size:-
120 Sqmm to 185 Sqmm, 3 core.
240 Sqmm to 300 Sqmm 3 core
Boring of hole under road/pavement/hard standing or any other situation by mannual means and suitable for passing of GI pipe 110 to 140 mm bore and making good both ends all specified and directed
Supply and fix cable jointing kit for 33 KV (Earthed ) grade cable for straight though heat shrink type joint complete with jointing meterial and accessories suitable for XLPE armoured aluminium conductor cable of size 3 core 400 sqmm.
Supply, installed, testing and commissioning in replacement of factory made tested LT Panel compartmentalised cubical outdoor type Floor mounted suitable for , 415 volts 3 phase, 4 wire,50 HZ AC supply system having bus bar chamber with insulated aluminium bus bar of rating 1200 Amp installed on proceline/ SMC insulator. The panel should be dust and vermin proof IP -65 class protection and made of 3.15 mm CRCA MS sheet and 50X50X6 mm thick MS angle iron frame work, powder coated finesh over one coat of red oxide on out side surface and painted in side with two coated of red oxide primer and rear opening type with apran for cable entry, closing locking arrangement including internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked , 1100 volts grade of appropriate size and comprising of the following including necessary PCC platform of suitable size (Location - BOR Sub Stn) INCOMING:- (i) ACB drawn-out type with adjustable microprocessor release confirm to IS/IEC:60947-2, 4 pole , LT 415 Volts, 50 Hz AC grade of 800 Amps rating 50 KA rupturing capacity with suitable for adjustable over load current and short circuit and earth fault protection - 01 No.
(i) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 250 Amps rating 35 KA rupturing capacitiy with adjustable Themal and Meganetic setting releases, - 01 Nos. (ii) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 200 Amps rating 35 KA rupturing capacitiy with adjustable Themal and Meganetic setting releases,- 01 Nos. (iii) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 63 Amps rating 25 KA rupturing capacitiy with adjustable Themal and Meganetic setting releases, - 01 Nos.
Supply, installed, testing and commissioning in replacement of factory made tested LT Feeder Pillarl compartmentalised cubical outdoor type Floor mounted suitable for , 415 volts 3 phase, 4 wire,50 HZ AC supply system having bus bar chamber with insulated aluminium bus bar of rating 1000 Amp installed on proceline/ SMC insulator. The panel should be dust and vermin proof IP -65 class protection and made of 3.15 mm CRCA MS sheet and 50X50X6 mm thick MS angle iron frame work, powder coated finesh over one coat of red oxide on out side surface and painted in side with two coated of red oxide primer and rear opening type with apran for cable entry, closing locking arrangement including internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked , 1100 volts grade of appropriate size and comprising of the following including necessary PCC platform of suitable size (Location - Kirby Offrs MD Accn) INCOMING:- (i) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade of 630 Amps rating 50 KA rupturing capacitiy with adjustable Themal and Meganetic setting releases, - 01 Nos.
Rajindera Enterprises
mayur enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .