Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.5 LAccepted-AOC THE JEHOVAH SHALOM 21 THIRUMALAISAMY STREET LAKSHMI NAGAR EXTN KAVUNDAMPALAYAM COIMBATORE 641030 | COIMBATORE | COIMBATORE | TAMIL NADU | 641030 | L1 | Accepted-AOC L1 | |
| 2 | L2₹26.6 L+₹2.2 L (8.81%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹27.0 L+₹2.5 L (10.3%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹27.1 L+₹2.6 L (10.8%)Rejected-Finance KALIAPPA COMPLEX THRICHY ROAD RANGANATHAPURAM SULUR COIMBATORE 641 402 | COIMBATORE | COIMBATORE | TAMIL NADU | 641402 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹30.1 L+₹5.6 L (22.8%)Rejected-Finance NO 17 PETER GNANA PRAKASAM NAGAR MARIYAMMAN KOVIL PO THANJAVUR 611501 | 611501 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹35.4 L
EMD Value
₹70,760
Closing Date
4 Feb 2023, 6:00 pmClosed
GARRISON ENGINEER AIRFORCE THANJAVUR
GARRISON ENGINEER AIRFORCE THANJAVUR
PROVISION OF RCCB IN LIEU OF MCB AND SWIVEL LIGHTS WITH ALLIED WORKS AT AFS THANJAVUR
2022_MES_572465_1
8931/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
THANJAVUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER AIRFORCE THANJAVUR
₹70,760
Yes
21 Feb 2023
31 Dec 2022
6 Feb 2023
31 Dec 2022
4 Feb 2023
22 Jan 2023
Amount
Supply and fix RCCB- 4 pole 100A, 10KA short circuit current withstand capacity with sensityvity of 30 mA suitable for 415V, (IS-12640 & IEC 61008-1) complete including taking down of old MCB from existing DB, all as specified and directed. Make : L&T Cat part No. AURAD410003 or equivlant in Legrand / Schneider
Supply and fix RCCB- 4 pole 63A, 10KA short circuit current withstand capacity with sensityvity of 30 mA suitable for 415V, (IS-12640 & IEC 61008-1) complete including taking down of old MCB from existing DB, all as specified and directed. Make : L&T Cat part No. AURAD406303 or equivlant in Legrand / Schneider
Supply and fix RCCB- 4 pole 40A, 10KA short circuit current withstand capacity with sensityvity of 30 mA suitable for 415V, (IS-12640 & IEC 61008-1) complete including taking down of old MCB from existing DB, all as specified and directed. Make : L&T Cat part No. AURAD404003 or equivlant in Legrand / Schneider
Supply and fix RCCB- 2 pole 40A, 10KA short circuit current withstand capacity with sensityvity of 30 mA suitable for 230V, (IS-12640 & IEC 61008-1) complete including taking down of old MCB from existing DB, all as specified and directed. Make : L&T Cat part No. AURAD204003 or equivlant in Legrand / Schneider
Material and labour for earthing complete with galvanised steel plate electrodes of size 600x600x6mm thick burried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised 4.0mm dia earth lead by means of nuts bolts check nuts GI washers earth wire protected by galvanised iron or steel all as shown in electrical Plate No-3 connected to earthing test point all as specified or indicated including testing on completion.
Supply, fixing, testing and commissioning of long range Swivel light / flood light, weather / vermin proof LED light including fixtures complete with aluminium body having high conductivity heat sinks toughened glass cover with rubber gasket held in position with help of cast aluminium retaining ring, long beam LEDs with suitable electronic driver,supplied with 1m tripod stand with castrol wheels for ease of movement inside the watch tower cabin operated in 230 volt AC supply 250 watt long range and its control gear in cast aluminium housing complete all as per Sigma type No 24450L-TS or equivalent in Havells/Philips.
M&L for sub main wiring with 2 run of 1.5 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core flame retardant low smoke cable (FRLS) of working voltage 1100 volts grade with stranded copper conductor including one run of 1.5 Sqmm (nominal cross sectional area) PVC insulated unsheathed flame retardant cable (FR) with stranded copper conductor as continuous earth wire connected to main switches DBs or in common earth dolly drawn with and including 20 mm dia PVC rigid non- metallic conduit after and including taking down / dismantling old sub main wiring including old conduit / casing capping / wooden batten etc of any description complete all as specified and as directed.
S&F Sheet metal enclosure for 2 way Distribution Boards (DB’s), single door, single pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB"S/lsolators after and including taking down old DB with MCB complete all as specified and directed.
S&F MCB, Single pole & neutral, 6 to 32 amps, 240 volts, ‘C’ curve, 10KA complete all as specified and as directed
POWER TECH ENTERPRISES
Manoprabha Electricals
SUPER COOL
M/S. SRI RAMANUJA CONSTRUCTIONS
VVM CONSTRUCTIONS
PSK Enterprises
RISHABH BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .