| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹47.2 CrAccepted-AOC B 119 SIGMA 1 GREATER NOIDA G B NAGAR U P | ₹47.2 Cr | 1 | Accepted-AOC work order issued |
| 2 | Rejected-Technical A 732 NEW ASHOKA GARDEN BHOPAL | BHOPAL | MADHYA PRADESH | - | - | Rejected-Technical disqualified |
| 3 | Rejected-Technical | - | - | Rejected-Technical disqualified |
| 4 | Rejected-Technical NOT AVAILABLE | - | - | Rejected-Technical disqualified |
| Sl No | Description | Qty | Unit | UNIQUE ENGIVENTURE CONSORTIUM LLP |
|---|---|---|---|---|
| 1.00Description | ||||
| 1.01 | 2.7 Excavation rockEarth work in excavation/ by mechanical means (Hydraulic Excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including dressing of sides and ramming of bottom disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. - Ordinary rock | 939.38 | cum | 2,69,602.06 ₹2.7 L |
| 1.02 | 2.24 Filling available excavated earth Filling available excavated earth (excluding hard rock/Ordinary rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | 563.63 | cum | 53,544.85 ₹53,544.85 |
| 1.03 | 2.26 Under floor filling stone dustSupplying and filling in plinth with crusher stone dust / coarse sand under floors including, watering, ramming and compacting in layers not exceeding 20cm in depth and dressing complete Note: - Maximum thickness of this layer shall be 20 cm. | 187.88 | cum | 1,59,698 ₹1.6 L |
| 1.04 | 2.27 Under floor fillingSupplying and filling in plinth under floors including watering ramming consolidating in layers not exceeding 20cm in depth and dressing complete. With hard muram having CBR >12 % at under floors including watering, ramming and compacting (minimum compaction 95% of MDD) in layers not exceeding 20cm in thickness and dressing complete. (Note:- maximum thickness of this layer to be provided shall be 30cm) | 375.75 | cum | 1,69,087.5 ₹1.7 L |
| 1.05 | 4.1 C.C. upto plinth levelProviding and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level With 40mm nominal size graded stone aggregate. M-10 Nominal (Mix -1 Cement : 3 sand : 6 graded stone aggregate) | 93.94 | cum | 4,22,730 ₹4.2 L |
| 1.06 | 4.3 Centering and shutteringCentering and shuttering including strutting, propping etc. and removal of form work for : Upto plinth: Foundations, footings, bases for columns, plinth beams, curtain walls, columns below plinth. | 768 | Sqm | 1,53,600 ₹1.5 L |
| 1.07 | 4.3 Above plinthCentering and shuttering in cluding strutting, propping etc. and removal of form for: Walls (any thickness) in cluding attached pilasters butter esses, plinth beams and string courses etc. Above plinth upto 3.6 m height from plinth level | 768 | sqm | 2,30,400 ₹2.3 L |
| 1.08 | 5.16 Reinforcement Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire all wastages and overlaps, couplers (overlaps shall be provided as per requirement of IS 13920 for ductile detaling IS 456 RCC Design & SP 34 Reinforcement detailing ) etc. complete . (Note:- 1. Spacer bars (chairs) shall be paid separately as shown in the drawing and as per direction of engineer in charge. 2. No extra payment shall be done for overlaps and/or couplers. 3.Couplers shall be conforming to IS code on "Reinforcement Couplers for Mechanical Splices of Bars for Concrete Reinforcement - Specification") Thermo-Mechanically Treated bars.FE 500 D or more conforming to IS 1786 | 1,73,401.25 | kg | 1,38,72,100 ₹1.4 Cr |
| 1.09 | 5.27 BMCProviding and laying in position machine batched, machine mixed cement concrete (BMC) of M-20 grade for reinforced cement concrete work using cement content as per approved mix design including use of admixtures in recommended proportions as per IS 9103 to accelerate/retard setting, improve workability of concrete without impairing strength and durability as per direction of Engineer-in charge and pumping of concrete to site of laying and finishing but excluding the cost of centering, shuttering, and reinforcement. (Note: - Minimum cement content is 320 kg/cum) and no extra payment for extra cement used as per mix design. All works above plinth level and upto floor five level. | 788.19 | cum | 59,11,425 ₹59.1 L |
Tender Value
Refer Docs
EMD Value
₹28.8 L
Closing Date
18 Feb 2026, 5:00 pmClosed
D S Parihar
MP State tourism dev corp ltd, Bhopal
Bids are invited from reputed Artist/sculptor for Supply and Installation of Stone and Bronze Statues including construction of Pedestal and Facade lighting of the Statue at Mahakal Corridor, Ujjain 2nd call
2026_STDC_480237_1
85/Mahakal corridor Ujjain
Open Tender
Civil Works - Others
540 days
work
Please refer Tender documents.
9 documents required · 9 mandatory
₹50,000
₹28.8 L
17 Apr 2026
5 Feb 2026
19 Feb 2026
5 Feb 2026
18 Feb 2026
5 Feb 2026
Description
2.7 Excavation rockEarth work in excavation/ by mechanical means (Hydraulic Excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including dressing of sides and ramming of bottom disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. - Ordinary rock
2.24 Filling available excavated earth Filling available excavated earth (excluding hard rock/Ordinary rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
2.26 Under floor filling stone dustSupplying and filling in plinth with crusher stone dust / coarse sand under floors including, watering, ramming and compacting in layers not exceeding 20cm in depth and dressing complete Note: - Maximum thickness of this layer shall be 20 cm.
2.27 Under floor fillingSupplying and filling in plinth under floors including watering ramming consolidating in layers not exceeding 20cm in depth and dressing complete. With hard muram having CBR >12 % at under floors including watering, ramming and compacting (minimum compaction 95% of MDD) in layers not exceeding 20cm in thickness and dressing complete. (Note:- maximum thickness of this layer to be provided shall be 30cm)
4.1 C.C. upto plinth levelProviding and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level With 40mm nominal size graded stone aggregate. M-10 Nominal (Mix -1 Cement : 3 sand : 6 graded stone aggregate)
4.3 Centering and shutteringCentering and shuttering including strutting, propping etc. and removal of form work for : Upto plinth: Foundations, footings, bases for columns, plinth beams, curtain walls, columns below plinth.
4.3 Above plinthCentering and shuttering in cluding strutting, propping etc. and removal of form for: Walls (any thickness) in cluding attached pilasters butter esses, plinth beams and string courses etc. Above plinth upto 3.6 m height from plinth level
5.16 Reinforcement Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire all wastages and overlaps, couplers (overlaps shall be provided as per requirement of IS 13920 for ductile detaling IS 456 RCC Design & SP 34 Reinforcement detailing ) etc. complete . (Note:- 1. Spacer bars (chairs) shall be paid separately as shown in the drawing and as per direction of engineer in charge. 2. No extra payment shall be done for overlaps and/or couplers. 3.Couplers shall be conforming to IS code on "Reinforcement Couplers for Mechanical Splices of Bars for Concrete Reinforcement - Specification") Thermo-Mechanically Treated bars.FE 500 D or more conforming to IS 1786
5.27 BMCProviding and laying in position machine batched, machine mixed cement concrete (BMC) of M-20 grade for reinforced cement concrete work using cement content as per approved mix design including use of admixtures in recommended proportions as per IS 9103 to accelerate/retard setting, improve workability of concrete without impairing strength and durability as per direction of Engineer-in charge and pumping of concrete to site of laying and finishing but excluding the cost of centering, shuttering, and reinforcement. (Note: - Minimum cement content is 320 kg/cum) and no extra payment for extra cement used as per mix design. All works above plinth level and upto floor five level.
5.28 Extra for richer BMC mix Extra for providing richer mixes of BMC design mix as per item no 5.27 upto plinth level and at all floor levels. (No extra payment for using extra cement as per requirement of mix design.) Providing M-25 grade concrete instead of M- 20 grade.(Note : minimum cement content is @ 330 kg/cum)
13.4 12 mm cement plaster finished with a floating coat of neat cement of mix : 1:4 (1 cement : 4 sand)
Sand Stone Cladding Design,Providing and fixing Dry stone cladding upto 20 metre height with 40mm thick gang saw cut to the required size and shape as per approved drawing fixed to cement based fly ash brick/ RCC/ CC Block/ ACC block /chimney bricks walls as the case be with approved SS 304 grade steel under cut anchors and specified metal frame system. Cladding pattern shall be as per approved drawings, in singal size or in combination of different sizes / materials of stone of required finish , shade and as per approved sample. At the cornor 'L' shape angle stone shall be fixed, so joint line can't be appear at corners. "L" shape stone shall be cut from stone box with wire cutting machine of required thickness as per design ( thickness may be vary as per design, contractor shall not claim for the same ). Offset shall be provided in stone thickness to create groove of approximate size 10 mm, Steel frame ( SS 304 grade steel ) member shall be fixed with adjustable steel bracket ( SS 304 grade steel ) etc complete in all respect as per direction of engineer in charge. Pink Banshi Phadpur Sand Stone Cladding work - 40mm( Thick).
STATUE( MURTI) with design,supply,Transporting, hoisting and fixing in a position with good quality durable Banshi Phadhpur pink sandstone of approved shade of specified size and thickness for all the heights. Statue shall be meticulously hand and machine both carved with intricate details, featuring the deity’s traditional attributes like his HastAstras and royal posture. The statue shall capture a sense of majesty and divine authority with lifelike proportions and expressive featuresStone shall be hard, sound durable and tough, free from cracks, decay and weathering effect and defects like cavities, flaws, holes, veins, patches of soft or loose materials etc. The work shall be carried out as per design based on concept image with different process of carving (manual/ CNC machine/water jet machine). The STATUE to be fixed in line, Level and plumb including in all respect with the use of copper pins, dowels, epoxy or stone fixing adhesive of approved make and cement mortar with matching pigment as required and as approved by the architect's and Employer's representative. The stone surface of Statue shall be finely polished or left with a natural, textured finish, depending on the desired look as per directed by Engineer's representative.All the work shall be executed as per sample approved by Employer's / Engineer's representative. including all the material,mock-up, labour, including all applicable taxes (excluding GST), transportation,fixing in position, cranes, machines, tools, tackles, equipment’s, Wastage, Water Repellent coating, buffing, finishing, cleaning etc, maintaining up till handling over the project etc complete. The rate shall also include the cutting, bending and installation of copper strips and pins as required for the connection , water and power with necessary cable & accessories required for cutting, Mock-up / samples , Carving, installation and finishing work, repairing of stone (if any), the safety appliance, supply of scaffolding material & installation as well as dismantling of scaffolding material in safe manner as per the requirements of statue installation etc. complete in all respect as per direction of engineer in charge.
Clay Mock & 3D Scanning Making of Clay mockup & 3D scanning of the same: Preparation of clay mockup in 1:1 scale based on the conceptual sketch prepared by subject expert. Including providing high resolution 3D scanned data of the same. The mockup shall be made in Artistic clay suitable to make silicon mould for further casting. The mockup shall be retained untill the 3D scanning & casting mould for the same is completed. The mockup shall include all required changes & corrections as guided by engineer incharge & Subject expert, Artist is required to prepare mockup with coordination of Subject expert. for the: Statue Height from 10' to 14'
Statue Height from 14' to 18'
Statue Height from 18' to 20'.
Statue Height from 30' to 35'
Wider Statues of Height 9' width 9'
Wider Statues of Height 12' width 6'
Wider Statues of Height 15' width 15'
Wider Statues of Height 16' width 14'
Wider Statues of Height 17' width 12'
Wider Statues of Height 20' width 12'
Wider Statues of Height 22' width 15'
Bronze Statue casting, Supply, Installation & fixing of Bronze alloy (copper 88%, Tin 8% lead 4%) statue of various deities as per approved claymocks with average thickness of 6mm, including all required SS frame inside to support duly painted with coroson resistance paint of approved brand & fix the statue at designated place. The Statue shall be casted in lost wax method. All visible surface shall be treated with Patina etc. complete in all respect as per direction of Engineer in charge.
Concealed PVC conduit HMS Supply and fixing PVC conduit ISI marked FRLS along with the accessories in concealed system etc. as required PVC. conduit 25 mm (HMS)
PVC. conduit 32 mm (HMS)
PVC. conduit 40 mm (HMS)
22.1 Wiring for sub-mains with PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid PVC conduit (MMS) FRLS ISI marked of suitable size (conduit included) including 2mm thick accessories, connection etc, as required as per specification. (Refer General Notes for Classification of Conduit Wiring Point No.11) 3 Wire sub main 2.5 sq. mm. cable
4.0 sq. mm. cable
MCCB 3Ph, 3Pole, 50Hz, 415V (Micro-processor release) Supplying of ISI marked and approved make of moulded case circuit breaker (MCCB) suitable for 3 phase,3 pole, 50 Hz, 415 Volts, (Ics=100%Icu) AC supply with Micro-Processor release having respective breaking capacity (KA) at 415 Volts cited against their range standard conforming to IS/IEC 60947-2 MCCB 25kA current rating - 40 & 100Amp 3 Pole µ-processor release, over load 40% -100% x In. & short circuit 1.5 - 8 x Ir. adjustable
MCCB 25kA current rating - 250Amp 3 Pole µ-processor release, over load 40% -100% x In. & short circuit 1.5 - 8 x Ir. adjustable
Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of 'C' series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures :- Single pole MCB SP 0.5Amp to 5Amp 10kA rating
MCB SP 6Amp to 32Amp 10kA rating
Double pole MCB DP 6Amp to 32Amp 10kA rating
MCB DP For 40Amp 10kA rating
MCB DP 50Amp to 63Amp 10kA rating
Supply and fixing of multi core (flexible) conductor & PVC sheathed approved make round FRLSH PVC insulated copper cables 1100Volts as per IS:694-1990 of (50/0.25 mm) Three core 2.5 sq.mm.
(56/0.3 mm) Three core 4.0 sq.mm.
Frequency Metre
Copper bus bar strips with PVC sleeves
LED lamp indicator
Supply and erection of approved make safe earthing electrode consisting pipe-in-pipe technology as per IS 3043-1987 made of corrosion free G.I. pipes with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for effective and maintenance free earthing in earth pit of minimum bore dia. 150mm size, as mentioned below : With 2 metre pipe of 80mm outer dia., 40mm inner dia and 14mm terminal dia. In soft/hard ock/marshy soil with 25 kgs. (one bag) back filling bentonite compound UL listed and confirm to relevant International/Indian standards around electrode Upto ground level.
With 3 metre pipe of 80mm outer dia., 40mm inner dia and 14mm terminal dia. In soft/hard Lock/marshy soil with 50 kgs. (two bag) back filling bentonite compound UL listed and confirm to relevant International/Indian standards around electrode upto ground level.
Providing back filling bentonite compound suitable for safe earthing device. The product should be UL listed and confirm to relevant International/Indian standards.
Supply and installation of polycarbonate heavy duty pit cover tested for 5000Kg SWL for earth electrode at ground level size 300x300x155 mm with lockable lid.
Supply and laying 25mm X 5mm G.I. strip at 0.5 metre below ground level as strip earth electrode including jointing etc. as required.
Providing and fixing 25mm X 5mm copper strip in 40 mm dia G.I. Pipe from earth electrode as required
Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu. stranded /solid conductor 3½ core armoured 35 sq. mm
4 core armoured6 sq. mm.
Supply of XLPE insulated FRLS heavy duty power cable conforming IS-7098 (Part-1) 1988, 1100 Volt grade, 2/3/4/8/10/12 core ISI marked with copper Armoured 3 corestranded/solid conductor.2.5 sq. mm.
Supplying and fixing heavy duty cable gland for P.V.C. insulated armoured cable with brass washer, rubber ring complete erected with cable and lead connection etc. as per specification complete. Gland size 22mm suitable for cable 2/3, 3½, 2/4 x 10 sq. mm or 2x 16 sq. mm
Gland size 32 mm for 2/3, 3½, 4 x 25 sq. mm OR 2/3, 3½ x 35 sq. mm or 2/3/3½ x 50 sq. mm.
Supplying and fixing crimping type alum. lugs as per I.S.S. specification suitable for following size of cable with alu./copper solid/stranded conductor evenly crimped with high/pressure tool and connected to switch gear/bus/M.C.C.B./M.C.B. etc. as required complete. 6mm to 16 sq. mm
Supplying and installing double wall corrugated pipes (DWC) of HDPE (IS 14930 Part II -marked) for cable laid underground with necessary material and at required depth upto 90cm. below road/ground surface, including excavation, back filling with excavated material, ramming and making the surface good. 50.00mm outside dia.
63.00mm outside dia.
Laying of one number armoured / unarmoured power cable 1.1 KV grade of size not exceeding 25 sq. mm direct in ground including excavation in all soil/ murrum /soft rock, sand cushioning, protective covering and refilling the pit etc. as required.
Supplying and erection of water tight terminal box made of PC-GFS (polycarbonate),IP 66 /IP 67 (cable entry systems LES) in accordance with IEC 60670-22, resistant to weather influences (UV due to solar radiation, protected against rainwater, temperature resistant, impact resistant, etc. insulation voltage 1000 V a.c./d.c., wall thickness of the bottom part 2 / 2.7 mm of required size suitable for kit at/MCB/switch including 2 nos. pole clamp of M.S. flat iron size 32x3mm, nut and bolts, excluding the cost of the kit kat/MCB/Switch, 4 Pole epoxy connector nut & bolt type, 30Amp, 500Volt complete as per specification as mentioned below. 155 x 210 x 92 mm
Supply, Installation, lying, drawing of 4 Pair CAT6A U/FTP Cable having 23AWG condutor, LSZH Compliant with ETL & TIA/EIA- 568-C.2, Coupling Attenuation should be 45dB min @30‐100 MHz 40‐20 Log (f/100) @ 100‐500 MHz, Should be certified by ETL/UL in existing conduit / wiring system as direction of EIC
Supply installation Testing and Commisioning Round flood light, 24W, 1565 lumens ±10%, 15° beam ±10%, 3000K ±150K: Supply of exterior-rated architectural floor/wall/Pole mounted, IP66, round flood light complete with antiglare snoot. The power consumption should be not more than 24 watts, minimum system lumen delivered shall be 1565 lumens ±10%, 15° beam angle ±10%, CCT-3000K ±150K. LED from CREE/NICHIA/LUMILED/OSRAM. The housing material should be die-cast aluminum with Electrostatically applied polyester powder coating, The luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses and a clear tempered glass cover. Bracket shall have a locking mechanism to fix and secure the required tilting angle, ±90°. It should have CRI>80, and SDCM≤4. The driver should be integrated AC with PF>0.9 & and THD<20%. Leader cables, jumper cables, and IP68 connectors are included, minimum IK06. The operating temperature should be of -40°C to 50°C range and the storage temperature shall be -40°C to 70°C. the weight of luminaire shall be min 1.8kg. The lifetime of the luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self-declaration of ASTM B117 for 500 hours of salt spray test. Photometric data shall be passed on test results from an independent testing lab. All mounting accessories shall be stainless steel (Minimum -316) for all lighting fixtures. All hardwired connections to LED fixture shall be reverse-polarity protected and shall provide high-voltage protection in the event that connections are reversed or shorted during installation. The luminaire should be BIS-certified. The luminaire manufacturer shall provide optical performance, polar diagram and photometric data in various formats including IES files in accordance with IES 79-08. This includes all the required hardware for the successful operation of the luminaire. All the technical parameters of the luminaire need approval from the lighting consultant
Supply installation Testing and Commissinoning Round flood light, 40W, 2435 lumens ±10%, 15° beam ±10%, 3000K ±150K: Supply of exterior-rated architectural floor/wall/Pole mounted, IP66, round flood light complete with antiglare snoot. The power consumption should be not more than 40 watts, minimum system lumen delivered shall be 2435 lumens ±10%, 15° beam angle ±10%, CCT-3000K ±150K. LED from CREE/NICHIA/LUMILED/OSRAM. The housing material should be die-cast aluminum with Electrostatically applied polyester powder coating, The luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses and a clear tempered glass cover. Bracket shall have a locking mechanism to fix and secure the required tilting angle, ±90°. It should have CRI>80, and SDCM≤4. The driver should be integrated AC with PF>0.9 & and THD<20%. Leader cables, jumper cables, and IP68 connectors are included, minimum IK06. The operating temperature should be of -40°C to 50°C range and the storage temperature shall be -40°C to 70°C. the weight of luminaire shall be min 3kg. The lifetime of the luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self-declaration of ASTM B117 for 500 hours of salt spray test. Photometric data shall be passed on test results from an independent testing lab. All mounting accessories shall be stainless steel (Minimum -316) for all lighting fixtures. All hardwired connections to LED fixture shall be reverse-polarity protected and shall provide high-voltage protection in the event that connections are reversed or shorted during installation. The luminaire should be BIS-certified. The luminaire manufacturer shall provide optical performance, polar diagram and photometric data in various formats including IES files in accordance with IES 79-08. This includes all the required hardware for the successful operation of the luminaire. All the technical parameters of the luminaire need approval from the lighting consultant
Supply installation Testing and Commissinoning Round flood light, 50W, 2985 lumens ±10%, 15° beam ±10%, 3000K ±150K: Supply of exterior-rated architectural floor/wall/Pole mounted, IP66, round flood light complete with antiglare snoot. The power consumption should be not more than 50 watts, minimum system lumen delivered shall be 2985 lumens ±10%, 15° beam angle ±10%, CCT-3000K ±150K. LED from CREE/NICHIA/LUMILED/OSRAM. The housing material should be die-cast aluminum with Electrostatically applied polyester powder coating, The luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses and a clear tempered glass cover. Bracket shall have a locking mechanism to fix and secure the required tilting angle, ±90°. It should have CRI>80, and SDCM≤4. The driver should be integrated AC with PF>0.9 & and THD<20%. Leader cables, jumper cables, and IP68 connectors are included, minimum IK06. The operating temperature should be of -40°C to 50°C range and the storage temperature shall be -40°C to 70°C. the weight of luminaire shall be min 3kg. The lifetime of the luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self-declaration of ASTM B117 for 500 hours of salt spray test. Photometric data shall be passed on test results from an independent testing lab. All mounting accessories shall be stainless steel (Minimum -316) for all lighting fixtures. All hardwired connections to LED fixture shall be reverse-polarity protected and shall provide high-voltage protection in the event that connections are reversed or shorted during installation. The luminaire should be BIS-certified. The luminaire manufacturer shall provide optical performance, polar diagram and photometric data in various formats including IES files in accordance with IES 79-08. This includes all the required hardware for the successful operation of the luminaire. All the technical parameters of the luminaire need approval from the lighting consultant
Supply installation Testing and Commissinoning Round flood light, 80W, 5045 lumens ±10%, 15° beam ±10%, 3000K ±150K: Supply of exterior-rated architectural floor/wall/Pole mounted, IP66, round flood light complete with antiglare snoot. The power consumption should be not more than 80 watts, minimum system lumen delivered shall be 5045 lumens ±10%, 15° beam angle ±10%, CCT-3000K ±150K. LED from CREE/NICHIA/LUMILED/OSRAM. The housing material should be die-cast aluminum with Electrostatically applied polyester powder coating, The luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses and a clear tempered glass cover. Bracket shall have a locking mechanism to fix and secure the required tilting angle, ±90°. It should have CRI>80, and SDCM≤4. The driver should be integrated AC with PF>0.9 & and THD<20%. Leader cables, jumper cables, and IP68 connectors are included, minimum IK06. The operating temperature should be of -40°C to 50°C range and the storage temperature shall be -40°C to 70°C. the weight of luminaire shall be min 3kg. The lifetime of the luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self-declaration of ASTM B117 for 500 hours of salt spray test. Photometric data shall be passed on test results from an independent testing lab. All mounting accessories shall be stainless steel (Minimum -316) for all lighting fixtures. All hardwired connections to LED fixture shall be reverse-polarity protected and shall provide high-voltage protection in the event that connections are reversed or shorted during installation. The luminaire should be BIS-certified. The luminaire manufacturer shall provide optical performance, polar diagram and photometric data in various formats including IES files in accordance with IES 79-08. This includes all the required hardware for the successful operation of the luminaire. All the technical parameters of the luminaire need approval from the lighting consultant
Supply installation Testing and Commissinoning Round flood light, 100W, 6220 lumens ±10%, 15° beam ±10%, 3000K ±150K: Supply of exterior-rated architectural floor/wall/Pole mounted, IP66, round flood light complete with antiglare snoot. The power consumption should be not more than 100 watts, minimum system lumen delivered shall be 6220 lumens ±10%, 15° beam angle ±10%, CCT-3000K ±150K. LED from CREE/NICHIA/LUMILED/OSRAM. The housing material should be die-cast aluminum with Electrostatically applied polyester powder coating, The luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses and a clear tempered glass cover. Bracket shall have a locking mechanism to fix and secure the required tilting angle, ±90°. It should have CRI>80, and SDCM≤4. The driver should be integrated AC with PF>0.9 & and THD<20%. Leader cables, jumper cables, and IP68 connectors are included, minimum IK06. The operating temperature should be of -40°C to 50°C range and the storage temperature shall be -40°C to 70°C. the weight of luminaire shall be min 3kg. The lifetime of the luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self-declaration of ASTM B117 for 500 hours of salt spray test. Photometric data shall be passed on test results from an independent testing lab. All mounting accessories shall be stainless steel (Minimum -316) for all lighting fixtures. All hardwired connections to LED fixture shall be reverse-polarity protected and shall provide high-voltage protection in the event that connections are reversed or shorted during installation. The luminaire should be BIS-certified. The luminaire manufacturer shall provide optical performance, polar diagram and photometric data in various formats including IES files in accordance with IES 79-08. This includes all the required hardware for the successful operation of the luminaire. All the technical parameters of the luminaire need approval from the lighting consultant
Supply installation Testing and Commissinoning Round flood light, 120W, 7655 lumens ±10%, 15° beam ±10%, 3000K ±150K: Supply of exterior-rated architectural floor/wall/Pole mounted, IP66, round flood light complete with antiglare snoot. The power consumption should be not more than 120 watts, minimum system lumen delivered shall be 7655 lumens ±10%, 15° beam angle ±10%, CCT-3000K ±150K. LED from CREE/NICHIA/LUMILED/OSRAM. The housing material should be die-cast aluminum with Electrostatically applied polyester powder coating, The luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses and a clear tempered glass cover. Bracket shall have a locking mechanism to fix and secure the required tilting angle, ±90°. It should have CRI>80, and SDCM≤4. The driver should be integrated AC with PF>0.9 & and THD<20%. Leader cables, jumper cables, and IP68 connectors are included, minimum IK06. The operating temperature should be of -40°C to 50°C range and the storage temperature shall be -40°C to 70°C. the weight of luminaire shall be min 8kg. The lifetime of the luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self-declaration of ASTM B117 for 500 hours of salt spray test. Photometric data shall be passed on test results from an independent testing lab. All mounting accessories shall be stainless steel (Minimum -316) for all lighting fixtures. All hardwired connections to LED fixture shall be reverse-polarity protected and shall provide high-voltage protection in the event that connections are reversed or shorted during installation. The luminaire should be BIS-certified. The luminaire manufacturer shall provide optical performance, polar diagram and photometric data in various formats including IES files in accordance with IES 79-08. This includes all the required hardware for the successful operation of the luminaire. All the technical parameters of the luminaire need approval from the lighting consultant
Supply installation Testing and Commissinoning Round flood light, 50W, 2230 lumens ±10%, 15° beam ±10%, RGBNW: Supply of exterior-rated architectural floor/wall/Pole mounted, IP66, round flood light complete with antiglare snoot. The power consumption should be not more than 50 watts, minimum system lumen delivered shall be 2230 lumens ±10%, 15° beam angle ±10%, CCT-3000K ±150K. LED from CREE/NICHIA/LUMILED/OSRAM. The housing material should be die-cast aluminum with Electrostatically applied polyester powder coating, The luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses and a clear tempered glass cover. Bracket shall have a locking mechanism to fix and secure the required tilting angle, ±90°. It should have CRI>80, and SDCM≤4. The driver should be integrated AC with PF>0.9 & and THD<20%. Leader cables, jumper cables, and IP68 connectors are included, minimum IK06. The operating temperature should be of -40°C to 50°C range and the storage temperature shall be -40°C to 70°C. the weight of luminaire shall be min 3kg. The lifetime of the luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self-declaration of ASTM B117 for 500 hours of salt spray test. Photometric data shall be passed on test results from an independent testing lab. All mounting accessories shall be stainless steel (Minimum -316) for all lighting fixtures. All hardwired connections to LED fixture shall be reverse-polarity protected and shall provide high-voltage protection in the event that connections are reversed or shorted during installation. The luminaire should be BIS-certified. The luminaire manufacturer shall provide optical performance, polar diagram and photometric data in various formats including IES files in accordance with IES 79-08. This includes all the required hardware for the successful operation of the luminaire. All the technical parameters of the luminaire need approval from the lighting consultant
Supply installation Testing and Commissinoning Round flood light, 100W, 4355 lumens ±10%, 15° beam ±10%, RGBNW: Supply of exterior-rated architectural floor/wall/Pole mounted, IP66, round flood light complete with antiglare snoot. The power consumption should be not more than 100 watts, minimum system lumen delivered shall be 4355 lumens ±10%, 15° beam angle ±10%, CCT-RGBNW. LED from CREE/NICHIA/LUMILED/OSRAM. The housing material should be die-cast aluminum with Electrostatically applied polyester powder coating, The luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses and a clear tempered glass cover. Bracket shall have a locking mechanism to fix and secure the required tilting angle, ±90°. It should have CRI>80, and SDCM≤4. The driver should be integrated AC with PF>0.9 & and THD<20%. Leader cables, jumper cables, and IP68 connectors are included, minimum IK06. The operating temperature should be of -40°C to 50°C range and the storage temperature shall be -40°C to 70°C. the weight of luminaire shall be min 3kg. The lifetime of the luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self-declaration of ASTM B117 for 500 hours of salt spray test. Photometric data shall be passed on test results from an independent testing lab. All mounting accessories shall be stainless steel (Minimum -316) for all lighting fixtures. All hardwired connections to LED fixture shall be reverse-polarity protected and shall provide high-voltage protection in the event that connections are reversed or shorted during installation. The luminaire should be BIS-certified. The luminaire manufacturer shall provide optical performance, polar diagram and photometric data in various formats including IES files in accordance with IES 79-08. This includes all the required hardware for the successful operation of the luminaire. All the technical parameters of the luminaire need approval from the lighting consultant
Supply installation Testing and Commissinoning Round flood light, 150W, 6920 lumens ±10%, 15° beam ±10%, RGBNW: Supply of exterior-rated architectural floor/wall/Pole mounted, IP66, round flood light complete with antiglare snoot. The power consumption should be not more than 150 watts, minimum system lumen delivered shall be 6920 lumens ±10%, 15° beam angle ±10%, CCT-RGBNW. LED from CREE/NICHIA/LUMILED/OSRAM. The housing material should be die-cast aluminum with Electrostatically applied polyester powder coating, The luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses and a clear tempered glass cover. Bracket shall have a locking mechanism to fix and secure the required tilting angle, ±90°. It should have CRI>80, and SDCM≤4. The driver should be integrated AC with PF>0.9 & and THD<20%. Leader cables, jumper cables, and IP68 connectors are included, minimum IK06. The operating temperature should be of -40°C to 50°C range and the storage temperature shall be -40°C to 70°C. the weight of luminaire shall be min 8kg. The lifetime of the luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self-declaration of ASTM B117 for 500 hours of salt spray test. Photometric data shall be passed on test results from an independent testing lab. All mounting accessories shall be stainless steel (Minimum -316) for all lighting fixtures. All hardwired connections to LED fixture shall be reverse-polarity protected and shall provide high-voltage protection in the event that connections are reversed or shorted during installation. The luminaire should be BIS-certified. The luminaire manufacturer shall provide optical performance, polar diagram and photometric data in various formats including IES files in accordance with IES 79-08. This includes all the required hardware for the successful operation of the luminaire. All the technical parameters of the luminaire need approval from the lighting consultant
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
technical_564626.pdf
techsummary_564626.pdf
finance_564626.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.