| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.1 LAccepted-Finance | L1 | Accepted-Finance Admitted for reasonability scrutiny | |
| 2 | L2₹7.2 L+₹18,750 (2.66%)Rejected-Finance | L2 | Rejected-Finance other than lowest | |
| 3 | L3₹8.1 L+₹1.0 L (14.8%)Rejected-Finance KG 115 SABIRA MANZIL HBR 2ND STAGE VENKATESH PURAM BANGALORE 560 045 | BENGALURU URBAN | KARNATAKA | 560045 | L3 | Rejected-Finance other than lowest |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
24 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER (SOUTH) BANGALORE
GARRISON ENGINEER (SOUTH) BANGALORE NO 1, ULSOOR ROAD BANGALORE-560 042
AS PER BOQ AND TENDER DOCUMENT
2020_MES_373272_1
GE(S)/B/8436/E8
Open Tender
Civil Works
Item Rate
180 days
BANGALORE
AS PER TENDER DOCUMENT
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER (SOUTH) BANGALORE
₹20,000
Yes
1 Oct 2020
29 Aug 2020
26 Sept 2020
29 Aug 2020
24 Sept 2020
11 Sept 2020
29 Aug 2020 - 7 Sept 2020
60 days
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and getting out in soft/loose soil etc complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick in any type of soil etc complete.all as specified and as directed.
Removing excavated soil to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 M above the starting point all as specified and as directed.
Supply and spread river sand to required width at bottom and top for cable cushioining all as specified and directed. (8cm before laying the cable and 15cm after laying the cable and punned into 18 cm thickness) Note : Punned thickness only shall be measued and paid.
Supply and lay burnt bricks of sub class 'B' laid dry across in trenches for cable protection,locally available best quality,deisgnation 75 all as specified and directed.
M & L for plain cement concrete 1:4;8 type D2 (using 40mm graded stone aggregate) as in foundations filling and mass concrete etc all as specified and directed.
M & L for plain cement concrete 1:2;4 type B-1 (using 20mm graded stone aggregate) as in copings of poles etc including weathering slightly rounded or chamfered angles and throating etc all as specified and directed.
Supply, lay & testing 1100 volts grade XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor of cross sectional area 2 core 6 sq mm of fixing or passing in trenches/ on pole / through pipes including connection with cable glands & lugs etc and testing on completion incl taking out old unserviceable cable complete all as specified and as directed. Note for item Nos 08 to 16 :- Excavation & earth work, sand cushning and bricks,GI protection pipes shall be measured and paid seperately under relevent items of this Sch.
All as per Item No 8 here in before but of size 2 Core 10 Sqmm
All as per Item No 8 here in before but of size 4 Core 16 Sqmm
All as per Item No 8 here in before but of size 3.5 Core 25 Sqmm
All as per Item No 8 here in before but of size 3.5 Core 35 Sqmm
All as per Item No 8 here in before but of size 3.5 Core 70 Sqmm
All as per Item No 8 here in before but of size 3.5 Core 95 Sqmm
All as per Item No 8 here in before but of size 3.5 Core 120 Sqmm
All as per Item No 8 here in before but of size 3.5 Core 300 Sqmm
S & F in repairs galvanized Iron light grade pipe of 40mm dia including fittings for poles/wall including clamps,nut bolts etc for cable protection all as specified and directed
S & F in repairs galvanized Iron medium grade pipe of 40mm dia including fittings etc for cable protection under road/floor/trenches etc all as specified and directed
M & L for LT straight through joint for under ground cable for 3.5/ 4 Core upto 50 sqmm complete all as specified and directed. Make:- Raychem/M-Seal/3-M/Dennison
M & L for LT straight through joint for under ground cable for 3.5 Core 70 to 120 sqmm complete all as specified and directed. Make:- Raychem/M-Seal/3-M/Dennison
M & L for LT straight through joint for under ground cable for 3.5 Core 150 to 300 sqmm complete all as specified and directed. Make:- Raychem/M-Seal/3-M/Dennison
S&F MCCB 4 pole 400 Amps, AC 415 V, 50 Hz adjustable type with breaking capacity 36 KA including taking down unserviceable MCCB and connecting to existing panel board all as specified and as directed.
S&F MCCB 4 pole 200 Amps, AC 415 V, 50 Hz with adjustable type breaking capacity 36 KA including taking down unserviceable MCCB and connecting to existing panel board all as specified and as directed.
S&F MCCB 4 pole 160 Amps, AC 415 V, 50 Hz adjustable type with breaking capacity 36 KA including taking down unserviceable MCCB and connecting to existing panel board all as specified and as directed.
S & F in repairs for MCCB 4 Pole, 415 V, adjustable type, 125 Amps with breaking capacity 16 KA connecting to existing panel board all as specified and directed.
S & F in repairs for MCCB 4 Pole, 415 V, adjustable type, 100 Amps with breaking capacity 16 KA connecting to existing panel board all as specified and directed.
M & L for fabrication, installation, connecting, commissioning and testing of Feeder piller box, outdoor type, factory made of overall dimension 50 x 40 x 30 cm made of 3.15 mm thick CRCA sheet ,FPB openeing on front side, floor mounted on angle iron 40X40X6 mm grouted 15 cm in ground & 30 cm above ground, powder coated suitably ventilated for 3 phase 4 wire 415 volts 50 Hz AC supply including high conductivity copper bus bar of 200 Amp rating mounted on isulator with the provn of one incoming and four no out going cables incl necessary cable glands, cable lugs etc including PCC foundation for fixing FPB box in PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) including taking out old rusted FPB complete all as specified and directed.
M & L for cutting/dismantling of floors /walls/roads etc for laying/passing under ground cables including provision of PCC 1:2;4 type B-2 (using 40mm graded stone aggregate) 100 mm thick in cutted/dismantled portion and making good the surface as per existing after laying/passing the cables etc all as specified and directed.
M&L for earthing complete with GI earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth plate not less than 2.25 Metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanished iron strip 25x4 mm by means of bolts, nuts check and washers of GI or steel all as shown in electrical plate No. 3 of SSR Pt -I connected to earthing test point all as specified or indicated including GI pipe 15 mm dia light grade for earth wire protection, necessary excavation, earth work in any type of soil, PCC (1:3:6) type C-1 (with 20mm graded stone aggregate),chamber and 50mm thick precast RCC (1:2:4) cover slab re-inforced with XPM Jalli including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed .
S & F in repairs analog street light timer (with battery back up) 1 mod DIN 1P module 24 hours program,programmable every 15 min, back up of 100 hours current capacity 16 Amp with 1 change over (1CO) etc complete all as specified and as directed Make:-Indoasian Cat No TA916422 or equivalent in legrand/sneider/havells.
S & F in repairs 3 pole contactor suitable for street light controlling with nominal current rating 32 Amp 415V etc complete all as specified and as directed Make:-Indoasian Cat No 850047 or equivalent in legrand/sneider/havells.
B M Electricals
GS TRADERS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .