Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.9 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹19.2 L+₹55,711 (2.98%)Rejected-Finance | L2 | Rejected-Finance Quoted other than lowest rate | |
| 3 | L3₹22.7 L+₹4.0 L (21.6%)Rejected-Finance | L3 | Rejected-Finance Quoted other than lowest rate | |
| 4 | L4₹23.7 L+₹5.1 L (27.2%)Rejected-Finance | L4 | Rejected-Finance Quoted other than lowest rate | |
| 5 | L5₹24.2 L+₹5.5 L (29.4%)Rejected-Finance | L5 | Rejected-Finance Quoted other than lowest rate |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
10 Jun 2021, 6:00 pmClosed
Shri Sachin H Chavan IDSE
GE NORTH BATHINDA MIL STN-151004
CERTAIN REPAIR REPLACEMENT AND IMPROVEMENT OF INTERNAL POINT WIRING SUB MAIN WIRING DBs FITTING AND FIXTURES IN SHIVAJI AND PEERU SINGH ENCLAVE UNDER GE NORTH BATHINDA AT BATHINDA MIL STN
2021_MES_442968_1
8936/NIT-15/21-22
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE NORTH BATHINDA MIL STN
D Class and category b i
8 documents required · 8 mandatory
₹500
GE NORTH BATHINDA
₹80,000
Yes
1 Jul 2021
15 May 2021
12 Jun 2021
15 May 2021
10 Jun 2021
29 May 2021
15 May 2021 - 25 May 2021
Amount
SCHEDULE 'A' E/M Works
Taking down carefully unserviceable copper/aluminum point wiring from existing conduit pipe (light, fan, socket or power point) complete including removal of unserviceable fittings such as hylum sheet, switches, ceiling rose, pendent holder, sockets, regulator, sunken boxes etc but except concealed conduit, including making good the disturbed surface of walls, floors, ceilings etc. to match with the adjoining work, complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Point wiring complete with 1.5 Sqmm (nominal cross section area) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through existing concealed PVC rigid conduit, but new MS sunken box of suitable size, 3mm thick bakelite plastic laminated sheet for mounting of switches and socket, fan regulator, wiring for light /fan/bell point controlled by one switch, including provn of 1.5 Sqmm FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) to matching with existing surfaces complete all as specified and as directed by Engineer-in-charge. complete all as specified and as directed by Engineer-in-charge. (switches, sockets, fan regulator etc. shall be measured and paid separately under appropriate item of BOQ).
All as per above Srl item No. 2 but for one socket outlet 5/6 Amps point controlled by one switch (on same board) complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ).
All as per above Srl item No. 2 but for one socket outlet 5/6 Amps point controlled by one switch (on indipendent board and not below the any other switch board) complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ).
All as per above Srl item No. 2 but for one light point controlled by two, two way switches complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ).
All as per above Srl item No. 2 but for bell/buzzer point complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ).
Material and labour for Point wiring complete with 2.5 Sqmm (nominal cross section area) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through existing concealed PVC rigid conduit, but new MS sunken box of suitable size, 3mm thick bakelite plastic laminated hylem sheet for mounting of switches and socket, for one socket outlet 15/16 Amps point controlled by one switch (on indipendent board), including provn of 2.5 Sqmm FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) to matching with existing surfaces complete all as specified and as directed by Engineer-in-charge. complete all as specified and as directed by Engineer-in-charge. (switches, sockets etc. shall be measured and paid separately under appropriate item of BOQ).
Taking down carefully unserviceable copper/aluminum point wiring (light, fan, socket or power point) complete including fittings such as hylum sheet, switches, ceiling rose, pendent holder, sockets, regulator including rusted/broken concealed conduit, junction and sunken boxes etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for concealed Point wiring complete with 1.5 Sqmm (nominal cross section area) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC rigid conduit 20mm dia (medium duty) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction box, MS sunken box of suitable size, 3mm thick bakelite plastic laminated hylem sheet for mounting of switches and socket, fan regulator, wiring for light /fan/ bell point controlled by one switch (on indipendent board), including provn of 1.5 Sqmm FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) to matching with existing surfaces complete all as specified and as directed by Engineer-in-charge. (switches, sockets, fan regulator etc. shall be measured and paid separately under appropriate item of BOQ).
All as per above Srl item No. 9 but for one socket out let 5/6 Amps point controlled by one switch (on same board) complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ).
All as per above Srl item No. 9 but for one socket out let 5/6 Amps point controlled by one switch (on indipendent board and not below the any other switch board) complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ).
All as per above Srl item No. 9 but for one light point controlled by two, two way switches complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ).
All as per above Srl item No. 9 but for bell/buzzer point complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ).
Material and labour for concealed Point wiring complete with 2.5 Sqmm (nominal cross section area) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC rigid conduit 20mm dia (medium duty) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction box, MS sunken box of suitable size, 3mm thick bakelite plastic laminated hylem sheet for mounting of switches and socket, wiring for one socket out let 15/16 Amps point controlled by one switch (on indipendent board) , including provn of 2.5 Sqmm FRLSH PVC insulated solid copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) to matching with existing surfaces complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ).
Supply and fixing switch piano flush type (ISI marked), 5/6Amps, single pole, one way fixed on laminated sheet complete all as specified and as directed by Engineer-in-charge. (laminated sheet shall be measured and paid in point wiring item of BOQ).
Supply and fixing Socket outlet multipurpose type (ISI marked), 2 in 1, 3/5 pin 5/6 Amp, flush type fixed on laminated sheet complete all as specified and as directed by Engineer-in-charge. (laminated sheet shall be included in point wiring item of BOQ).
Supply and fixing switch piano flush type (ISI marked), 15/16Amps, single pole, one way complete all as specified and as directed by Engineer-in-charge. (laminated sheet shall be included in point wiring item of BOQ).
Supply and fixing Socket outlet multipurpose type (ISI marked), 2 in 1, 3/5 pin 15/16 Amp, flush type fixed on laminated sheet complete all as specified and as directed by Engineer-in-charge. (laminated sheet shall be included in point wiring item of BOQ).
Supply and fixing switch piano flush type (ISI marked), 5/6Amps, single pole, two way fixed on laminated sheet complete all as specified and as directed by Engineer-in-charge. (laminated sheet shall be included in point wiring item of BOQ).
Supply and fixing switch piano flush type (ISI marked), Bell Push, 5/6Amps, single pole, one way fixed on laminated sheet complete all as specified and as directed by Engineer-in-charge. (laminated sheet shall be measured and paid in point wiring item of BOQ).
Supply and fixing stepped type (1-4), electronic Fan regulator (one module), 100 watt, 250 volts, fixed on laminated sheet suitable for ceiling fan complete all as specified by Engineer-in-charge. (laminated sheet shall be measured and paid in point wiring item of BOQ).
Supply and fixing ceiling rose (ISI marked) surface type polycarbonate isolated body two to three terminal, topline series 20x50mm, 6 Amp, 250 volts, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement electric calling Bell Ding Dong type, AC 230 Volts single pole including making elctric connection and testing, complete all as specified and as directed by Engr-in-charge.
Supply and fixing in repair, Lamp holder of PVC/Polycarbonate type with back plate suitable for batten fitting including 9 watt LED bulb complete all as specified and as directed by Engr-in-charge.
Supply and fixing in replacement wall mounted LED Batten T-8 Retro LED 18/20 watt (100 lumens per watt), appx 4 feet long, pre wired including LED tube light with in built driver, not less than 6000K, complete fitting and all other accessories fitting arrangements including electric connection including taking down old unserviceable light fittings any type at any site as directed complete all as specified and as directed by Engineer-in-Charge. Make - Cat part No LT8-20-865-2 and DMLN1LT8-16 of Crompton /BLRB 18W CWc and BLRB-DB 118 of Bajaj / PHOTONULTRA 1213T8SSTL18WLED865SPC and REGALBATTENT 8UPTO1X22WSSBSWH of Havells/ HLTLD-04-20-CW-PC and HLCB-01-1XT of Halonix
Supply and fixing in replacement LED mirror light fitting of 07 watt, 6000K, linear & compact with decorative grey end caps, polycarbonate body and ribbed opal diffuser complete including 07 watt tube rod all as Model No LCL- 07- CDL of Crompton with 07 watt rod or equivalent model of approved make from list of make attached in tender documents including connecting to electric point by using PVC insulated twin core copper conductor cable of suitable size including taking down old existing light fitting complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement Wall Mount Light fixture in cylindrical/doom profile made up of polycarbonate suitable for LED Lamp and including LED 7/9 Watt lamp (100 lumens per watt), complete fitting with lamp and all other fixing accessories including electric connection including taking down old unserviceable light fittings any type at any site complete all as specified and as directed by Engineer-in-Charge. Make :- Cat Part No. DCWL15DF of Crompton or equivalent to Havells
Supply and fixing energy efficient LED street light fitting of 25 Watt with PDC aluminium body and clear glass with lens for wide beam distribution, top maintainable type with IP 66 degree of protection, PF>0.95 with voltage range 140 to 270 Volt, fitting should be provided with inbuilt 5 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fitting including 25 watt LED lamp with GI brackrt-01 No, MS clamp-02 Nos suitable for walls/ columns and making electrical connection with providing of 1.50 metre long twin core round copper conductor cable of suitable size and testing complete all as per SYSKA cat part No. SSK-SLF-CF-25W-WL or equivalent model of any make given in Appx 'B', Cat Part No. as approved by GE complete all as specified including taking down old unserviceable existing street light fitting of any type and capacity from pole along with accessories.
Supply and fixing in replacement LED Post top lantern decorative oriental design 20 watt, IP65, Glare-free and better uniformity, with decorative clear opal acrylic diffuser, complete fitting with all accessories and LED lamp, fixing on existing GI pipe system or as directed by Engineer-in-charge including all electric connections, including taking down old unserviceable fitting any type complete all as specified and as directed by Engineer-in-charge. Make :- LPTH 20 CDL of Cropmton or equivalent make mentioned in Appendix 'A' of PSS-II
Material and labour for concealed sub main wiring with 4 Sqmm single core (Two run) FRLSH PVC insulated multistrand copper conductor drawn through existing PVC conduit, independent circuit from DB and including one run 4 Sqmm FRLSH PVC insulated unsheathed multi strand copper conductor continues as earth wire connected to earth dolly etc. including taking out old sub main wiring of any conductor any size from conduit and making good disturbed surfaces of walls as per original complete all as specified and as directed by Engineer-in-charge. Note :-Three run of 4 sqmm copper wire shall be measured as one RM length for payment.
Material and labour for concealed sub main wiring with 6 Sqmm single core (Two run) FRLSH PVC insulated multistrand copper conductor drawn through existing PVC conduit, independent circuit from DB and including one run 6 Sqmm FRLSH PVC insulated unsheathed multi strand copper conductor continues as earth wire connected to earth dolly etc. including taking out old sub main wiring of any conductor any size from conduit and making good disturbed surfaces of walls as per original complete all as specified and as directed by Engineer-in-charge. Note :-Three run of 6 sqmm copper wire shall be measured as one RM length for payment.
Material and labour for concealed sub main wiring with 4 Sqmm single core (Two run) FRLSH PVC insulated multistrand copper conductor drawn through and including PVC conduit 20mm dia (medium quality ISI marked), on independent circuit from DB and including one run 4 Sqmm FRLSH PVC insulated unsheathed multi strand copper conductor continues as earth wire connected to earth dolly etc. including all fitting arrangement i.e. PVC clamp, rawl plug, screw, terminal/junction box, tee, bend etc. and including cutting of chases in wall, taking out old sub main wiring of any conductor any size from conduit and taking down old unserviceable conduit with fittings, and making good disturbed surfaces of walls as per original complete all as specified and as directed by Engineer-in-charge. Note :-Three run of 4 sqmm copper wire and one run conduit shall be measured as one RM length for payment.
Material and labour for concealed sub main wiring with 6 Sqmm single core (Two run) FRLSH PVC insulated multistrand copper conductor drawn through and including PVC conduit 20mm dia (medium quality ISI marked), on independent circuit from DB and including one run 6 Sqmm FRLSH PVC insulated unsheathed multi strand copper conductor continues as earth wire connected to earth dolly etc. including all fitting arrangement i.e. PVC clamp, rawl plug, screw, terminal/junction box, tee, bend etc. and including cutting of chases in wall, taking out old sub main wiring of any conductor any size from conduit and taking down old unserviceable conduit with fittings, and making good disturbed surfaces of walls as per original complete all as specified and as directed by Engineer-in-charge. Note :-Three run of 6 sqmm copper wire and one run conduit shall be measured as one RM length for payment.
Supply and fixing in replacement (concealed in wall or as directed) factory made DB (made out of CRCA sheet) SPN, 08 Way (08 modules) 230/240V, double door, earth bar, copper bus bar and neutral link, protection class IP-43 suitable for mounting MCB/Isolator, conforming to IS-8623, BS-5484 dust and vermin proof, including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB’s shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing in replacement (concealed in wall or as directed) factory made DB (made out of CRCA sheet) SPN, 12 Way (12 modules) 230/240V, double door, earth bar, copper bus bar and neutral link, protection class IP-43 suitable for mounting MCB/Isolator, conforming to IS-8623, BS-5484 dust and vermin proof, including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB’s shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing in replacement (concealed in wall or as directed) factory made DB (made out of CRCA sheet) TPN, 4 Way (8+12) 415V, double door, earth bar, copper bus bar and neutral link, protection class IP-43 suitable for provision to mount FP MCB/Isolator (incomer ) and SP MCB's outgoing, conforming to IS-8623, BS-5484 dust and vermin proof, including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB’s shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing (concealed in wall or as directed) single pole and neutral sheet metal enclosure (AC Box) with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amps, 240 volts, AC supply including taking down old unserviceable enclosure complete all as specified and directed by Engineer-in-Charge.
Supply and fixing MCB ‘C’ curve suitable for 230 volts AC supply, 06 to 32 Amps, SP with over load and short circuit protection and rupturing capacity not less than 10 KA, including taking down old unserviceable MCB SP, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing MCB ‘C’ curve suitable for 230 volts AC supply, 40 Amps, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA, including taking down old unserviceable MCB SPN, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing MCB ‘C’ curve suitable for 415 volts AC supply, 63 Amps, TPN and rupturing capacity not less than 10 KA, including taking down old unserviceable MCB TPN, complete all as specified and as directed by Engineer-in-charge.
Dismentling & Taking down carefully existing panel/meter board and electric/electronic meters, deposite the same meters safely to E/M store yard for refixing complete all as specified and as directed by Engineer-in-charge.
Supply, installation, testing & commisioning of wall mounted indoor LT panel board protection class IP65, 415-433V made out of 2.0 mm thick RAL 7032/7035 coated CRCA steel, dust and vermin proof, double door complete prewired, with locking arrangements and hanging bracket suitable for fixing on wall, including painting with powder coated paint over a coat of redoxide zinc crome primer complete incl necessary internal wiring for MCBs and electric meter and suitable opening for cable entry with gland comprising of the following:- (i) Incomer 100 Amps 4 pole MCCB as per existing size and type (ii) R Y B phase Indicating lamps - 01 Set (set of three) (iii) insulated Copper Busbars 200A rating - 04 Nos (iv) 63A DP MCBs C Curve-06 Nos(For DUs meters) (v) 10A DP MCB C Curve-01 No (For staircase lighting) (vi) Provision of digital Voltmeter suitable for 0-500 Volts AC (vii) Provisional arrangement for energy meters with transparent acrylic sheet with separate locking arrangements-06 Nos (viii) Refixing and connecting energy meters and including necessary connection. Note :- MCCBs, MCBs are paid separately under appropriate item of BOQ
Supply only MCCB of capacity 100 Amp, FP, 415 volt, short circuit breaking capacity not less than 25KA , thermal magnetic trip, setting 80-100%, Icu-100% Ics confirming to IEC-947, IS-13947, including thimbles, nuts, bolts, washers etc , MCCB fixing in panel (new or old) including making incoming, outgoing connections complete all as specified and as directed by Engineer-in-charge . Note:- (Rate of fixing arrangements included in item No. 42)
Supply only MCB SPN 63 A 415V complete all as specified and as directed by Engineer-in-charge . Note:- (Rate of fixing arrangements included in item No. 42)
Supply only MCB SPN 10 A 215 V complete all as specified and as directed by Engineer-in-charge . Note:- (Rate of fixing arrangements included in item No. 42)
Repair /maint of u/s switch board /distribution board unscrewing from its existing position & checking all connection of board and taking down all unserviceable items of board like switch, socket, fan regulator and petty repairs (if required) and making serviceable the switch point complete all as specified and as directed by Engineer in charge. Note:- Hylum sheets,Switches, sockets and fan regulator shall be measured and paid seprately under appropriate item of BOQ
Supply and fixing in replacement of 3mm thick phenolic sheet 4 inch x 4 inch including suitable machine screws as required, including taking down old unserviceable sheet and un screwing serviceable / unserviceable switch / socket / regulator etc and serviceable switch / socket / regulator etc shall be refix after proper cleaning on new sheet, at any site as per daily complaint basis complete all as specified and as directed by Engineer-in-Charge. Note :- New switches, sockets, regulator etc. if required in replacement with unserviceable the same shall be measured and paid separately under appropriate item of BOQ as supply only and labour for fixing shall be included in unit rate of this item).
Supply and fixing in replacement of 3mm thick phenolic sheet 7 inch x 4 inch including suitable machine screws as required, including taking down old unserviceable sheet and un screwing serviceable / unserviceable switch / socket / regulator etc and serviceable switch / socket / regulator etc shall be re fix after proper cleaning on new sheet, at any site as per daily complaint basis complete all as specified and as directed by Engineer-in-Charge. Note :- New switches, sockets, regulator etc. if required in replacement with unserviceable the same shall be measured and paid separately under appropriate item of BOQ as supply only and labour for fixing shall be included in unit rate of this item).
Supply and fixing in replacement of 3mm thick phenolic sheet 8 inch x 10 inch including suitable machine screws as required, including taking down old unserviceable sheet and un screwing serviceable / unserviceable switch / socket / regulator etc and serviceable switch / socket / regulator etc shall be re fix after proper cleaning on new sheet, at any site as per daily complaint basis complete all as specified and as directed by Engineer-in-Charge. Note :- New switches, sockets, regulator etc. if required in replacement with unserviceable the same shall be measured and paid separately under appropriate item of BOQ as supply only and labour for fixing shall be included in unit rate of this item).
Supply and fixing in replacement of 3mm thick phenolic sheet 10 inch x 12 inch including suitable machine screws as required, including taking down old unserviceable sheet and un screwing serviceable / unserviceable switch / socket / regulator etc and serviceable switch / socket / regulator etc shall be re fix after proper cleaning on new sheet, at any site as per daily complaint basis complete all as specified and as directed by Engineer-in-Charge. Note :- New switches, sockets, regulator etc. if required in replacement with unserviceable the same shall be measured and paid separately under appropriate item of BOQ as supply only and labour for fixing shall be included in unit rate of this item).
Supply only switch piano flush type, 5/6Amps, 250 volts, one way fixed on existing sheet complete all as specified and as directed by Engineer-in-charge.
Supply only switch piano flush type, 15/16Amps, 250 volts, one way fixed on existing sheet complete all as specified and as directed by Engineer-in-charge.
Supply only two way switch piano flush type, 5/6Amps, 250 volts, single pole, one way fixed on existing sheet complete all as specified and as directed by Engineer-in-charge.
Supply only socket outlet multipurpose flush type, 3/5pin, 5/6Amps, 250 volts, fixed on existing sheet complete all as specified and as directed by Engineer-in-charge.
Supply only socket outlet multipurpose flush type, 2 in 1, 5/6pin, 15/16Amps, 250 volts, fixed on existing sheet complete all as specified and as directed by Engineer-in-charge.
Supply and fixing Bell push, flush type, 5 amp flush type fixed on existing sheet complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement stepped type (1-4), electronic Fan regulator (two module), 100 watt, 250 volts, in existing switch board including making elctric connection and testing, including screw for fixing as required, fixing at any site as directed complete all as specified and as directed by Engineer-in-charge.
Supply and fixing Retro LED 20 watt tube only appx 4 ' long 6000k min 100 lumens per watt with inbuilt driver to be fixed in to existing batten in replacement of tube 34/40 watt including taking down of existing tube rod complete all as specified and as directed. Make:- Cat part No LT-8-20-865-2 of Crompton /BLRB 18W of Bajaj / Cat part No : PHOTONULTRA1213T8SSTL18WLED865SPC of Havells.
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including earth continuity GI wire 4 mm (upto test point from earth plate i.e. 7.5m min) by means of GI bolts/nuts/washers and including protected by 15mm dia GI light grade protection pipe from earth plate to test point, including making of test point made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos- 8mm dia 25mm long hex head screw. Earth plate shall be surrounded by packed layer of char coal/coke & salt all around bottom and top with alternative layer. 20mm GI light grade pipe for watering (should be 10cm above GL) and including socket, plug, funnel, wire mesh, CI cover 10mm thick hanged to CFI frame, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate), including necessary form work, excavation and earth work in any type of soil , returning filling and disposal of surplus soil to a distance not exceeding 50m, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and and as directed by Engineer-in-charge, including taking out/dismantling old unserviceable earthing system. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
NASIB ENGINEERS AND CONSTRUCTION
Aman Enterprises
G N CONSTRUCTIONS
M/s DHEERAJ JAIN CONSTRUCTION COMPANY
M/s Kataria Construction Company
PREM ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .