RENEWAL/REPLACEMENT OF BER SUMMER AND COOLING APPLIANCES AND PUMPS IN DOMESTIC AREA AT AFS GWALIOR
2026_MES_799542_1
86081
Open Tender
Civil Works - Others
Item Rate
180 days
GE (AF) ADM AREA
As per NIT and Tender documents
8 documents required · 8 mandatory
₹500
GE (AF) Adm Area
₹22,000
Yes
19 Nov 2026
19 Nov 2026
16 Dec 2026
19 Nov 2026
10 Dec 2026
4 Dec 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Disconnecting the electrical cable connections of motor and water supply system to the pump set and taking out motor and pump set by disconnecting both motor and pump mechanically disconnecting suction and delivery pipe connections from multi stage pump 40 HP capacity, Dismantling the pump sets from foundation including starter complete and transporting the same to the MES store yard complete all as specified and as directed by Engineer-in-charge. | 2 | Each Job | - | - |
| 2 | M&L for PCC (1:3:6) type C2 (using 40mm graded stone aggregate) for anchorage blocks for pipe line/suitable for Base frame of pump set/hard standings/PCC foundation etc including necessary from work where required,complete alongwith grouting 06 nos bolts 350 mm x 30 mm including demolition of existing PCC foundation complete all as specified and as directed by Engineer-in-charge.
Note :- Rate for 06 Nos bolts shall be deemed to be included with the quoted rate. | 4 | Cum | - | - |
| 3 | M&L for Earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to galvanised iron earth strip 25 x4 mm up to test point with suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1, precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including medium grade GI watering pipe 25mm bore with funnel wire mesh and medium grade GI earth wire protection pipe 40mm bore up to main board complete as shown in electrical plate no 3 of MES schedule Part-I 2009, connected to earthing testing point including taking out existing unsv earthing complete all as specified and testing on completion complete all as specified and directed by Engr-in-charge. Note : The units rate includes the cost of excavation & earth work in any type of soil charcoal & salt in ultimate layers, 25mm GI Pipe (light grade) for watering 50mm GI protection pipe (light grade) funnel wire mesh PCC chamber in PCC 1:3:6 type C-1 cast iron frame and 40mm thick RCC cover for pit etc & no extra payment will be made complete all as specified and as directed by Engineer-in-charge. | 2 | Each | - | - |
| 4 | Supply, laying, jointing and testing in repair PVC insulated cable 1100 volt grade with multi stranded, single core copper 95 Sqmm, including making electrical connection from main panel to starter and starter to motor in pieces of suitable length as per site requirement duly fixed with suitable size of coper lugs/thimbles complete all as specified and as directed by Engineer-in-charge.
Make :- Havells/Polycab/Grandlay/Gloster/Finolex | 40 | RM | - | - |
| 5 | Supply, installation, testing and commission of centrifugal pump horizontal spindle, capacity 40HP horizontal/radial split casing and suction, multi stage having capacity of 50 m3/hr at a head 25 meter suitable for nominal speed 1485 RPM for lifting treated water with brass impeller, shaft made of SS 410 bearing, neck ring and bush made of LG2 bronze, shaft sleeves, nuts etc , directly coupled with suitable capacity of electric motor (motor shall be TEFC, sq cage, 50 Hz + 5 %, 415 V + 10 % Class F insulation, Ambient Temp, 3 phase, IP-55, IS-325 with up to date amendments) . Both pump and motor shall be mounted on and including a common steel base frame, assembled by the OEM of the pump itself and not by any authorized dealer /workshop/rep concern etc incl reconnecting the existing suction and delivery pipe lines including material and labour for any modification to existing pipe line connection if required for proper fixing new pumping set all as specified and complete all as per manufacturer's instructions. The quoted rate shall be inclusive of starter Fully Automatic Star Delta Starters 415V,Conforms to Standard IEC 60947-1/IS, Powe 40 HP,Relay Range (A) 36 - 50A,Rated Coil Voltage 240V,Rated Voltage 415V,Frequency 50 Hz ,Dimensions (LxWxH) 435mm x 335mm x 475mm complete all as specified and as directed by Engineer-in-charge.
Make: Kirloskar/Beacon/KSB/Mather & Plant/Grundfos/WASP/ITT
Make of star delta starter :- Havells/ABB/C&S/Indo Asian/Crompton/L&T/Schneider | 2 | Each | - | - |
| 6 | Disconnecting the existing non functional submersible pump set from site by dismantling existing CI bend from non return valve and removing and lifting out submersible pump set of any description and capacity & in any position, along with existing column pipe 80/50mm Dia and existing submersible cable of any size from the bore well 200/150mm bore (approximately 40 mtr depth of pump set from GL) complete all as specified and as directed by Engineer-in-charge.
NOTE: 1. Contractor shall take proper precautions while lifting out and removing pump set from bore well so as to avoid any damage to column pipe and submersible cable. All necessary T&P and equipment's required for lifting out pump set etc shall be arranged by the contractor at his own cost | 6 | Each Job | - | - |
| 7 | Lowering down of the submersible pump set of any description and any capacity & in any position, in bore well along with column pipe 80/50mm Dia and submersible cable of any size (approximately 40 mtr depth of pump set from GL) complete all as specified and as directed by Engineer-in-charge including making necessary electric connections & testing the pump set after lowering.
NOTE: 1. Contractor shall take proper precautions while lowering pump set in bore well so as to avoid any damage to column pipe and submersible cable. All necessary T&P and equipment's required for lifting out pump set etc shall be arranged by the contractor at his own cost. 2. Rates quoted by the contractor for the above item includes the cost of assembling & connecting pump set to column pipes & assembling, jointing and fixing column pipes/pump sets/submersible cable and making necessary connections and including reconnecting water supply system. The required materials like column pipes /submersible cable shall be measured and paid for separately under appropriate item of Schedule `A'.
3. The Submersible column pipe and submersible cable dismantling there in before will be reused with no extra cost to the calcution, | 6 | Each Job | - | - |
| 8 | Supply only 6 Sqmm, 3 Core, flat submersible Cable, PVC insulated, PVC sheathed with multi-stranded copper conductors, 1100 Volt grade, complete all as specified and directed by Engineer-in-Charge.
Make :- Havells/Polycab/Grandlay/Gloster/Finolex | 355 | RM | - | - |
| 9 | Material & labour for water proof joint of submersible cable 3 core of any size using fine rubber and M Seal etc all as directed by Engineer -in-Charge.
Note:- 1. Taking out of cable shall be included in srl item No. 6. | 16 | Each | - | - |
| 10 | S&F Submersible Pumping sets,electric driven, supply and Install complete 05 HP 10 stage,183 LPM @ 61 M Head and inclusive of Three Phase Fully Automatic Star Delta Starters, Model Name/Number MU-G10 Power 3HP -10HP Relay Range (A) 13 - 21A,Rated Coil Voltage 240V,Rated Voltage 415V,Frequency 50 Hz complete all as specified and as directed by Engineer-in-charge.
Make :- MU-G10 of L&T or equvalent make/Model of Havells/ABB/Legrand/Schneider. | 1 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.36 MB
Tender86081.pdf
Tender Documents • 1.04 MB
BOQ_897073.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .