Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹8.2 LAccepted-AOC DEVERTHA NO 1 SHAHGANJ AGRA | AGRA | AGRA | UTTAR PRADESH | 1 | Accepted-AOC Being lowest | |
| 2 | 2₹9.3 L+₹77,032 (9.02%)Rejected-Finance 131 SHINGANAPUR ROAD KOLKI KOLKI SATARA MAHARASHTRA 415523 | SATARA | MAHARASHTRA | 415523 | 2 | Rejected-Finance Not being lowest | |
| 3 | 3₹9.3 L+₹80,645 (9.44%)Rejected-Finance | 3 | Rejected-Finance Not being lowest |
Tender Value
₹9.6 L
EMD Value
₹19,180
Closing Date
27 Sept 2023, 6:00 pmClosed
HQ CWe Agra
112, Taj Road, Agra Cantt
SPL REPAIR TO CENTRAL AC PLANT OF OFFR MESS HQ 50 (I) PARA BDE UNDER GE (EAST) AGRA
2023_MES_616384_1
84290/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Agra
MES contractors enlisted in Class E category c(i) for unenlisted contractors meeting the enlistment criteria corresponding to value class and category of work
8 documents required · 8 mandatory
₹500
GE East Agra
₹19,180
Yes
3 Nov 2023
30 Aug 2023
4 Oct 2023
30 Aug 2023
27 Sept 2023
13 Sept 2023
30 Aug 2023 - 6 Sept 2023
Amount
Disconnecting water connections to the condenser & chiller of package/central A/C plant of 60 TR by dismantling the both end cover of condenser. Descaling the condenser of compressors with dilute sulphuric acid and flushing/cleaning with brush and water and re-fixing the side cover with new gasket nut / bolts and detect leakage all as specified and directed. Note : Dilute sulphuric acid for descaling is deemed to be included in the quoted rates.
Disconnecting/Isolating the compressor from the system by putting plates to the suction and discharge valve opening of the compressor. Dismatling the compressor completely by taking down the crank shaft. Removing unserviceable internal parts cleaning overhauling complete renewal of worn out parts such as suction reed, discharge reed, cylinder liners, loading/unloading system of compressor, washers, nut bolts, gaskets shaft seal, "O" rings, cutting, metalizing, grinding, balancing the crank shaft and reassembling the compressor including changing the compressor oil, leak testing with nitrogen, repairing leakages and charging R-22, gas, testing/comissioning complete for following compressor make Accel sabro/Kirloskar, complete all as specified and directed. Note : R-22 gas,spare parts, compressor oil shall be measured and paid separately under respective items and all other minor items costing less than Rs 500 shall be deemed to be included in the above item rate.The rates for fixing of the following items shall be deemed to be included in the above quoted rate.
(a) Crank shaft and connecting rods
(b) Crank shaft bush
(c) suction reed
(d) Discharge reed
(e) Ring for piston assembly
(f) Piston gudgeon pin with locks
(g) Suction spring
(h) Discharge spring
(j) Gasket set complete
(k) Pump kit for oil assembly
(l) Micro processor card
(m) Piston assembly
(n) Liner assembly
(o) Loading & unloading assembly
Supply and filling of R-22 Gas in central A/C plants complete all as specified and directed.
Supply and fillling compressor oil suitable for central air conditioning plants compressor and taking out old dirty compressor oil, cleaning the crank case and oil filter complete all as specified and directed.
S&F in renewal of cooling tower fan motor of capacity 3.0 HP 3 phase 415 Volt 1395 RPM alongwith long shaft and locking accessories as per existing model / sample suitable for cooling tower of Central AC palnt and duly fixed on existing system and making electrical connection incl takking down complete all as specified and directed.
Supply,installation,testing and commissioning of 10 HP monoblock pump with head range of 28-52 metre and suction and delivery size of 100 mm suitable for 415 V 3 phase supply including all PCC works reqd for its foundation and all other necessary connection complete all as specified and directed.
Supply,installation,testing and commissioning of 12.5HP monoblock pump with head range of 34-62metre and suction and delivery size of 100 mm suitable for 415 V 3 phase supply including all PCC works reqd for its foundation and all other necessary connection complete all as specified and directed.
S&Fin renewal of PVC fills of size 600x300x150 mm suitable for Cooling towers AC plants 10/60/75 TR complete all as specified and directed.
S&F in renewal of Cooling towers louvers suitable size as per existing and suitable for 10/60/75 TR AC plants complete all as specified and directed.
Supply, installation, testing and commissioning in renewal of floor mounted indoor type LT panel, factory made, dust and vermin proof fabricated out of 2 mm thick MS sheet complete with openable shutter in front having proper locking arrangement, fully compartment wise with form 4 (b) separation, duly powder coated grey paint and including 400 Amps, 4 pole copper busbar mounted on epoxy insulator, suitable for 3 phase, 415 volts, 50 Hz AC supply including control wiring to panel with suitable size of PVC insulated and sheathed copper cable, and connecting outgoing MCB / MCCB with outgoing LT cables etc including necessary fixing arrangement on wall in all respect and comprising of following complete all as specified and directed : (a) Incomer MCCB 4 pole, 250 Amp, 25KA ICS=100 % ICU with adjustable thermal settings - 01 No (b) Outgoing MCCB 4 pole 160 Amp,ICU=16 KA ICS=100 % ICU with adjustable thermal settings-02 Nos & MCCB 4 pole 100 Amps ICU=16 KA, ICS=100 % ICU -01 Nos (c ) Digital Multifunctional Meter- 01 No (d) Single Phase Preventor- 01 No (e) Phase sequence controller - 01 No (f) LED Indicator lamps -01 set (R,Y,B) (g) Star delta starter fully automatic suitable for Monoblock pumpSet 10 to 12.5 HP-04 Nos & DOL starter for 3 HP Cooling tower fan motor-01 Nos.
Supply & fixing in renewal of MS pipe heavy duty with flanged ends of diameter 100 mm with all connected parts and accessories reqd for its jointing all as specified and directed.
S&F in renewal , testing out unserviceable/ defected expansion valve assembly as per existing type / sample suitable using for AC plant of capacity 75 TR/60 TR and duly fixed with existing refrigent system with the help of any method including checking and testing on full load complete all as specified & directed.
S&F in renewal of temperature gauge /meter (Thermometer) of any description and in any position complete all as specified & directed.
S&F in renewal of water pressure gauge of range 0 to 300 PSI with100mm dia, duly fixed with suitable size of stainless steel pipe and control valve and fixed on existing position of plant complete all as specified & directed.
S&F in renewal power contactor suitable using for micro panel 3 pole, 415 volt , 50 HZ, 85A current rating, fixed on existing position of panel board and making electric connection of suitable size of wire complete all as specified and directed.
M&L for renewal of non freezing compressor oil M Carate type ISI mark suitable for central type AC plant compressor including cleaning of unwanted leakage oils, silt ,dust etc complete all as specified and directed.
S&F in renewal of 100 mm bore of butter fly valve/ hand shut down stop valve as per existing type /sample made of cast iron body with chromium plated stainless steel shaft & disc of ductile iron epoxy coated including duly fixed with existing pipe line sysem with the help of jointing cutting, welding , nuts bolt & washer ,with flanges, etc complete of different sizes complete all as specified & directed.
Repairs / maint and adjustment of dampers in AC duct for equal air flow pressure in the duct duly opening of duct for necessary required working pressure in condition room including arrangement for testing of velocity pressure test at in and out flow of air cleaning of air filters complete all as specified and directed.
M&L for renewal of by new one insulation of chiller & its connected pipe lines and expension tank with using 9 mm thick puff insulation covered with aluminium lining and made to existing shape and size & its parts of any description and in any position complete all as specified and directed.
Supply, installation, testing and commissioning in renewal of wall mounted indoor type LT panel, factory made, dust and vermin proof fabricated out of 2 mm thick MS sheet complete with openable shutter in front having proper locking arrangement fully compartment wise with 4 (b) separation , duly powder coated grey paint and including 400 Amps, 4 pole copper busbar mounted on epoxy insulator, suitable for 3 phase, 415 volts, 50 Hz AC supply including control wiring to panel with suitable size of PVC insulated and sheathed copper cable, and connecting outgoing MCB / MCCB with outgoing LT cables etc including necessary fixing arrangement on wall in all respect and comprising of following: (a) Incomer MCCB 4 pole, 160 Amp, ICU=16KA,ICS=100 % ICU with adjustable thermal settings - 01 No (b) Outgoing MCCB 4 pole 63 Amp,ICU=16 KA,ICS=100 % ICU with adjustable thermal settings-01 Nos & MCCB 4 pole 125 Amps ICU=16 KA,ICS=100 % ICU -01 Nos (c ) Multifunctional Meter- 01 No (d) Single Phase Preventor- 01 No (e) Phase sequence controller - 01 No (f) LED Indicator lamps -01 set (R,Y,B) (g) Star delta starter fully automatic suitable for 12.5 HP AHU Motor-01 Nos. (f) Starter for 3 KW capacity strip heater single phase 4 nos qty-06 Nos
M & L for sign board with size of 5 X 3 feet of steel sheet of 5 mm thick heavy duty including writing alphabatic letters computerised with retro refelctive sheets of size 150mm fonts and fixed with stainless steel pipe heavy duty of size 40 to 50 mm dia and to be fixed outside the installations along with required PCC and top of the sign board should be 2.3 mtr complete all as specified and directed.
M&L in repair for earthing complete with galvanized steel earth plate electrodes of size 600 mm x 600 mm x 6 mm thick buried directly in ground, earth plate not less than 2.25 mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to and including galvanized steel earth strip 25 x 4 mm by means of bolts, nuts, check nuts and washers of galvanized iron and using charcoal and salt upto plate edge level inlcuding PCC pit in PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate), RCC frame with 40 mm thick RCC cover of RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) reinforced with 8 mm dia deformed bars handle including excavation and earth work in any type of soil medium grade GI watering pipe 20 mm bore with funnel and wire mesh and light grade GI protection pipe 40 mm bore main board complete all as shown in electrical plate No.3 of SSR Pt-I of 2009 connected to equipment and testing on completion complete all as specified and directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor. (ii) Earth lead wire and its protection pipe upto and including 7.50 M from the top of earth electrode are included under this item and additional length if required at site will be measured and paid separately under respective item.
S&F of GI strip of size 25 mm x 4 mm thick duly fixed with wall / floor / equipment complete all as specified and directed.
VISHAL TRADERS
BRITE INDUSTRIES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .