| 1 | L1₹47.7 LAccepted-AOC RANGAPAHAR CROSSING RAILWAY GATE NO 1 DIMAPUR 797 112 NAGALAND | DIMAPUR | DIMAPUR | NAGALAND | 797112 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹50.6 L+₹2.1 L (4.22%)Rejected-Finance | L2 | Rejected-Finance Higher bid value | |
| 3 | L3₹51.3 L+₹2.8 L (5.68%)Rejected-Finance | L3 | Rejected-Finance Higher bid value | |
| 4 | L4₹51.8 L+₹3.3 L (6.70%)Rejected-Finance | L4 | Rejected-Finance Higher bid value | |
| 5 | L5₹52.1 L+₹3.6 L (7.33%)Rejected-Finance | L5 | Rejected-Finance Higher bid value |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
3 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 868 EWS
GE 868 EWS PIN- 913 868 C/o 99 APO
SPECIAL REPAIRS TO BLDG NO T 21 (OR LINE) OF B COY OF 164 INF BN (TA) NAGA AND ADDN_ALTN TO BLDG NO T 34 AT SANGAM COMPLEX AND PROVN OF TOILET BLOCK AT 3 CORPS ZONE WKS AND 116 ENGR REGT AT RANGAPAHAR MIL STN
2022_MES_501428_1
8419/C/E8
Open Tender
Civil Works
Item Rate
180 days
RANGAPAHAR
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Yes
GE 868 EWS
₹94,000
Yes
28 Feb 2022
13 Jan 2022
5 Feb 2022
13 Jan 2022
3 Feb 2022
27 Jan 2022
60 days
Amount
B/R WORKS Demolition of plain cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Dismantling of plain or corrugated sheeting of any guage/thickness in roof covering/wall clading complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Taking down chowkhat or frames not exc 1.5 Sqm each (without taking off shutter from the frame) complete all as specifed and directed.
Taking down chowkhat or frames exc 1.5 Sqm but not exc 4 Sqm each (without taking off shutter from the frame) complete all as specifed and directed.
Dismantling timber scantlings unframed work 40 sqcm and over in section in any position complete all as specified and directed.
Demolition of reed, lathing single or double, including battens and plaster or chicken wire lathing complete all as specified and directed.
Dismantling Asbestos cement sheet (Corrugated, semi corrugated etc ) in roof covering complete all as specified and directed.
Disamantling wall and ceiling boards (fibre, pulp, insulation, etc.) any thickness including cover fillets complete all as specified and directed.
Dismantling boarding any description fixed in any position with nails complete all as specified and directed.
Dismantling of wrought iron or mild steel work of any description complete all as specified and directed.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for fdn, n.exc 10 sq m on plan and n.exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
M&L for surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in soft/ loose soil complete all as specified and directed.
Excavation over areas, n.exc 1.5m deep,and getting out for foundation, etc. soft/loose soil complete all as specified and directed.
Excavation over areas exceeding 1.5m deep but not exceeding 3m deep and getting out in soft/ loose soil complete all as specified and directed.
Returning, filling in trenches including shearing , leveling, watering in layers n.exc 25cm thick soft loose soil complete all as specified and directed.
Removal of excavated soil n.exc 50mtr distance and depositing where directed n.exc 1.5m above the starting point complete all as specified and directed.
M&L roughening surface of old concrete floor by picking ,sweeping clean and washing down with water to remove dust etc complete all as specified and directed.
M&L for screed bed or bedding layer of mortar 20mm thick in CM 1:6 for laying floor finishes complete all as specified and directed.
M&L for chequered cement concrete tiles of Size 25mm thick any description jointed and pointed in neat cement slurry in floors with grey cement and pigment complete all as specified and directed.
M&L for hardcore of gauge n.exc 63mm, deposited, spread and levelled in layers n.exc 15cm thick, watered and rammmed to a true surface complete all as specified and directed.
M&L cement concrete 75 mm thick type D2 (1:4:8) using (40 mm graded aggregate) as in sub base complete all as specified and directed.
M&L for Chequered cement concrete tiles 25mm thick,set, jointed with grey cement and pigment and pointed in neat cement slurry in floors over 15 mm thick screed bed CM 1:6 complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 (using 40mm graded stone)as in fdn filling mass concrete complete all as specified and directed.
M&L for loose filling with broken bricks aggregate of gauge 80 to 150mm in soakage pits, soakage wells complete all as specified and directed.
M&L for loose filling with broken bricks aggregate of gauge 40 to 80mm in soakage pits, soakage wells complete all as specified and directed.
M&L for PCC 1:4:8 type D-2, 100 mm thick (using 40 mm graded stone aggregate) as in hardstanding complete all as specified and directed.
M&L for PCC 25mm thick type B-1, 1:2:4 (using 20 mm graded stone aggregate) as in sub base of floor complete all as specified and directed.
M&L 25mm thick PCC 1:2:4 B0 (12.5mm graded crushed stone aggregate ) as in Damp proof course to horizontal or vertical surfaces including necessary form work complete all as specified and directed.
M&L for RCC nominal mix type B1 1:2:4 using 20mm graded aggregate as in lintels complete all as specified and directed.
M&L for RCC 1:2:4 (20 mm graded stone aggregate) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and shrlves and the like complete all as specified and directed.
M&L formwork to sides and soffits of floor or roof beams,beam haunchings, girders, bressumers, lintels, cantilever, shelves including supports, overhangs, etc also splys between floors and beams etc complete all as specified and directed.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exc 200mm thick (Horizontal or sloping) for fair finished flat surfaces of concrete complete all as specified and directed.
M&L for 15 mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified and directed.
M&L for coloured non skid ceramic tiles 7 to 8 mm thick (square/rectangular) in section exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
Same as per ser No 35.00 but on vertical surfaces such as skirting , dado risers to steps over and including 10 mm thick bedding layer in CM 1:4 , set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for coloured non skid ceramic tiles 7 to 8 mm thick (square/rectangular) in section exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10mm thick CM (1:4) backing coat complete all as specified and directed.
M&L Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
Same as per 39.00 but on vertical surfaces such as skirting , dado risers to steps over and including 10 mm thick bedding layer in CM 1:4 , set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for non skid coloured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exc 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed 15mm thick in CM 1:6 all as directed .
S&F Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed.
S&F Pre-painted galvatume aluminum zinc coating GI based Plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed.
S&F Steel work in tubular trusses including special shaped washer etc. for steel work in roof trusses, purlins,rails and fastening heavey bracket framing including distance pieces, cleats etccomplete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed.
S&F for joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated confirming Fe 410-W (Gde-E- 250) quality- A complete all as specified and directed.
M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe 410 -W (Gde-E- 250) quality-A complete all as specified and directed.
S&F for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe 410 -W (Gde-E- 250) quality-B complete all as specified and directed.
S&F steel work in tubular trusses, post, purlins including special shaped washer etc. Complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade st-240 complete all as specified and directed.
S&F for bands, straps, supports or stays for rainwater, ventilating pipes, incl bolts, if reqd : hooks (say), heavy, for large gates, hook and pintle hinges : large hasps and staples; chains; hand made sliding bolts ; clamps; hold fasts; waal ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts,; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde E-165 complete all as specified and directed.
S&F 2nd class hard wood scantling as in purlins rafters ,& framed work etc clean sawn complete all as specified and directed.
All as per item 50.00 as above but except timber complete all as specified and directed.
S&F for 4 mm thick of size 600x600mm HSPC (high pressure Steam Cured) non asbestos fibre cement reinforced multipurpose board, pre-primetered self embossed, textured designer board E-Board Classic fixed or laid/inserted to timber/ GI frame work with screws to be fixed in ceiling flat or sloping and Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre both ways, size of grid 605 x 605mm fixed with steel dash fasteners or from purlin from the roof with alignment clip including providing provisions for light fixtures of any size complete all as specified.
M&L 25mm thick second class hard wood boarding , plained one side with butt joints as in eaves boards complete all as specified and directed.
M&L for 75 mm thick PCC 1:3:6 type C2 , using 40 mm graded agg in plinth protection/aprons/path laid to slope of 1:12, finished fair and even without using extra cement with and including all necessary formwork to divide tha area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 10 mm wide joints throughout thickness of plinth protection complete all as specified and directed
M&L GI wire netting 0.71 mm dia and 12 mm mesh lathing in to reed in walls incl all laps cutting and waste complete all as specified and directed.
M&L 15mm thick plastering in CM 1:4 on one side of lathing in two separate layers even and smooth without using extra cement complete all as specified and directed.
M&L 10 mm thick plastering in CM 1:6 the other side of lathing finished even and smooth without using extra cement complete all as specified and directed.
M&L for 2nd class hard wood plain solid straight chowkats and frames wrought framed rebated on the solid rounded or chamfered put together with glue pined joints complete all as specified and directed.
S&F for Pressed steel frames of 165x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete all as specified and directed.
M&L for 35 mm thick 2nd class hardwood plain framed pannelled shutter (any number of panels) with panels of timber flat on both sides or of veneered particle board medium density , wood particle board with commercial face veneers , supplied and fitted to chowkats complete all as specified and directed.
M&L 35mm thick 2nd class hard wood Glazed and skelton shutter, open rebated and prepared to receive glass, gauge etc. devided into squares with plain chamfered or rounded, mitred and rebated sash bars edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Part-I Section-8 clause 8.24(a) complete all as specified and directed.
M&L 30mm thick 2nd class hard wood Glazed and skelton window and ventilator shutter, open rebated and prepared to receive glass, gauge etc. divided into squares with plain chamfered or rounded, mitred and rebated sash bars edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Part-I Section-8 clause 8.24(b) complete all as specified and directed.
M&L 30mm thick 2nd class hard wood Glazed and skelton window and ventilator shutter, open rebated and prepared to receive glass, gauge etc. devided into squares with plain chamfered or rounded, mitred and rebated without sash bars edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Part-I Section-8 clause 8.24(b) complete all as specified and directed.
S&F,Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed.
S&F Factory made solid panel pvc door shutter 30 mm thick (style) con-sisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be cov-ered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement suppling & fixing at site as per specification and drawing complete all as specified and directed.
S&F 150 mm long aluminium anodised tower bolts complete all as specified and directed.
S&F 100mm long aluminium anodised handles cast copper complete all as specified and directed.
S&F for steel ventilator with top hung shutter including hinges steel peg stay, complete all as specified and directed.
M&L sheet glass, obscured or frosted 3mm thick and glazing with oil putty in squares. nexc 0.5 Sqm each complete all as specified and directed.
M&L butt hinges medium grade cold rolled mild steel and fixed size of hinges 100 mm long size complete all as specified and directed.
M&L butt hinges, medium weight 75 mm long size complete all as specified and directed.
S&F Aluminium anodised barrel tower bolt of extruded section and fixed 100 mm long complete all as specified and directed.
S&F Aluminium anodised barrel tower bolt of extruded section and fixed 200 mm long complete all as specified and directed.
S&F 150mm long aluminum hook and eye, complete all as specifed and directed.
S&F Aluminium handle cast type anodised 150 mm long complete all as specified and directed.
S&F 125mm size aluminium handles,cast type,anodised all as directed complete all as specified and directed.
S&F Aluminium alloy anodised sliding door bolt with hasp and staple (bolt type fixing clips of sheet cast or extruxded section(300 mm long) complete all as specified and directed.
S&F 300mm, mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
S&F floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, overall length of cover plate 140mm complete all as specified and directed.
S&F 3 mm thick Figured glass, pin head type and glazing with oil putty in squares n.exc 0.5 sq. m in each pane complete all as specified and directed.
M&L sheet glass ordinary quality 3mm thick and glazing with oil putty in squares n.exc. 0.5 sqm each pane complete all as specified and directed.
S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane including hacking out old broken glass from any type of frame complete all as specified and directed.
S&F galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed.
Taking down cement plaster on brick walls including raking out joints hacking for key, scrubbing down with water etc complete all as specified and directed.
Demolition of brick work built in cement mortar incl all quions, arches pillars etc but excl ashalar facing complete all as specified and directed.
M&L brick work with sub class B bricks straight or curved on plan exc 6 m mean radius in CM 1:6 complete all as specified and directed.
M&L brick work with sub class B bricks straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed.
M&L for brickwork in cement mortar 1:6 with sub class 'B' bricks in one brick thick honey comb walling etc complete all as specified and directed.
M&L rendering 15mm thick in cement mortar 1:4 on fair faces of brick or concrete work even and smooth without using extra cement complete all as specified and directed.
M&L rendering 10mm thick in cement mortar 1:6 on fair faces of brick or concrete work even and smooth without using extra cement complete all as specified and directed.
M&L rendering 15mm thick in cement mortar 1:3 mixed with water proofing compound @ 3% by wt of cement finished fair faces of brick/concrete surfaces even and fair without using extra cement complete all as specified and directed. Note:-WPC will be measured and paid separately.
Supply only integral water proofing compound ( ISI marked ) complete all as specified and directed.
M&L for applying two coats of oil bound distemper on new plastered surfaces of walls including preparation of surface complete all as specified and directed.
M&L for preparation of old decorated surfaces of walls by washing, rubbing down and stopping of distempered surfaces and applying one coat of oil bound distemper of approved shade/tint complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying two coats of cement base paint of approved shade on walls complete all as specified and directed.
M&L for complete removal of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces and applying two coats of cement base paint of approved shade on walls complete all as specified and directed.
M&L for preparation of new untreated wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparation of old painted surfaces of wood and wood based material of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of new steel surfaces exc 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
M&L for preparation of new wall surfaces plastered or unplastered and applying three coat white wash on undecorated surfaces complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning for refixing with all fittings for 15 mm bore GI tubing complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning for refixing with all fittings for 20 mm bore GI tubing complete all as specified and directed.
Refixing of old steel tubing and connections in new or old position with all fittings to floor, wall or ceiling as directed, for 15mm bore GI tubing complete all as specified and directed.
Refixing of old steel tubing and connections in new or old position with all fittings to floor, wall or ceiling as directed, for 20mm bore GI tubing complete all as specified and directed.
S&F tubes medium grade, galvanised wih all fittings and fixed complete to walls and ceiling or laid on floors etc, 15 mm bore complete all as specified and directed.
S&F tubes medium grade, galvanised wih all fittings and fixed complete to walls and ceiling or laid on floors etc, 20 mm bore complete all as specified and directed.
S&F in repairs vitreous china wash hand basin including brackets, white size 550 x 400 mm incl cutting cutting for and pinning in ends of brackets. Including Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other and fixed complete all as specified and directed.
S&F vitreous china wash basin, size 550 x 400mm white including brackets, and waste coupling & pipe of 32mm dia, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other and fixed complete all as specified and directed.
S&F in repairs vitreous china bowl urinal flat back size of 465x355x265 mm white (minimum) with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and directed.
S&F for vitrious china urinal, half stall type, white including flushing cistern, flush pipe and waste pipe. CP waste coupling complete complete all as specified and directed.
S&F in repairs vitreous china squatting pan 'orissa' pattern size 580x440mm white with integral foot rest (excluding flushing cistern and flush pipe) complete all as specified and directed.
S&F vitreous china squatting pan 'orissa' pattern size 580x440mm white with integral foot rest (excluding flushing cistern and flush pipe) complete all as specified and directed.
S&F in repair PVC flushing cistern syphonic action type, 10 liters capacity, low level white with inlet ball valve, float and handle including bracket including PVC flush pipe, 32mm dia as fixed in repairs complete all as specified and directed. (Make : Hindware (Sleek)/Commander (Slim)/Parryware)
S&F 10 ltrs capacity PVC valveless syphonic action type flushing cistern low level with inlet ball valve float and dual flush type complete all as specified and directed.
S&F 15mm bore bib tape cast copper alloy with crutch or butter fly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F 15mm bore angle stop cock, cast copper alloy, screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe complete all as specified and directed.
S&F in repairs for 15mm dia of pipe bib taps cast copper alloy, fancy type, chromium plated with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repairs Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot' or ‘Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
S&F in repairs for 15mm dia of pipe stop valves,fancy type and chromium plated screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for Unions and fixed complete all as specified and directed.
S&F in repairs PVC connection 15mm dia and 45cm long with two Nos of brass checknuts and washers complete all as specified and directed.
S&F in repairs brass chromium plated shower rose 125 mm in size with or without swivel joints any size incl fixing to steel pipe or union,complete all as specified and directed.
S&F of soap-dish chromium plated complete all as specified and directed.
S&F toilet paper holder, coloured vitreous china, box type fixed to walls complete all as specified and directed.
S&F Glass shelves, with 12mm thick desher glass incl CP brackets with brass nuts 300 mm long complete all as specified and directed.
S&F grating doom 125mm dia with waste hole of PTMT (Min wt 40 gms) complete all as specified and directed.
S&F in repairs 600mm long tubular towel rail brass chromium plated 20mm dia, D type 60cm long fixed with two plugs (Gutties) of 2nd class hard wood embeded in cement mortor 1:3 with MS screws complete all as specified and directed.
S&F towel ring of PTMT fixed with and including Chromium plated Brass Screws and wooden/ plastic cleats ( Minimum weight 90 gms) etc fixed in kitchen complete all as specified and directed.
S&F in repairs PVC mounted 5mm thick bevelled edge looking mirror 600 x 450mm including taking down old fixed with chromium plated brass screws and cup washers complete all as specified and directed.
S&F PVC Shelves of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats. (Minimum weight 105 gms) complete all as specified and directed.
S&F CP towel rail 600mm long with brackets, aluminium anodised 20mm dia complete all as specified and directed.
S&F CP grating 100mm dia PTMT with waste hole (Min wt 25 Gms) complete all as specified and directed.
S&F brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed 15mm dia pipe complete all as specified and directed.
S&F 15mm bore Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
S&F PVC (SWR) floor trap plain 50mm dia with grating including jointing with solvent cement complete all as specified and directed.
S&F CP shower roses with or without swivel joints,any size, including fixing to steel pipe or union complete all as specified and directed.
M&L cement concrete type C2 1:3:6 (40 mm graded agg) as in surface channels and drains complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement incl firms moulds complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in cills, copings, benching on chajjas, roof kerbs, bed blocks and the like including weathering, slightly rounded or chamfered angles and throating as directed with and including necessary form work complete all as specified and directed.
Demolition of cement concrete in reinforced of any description and in any position not otherwise specifically provided, complete all as specified & directed.
M&L TMT bars, 6 to 8mm, cut to length, bent to shape required including cranking,bending spirally for hooping for column, hooking ends and binding with and incl MS wire(annealed) not less than 0.9 mm dia complete all as specified and directed.
M&L for deformed steel bars 10 mm dia and over, cut tro length, bent to shape required, including cranking, bending spirally or hooping for coloum hooking end stand binding with miuld steel wire less than 0.9 mm dia complete all as specified and dierected.
All as per item 141.00 but 5 mm dia and over upto and including 10 mm dia Tor bars as in stirrups, spacers and binders, conferming to geraded IS -432 (Part-I)
M&L for precast cement concrete type B1 1:2:4 (Using 20 mm graded stone aggregate) as in cover slabs, manhole cover, chamber cover and drainge cover set in cement mortar 1:6 including necessary formwok complete all as specified and directed.
M&L for PCC (1:3:6) type C-1 using 20mm graded stone aggregate as in cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed including necessary formwork complete all as specified and directed.
M&L for PCC (1:2:4) type B1 using 20mm aggregate in plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
S&F PVC (SWR) 110mm dia junction single T equal or un equalwith an floor complete all as specified and directed.
S&F of PVC (SWR) 75 mm dia pipe as per specification complete all as specified and directed.
S&F in repair 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to floor complete all as specified and directed.
S&F in repair 75 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to floor complete all as specified and directed.
S&F in repair 75mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed.
S&F of 110mm dia PVC (SWR) bends complete all as specified and directed.
S&F 75mm PVC(SWR) bends any radius with acess door complete all as specified and directed.
S&F of 75mm dia PVC (SWR) Vent cowl complete all as specified and directed.
S&F 75mm dia, PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed.
S&F in repairs for 75mm bore dia pipe Stack clamps out of 50mm by 5mm flat iron & 16mm dia round iron stays, including bolts & nuts & securing ends of stay to wall or roof complete all as specified and directed.
S&F 75mm bore PVC (SWR) bends any radius complete all as specified and directed.
M&L for DWCPE (SN8) 150 mm (ID) diameter Pipes laid in trenches complete all as specified and directed.
M&L for Concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:3:6 type C2 complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 (40mm grade stone aggregate) as in bed to 110 mm dia SGSW /PVC pipes including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
M&L for cutting chease for concealed water tubing and making good cutting n.exc 10 cm girth in CM 1:3 complete all as specified and directed.
M&L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for internal dia of pipe 150mm complete all as specified and directed.
M&L dismantling water tank of exc 500 ltr and not exc 1000 ltr Capacity complete all as specified and directed.
S&F rotational moulded polyethylene 1000 Ltrs Capacity water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position in SSR Part-I including ball brass valve, with polythelene float and fly nut complete screwed down for iron pipe of 20 mm dia complete all as specified and directed.
S&F 20mm gun metal, globe or gate valves with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repairs for Draperly rod /Harrison rails of CP of 20mm dia with fixing brackets , stops, rollers and rings etc complete all as specified and directed.
E/M WORKS Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete, including fitting & fixtures such as switches with board, ceiling roses, pendents, bell/ buzzer, bell push, lamp holders, regulators, sockets, light fittings etc., removing material from site and making good to the disturbed surfaces of walls, ceiling, floors etc. including making good the disturbed surfaces and paint touch up to match with the existing surface complete all as specified and directed.
M&L for Point wiring complete with two runs of 1.5 sqmm single core PVC insulated FR-LSH cable 1100 volts grade with multi-stranded copper conductors, drawn through and including PVC double locked Casing & caping including provision of 1.5 sqmm, FR-LSH, PVC insulated copper cable as earth continuity conductor connected to common earth dolly, including PVC rectagular box for mounting switches / sockets / regulators etc. with 3 mm thick plastic laminated sheet cover of suitable size as required at site complete all as specified and directed. Make:- Richa/Finolex/RR Kabel or any eqivalent make as approved by GE. Make of caping/casing & PVC boxes :- Prestoplast/Finolex/supreme/Richa or any eqivalent make as approved by GE.
One light/Ceiling/Exhaust fan controlled by one, one way switch complete all as specified and directed.
One 3 pin socket outlet 5 Amps on the same board with other switches complete all as specified and directed.
One 3 pin socket outlet 5 Amps on the switch socket combination complete all as specified and directed.
All as per item No- 167.00 here-in-before but with 2.5 Sq mm for 3 pin 15 Amps socket point controlled by one switch on independent board and 2.5 Sq mm copper conductor green in colour as earth continuity conductor connected to common earth dolly complete all as specified and directed.
M&L for Switch piano flush type single pole, one way 5A complete all as specified and directed. Make:- Anchor/Legrand/SSK/Palza or any eqivalent make as approved by GE.
M&L for Socket outlet, 2 in 1, 5 pin 5A flush type complete all as specified and directed. Make:- Anchor/Legrand/SSK/Palza or any eqivalent make as approved by GE.
M&L for Switch Socket combination, 2 in 1, 5 pin 6A/16A flush type complete all as specified and directed. Make:- Anchor/Legrand/SSK/Palza or any eqivalent make as approved by GE.
M&L for stepped type electronic fan regulator 100 Watt socket size flush type on the existing phenolic laminated sheet etc complete all as specified and directed. Make:- Anchor/Legrand/SSK/Palza or any eqivalent make as approved by GE.
M&L for ceiling rose 3 terminal PVC/Polycarbonate isolated body with PVC round/squareblock complete all as specified and directed. Make:- Anchor/Legrand/SSK/Palza or any eqivalent make as approved by GE.
M&L for sub main wiring with two runs of 4.0 Sq mm and one run of 4.0 Sq mm for earth wire with multi standard copper conductors of , 1100 volts grade, drawn through and including PVC double locked Casing & caping including complete all as specified and directed. Make:- Richa/Finolex/RR Kabel or any eqivalent make as approved by GE. Make of caping/casing :- Prestoplast/Finolex/supreme or any eqivalent make as approved by GE.
M&L for Lamp holder , PVC/ Polycarbonate type with PVC round/square block incl 9 watt LED lamp suitable for lamp holder fittings incl taking down old unsv light fitting complete all as specified and directed. Make:- Anchor/Havells/Legrand or any eqivalent make as approved by GE. MakeOf Lamp :- Havells/Bajaj/Philips or any eqivalent make as approved by GE.
Taking down existing unsv tube light fitting of any size and S&F for, IP>= 20, Class I, LED light fitting 1 x 20 W (4 FT), 240V, PF-0.9, CRI ≥= 80, CT>= 6000 K, wall /surface mounted, integrated type with all accessories internally prewired and including connecting up with and including twin/three core twisted flexible copper conductor cable of suitable size in & incl flexible hose from ceiling rose to fitting complete all as specified and directed. Make : Crompton Greaves Cat Part No : CCS-102-20-SL-DP-NWH/Bajaj/Philips or any eqivalent make as approved by GE.
All as per item No 176.00 above but 10 watt LED, 2' batten complete all as specified and directed. Make : CG/Bajaj/Philips
Supply , fixing and testing in replacement of LED Bldg Security light fitting of capacity 20 watts, CRI > 70, Power factor > 1.95, colour temp 5700 K, Luminous effieciency not less than 100 lumen/watt, 6000 Lumens output, IP-66 protection including electronic driver (SMPS based constant current supply with < 10% THD, output open/short circuit protection, phase to phase protection, over voltage protection, surge voltage protection etc) unit suitable for working volt 140-270 V AC, 50 Hz, pressure die cast aluminium housing and finishing epoxy white powder coated grey colur after phospho chromate treatment with all accessories and connecting up ccomplete all as specified and directed. (Note : Test certificate in support of the technical parameters of the light fittings is to be submitted in original to the Engr-in-Charge by the contractor.) Make : CG, Cat No- LSTS-20-CDL-M/ Bajaj/ Philips or any eqivalent make as approved by GE.
M&L for MCB Distribution board double door type TPN 8 way, sheet steel, powder painted, with copper bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacity including taking down old unsv MCB DBs complete all as specified and directed. Make : Legrand/ABB/Siemens or any eqivalent make as approved by GE.
M&L for MCB TPN 43 to 100 Amps, 415 volts, 50 Hz suitable for fixing in MCB DB 'C' series incl taking down old unsv MCB complete all as specified and directed. Make : Legrand Cat No 408704/ ABB/Siemens or any eqivalent make as approved by GE.
M&L for MCB Distribution board double door type SPN 8 way, sheet steel, powder painted, with neutral link & earth bar etc. and fixing MCBs of various rating capacity including taking down old unsv MCB DBs complete all as specified and directed. Make:- Legrand Cat No 507611 /ABB/Siemens or any eqivalent make as approved by GE.
All as per item No- 181.00 here-in-before but MCB DB 4 Way complete all as specified and directed.
S&F MCB SPN 40 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning incl taking down old unsv MCB complete all as specified and directed. Make:- Legrand Cat No 408636 /ABB/Siemens or any eqivalent make as approved by GE.
S&F MCB SP 6-32 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning incl taking down old unsv MCB complete all as specified and directed. Make:- Legrand Cat No 408587-95 /ABB/Siemens or any eqivalent make as approved by GE.
S&F exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm complete all as specified and directed. (Make Havells, Model Ventil Air DB or equivalent of Crompton Greaves/Bajaj)
S&F Electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all acessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed ake : Bajaj/CG/USha/Rico or Equivalent
S&F LED luminaire 600 mm x 600 mm, 40 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size with all accessories internally pre wired complete all as specified and directed. Make: CG/Bajaj/Phipips or any eqivalent make as approved by GE.
S&F for Globe light 8' including base holder bracket complete with 9 Watt LED Bulb and all accessories complete all as specified and directed Make :Havells/Bajaj/CG/Philips or any eqivalent make as approved by GE.
Supply and laying or fixing/ making connectin by passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4.00 sq. mm 2 Core nominal cross section all as specified and directed.
M&L for MCB Distribution board double door type SPN 2 way, sheet steel, powder painted, with bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacity complete all as specified and directed. Make:- Legrand/ ABB/Siemens or any eqivalent make as approved by GE.
S&F 20 mm dia Rigid non-metallic PVC conduit exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed.
Taking down of ceiling fan, dismantling blades and removing fan and blades to store for reuse at site and refixing of the fan after completion of ceiling works complete all as specified and directed.
Taking down Ceiling fan of any sweep carefully from its installed position, dismantling complete, cleaning all dust, applying grease for bearing, painting of fans complete with superior quality synthetic enamel paint by spraying including filling cavaties with filler, after cleaning all dust, reassembling the fan and blades, hanging/ fixing the fan in its original position and testing on completion complete all as specified and directed.
M&L for rubber bush with clamping set, comprising GI bolt, nut and split pin complete all as specified and directed.
M&L for replacement of capacitor2.5 Mfd incl making electrical connection complete all as specified and directed.
M&L for replacement of steel ball bearing/bush of suitable size compatible to the existing ceiling fan complete all as specified and directed.
M&L for copper rewinding for suitable size complete to the existing ceiling fan complete all as specifed and directed.
Taking down LT UG cable/ service connection of any size and M&L for laying of LT UG cable, XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 25 sq mm, 3.5 core complete all as specified and directed. NOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items. Make : Richa/Polycab/Havells or any eqivalent make as approved by GE.
M&L for laying of LT UG cable, XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 10 sq mm, 2 core complete all as specified and directed. NOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items. Make : Richa/Polycab/ Finolex.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out in soft/ loose soil complete all as specified and directed.
Returning filling in trenches including spreading leveling watering and well ramming in layers not exceeding 25 cm thick all complete all as specified and directed.
Removing of excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all complete all as specified ans directed.
M&L for spread fine river sand in trenches complete all as specified ans as directed. NOTE: For measurement purpose, punned down thickness shall only be taken complete all as specified and directed.
M&L for laying brick sub class 'B' old size burnt bricks for cable protection of size 230mmx115mmx75mm complete all as specified and directed
Supply & laying tubes ' Medium grade' galvanised, with all fittings, fixed complete to walls, poles, ceilings or laid in floors/ trenches/ road crossing for protection of cables of size 40 mm dia bore including taking out unsv GI tubing complete all as specified and directed. Make:- Jindal/TATA/Prakash surya or any eqivalent make as approved by GE.
M&L for earthing complete with galvanized steel earth plate electrode of size 600x600x6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected to galvanised earth lead wire 4 mm dia as earth lead connectd by means of bolts, nuts, washers and check nuts all as shown in electrical plate No 3 of MES SSR Part-I, including testing on completion complete all as specified and directed.
SHRI RAJNATH SINGH
PERFECT BUILDERS AND SUPPLIERS
SHRI HRIDAY NARAIN GIRI
das enterprises
KAILASH KUMAR LADHA
m/s chakraborty enterprises
M/S RAHUL TRADING CO.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .