Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical NEAR BHIWADI CHOPANKI SP4 870 A INDUSTRIAL AREA PATHREDI 301019 ALWAR RAJASTHAN 301019 | ALWAR | RAJASTHAN | 301019 | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical 4801 BHARAT RAM ROAD 24 DARYAGANJ DELHI CENTRAL DELHI DELHI 110002 | CENTRAL DELHI | DELHI | 110002 | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical 4 CENTRAL DELHI DELHI 110008 | WEST DELHI | DELHI | 110008 | Admitted-Fee/PreQual/Technical |
| 4 | Admitted-Fee/PreQual/Technical F 61 62 63 RAOD NO 5A BINDAYKA INDUSTRIAL AREA JAIPUR RAJASTHAN 302012 | JAIPUR | RAJASTHAN | 302012 | Admitted-Fee/PreQual/Technical |
| 5 | Admitted-Fee/PreQual/Technical D 90 OKHLA INDUSTRIAL AREA PHASE 1 NEW DELHI NEW DELHI DELHI 110020 | SOUTH EAST DELHI | DELHI | 110020 | Admitted-Fee/PreQual/Technical |
Tender Value
Refer Docs
Closing Date
22 Dec 2025, 2:30 pmClosed
Krishan Pal Singh
Technip Energies India Ltd A4, Sector-1 Neida Uttar Pradesh 201301
Design, Engineering, manufacturing, procurement of materials and bought out components, assembly at shop, Inspection including inspection by TPIA, Testing at manufacturers works, packing,
2025_REFHQ_187852_1
TP/214227C/DR/1621-0003/1092
Limited
Electrical - Cables, Switchgear and Other Control Equipment
Supply
180 days
IOCL DIGBOI REFINERY
Refer Tender Details
6 documents required · 6 mandatory
Exempted
27 Aug 2026
5 Dec 2025
23 Dec 2025
5 Dec 2025
22 Dec 2025
13 Dec 2025
5 Dec 2025 - 12 Dec 2025
3Cx2.5 sq. mm., Cu, XLPE insulated, 0.65/1.1kV Grade. Design, manufacture, supply, testing at works, inspection, packing, and delivery at site of 3Cx 2.5 sq. mm, 0.65/1.1kV, XLPE insulated, copper conductor, extruded PVC inner sheathed, galvanized steel strips/wire armoured and FRLS extruded PVC (type ST2) outer sheathed. MV cable shall be in line with attached specifications, relevant codes & standards attached with MR.
3Cx4 sq. mm., Cu, XLPE insulated, 0.65/1.1kV Grade. Design, manufacture, supply, testing at works, inspection, packing, and delivery at site of 3Cx 4 sq. mm, 0.65/1.1kV, XLPE insulated, copper conductor, extruded PVC inner sheathed, galvanized steel strips/wire armoured and FRLS extruded PVC (type ST2) outer sheathed. MV cable shall be in line with attached specifications, relevant codes & standards attached with MR.
3Cx6 sq. mm., Cu, XLPE insulated, 0.65/1.1kV Grade. Design, manufacture, supply, testing at works, inspection, packing, and delivery at site of 3Cx2.5 sq. mm, 0.65/1.1kV, XLPE insulated, aluminum conductor, extruded PVC inner sheathed, galvanized steel strips/wire armoured and FRLS extruded PVC (type ST2) outer sheathed. MV cable shall be in line with attached specifications, relevant codes & standards attached with MR.
3Cx25 sq. mm., Al, XLPE insulated, 0.65/1.1kV Grade. Design, manufacture, supply, testing at works, inspection, packing, and delivery at site of 3Cx25 sq. mm, 0.65/1.1kV, XLPE insulated, aluminum conductor, extruded PVC inner sheathed, galvanized steel strips/wire armoured and FRLS extruded PVC (type ST2) outer sheathed. MV cable shall be in line with attached specifications, relevant codes & standards attached with MR.
3Cx35 sq. mm., Al, XLPE insulated, 0.65/1.1kV Grade. Design, manufacture, supply, testing at works, inspection, packing, and delivery at site of 3Cx35 sq. mm, 0.65/1.1kV, XLPE insulated, aluminum conductor, extruded PVC inner sheathed, galvanized steel strips/wire armoured and FRLS extruded PVC (type ST2) outer sheathed. MV cable shall be in line with attached specifications, relevant codes & standards attached with MR.
3Cx50 sq. mm., Al, XLPE insulated, 0.65/1.1kV Grade. Design, manufacture, supply, testing at works, inspection, packing, and delivery at site of 3Cx50 sq. mm, 0.65/1.1kV, XLPE insulated, aluminum conductor, extruded PVC inner sheathed, galvanized steel strips/wire armoured and FRLS extruded PVC (type ST2) outer sheathed. MV cable shall be in line with attached specifications, relevant codes & standards attached with MR.
3Cx70 sq. mm., Al, XLPE insulated, 0.65/1.1kV Grade. Design, manufacture, supply, testing at works, inspection, packing, and delivery at site of 3Cx70 sq. mm, 0.65/1.1kV, XLPE insulated, aluminum conductor, extruded PVC inner sheathed, galvanized steel strips/wire armoured and FRLS extruded PVC (type ST2) outer sheathed. MV cable shall be in line with attached specifications, relevant codes & standards attached with MR.
3Cx95 sq. mm., Al, XLPE insulated, 0.65/1.1kV Grade. Design, manufacture, supply, testing at works, inspection, packing, and delivery at site of 3Cx95 sq. mm, 0.65/1.1kV, XLPE insulated, aluminum conductor, extruded PVC inner sheathed, galvanized steel strips/wire armoured and FRLS extruded PVC (type ST2) outer sheathed. MV cable shall be in line with attached specifications, relevant codes & standards attached with MR.
3Cx120 sq. mm., Al, XLPE insulated, 0.65/1.1kV Grade. Design, manufacture, supply, testing at works, inspection, packing, and delivery at site of 3Cx120 sq. mm, 0.65/1.1kV, XLPE insulated, aluminum conductor, extruded PVC inner sheathed, galvanized steel strips/wire armoured and FRLS extruded PVC (type ST2) outer sheathed. MV cable shall be in line with attached specifications, relevant codes & standards attached with MR.
3Cx150 sq. mm., Al, XLPE insulated, 0.65/1.1kV Grade. Design, manufacture, supply, testing at works, inspection, packing, and delivery at site of 3Cx150 sq. mm, 0.65/1.1kV, XLPE insulated, aluminum conductor, extruded PVC inner sheathed, galvanized steel strips/wire armoured and FRLS extruded PVC (type ST2) outer sheathed. MV cable shall be in line with attached specifications, relevant codes & standards attached with MR
3Cx185 sq. mm., Al, XLPE insulated, 0.65/1.1kV Grade. Design, manufacture, supply, testing at works, inspection, packing, and delivery at site of 3Cx185 sq. mm, 0.65/1.1kV, XLPE insulated, aluminum conductor, extruded PVC inner sheathed, galvanized steel strips/wire armoured and FRLS extruded PVC (type ST2) outer sheathed. MV cable shall be in line with attached specifications, relevant codes & standards attached with MR.
3.5Cx50 sq. mm., Al, XLPE insulated, 0.65/1.1kV Grade. Design, manufacture, supply, testing at works, inspection, packing, and delivery at site of 3.5Cx35 sq. mm, 0.65/1.1kV, XLPE insulated, aluminum conductor, extruded PVC inner sheathed, galvanized steel strips/wire armoured and FRLS extruded PVC (type ST2) outer sheathed. MV cable shall be in line with attached specifications, relevant codes & standards attached with MR.
3.5Cx95 sq. mm., Al, XLPE insulated, 0.65/1.1kV Grade. Design, manufacture, supply, testing at works, inspection, packing, and delivery at site of 3.5Cx70 sq. mm, 0.65/1.1kV, XLPE insulated, aluminum conductor, extruded PVC inner sheathed, galvanized steel strips/wire armoured and FRLS extruded PVC (type ST2) outer sheathed. MV cable shall be in line with attached specifications, relevant codes & standards attached with MR.
3.5Cx120 sq. mm., Al, XLPE insulated, 0.65/1.1kV Grade. Design, manufacture, supply, testing at works, inspection, packing, and delivery at site of 3.5Cx120 sq. mm, 0.65/1.1kV , XLPE insulated, aluminum conductor, extruded PVC inner sheathed, galvanized steel strips/wire armoured and FR
3.5Cx120 sq. mm., Al, XLPE insulated, overall shielded 0.65/1.1kV Grade. Design, manufacture, supply, testing at works, inspection, packing, and delivery at site of 3.5Cx120 sq. mm, 0.65/1.1kV, XLPE insulated, aluminum conductor, extruded PVC inner sheathed, galvanized steel strips/wire armoured and FRLS extruded PVC (type ST2) outer sheathed and overall shielded. MV cable shall be in line with attached specifications, relevant codes & standards attached with MR
3.5Cx150 sq. mm., Al, XLPE insulated, overall shielded 0.65/1.1kV Grade. Design, manufacture, supply, testing at works, inspection, packing, and delivery at site of 3.5Cx150 sq. mm, 0.65/1.1kV, XLPE insulated, aluminum conductor, extruded PVC inner sheathed, galvanized steel strips/wire armoured and FRLS extruded PVC (type ST2) outer sheathed and overall shielded. MV cable shall be in line with attached specifications, relevant codes & standards attached with MR
3.5Cx185 sq. mm., Al, XLPE insulated, 0.65/1.1kV Grade. Design, manufacture, supply, testing at works, inspection, packing, and delivery at site of 3.5Cx185 sq. mm, 0.65/1.1kV, XLPE insulated, aluminum conductor, extruded PVC inner sheathed, galvanized steel strips/wire armoured and FRLS extruded PVC (type ST2) outer sheathed. MV cable shall be in line with attached specifications, relevant codes & standards attached with MR.
3.5Cx240 sq. mm., Al, XLPE insulated, 0.65/1.1kV Grade. Design, manufacture, supply, testing at works, inspection, packing, and delivery at site of 3.5Cx240 sq. mm, 0.65/1.1kV, XLPE insulated, aluminum conductor, extruded PVC inner sheathed, galvanized steel strips/wire armoured and FRLS extruded PVC (type ST2) outer sheathed. MV cable shall be in line with attached specifications, relevant codes & standards attached with MR
3.5Cx300 sq. mm., Al, XLPE insulated, 0.65/1.1kV Grade. Design, manufacture, supply, testing at works, inspection, packing, and delivery at site of 3.5Cx300 sq. mm, 0.65/1.1kV, XLPE insulated, aluminum conductor, extruded PVC inner sheathed, galvanized steel strips/wire armoured and FRLS extruded PVC (type ST2) outer sheathed. MV cable shall be in line with attached specifications, relevant codes & standards attached with MR
4Cx16 sq. mm., Al, XLPE insulated, 0.65/1.1kV Grade. Design, manufacture, supply, testing at works, inspection, packing, and delivery at site of 4Cx16 sq. mm, 0.65/1.1kV, XLPE insulated, aluminum conductor, extruded PVC inner sheathed, galvanized steel strips/wire armoured and FRLS extruded PVC (type ST2) outer sheathed. MV cable shall be in line with attached specifications, relevant codes & standards attached with MR.
stage.html
html • 0.04 MB
cancelled_1.pdf
pdf • 0.19 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.26 MB
Tender-Acceptance-Format.pdf
Additional Documents • 0.08 MB
FAQs-IOCL-Online-EMD.pdf
Additional Documents • 0.55 MB
Bidders_help_Document_for_Preferencial_Bidding_20230207_v1.pdf
Additional Documents • 0.82 MB
Special_Instructions_to_the_Bidders_Version_5_dated_30_June_2025.pdf
Additional Documents • 2.80 MB
BOQ_198127.xls
BOQ • 0.32 MB
Unpriced_Bid_Documents_1092.xls
Tender Documents • 5.27 MB
Technical_MR.pdf
Tender Documents • 4.84 MB
GPC_Updated.PDF
Additional Documents • 2.01 MB
Commercial_Document.pdf
Additional Documents • 10.49 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .