Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.1 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹23.6 L−₹2.5 L (9.56%)Rejected-Finance SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | L2 | Rejected-Finance Rejected in AOC | |
| 3 | L3₹23.7 L−₹2.3 L (8.91%)Rejected-Finance NURSERY SCHOOL 1 SECTOR 33 SUNCITY KURUKSHETRA ROAD KAITHAL 136027 HARYANA | KAITHAL | KAITHAL | HARYANA | 136027 | L3 | Rejected-Finance Rejected in AOC | |
| 4 | L4₹24.0 L−₹2.1 L (8.07%)Rejected-Finance | L4 | Rejected-Finance Rejected in AOC | |
| 5 | L5₹24.3 L−₹1.8 L (6.91%)Rejected-Finance | L5 | Rejected-Finance Rejected in AOC |
Tender Value
₹27.5 L
EMD Value
₹55,000
Closing Date
8 Jun 2020, 6:00 pmClosed
GE ARMY SURATGARH
GE ARMY SURATGARH
OUTSOURCING FOR 33/11KV MRS MAP PH I, 11 KV SUBSTATION AT MH, MAP PH II, KLP AREA, CETC, SASF BIRDHWAL AND REPAIR REPLACEMENT OF LT PANEL AT 184 MH AT SURATGARH MIL STN
2020_MES_347642_1
GE (A) SOG - 63/19-20
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
SURATGARH
PLEASE REF TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE ARMY SURATGARH
₹55,000
Yes
15 Jun 2020
27 May 2020
10 Jun 2020
27 May 2020
8 Jun 2020
3 Jun 2020
Amount
Maintenance and outsourcing including minor repair / maintenance of Electric installation at Military Hospital, all OTM accommodation and underground LT cable distribution at location by employing Electrician – 01 No. in each shift for three shifts (each shift of 08 hours) daily including Sundays and holidays comprising with the following equipments :- MH:- (a) DG set 1250 KVA - 01 No (b) DG set 625 KVA - 01 No (c) VCB11KV - 04 Nos. (one incoming and three Nos. outgoing) (d) Transformer 1000 KVA - 02 Nos. (e) Transformer 1250 KVA - 01 No. (f) ACB Electric Panel - 03 Nos. (g) APFC Panel - 03 Nos (h) Distribution Panel - 06 Nos. (j) All street lights.
Maintenance and outsourcing including minor repair / maintenance of Electric installation and attending day to day electric complaints (External and Internal Electrification) at CETC and SASF Birdhwal all OTM accommodation,and underground LT cable distribution at both locations by employing Electrician – 01 No. in one shift daily including Sundays and holidays comprising with the following equipments :- CETC:- (a) Transformer 315 KVA - 01 No (b) Transformer 250 KVA - 03 Nos (c) DG Set 25 KVA with acoustic enclosure with digital control Panel - 03 No. (d) LT distribution Panels - 04 Nos. (e) APFC Panel-04 Nos. (f) All street lights. SASF Birdhwal:- (a) Transformer 315 KVA - 01 No (b) Transformer 63 KVA - 01 No (c) DG Set 100 KVA with acoustic enclosure with digital control Panel - 01 No. (d) LT distribution Panels - 08 Nos. (e) APFC Panel-02 Nos (f) All street lights.
Maintenance and outsourcing including minor repair / maintenance of Electric installation at MAP Phase-I and underground LT cable distribution at location by employing Electrician – 01 No. in each shift for three shifts (each shift of 08 hours) daily including Sundays and holidays comprising with the following equipments :- MAP PHASE-I :- (a) Power transformer 33/11 KV, 3.15 MVA -02 Nos (b) C&R Panel 33 KV - 03 Nos. (c) VCB 11 KV - 08 Nos (d) RMU 11 KV - 01 No
Maintenance and outsourcing including minor repair / maintenance of Electric installation and attending day to day electric complaints (External and Internal Electrification) at MAP Phase-II, Sub Station 11KV and underground LT cable distribution at location by employing Electrician – 01 No. in each shift for three shifts (each shift of 08 hours) daily including Sundays and holidays comprising with the following equipments :- MAP PHASE-II :- (a) VCB11KV - 05 Board Panel - 03 Nos, 07 Board Panel - 01 No. (b) Transformer 250 KVA - 09 Nos (c) Transformer 160 KVA - 01 No. (c) Transformer 100 KVA - 01 No. (d) Main LT Panel - 11 Nos (e) Feeder Pilar Box - 27 Nos (f) APFC Panel - 11 Nos (g) All street lights.
Note for Srl No.1 to 4 :- (i) Minor repair includes all the periodical preventive maintenance such as tightening of nuts and bolts of Electric Panel, Transformers, VCBs, Earthings and tightening of loose connections and replacing thimbles, UG cables etc. The contractor shall obtain confirmation of periodical maintenance every 30 days and Testing of Earth Result of Transformer, Electric Panels, VCBs in presence of Engineer- in-charge and shall make a record of the same. (ii) The contractor shall make a register for recording of power factor daily in presence of JE and verified by Engineer-in-Charge. (iii) The contractor shall be maintained log sheet for each sub station. (iv) Daily cleaning inside and outside installations area complete all as directed by Engineer-in-charge & GE. (v) Cost of the repair and replacement of any demage items due to misoperation of the plant shall be paid by the contractor. (vi) Rates are deemed to be included in above quoted rates.No extra payment to be paid on this accounts. (vii) Bidders may please note that the rate quoted for outsourcing work shall not less than the minimum wages circulated by Chief Labour Commissioner, GOI, Min of Labour, New Delhi for Suratgarh (Class 'C' City) Plus ESI (EPF) & GST applicable to the bidder. Copy of applicable rate for ESI / EPF & GST shall be forwarded by the bidder alongwith bid documets cover 1. If the rate quoted by the bidder is lower than the applicable minimum wages + ESI / EPF + GST the same will be treated as 'Non-Bonafide' & the offer will not be considered for acceptance. (viii) Contractor shall collect “DHPP(N) Fuel” from MES store yard or from collection point as decided by Engineer-in-charge. Vehicle for the transportation of “DHPP (N) Fuel” from MES store yard or from collection point up to installations shall be provided by the Department free of cost to the contractor.
M&L for decarbonazing of bus bar chamber of 1000 Amps bus bar Make L&T and all affected parts, after diconnecting electric connections, taking out brunt accessories / control wiring, providing insulation of suitable size around bus bar with colour coding as per engineering pratice and replacement of brunt accessories (Male - female connector, tongle switch etc) and wiring, repairing of tripping mechanisam for making LT ACB panel serviceable in all respect complete all as specified and directed by Engineer-in-Charge. Note :- Any item required at site deemed included quoted rate no extra payment will be made on this account.
All as per item No 5 above but 2000 Amps capacity bus bar.
Supplying, installing, testing and commissioning of thermoplastic polycarbonate IP 65 outdoor type in accordance with EN 60 529 (dust proof, weather proof & water proof) power distribution board of suitable dimension as per engineer practice, shock proof, rust proof, corrosion free, acid & chemical resistant, fire retardant & self extingushing, UV Resistant, silica and halogen free recyclable material, glow wire tested at 960⁰C in accordance with IEC 60 695-2-11. type tasted as per IEC 61 439-1. total insulated with system. The manufacturer of board / panel shall submit a copy of ASTA certification by CPRI for the Degree of ingress protection in accordance with IEC 60529. The gasket material shall be polyurethane while the gasket shall be internally embedded including provision for taking incoming and outgoing cables duly marked with reveted letter plated of appropriate size for each feeder / block cable , danger board, detachable plate at bottom for cable entry etc. with bottom frame made out of angle iron 40mm x 40mm x 5mm and 600mm long 4 legs. The manufacturer of board / panel shall submit a copy of type test report of a board made out of polycarbonate thermoplastic panel in accordance with IEC 61 439-1. The report shall have mention of following tests performed and passed out satisfactorily:- (i) Tempreture rise. (ii) Dielectric properties (iii) Short circuit withstand current - rated peak & short time with stand current and rated conditional short circuit current. (iv) Efffectiveness of protective circuits (v) Clearance & Creepage distance (vi) Degree of protection (vii) Mechanical operation
Item No 7 Contd/-.......... The impact strength of polycarbonate enclosure / boards i.e. the degree of protection against mechanical load shall be in accordance with EN 50298-98 for IK 08. grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm and 100mm thick PCC (1:2:4) type B-1 as in floor over and including 100mm thick sub base of brick hardcore extended 100mm on all sides below panel body with and including following accessories :- Incoming (a) 250 Amps copper bus bar for phases and Neutral - 01 Set (b) MCCB 160 Amps, 25 KA, 4 Pole, thermal Magnetic release type - 01 No Make - ABB ordering code No 1SDA067410R1 / L&T cat part No CM090634OOMO / Schnieder Cat part No LV430320 Outgoing (a) MCCB 63 Amps, 25 KA, 4 Pole, thermal Magnetic release type - 02 Nos Make - ABB ordering code No 1SDA067404R1 / L&T cat part No CM97933OOH2 / Schnieder Cat part No LV429562 (b) MCB 40 Amps, Single Pole & neutral 240 Volts, 10 KA, ‘C’ Curve - 04 Nos Make :- ABB order code No 1SYS271112R0405 / L&T cat part No BA20400C / Schneider cat part No A9N2P40C (c) Digital Voltmeter flush type 0-500 Volts square type 96mm x 96mm - 01 No (d) Digital Ampere meter flush type 0-250 Amps square type 96mm x 96mm - 01 No (e) CTs 200/5 Amps - 01 Set (set of three) (f) Internal all links & control cable and indicators - set of three Note :- Cost of PCC, excavation and earth work is included in the unit rate of this item nothing extra shall be paid on this account.
All as per item No 7 above but comprising of following accessories Incoming (a) 400 Amps copper bus bar for phases and Neutral - 01 Set (b) MCCB 250 Amps, 36 KA, 4 Pole, thermal Magnetic release type - 01 No Make - ABB ordering code No 1SDA068070R1 / L&T cat part No CM98065OOPO / Schnieder Cat part No LV431640 Outgoing (a) MCCB 100 Amps, 25 KA, 4 Pole, thermal Magnetic release type - 02 No Make - ABB ordering code No 1SDA067406R1 / L&T cat part No CM97933OOK2 / Schnieder Cat part No LV429560 (b) MCCB 63 Amps, 16 KA, 4 Pole, thermal Magnetic release type - 03 No Make - ABB ordering code No 1SDA066816R1 / L&T cat part No CM90518OOKO / Schnieder Cat part No LV429562 (b) MCB 40 Amps, Single Pole & neutral 240 Volts, 10 KA, ‘C’ Curve - 04 Nos Make :- ABB order code No 1SYS271112R0405 / L&T cat part No BA20400C / Schneider cat part No A9N2P40C (c) Digital Voltmeter flush type 0-500 Volts square type 96mm x 96mm - 01 No (d) Digital Ampere meter flush type 0-250 Amps square type 96mm x 96mm - 01 No (e) CTs 200/5 Amps - 01 Set (set of three) (f) Internal all links & control cable and indicators - set of three Note :- Cost of PCC, excavation and earth work is included in the unit rate of this item nothing extra shall be paid on this account. ---------------------------------------------------------------------------------------------------------------------------------------- Note :- A sum of Rs. 7000/- will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 21 (Schedule of Credit) of Tender documents.
M/s Rohit Construction Co.
godara construction company
GM Construction Co.
DIAMOND ELECTRICALS
GURDEEP SINGH AND COMPANY
Gupta Suppliers
AJAY ELECTRIC COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .