Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.0 LAccepted-AOC FLAT NO 101 UGF FRONT LHS RZ B 49A KAILASHPURI PALAM COLONY NEW DELHI 110045 | SOUTH WEST | DELHI | 110045 | L1 | Accepted-AOC L1 | |
| 2 | L2₹15.7 L+₹1.4 L (10.1%)Rejected-Finance 216 UGF RAM VIHAR ANAND VIHAR DELHI 110092 | SHAHDARA | DELHI | 110092 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹16.5 L+₹2.3 L (15.9%)Rejected-Finance G 86 DATA RAM SECTOR 18 ROHINI NEW DELHI DELHI 110085 | NORTH WEST DELHI | DELHI | 110085 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹17.0 L+₹2.7 L (19.2%)Rejected-Finance WZ 576 577 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹34.9 L+₹20.6 L (144.6%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹19.3 L
EMD Value
₹38,528
Closing Date
9 Aug 2021, 6:00 pmClosed
GE (N) DELHI CANTT-10
GE (N) DELHI CANTT-10
REPAIR MAINT OF DG SETS OF VARIOUS CAPACITIES SERVICING AND MAINT OF EOT CRANE AND REPAIR MAINT OF SEWAGE PUMPS WITH CONNECTED WORKS MISC ITEM AT ANAND PARBAT AND REPAIR AND MAINT OF RO SYSTEMS WITH CONNECTED AT AMAR VIHAR DGQA AREA ANAND PARBAT M
2021_MES_459139_1
GE/NORTH-33/2021-22
Open Tender
Civil Works
Item Rate
333 days
GE (N) DELHI CANTT-10
As per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (N) DELHI CANTT-10
₹38,528
Yes
21 Sept 2021
12 Jul 2021
11 Aug 2021
12 Jul 2021
9 Aug 2021
26 Jul 2021
Amount
Comprehensive Maintenance of DG Sets & AMF Panel of Make as mentioned against each DG Sets below including preventive maintenance checks of engine and alternator for trouble free function as per recommendation and attending break down/complaint as and when on required basis, monthly maintenance on regular basis complete with Preventive Maintenance ('B' check) twice a year including replacement of engine oil/coolant, replacement of required necessary spares and replacement of all types of filters, belts along with rectification of minor defects and cleaning of air filters/breather, coolant tank with blower and labour for filling/topping up and tuning of engine for DG set as listed below complete all as specified and directed.
40 KVA DG Set -01 Nos (Location:- Ranjith Hall, Make: Crompton Greaves)
62.5 KVA DG Set -01 Nos (Location:- Bapa Nagar Pump House, Make: Kirloskar)
62.5 KVA DG Set -01 Nos (Location:- Map Ph-II Pump House, Make: Greaves Power)
100 KVA DG Set -01 Nos (Location:- MAP Ph-I Pump House, Make: Jackson/Kirloskar)
125 KVA DG Set -01 Nos (Location:- Amar Vihar, Make: Greaves/Kirloskar)
160 KVA DG Set -01 Nos (Location:-KLP area, Make: Cumins/Stamford)
200 KVA DG Set -03 Nos( Location:- Deepak Vihar, Make: Greaves Power) Contd/(Notes)______
NOTES:- (a) After monthly maintenance, the work to be certified by JE (E/M)/Engr-In-Charge on Job Card. (b) Cost of materials and labour as mentioned in below are not included with Comprehensive Maintanance. (c) The Comprehensive maintenance of work shall be done through respective OEMs or their authorised dealers. (d) The contractor shall carry out routine checking of the complete DG Sets and rectify the minor/major defects noticed immediately. If complaints were not attended within one hours a penalty of Rs 500 per fault per hour shall be imposed over contractor and shall be deduct from his dues. (e) Contractor has to carry out monthly maintenance with examination of suction and exhaust valves for smooth operation of DG Sets. (f) Contractor shall be responsible to monitor the followings of all DG Sets during Comprehensive Maintenance and the cost of same is deemed to be included in the quoted rate:- (i) Examination and cleaning of fuel injection, nozzles. (ii) Check clearance of suction and exhaust valves and adjust if required, (iii) Changing of oil filters, fuel filters screen filters assy. (iv) Maintenance of coolant level all as directed by the Engineer-in-charge. (v) Change of Hydraulic governor oil (vi) Change of oils (vii) Clean alternator winding in position by forced air and internal surfaces lubricate DE & NDE bearings (viii) Tightining of all nut bolts. (ix) Greasing of all points. (x) Test IR value of alternator winding and recording the readings (xi) Checking of any leaking in fuel & oil lines and rectification of the same. (xiii) Any other check as reqd for efficient running of equipment all as specified & directed by Engr-in-Charge. (xiv) The rates quoted against the above mentioned items is deemed to be included for cost of labour, cost of T & P required for replacement of unserviceable parts and cost of handling / transportation of defective item to & from civil workshop for repair if required. Spares shall be measured and paid separately under respective items.Supply only items labour cost is deemed to be included in this item. (xv) In case of break down, the additional manpower if required will be arranged by the contractor. The cost of the same are deemed to be included in the quoted rate.
Supply only in replacement of V belts for radiator fan / main shaft/ cam shaft for the DG set of capacity 40 KVA to 200KVA as per existing size and model complete all as specified and direceted.
Supply only in replacement of fuel filters for the DG set of capacity 40 KVA to 200KVA as per existing size and model complete all as specified and direceted.
Supply only in replacement of Oil lub filters for the DG set of capacity 40 KVA -200KVA as per existing size and model complete all as specified and direceted.
Supply only in replacement of Air filters for the DG set of capacity 40 KVA -200KVA as per existing size and model complete all as specified and direceted.
Supply only in replacement of Lub oil (15W40) for the DG set of capacity 40 KVA -200KVA as per existing size and model complete all as specified and direceted.
Supply only in replacement of coolant for the DG set of capacity 40 KVA -200KVA as per existing size and model complete all as specified and direceted.
S&F in repairs for rewininding with super enamelled copper wire of existing size & insulating the field coil assy, replacing bentec assy of the self starter assembly 12/24 Volts and refixing the same after repairs and testing complete all as specified.
S&F in replacement of self starter assembly 12/24 Volts existing size and model and testing complete all as specified.
S&F in repairs for lead acid batteries of 12 Volts, 110-150 AH, 22-28 plates,maintenance free type including accesories like terminal clamps, copper cable of required size and length, petroleum jelly and baterry initial charging all as specified and as directed. Make Exide/Amar Raja/Luminious/HBL
Supply and fixing in repair for battery charger capacity 6/12 Amp, 12/24 Volts for DG set complete all as specified and directed.
M&L for carring out repairs to 12/24Volt dynamo by replacement of carbon brush, electronic regulator , rectifier,windings, bearings reassembling the same and testing complete all as specified and directed.
Supply and fixing in replacement aganist repairs of stop solenoid/ shut off valve of capacity 40 to 200 KVA DG Sets of existing make along with screen Filter including wiring connecting to panel circuit, starting and testing on load complete all as specified and directed.
Supply & fixing in repairs of thermostat element alongwith complete assy for DG set connection and testing complete all as specified and directed.
M& L for Repairs and calibration of PT fuel pump as per the calibration procedure and norms as per manufacture's guide lines for DG Set of various capacity from 40 to 200KVA including replacement of worn out and unserviceable "O'rings / shutt off valve/Plungers complete all as specified and directed.
Supply and fixing in replacement of Control assembly for DG Set capacity 40 to 200 KVA with necessary modification to controll wiring, replacement of controll relays , programming with all the parameters for safety protection and running suitable for the existing DG sets. .
Supply and fixing in replacement of necessary control wiring for making the AUTO/MANUAL Mode condition of the existing DG Sets 40 to 200 KVA complete all as specified and directed.
Supply and fixing in replacement of Automatic Voltage Regulator (AVR) suitable for DG Set of 40 KVA to 200 KVA capacity including taking out old unserviceable AVR and making all connection, testing for smooth operation complete all as specified and directed.
Supply and fixing in replacement of Magnetic pickup Sensor suitable for 40-200 KVA of exist make DG set connecting with panel circuit, starting and testing on load complete all as specified and directed.
Supply and fixing in replacement of Oil Pressure Sensor suitable for 40-200 KVA of make exist DG set connecting with panel circuit, starting and testing on load complete all as specified and directed.
Supply and fixing in replacement of Coolant Tempetarure Sensor suitable for 40-200 KVA of make exist DG set connecting with panel circuit, starting and testing on load complete all as specified and directed.
Dismantaling the unserviceable radiator from DG set of capacity 40 to 200 KVA of exist make and transporting to contractors workshop for locating the fault and overhauling & cleaning using air compressor, de-scaling with acid, removal of leakage including soldering and welding, brazing as required and renewal of gaskets, nuts, bolts, mounting pads, hoses, clamps, clips, etc. and refixing/ reassembling its original position after making proper connections, aligning, testing including transporting back the same to site complete all as specified and directed. (Note :- The rates quoted by the contractor shall deemed to include the replaced spares / parts, transportation cost from site of installation to contractor's repair workshop and back.)
Cleaning of diesel tank of various capacity DG set inside/ out side of tank complete with drain out DHPP(N) and cleaning tank and applying two coats of synthetic enamel paint (1st grade quality) on out side of tank incl necessary weldings and refilling the DHPP(N) & testing complete all as specified and directed.
Supply and fixing in repairs of Electronic timers with auxilary voltage of 110/240/415v 50Hz for operation of 12-120 secs complete all as specified and directed.
Supply and fixing in repairs of speed control units 40 to 200 KVA DG stes of exist make complete all as specified and directed.
Supply and fixing in repairs Auxilary control Contactors side mounting Add On's (1NO+1NC) as per existing capacity at respective site complete all as specified and directed.
Supply & fixing in replacement of new Power contactor of capacity 360 Amp 4 pole,415 volts with side mounting, MCX type auxilary contacts operable at 220 V, 50Hz including takingdown of defective Power contactor from AMF panel complete all as specified and directed.
Supply and Fixing in replacement of 3 phase digital multi function meter with suitable accessories and fixing arrangements complete all as specified and directed.
Supply and Fixing in replacament of LED type phase indicator to be fitted on panel (R,Y ,B as per site requirement) as per existing model/ capacity including taking down of old unserviceable one complete all as specified and directed.
Supply and fixing in replacement for alaram sysytem with complete wiring complete all as specified and directed.
Supply and fixing in replacment of DG set door lock and key assembly suitable for exit DG set doors as per existing model complete all as specified and directed.
Removal of rusted MS sheet at any portion of canopy and supply and fixing of 3.15 mm thick MS Sheet of size 300 mm x 300 mm with fitting / welding as specified and directed.
M&L for painting two coats of synthetic enamel paint of existing colour at site over a coat of red oxide primer for DG sets complete body surfaces complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick, burried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead by means of bolts, nuts, check nuts and washer of galvanised iron strip 32 x 6mm as earth lead as shown in electrical plate No. 3 of SSR Part I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal od surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm bore GI tubing medium grade for watering pipe, 40mm bore medium grade GI pipe for protection of GI earth strip and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) tyep A1 duly reinforced with 8mm dia TMT bar @ 100 mm c/c both ways, one lifting handle made out of 10mm dia TMT bar 250mm long embedded in cover slab and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layer of 15 cm thick including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge.
Repair of earth pit incl required exacavation, earth work and PCC work to make good damaged/disturbed surfaces of earth pit chamber & making new pit cover of RCC 1:2:4 type B-1 using 20mm graded stone aggregate reinforced and lifting handle on RCC cover with 8 mm MS bars at 150 mm centre to centre both ways incl supply & fixing of wire mesh and funnel including re-connection of earth wire/strip with panel/transformer using GI nut, bolts & washer complete all as specified & directed
M&L for repair/maint/overhauling long travel mechanism with lubrication LT wheel & gear box, Over hauling hoist mechanism with reduction gear box, over hauling cross travel mechanism with gear box, Testing & commissioning 5 Ton EOT Crane, Replacement of defective any minor parts complete all as specified and directed.
M&L for painting of complete EOT crane with Golden yellow colour paint including writing letters or figures (Block, Roman, Italic or Indian) n exc. 30 cm high with synthetic enamel paint as per colour scheme all as specified
M&L for replacement of PVC flexible cable 1.5 sqmm 16 core copper wire complete
M&L for replacement of Rotary Geard limit switch Ratio 48:1
M&L for replacement of lever type limit switch
M&L for replacement of E.M Brake(200mm) Coil 415V,AC
M&L for replacement of lubrication Gear Oil No.68
M&L for replacement of current collector shrouded Busbar type
M&L for replacement of 3 pole power contactor type ML4 type complete.
M&L for replacement of Hydraulic Thrustor Brake 300mm 34Kg complete
M&L in replacement of damage CT shaft made out of EN8 material medium carbon steeloff size in 80mmx500mm with various step and key way slot 12mm both side on shaft complete.
M&L in replacement of spherical roller bearing off suitable size complete.
Repair/maintenacne and servicing of RO system, 500/700/1000 LPH capacity. Make of Eukawa,Aquefresh&SIMA respectively, including servicing/cleaning of all filters/back wash etc all as directed. Note :- (a) Unserviceable and consumable parts will be measured and paid seperately unde relevent items as mention in below. (b)Servicing shall be done monthly for RO system and also to be attended as on tele call from users. (c) The contractor shall carry out routine checking of the complete RO system and rectify the minor/major defects noticed immediately. If complaints were not attended within one hours a penalty of Rs 500 per fault per hour shall be imposed over contractor and shall be deduct from his dues.
Replacement in repairs membrane high pressure, 500 LPH.Make DOW/Hydronautics/ CSM
Replacement in repairs membrane high pressure, 700 LPH.Make DOW/Hydronautics/ CSM
Replacement in repairs membrane high pressure, 1000 LPH.Make DOW/Hydronautics/ CSM
Replacement in repairs for sediment(sand and silt), dirt and rust particles, high efficiency, low pressure drop, removal up to 5 micron filter cartridges suitable 500/700/1000LPH capacity makes as per existing all as specified and directed.
Replacement media in sand filter (gravel,pebles,fine sand).
Replacement activated carban in barban filter.
Supply only RO antiscalent high PH for membrane cleaner.
Replacement in repairs Rotameter suitable for 500/700/1000LPH capacity RO system. Make as per sample.
Replacement in repairs of UPVC pipe 20mm dia with fitting complete suitable for RO system as per sample.
Replacement in repairs of Membrane housing suitable for 500 LPH capacity RO system of Aquefresh Make .Painter/Hitech.
Replacement in repairs of Membrane housing suitable for 700 LPH capacity RO system of Aquefresh Make .Painter/Hitech.
Replacement in repairs of Membrane housing suitable for 1000 LPH capacity RO system of Aquefresh Make .Painter/Hitech.
Replacement in repairs of housing bowl suitable for 500/700/1000 LPH capacity RO system of Aquefresh Make .As per sample.
Replacement in repairs of LT Relay,230V AC supply suitable for 500/700/1000 LPH capacity RO system Make .As per sample.
Supply and fixing in reapirs of multi port valves fixing at sand filter and carbon filter vessles all as specified and directed. Makes as per sample.
S&F,testing and commissioning high pressure pumps for RO plant, vertical type having speed 2780 RPM, 230 V, 2HP, class F insulation, eff 76% complete with fixing necessary accessories incl taking down old unsv deposit to store yard complete all as specified and as directed. Make : CRI/Crompton/Kirloskar.
S&F,testing and commissioning self priming regenrative pumps for RO plant, Mini star model having speed 2780 RPM, 230 V, 1HP, class B insulation,size 25x25mm, head 6-45 mtrs,dis range 50 LPM with fixing necessary accessories incl taking down old unsv deposit to store yard complete all as specified and as directed. Make : CRI/Cropmton/Kirloskar.
S&F in repairs for Rotational moulded polye- thylene water storage tanks 100 Ltrs capacity (cylindrical vertical with closed top in white colour transparent type for using antiscaling chemicals for RO plants) hoisted and fixed in position all as specified and directed.
M&L for Disconnection electrical and water connection of the raw water feed monoblock pumpset with motor and base plate and transporting to work shop opening carefully and rewinding the burnt out winding, replacement of bushes, gland packing, ball bearing, rubber gasket nut and bolt and replacing the required spares parts as per existing complete re-fixing its in original position and making out all electrical and water connection and testing complete all as specified and directed for the size/ capacity of motors upto 2 HP. Note :- Rate includes transportation of motor from the place of installation for repairing and reinstalling the same on existing foundation & testing & commisioning.
M&L for Disconnection electrical and water connection of the high presuure feed pump, multi stage centrifugal type and transporting to work shop opening carefully and rewinding the burnt out winding, replacement of bushes, gland packing, ball bearing, rubber gasket nut and bolt and replacing the required spares parts as per existing complete re-fixing its in original position and making out all electrical and water connection and testing complete all as specified and directed for the size/ capacity of motors upto 2 HP. Note :- Rate includes transportation of motor from the place of installation for repairing and reinstalling the same on existing foundation & testing & commisioning.
S&F in repairs for antiscalant dosing unit capacity upto 6 LPH @ 3.5 bar incl inlet and outlet flexible pvc pipes all as specified and directed.
S&F in repairs pressure gauges for monitering of flow meters all as specified and directed.(Makes as per sample)
Testing of treated water of STP and submission of detailed test report to the office of the Engr-in-charge and testing in Govt approved laboratory as approved. (a) Carrying out minimum essential testing of water as per IS 3025 mandatory for chemical, odour, PH Value TSS BOD COD residual chlorine total nitrogen, sulphate, oil and grease ammonical Nitrogen (NH3-N) and Bacteriological total collifrom organisms as below:- Rest of the characterstied of the treated water shall be as per IS : 3025 Note 1 - rate quoted shall deemed to be included for :- (i) Cost of sterilised bottle as required (ii) To and fro transportation charges for collection of sample
(i) TSS: < 10 Mg/ ltrs
(ii) BOD : < 10 Mg/ ltrs
(iii) COD :< 150 mg / Ltrs
(v) Total coliform : ,< 100 MPN/100 Ml (desired Nil)
(vi) Residual CI > 1 mg/ Ltr
Rest of the characterstied of the treated water shall be as per IS : 3025
Note 2 - Rates quoted shall deemed to be included for :-
Cost of sterilised bottle as required
To and from transportation charges for collection of sample
Note 3 - Incase contractor fails to provide monthly test report a penalty of Rs 3000/- per test report shall be recovered from the contractor dues.
Testing of Sewage sludge water as per revlevant IS of STP and submission of detailed test report to the office of the Engr-in-charge and testing in Govt approved laboratory as approved by GE (a) Carrying out minimum essential testing of sewage water as per revlevant IS mandatory for chemical, odour, PH Value TSS BOD COD total nitrogen, sulphate, oil and grease ammonical Nitrogen (NH3-N) and Bacteriological total collifrom organisms and other charaterstics as per relevant IS of sewage water:- Note 1 - Rates quoted shall deemed to be included for :- (i) Cost of sterilised bottle as required (ii) To and fro transportation charges for collection of sample
Supply & mixing of Sodium Hypo Choloride having 10 % content
Supply & mixing of Poly Aluminium Choloride 100 % purity
Supply & mixing of Poly Electrolite 100 % purity
Supply & filling compressor oil 460 Make : Castrol
Material and labour in replacement of quartz silica sand 32-64 grade
Material and labour in replacement of quartz silica sand 16-32 grade
Material and labour in replacement of quartz silica sand 8-16 grade
Material and labour in replacement of quartz silica sand 4-8 grade
Material and labour in replacement of activated carbon IV 1000
Material and labour in replacement of FEB (MBBR) Media suitable for STP make as per sample.
Taking out complete pebbles from the bottom upto the depth of 0.6 Mtr of the filter of size 1800 mm dia and 2300 mm height and refilling the same pebbles after washing and cleaning thoroughly.
Periodical Cleaning of Sewage well as capacity (upto 5mtrs dia and 9 mtrs depth) cum and Removing of settle down Sewage sludge cum mud/De-Silting etc. all as required at site and directed at Anand Parbat Mil Stn (KLP location, MAP Ph-I) and COD area. Note: The rate quoated by the tenderer is deemed to be included in the unit rate of the following :-
Diesel Driven Pump Set of appropriate capacity not less than 5/7.5 HP with operator including necessary POL required at site for De- Watering of Sewage septic water including PVC heavy duty flexible hose pipe for suction and delivery purposes
Tractor mounted storage tank of appropriate capacity not less than 1 KL with driver directly collected from the soak well and disposing the same to the location out side of Military contonement where as approved by PCB and also liase with Delhi Muncipal corporation board as directed.
Tractor/truck with driver for disposal of sewage sludge and POL required for the same (duly covered with necessary tarpaline ) and depositing the same to the location where approved by PCB or as directed.
Labour element and T&P required for removal of settled down sewage sludge/mud inside the sewage tank for scooping out from inside and below the septic/staining sewage water inside the well and lifting the same and deposited out side of Military contonment and out side location as mentioned above.
Appropriate qty of Phenyle required at site for Sterilization of sewage sludge being collected in the Sewage tank and all as directed.
Necessary Oxygen Mask, Gloves, Gum Boot and all other safety aspects and including necessary Phawda, Steel Bucket, Manila rope etc. required at site and all as directed.
M & L for cleaning of treated water tank at Anand Parbat at KLP loaction STP of storage capacity of water 50000 gallons, filter feed tank of capacity 63 cum and chlorine contact tank of capacity 17 cum thoroughly by removing mud, grits etc from the tank by following method :-
Cleaning inner surface of tank complete by scraping with steel wire brush and and removing mud and sludge collected inside the tank manually at a distance not exceeding 50 mtr all as directed.
Washing with clean water and bleaching powder mixture throughly complete tank internally and removel of left out sludge if any at site at a distance not exceeding 50mtr all as directed.
Supply and laying including taking up galvanised steel water tubing medium grade ISI marked screwed socketed joints complete with all tube fitting (such as bends,elbow, tees,short pieces,connectors,back nuts,diminishing pieces,caps,plugs, threaded flanges and unions,etc) and fixing complete with clips,wall hooks,wooden plugs,or laying in trenches,etc.,also cutting,screwing and waste and for making forged bends on piping as required at site including taking down the existing pipe line with fitting etc of following sizes:-
80 mm dia
50 mm dia
40 mm dia
Supply and laying Mild steel water tubing heavy duty with wlded joints complete with all tube fitting (such as bends,elbow,tees,short pieces,connectors,back nuts,diminishing pieces,caps,plugs, flanges and unions,etc) and fixing complete with clips,wall hooks,wooden plugs,or laying in trenches,etc.,also cutting,screwing,welding and waste end for making forged bends on piping as required at site including taking down the existing pipe line with fitting etc of following sizes:-
40 mm dia
50 mm dia
80 mm dia
100 mm dia
Supply and fixing Butterfly valves iron body screwed down high pressure with iron wheel head/ long shank and cup butterfly type screwed both ends for iron pipe including taking out unserviceable valve for the following sizes:-
40 mm dia
50 mm dia
80 mm dia
M&L for spray painting two coats of synthetic enameled paint of specified colour after preparation of surface and writing letters and numbers complete of complete Sewage treatment plant capacity 100 Cum/day with equalization tank, Raw sewage pumps, MBBR reactor, Chlorine tank, filter feed pump, Dual media filters, RCC treated water tank, treated filter pumps, sludge drying beds, oil free blowers and accessories complete all as specified and directed.
M&L for Disconnection electrical and water connection of the monoblock pumpset with motor and base plate and transporting to work shop opening carefully and replacement of winding, bushes, gland packing, ball bearing, rubber gasket nut and bolt and replacing the required spares parts as per existing complete re-fixing its in original position and making out all electrical and water connection and testing complete all as specified and directed for the size/ capacity of motors upto 7.5 HP. Note :- Rate includes transportation of motor from the place of installation for repairing and reinstalling the same on existing foundation & testing & commisioning.
M&L for Disconnection electrical and water connection of the compressors and transporting to work shop opening carefully and replacement of spare parts bushes, gland packing, ball bearing, rubber gasket nut and bolt and replacing the required spares parts as per existing complete re-fixing its in original position and making out all electrical and water connection and testing complete all as specified and directed for the size/ capacity of up to 110 M3/hr. Note :- Rate includes transportation of compressor from the place of installation for repairing and reinstalling the same on existing foundation & testing & commisioning.
M&L for Lifting/lowering of non clogging submersible pump and motor capacity up to 7.5 HP from Sewage well after disconnecting electric and water connection of any make and any size capacity under any of chain pulley block or manually appropriate length upto 10Mtr after opening the socket and pipe eplacement of winding, bushes, gland packing, ball bearing, thrust bearings, sand guard plate,GM impellers,rubber gasket nut and bolt and replacing the required spares parts as per existing complete re-fixing its in original position and making out all electrical and water connection and testing complete all as specified and directed.
Supply and fixing in reapirs of multi port valves fixing at media filter vesselses for STP all as specified and directed. Makes as per sample.
S&F in repairs for dosing unit capacity electronic metering pumps for chemiclas dosing system for STP incl inlet and outlet flexible pvc pipes all as specified and directed.Makes as per sample
Material & Labour for cross arms, bracings, supports, clamps, angle iron, flats, ladders and back plates fabricated from MS structural steel sections including nuts, bolts and washers of suitable sizes including welding, bending (cold or hot), drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coats of aluminum paint over one coat of red oxide primer, complete all as directed.
S&F in repairs for Rotational moulded polye- thylene water storage tanks 250 Ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed.
Repair/maintenance and servicing of RO system, RO+UV+UF 12.5 LPH capacity and storge capcity 12 Ltrs of purified water. Make EUKAWA, including servicing/cleaning of filters. (un-serviceable parts will be meausred and paid seperately) Under following respective items Make of EUKAWA
Note :- (a) Unserviceable and consumable parts shall be measured and paid seperately under relevent replacement items only (b) Servicing shall be done quarterly for each RO system and also to be attended as on tele call from users. In case any complaint contractor or his rep shall not come to the site after receiving tele call from users for attending repair within twelve hours, a penalty of Rs 600 per complaint per day shall be imposed over contractor and shall be deduct from his dues. (c) Servicing shall be done through authorsied dealer of OEM. (d) Spare parts shall be purchased through authorsed dealer of OEM. (e) Rate quoted are deemed to be inclusive of labour required for replacement of any defective parts in between consecutive services.
Replacement in repairs membrane filmtech 75 GPD.
Replacement of Memberane housing of RO system with suitable size.
Replacement in repairs raw water pump kemflow K-48
Replacement in repairs AC/DC Adopter complete.
Replacement in repairs solenoid valve.
Replacement in repairs candle/inline filter for prefilter.
Replacement in repairs candle/inline filter for sediment filter.
Replacement in repairs candle/inline filter for carban filter.
Replacement in repairs UV lamp.
Replacement in repair prefilter bowl with spun candle filter 10" size.
Replacement of flow resistance of RO system complete.
Replacement of outer cover/body of RO system with suitable size.
Replacement of UV electronic Ballast (Choke) 11W of RO Make: Philips/Desent.
Replacement of float valve as per existing suitable for RO system complete.
Replacement of Bib Tap as per existing suitable for RO system complete.
Replacement of PVC Elbow suitable for RO system complete.
Sch of Credit- Total contract sum shall be calculated after deduction of Sch of Credit amount Credit amount - 27705.00
V M CONSTRUCTION
NEETU TRADERS (INDIA)
Shiv Enterprises
Surjit and Sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .